Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAdmitted-Finance | ₹2.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.8 Cr+₹24.6 L (9.70%)Admitted-Finance | ₹2.8 Cr+₹24.6 L (9.70%) | L2 | Admitted-Finance |
| 3 | L3₹3.1 Cr+₹59.5 L (23.5%)Admitted-Finance | ₹3.1 Cr+₹59.5 L (23.5%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | MOHMAMMAD ABDULLAH PUJOO L1 | Dar and Sons L3 | M/s Mohammad Shafi Mir L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of 40 kVA – 3 Phase D.G. The DG Set shall be comprising of diesel engine and alternator coupled together and fitted with standard accessories, control panel, battery, ant vibration pads, MS canopy duly painted and conforming to noise pollution specifications/ requirements of environmental protection rules 1986 as laid down by Ministry of Environmental (Protection) and Forest – read with GSR-371(e) Dated:17-02-2002 and GSR 520(E) Dated: 01-07-2003 in respect of emission norms for the engine and in respect of the noise level for the DG Set read with up to date amendments. The engine shall conform to IS/10000/BS649/BSS5514. The DG Set should be rated for continuous duty with overload provision of 10% for the period not exceeding one hour in twelve hours. DETAILS AS PER ESTIMATE | 1 | JOB | 5,20,000 ₹5,20,000 | 4,60,000 ₹4,60,000 | 3,65,000 ₹3,65,000 Lowest |
| 2.00 | Submersible Pumping Unit:
Providing, fitting, installation, testing and commissioning of submersible pumping unit of following specifications:
Pump:
Discharge of the Pump = 7000 GPH
Dynamic Head = 145 M
Speed = 2900 RPM
Mat. Of the impeller = Steel Alloy
Efficiency = Not less than 60 %
Shaft Material = Stainless Steel
Fluid to be handled = Water with solutes
Motor:
Rating = Corresponding to the head and discharge not less than 30 HP.
Frequency = 50Hz
Working Voltage = 415 ± 15%
Efficiency = Not less than 60%
Make = KSB/ Kirloskar/Pluga
The job also includes providing and fitting of suitable dia nipple of mild steel having length 2.5’ duly threaded up to suitable length at one end and flanged at the other end. The job includes providing and fitting of mild steel crate around the pump and motor. Along with 2.5” MS clamps 01 Nos. fabricated out of MS sheet of 20mm thick and reducer 4x3” MS. Original Manufacturer’s Test certificates in original to be provided with the material before installation. Following Test Certificates of Original Manufacturer shall be furnished with the pumping equipment.
- Performance test certificate
- Laboratory test
- Overload test
- Insulation resistance test
- High voltage test
- Leakage current test | 3 | JOB | 1,35,000 ₹4,05,000 | 1,70,000 ₹5,10,000 | 95,000 ₹2,85,000 Lowest |
| 3.00 | Column Pipes:
Providing, fabrication, installation and testing of 65mm dia MS column pipe (15 Nos. 10 feet each in length), flanged (14mm Thick flange with grove cutting for 16sq mm submersible cable) and provided with necessary brackets and gaskets etc as per sample. | 1 | JOB | 75,000 ₹75,000 Lowest | 96,000 ₹96,000 | 85,000 ₹85,000 |
| 4.00 | Control Valves and delivery manifold:
Providing, installation, testing and commissioning of DI control valve viz,
1. 65mm dia Sluice valve (PN 1.6) --- 02 No.
2. 65mm dia NRV (PN 1.6)----04 No.
Make: VAG/ TALIS/Sigma flow
The job includes cutting of pipe at site and fitting of the above valves as per requirement includes all required fittings viz. 14mm thick flanges, Bends gaskets, nut bolts etc. | 1 | JOB | 1,10,000 ₹1,10,000 | 94,000 ₹94,000 | 55,000 ₹55,000 Lowest |
| 5.00 | Voltage Stabilizer:
Providing, installation,testing and commissioning of 75 KVA Voltage Stabilizer with of following specifications:
i. Range: 180 V – 415 V
ii. Copper wound with adequate insulation and thickness suitable to the duty to be performed.
iii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength.
iv. Hysteresis loses to be minimum and temperature not to exceed 700C.
v. Air gap to be minimum to avoid Eddy formations for it the coils to
be immersed in insulating varnish and dried by suitable means.
vi. Voltage regulator switch to be of plate type with copper contact points having six boosting steps. The contacts to be suitable to withstand over loading current at least double the rated current over the considerable period of time.
vii. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside.
viii. The container at its top to be fitted with porcelain insulators for housing poles.
ix. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The creapage distance between the poles to be sufficient enough to accommodate the required size tube terminals to prevent arcing.
x. The top of the container to have a display panel for housing 02 numbers voltmeters
0- 500V, square dial flush type along with 4 way selector switch and set of neon indicators.
xi. Insulating media (T. Oil) of 11 KVA grade to be provided and filled with dielectric strength of 5 KV at 4m air gap.
xii. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer.
Rating of stabilizer: 75 KVA
The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables.
(The Voltage stabilizer to be manufactured in a registered workshop in presence of person authorized by the undersigned). The T-Oil of specific grade should be provided in a separate barrel. | 2 | no | 1,90,000 ₹3,80,000 | 1,90,000 ₹3,80,000 | 1,25,000 ₹2,50,000 Lowest |
| 6.00 | Servo Stabilizer:
Cooling Oil Cooled (Servo Stabilizer)
Capacity 100 KVA
Input Voltage 160-480 Volts (Phase to Phase)
90-270 Volts (Phase to Neutral)
Output Voltage 400 Volts ± 1% (Phase to Phase)
230 Volts ± 1% (Phase to Neutral)
Type Suitable for:
100% Balance Load
100% unbalanced Supply
Application Indoor Type
Standard IS 2026 & IS 9815
Phase 3-Ph, 4 Wires
Ingress Protection IP 55
Frequency 50 Hz
Wave Form Distortion Nil (Negligible)
Response Time Instantaneous (mili sec.)
Speed of Correction 20 to 60 V/sec (as required)
Mode Of Operation Automatic/Manual
Suitability Suitable for all Power Factors.
Duty Cycle Continuous 24 Hrs.
Efficiency More than 98%
Losses at No Load 0.4% of the total capacity
Losses at Full load 1.9% at full load.
Temp. Rise 45°C Deg.Cent. Above Ambient.
Laminations Used Imported Low Losses CRGO Laminations - M4 Grade.
Copper Used “Sterlite” Make- 99.9% Pure Electrolytic Grade.
Carbon Brushes Used Imported High Grade Graphite
Class of Insulation Class - A, Greater than 6M ohms
Break Down Strength 2500v AC for 1 minutes (for Transformer)
Construction
The unit will comprise of 3 Nos. Individual Single Phase Unitsof 1/3rd of the total capacity connected in star configuration. Further, each of the three phases will further comprise of following:
In Each Phase In Complete Servo
1 No. Digital Micro Controlled Processor Based Control Card with elegant push buttons for operations. 3 No’s
1 No. AC Synchronous Servo Motor 3 No’s
1 No. Copper Wound motorized variable auto transformer, wound on toroidal CRGO laminations with High quality graphite carbons for smooth functioning. 3 No’s
1 No. Buck n Boost series transformer. 3 No’s
General Arrangements:
All the above will be incorporated inside high quality epoxy painted sheet steel tank fitted with cooling radiators and mounted on unit-directional wheels, other fittings would include as follows
Lifting Lugs Earthing Terminals – 2 No’s Oil filling valve
Oil Level Indicators Rating Plate Name Plate
Terminal Arrangement:
Cable box suitable for Input & Output armoured cables of appropriate rating.
Suitable Aluminium bus bars/terminals will be provided. with stem type terminals
For auxiliary connections.
Protections
The Servo Voltage stabilizer must be fitted with the following protection devices.
Over voltage Protection trip.
Under voltage trip.
Time delayed operation
Overload trip
Short Circuit protection.
Single Phase Protection.
Phase reversal Protection.
The job includes providing/ installation/ testing and commissioning of 200 A Change over switch for connecting the Stabilizers. The specifications of the Change over switch are as follows:
The job includes Providing, Installation, testing and commissioning of 3 phase, 200A, manually operated changeover switch. The job shall include proper thimbling of the terminals of the conductor as input to the equipment and the outgoing copper terminals from the switch of desired specifications at site. The other broad band specifications of the changeover switch are given as under:
a. Type: Manual Changeover in Sheet Steel Enclosure
b. No. of poles: 4
c. Rated Voltage: 415V
d. Rated Current: 200
Original Manufacturer’s Test certificates in original to be provided with the material before installation. | 1 | JOB | 3,90,000 ₹3,90,000 | 7,30,000 ₹7,30,000 | 1,65,000 ₹1,65,000 Lowest |
| 7.00 | Sub Station: The construction of Sub Station includes:
i. Providing and erecting of four numbers of steel tubular poles 9m (SP33, ISI mark HTL-IS 1161 or IS-2713) with base plate 350mmx350mmx5mm long as per the latest IEE rules for fabricating 04 pole structure (with 2 NO. 9m SP33 poles and 02 No. 150mm dia 8mm thick pipes cut to adjust the height of the station bed as per site engineers instructions.
ii. Fabrication, providing and fitting of ISMC-100 (as per the drawing attached).
iii. Providing, fabrication and fitting of ISMC-150 pieces 8 feet long each 12 Nos. complete with nuts and bolts and clamps as per requirement for resting of HT transformer also includes providing and fixing of 8’x8’ chequered plate 6mm thick over the channels fixed with nuts and bolts. The job includes earthwork and concrete bottoming of sub-station as per requirement of site.
iv. Providing and fitting of lightening arrestor (Heavy duty, POST type).
v. Providing and fitting of set of drop out fuse set/ link set (2 Nos) (G.O.D) heavy duty providing and fixing of set of HT insulator.
vi. P/Fixing of disc insulators set.
vii. Providing and installation of cable termination kits and thimblings as per site requirement.
viii. Providing and fixing of anti-climbing devices.
ix. Other items like danger plates. The job includes providing/applying of metallic primer coat and two coats of enamel paint. Complete earthing of sub-station as per IEE rules. (Chemical earthing 3 Nos as per requirement and directions of in charge Engineer to accessories of sub-station)
x. Manufacturing, installation and commission of , 100KVA (2 Nos One as Standby), oil cooled three phase, outdoor type 11/0.433 KVA conventional (non-seated) type distribution, transformer shall have core type construction, suitable for outdoor system as stop down transformer. The primary winding shall be connected in the delta and secondary winding in star with symbol (DYLL). The neutral of separate insulated terminal. The core shall be built up of high grade chrome annealed silicon steel laminators having low loss and coated with firmly with channeled frame to prevent noise and vibrations.
The LV winding shall be circular and concentric with HV winding on the outside. The arrangement of winding should be robust in elect./ mechanical construction and should permit free circulation of oil to avoid hot spots. Adequate bracing shell be provided so that a strong self-supporting coils is obtained, no tapes shall be provided in the Winding Electrical grade epoxy dotted or other suitable insulations both for LV and HV windings. The transformer tank shall be made out of MS Sheet of minimum thickness 3.15mm thickness for sides and 5m thicknesses for top and bottom plate, suitable to withstand extreme pressure conditions. Primary coating and two coats of enamel paint should be duly painted on the tank. The transformer shall have a conservator tank provided with a drain plum-filling hole with cover. The cover shall be with 75x49 mm channel, with holes to make them suitable for mounting on plate/ plinth. The transformer tank shall be fitted with new 11 KVA grade T oil up to specific mark, the earthing terminals, two lifting lungs, rating and terminal marking plate, bi-metallic terminal connection for High Voltage/ Low V voltage side bushing level gauge, breather, duly valve should be provided to the transformer.
Original Manufacturer’s Test certificates in original to be provided with the material before installation.
Note:- The Electrical connection from the concerned PDD Department should be done by the firm in all respects. | 1 | JOB | 4,25,000 ₹4,25,000 | 4,50,000 ₹4,50,000 | 1,95,000 ₹1,95,000 Lowest |
| 8.00 | HT POLES
Providing and Errection of 9 Mtrs long M S Tubular poles having reducing dia of 6’’x 5’’ x 4’’ from bottom to top. The job includes P/F of 5 feet long cross arm ISMC-75, cross brace 1m x 40mmx 5mm, 3 no. HT insulators with pins to each pole. The job also includes spiral earthing, painting of poles in silver colour, grouting of poles in CC blocks of (1:1 ½:3) mix, P/F of danger plate indicating (11000V-DANGER) & P/F of nuts and bolts of assorted size.
The job also includes P/F of 8` long ISMC-75 Chanels 3 Nos at the tapping point with three No HT Insulaters. | 4 | JOB | 20,000 ₹80,000 | 34,000 ₹1,36,000 | 18,000 ₹72,000 Lowest |
| 9.00 | LT CONDUCTOR
P/Laying of aluminum conductor 0.05 ACSR with all head loads and lifts etc | 400 | Mtr | 67 ₹26,800 Lowest | 310 ₹1,24,000 | 70 ₹28,000 |
| 10.00 | Control Panel
Fabrication providing and fitting of Modular control panel of Appropriate size fabricated out of 16 SWG sheet having required openings/vents and protection class: IP 55 and fitted with accessories as under:-
a) Incomer = 250 A (MCCB)
Qnty = 1 No
Make = L&T / Siemens/ABB
No of poles = 4
Rated operational voltage = 415V ± 15%
Rated Frequency = 50± 3% Hz
Ambient temperature = 40 deg c
Ultimate S.C circuit Breaking capacity
At (425 AC 50 HZ = 36 kA
Thermal release range = 125-160 A
b) Change over switch
Make = L&T/Siemens/ABB
Qnty = One No
Type = CO2-125 4 pole
Rating = 125A
c) Distribution Bus Bar
Electrical grade Al with red, Blue and yellow tapping of Adequate section.
Rating = 200 A
d) Circuit Breaker = 100 A (MCCB)
Qnty = 2Nos
Make = L&T / Siemens/ABB
No of poles = 3
Rated operational voltage = 415V ± 15%
Rated Frequency = 50± 3% Hz
Ambient temperature = 40 deg c
Ultimate S.C circuit Breaking capacity
At (425 AC 50 HZ = 36 kA
Thermal release range = 100-125 A
e) Auxiliary circuit Breaker = 100 A (MCCB)
Qnty = 1 No
Make = L&T / Siemens
No of poles = 4
Rated operational voltage = 415V ± 15%
Rated Frequency = 50± 3% Hz
Ambient temperature = 40 deg c
Ultimate S.C circuit Breaking capacity
At (425 AC 50 HZ = 36 kA
Thermal release range = 80-100 A
On-off switches = 5 Nos (16 A)
Copper strips = 4 Nos (3 Nos for three phases and one No for Neutral)
f) Starters
Make = L&T
Rating = MU-G40
Power Specs = 3 phase, 425 ± 15 %
Qantity = 2nos
g) Ampere meter
Size = 96mm Sq
Range = 0-50 A
Make = L&T/Rishab
CT coils = Requisite 5 VA - 10 VA capacity 7 CT ratio
CT coil per meter = 2Nos (L&T)
Type = Analogoue
Qnty = 1 No (In Bus Bar Chamber)
with selector Switch
h) Voltmeter
Size = 96mm Sq
Range = 0-500 Volts
Make = L&T/Rishab
Type = Analogous
Qnty = 1 No (In Bus Bar Chamber)
With Selector Switch
I) Frequency meter
Qnty = 1 No (In Bus Bar Chamber)
Frequency meter = 0-50Hz
Type = Analogues
Make = L&T/Rishab/AE
J) Power factor meter
Qnty = 01 Nos
Type = Analogues
Make = L&T/Siemens/ABB
k) Neon Indicators
Qnty = 3 Nos 1 No (In Bus Bar Chamber)
The modular control panel shall have the dimensions and cabins as detailed in the enclosed drawings. The enclose shall be of excellent fit and finish, corrosion resistant treated and powder coated gliding hinges for smooth and noiseless movement. All the electrical joints in the panel shall be fitted with Belleville washers.
Original Manufacturer’s test certificates in original to be provided for all the accessories/ items required for Control Panel before its installation. | 1 | JOB | 1,50,000 ₹1,50,000 Lowest | 2,00,000 ₹2,00,000 | 1,50,000 ₹1,50,000 Lowest |
Tender Value
₹3.0 Cr
Closing Date
7 Feb 2022, 4:00 pmClosed
Executive Engineer
MINI SECTRAIT
Augmentation and commissioning of water supply scheme Matipora Ajas by way of providing , laying and fixing of G.I Pipes, construction of 0.30 lac gallon service Reservoir, sump cump pump house , Chowkidar /operator quarter, bathroom, sluice
2022_IFC_156690_1
79 of 2021-22
Open Tender
Civil Works
Item Rate
Bandipore
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
28 May 2022
12 Jan 2022
10 Feb 2022
12 Jan 2022
7 Feb 2022
12 Jan 2022
Amount
Supply, Installation, Testing & Commissioning of 40 kVA – 3 Phase D.G. The DG Set shall be comprising of diesel engine and alternator coupled together and fitted with standard accessories, control panel, battery, ant vibration pads, MS canopy duly painted and conforming to noise pollution specifications/ requirements of environmental protection rules 1986 as laid down by Ministry of Environmental (Protection) and Forest – read with GSR-371(e) Dated:17-02-2002 and GSR 520(E) Dated: 01-07-2003 in respect of emission norms for the engine and in respect of the noise level for the DG Set read with up to date amendments. The engine shall conform to IS/10000/BS649/BSS5514. The DG Set should be rated for continuous duty with overload provision of 10% for the period not exceeding one hour in twelve hours. DETAILS AS PER ESTIMATE
Submersible Pumping Unit: Providing, fitting, installation, testing and commissioning of submersible pumping unit of following specifications: Pump: Discharge of the Pump = 7000 GPH Dynamic Head = 145 M Speed = 2900 RPM Mat. Of the impeller = Steel Alloy Efficiency = Not less than 60 % Shaft Material = Stainless Steel Fluid to be handled = Water with solutes Motor: Rating = Corresponding to the head and discharge not less than 30 HP. Frequency = 50Hz Working Voltage = 415 ± 15% Efficiency = Not less than 60% Make = KSB/ Kirloskar/Pluga The job also includes providing and fitting of suitable dia nipple of mild steel having length 2.5’ duly threaded up to suitable length at one end and flanged at the other end. The job includes providing and fitting of mild steel crate around the pump and motor. Along with 2.5” MS clamps 01 Nos. fabricated out of MS sheet of 20mm thick and reducer 4x3” MS. Original Manufacturer’s Test certificates in original to be provided with the material before installation. Following Test Certificates of Original Manufacturer shall be furnished with the pumping equipment. - Performance test certificate - Laboratory test - Overload test - Insulation resistance test - High voltage test - Leakage current test
Column Pipes: Providing, fabrication, installation and testing of 65mm dia MS column pipe (15 Nos. 10 feet each in length), flanged (14mm Thick flange with grove cutting for 16sq mm submersible cable) and provided with necessary brackets and gaskets etc as per sample.
Control Valves and delivery manifold: Providing, installation, testing and commissioning of DI control valve viz, 1. 65mm dia Sluice valve (PN 1.6) --- 02 No. 2. 65mm dia NRV (PN 1.6)----04 No. Make: VAG/ TALIS/Sigma flow The job includes cutting of pipe at site and fitting of the above valves as per requirement includes all required fittings viz. 14mm thick flanges, Bends gaskets, nut bolts etc.
Servo Stabilizer: Cooling Oil Cooled (Servo Stabilizer) Capacity 100 KVA Input Voltage 160-480 Volts (Phase to Phase) 90-270 Volts (Phase to Neutral) Output Voltage 400 Volts ± 1% (Phase to Phase) 230 Volts ± 1% (Phase to Neutral) Type Suitable for: 100% Balance Load 100% unbalanced Supply Application Indoor Type Standard IS 2026 & IS 9815 Phase 3-Ph, 4 Wires Ingress Protection IP 55 Frequency 50 Hz Wave Form Distortion Nil (Negligible) Response Time Instantaneous (mili sec.) Speed of Correction 20 to 60 V/sec (as required) Mode Of Operation Automatic/Manual Suitability Suitable for all Power Factors. Duty Cycle Continuous 24 Hrs. Efficiency More than 98% Losses at No Load 0.4% of the total capacity Losses at Full load 1.9% at full load. Temp. Rise 45°C Deg.Cent. Above Ambient. Laminations Used Imported Low Losses CRGO Laminations - M4 Grade. Copper Used “Sterlite” Make- 99.9% Pure Electrolytic Grade. Carbon Brushes Used Imported High Grade Graphite Class of Insulation Class - A, Greater than 6M ohms Break Down Strength 2500v AC for 1 minutes (for Transformer) Construction The unit will comprise of 3 Nos. Individual Single Phase Unitsof 1/3rd of the total capacity connected in star configuration. Further, each of the three phases will further comprise of following: In Each Phase In Complete Servo 1 No. Digital Micro Controlled Processor Based Control Card with elegant push buttons for operations. 3 No’s 1 No. AC Synchronous Servo Motor 3 No’s 1 No. Copper Wound motorized variable auto transformer, wound on toroidal CRGO laminations with High quality graphite carbons for smooth functioning. 3 No’s 1 No. Buck n Boost series transformer. 3 No’s General Arrangements: All the above will be incorporated inside high quality epoxy painted sheet steel tank fitted with cooling radiators and mounted on unit-directional wheels, other fittings would include as follows Lifting Lugs Earthing Terminals – 2 No’s Oil filling valve Oil Level Indicators Rating Plate Name Plate Terminal Arrangement: Cable box suitable for Input & Output armoured cables of appropriate rating. Suitable Aluminium bus bars/terminals will be provided. with stem type terminals For auxiliary connections. Protections The Servo Voltage stabilizer must be fitted with the following protection devices. Over voltage Protection trip. Under voltage trip. Time delayed operation Overload trip Short Circuit protection. Single Phase Protection. Phase reversal Protection. The job includes providing/ installation/ testing and commissioning of 200 A Change over switch for connecting the Stabilizers. The specifications of the Change over switch are as follows: The job includes Providing, Installation, testing and commissioning of 3 phase, 200A, manually operated changeover switch. The job shall include proper thimbling of the terminals of the conductor as input to the equipment and the outgoing copper terminals from the switch of desired specifications at site. The other broad band specifications of the changeover switch are given as under: a. Type: Manual Changeover in Sheet Steel Enclosure b. No. of poles: 4 c. Rated Voltage: 415V d. Rated Current: 200 Original Manufacturer’s Test certificates in original to be provided with the material before installation.
Sub Station: The construction of Sub Station includes: i. Providing and erecting of four numbers of steel tubular poles 9m (SP33, ISI mark HTL-IS 1161 or IS-2713) with base plate 350mmx350mmx5mm long as per the latest IEE rules for fabricating 04 pole structure (with 2 NO. 9m SP33 poles and 02 No. 150mm dia 8mm thick pipes cut to adjust the height of the station bed as per site engineers instructions. ii. Fabrication, providing and fitting of ISMC-100 (as per the drawing attached). iii. Providing, fabrication and fitting of ISMC-150 pieces 8 feet long each 12 Nos. complete with nuts and bolts and clamps as per requirement for resting of HT transformer also includes providing and fixing of 8’x8’ chequered plate 6mm thick over the channels fixed with nuts and bolts. The job includes earthwork and concrete bottoming of sub-station as per requirement of site. iv. Providing and fitting of lightening arrestor (Heavy duty, POST type). v. Providing and fitting of set of drop out fuse set/ link set (2 Nos) (G.O.D) heavy duty providing and fixing of set of HT insulator. vi. P/Fixing of disc insulators set. vii. Providing and installation of cable termination kits and thimblings as per site requirement. viii. Providing and fixing of anti-climbing devices. ix. Other items like danger plates. The job includes providing/applying of metallic primer coat and two coats of enamel paint. Complete earthing of sub-station as per IEE rules. (Chemical earthing 3 Nos as per requirement and directions of in charge Engineer to accessories of sub-station) x. Manufacturing, installation and commission of , 100KVA (2 Nos One as Standby), oil cooled three phase, outdoor type 11/0.433 KVA conventional (non-seated) type distribution, transformer shall have core type construction, suitable for outdoor system as stop down transformer. The primary winding shall be connected in the delta and secondary winding in star with symbol (DYLL). The neutral of separate insulated terminal. The core shall be built up of high grade chrome annealed silicon steel laminators having low loss and coated with firmly with channeled frame to prevent noise and vibrations. The LV winding shall be circular and concentric with HV winding on the outside. The arrangement of winding should be robust in elect./ mechanical construction and should permit free circulation of oil to avoid hot spots. Adequate bracing shell be provided so that a strong self-supporting coils is obtained, no tapes shall be provided in the Winding Electrical grade epoxy dotted or other suitable insulations both for LV and HV windings. The transformer tank shall be made out of MS Sheet of minimum thickness 3.15mm thickness for sides and 5m thicknesses for top and bottom plate, suitable to withstand extreme pressure conditions. Primary coating and two coats of enamel paint should be duly painted on the tank. The transformer shall have a conservator tank provided with a drain plum-filling hole with cover. The cover shall be with 75x49 mm channel, with holes to make them suitable for mounting on plate/ plinth. The transformer tank shall be fitted with new 11 KVA grade T oil up to specific mark, the earthing terminals, two lifting lungs, rating and terminal marking plate, bi-metallic terminal connection for High Voltage/ Low V voltage side bushing level gauge, breather, duly valve should be provided to the transformer. Original Manufacturer’s Test certificates in original to be provided with the material before installation. Note:- The Electrical connection from the concerned PDD Department should be done by the firm in all respects.
HT POLES Providing and Errection of 9 Mtrs long M S Tubular poles having reducing dia of 6’’x 5’’ x 4’’ from bottom to top. The job includes P/F of 5 feet long cross arm ISMC-75, cross brace 1m x 40mmx 5mm, 3 no. HT insulators with pins to each pole. The job also includes spiral earthing, painting of poles in silver colour, grouting of poles in CC blocks of (1:1 ½:3) mix, P/F of danger plate indicating (11000V-DANGER) & P/F of nuts and bolts of assorted size. The job also includes P/F of 8` long ISMC-75 Chanels 3 Nos at the tapping point with three No HT Insulaters.
LT CONDUCTOR P/Laying of aluminum conductor 0.05 ACSR with all head loads and lifts etc
Distribution Cables: Providing, Installation, testing of multi-stranded copper conductor PVC insulated single core unsheathed 35mm sq. Copper cable for internal distribution wiring. The multi-stranded copper cable to be laid through PVC conduits on wooden plain boards fixed on walls with suitable plugs, nails and clamps. The job also includes termination of ends of cable with suitable rating of Cu. thimbles duly taped.Original Manufacturer’s Test certificates in original to be provided with the material before installation. Make: Havells/ National/Standard/Plaza/Imperial/ RR Kables.
Service Cables: Providing, laying, installation and testing of 3.5 Core, 95 sq. mm. Aluminum Conductor, PVC insulated, armored cable from distribution box of Transformer to the voltage stabilizer at both stages of the scheme. Job also includes providing and installation of aluminum Thimblings of appropriate ratings (24 No.) duly crimped and taped.Original Manufacturer’s Test certificates in original to be provided with the material before installation. Make: Havells/ Polycab/ Finolex/RR Kables
Motor cables: Providing, laying and testing of flat 3 core copper 16 sq mm submersible cable. The cable shall be PVC insulated and impermeable to grease, water and abrasion resistant. The job includes providing of copper thimblings as per requirements. Original Manufacturer’s Test certificates in original to be provided with the material before installation. Make: Finolex/ Polycab/ Havells
Gantry: Over Head Gantry Fabrication / Erection of Channel iron column to act as support for resting of monorail crane as per following details:- Vertical Posts = ISMC 150 No. of vertical posts = 02 Nos. Vertical channel section each post = 02 Nos. vertical post bracing = ISMC 100 Sole / Matching plates = 500x300x12 mm Height of vertical posts = 4.5 M size of vertical post concrete blocks = 600x600x900mm Concrete grade = M20 welding Electrode = Overcord SS of Adore/ESAB/L&T Monorail Section = ISMB 200 length of monorail = 5M Steel Detail : i. ISMC 150 6Mx2x2 = 24 M @ 16.4kg/m = 393.6 kg ii ISMC 100 0.25Mx10x2x2 = 10 M @ 9.2kg/m = 92 kg iii Plate 0.500x0.300x8 (12mmthk) = 1.20 M²(12thk) = 112.80 kg iv Monorail ISMB 200 5 M @ 25.4 kg/M = 127kgs v Bolts/Nuts (L.S) = 20 kgs Total = 745.4 kg = 750 KG say Supply, Installation of 3 ton capacity motorised chain hoist with hook suspension having following specifications:- Make = INDEF (HERCULES BABY-KEH) Capacity = 3 ton Hoisting speed = 2.4 M/Min Hoist motor H.P = as per requirement No. Of chain falls = 4 Min. Height of lift = 3 M MONORAIL = As per requirment Note:- All descriptive data given above is approximate, intended to give general idea of the product. The equipment be supplied as per the latest parameters / specifications. The chain hoist shall also have the following characteristics:- 1. Motor:- The basic drive of the hoist be provided with 3 phase squired cage totally enclosed induction motor having a high starting torque with class “F” insulation. The make of the motor be NGEF / SEIMNS / GEC/ Crompton and conform to IS : 325 (RPM-1500) 2. Brake:- The hoist shall have instant action, Fail to safe electromagnetic disc brake mounted on the end of the motor to ensure minimum safety and reliability when the load is held in its position as soon as the supply to the motor is switched off internally or accidentally. The adjustment & maintenance of break shall be quick and simple. 3. Gears:- The hoist shall have precision cut super and helical gears made of alloy steel mounted on bearings and housed in a dust proof gear box. The lubrication of gears be of high viscosity and temperature for longer life of gears. 4. Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. 5. Load chain wheel:- Specially designed, perfectly machined wheel providing correct grip of load chain made of malleable cast iron makes the hoist most safe and reliable against any failure. 6. Lifting Hook:- The lifting hook shall be forged with provision for free swivelling. 7. Limit Switch :- The limit switch shall have snap action, shunt type prevent over hoisting or over lowering to ensure maximum safety of operation. 8. Control:- The unit shall be controlled by heavy duty air break direction reversing type contractors and electrically inter – locked for safety. Contactors relay, fuses, low voltage transformer be fitted for control voltage and are to be housed in fabricated / pressed sheet steel box dust proof. 9. Push button pendent:- The contactors shall be operated by a pendent push button station suspended from hoist by a rope / dog chain to prevent any damage to the pendent cable and for easy operation. Test:- The hoist supplied is to be tested at 25% overload and the test certificate of the same be provided at the time of installation. The complete unit as specified above is required to be fitted / tested at site. Complete painting of fabricated structure by way of applying of two coats of red oxide as primer and then painting with enamel paint of any shade with two coats (powder coated).
Illumination and other amenities: -Providing, manufacturing, installation and fitting of heat resistant toughened glass 60W LED street lights (02 Nos.) with following specifications: Power Consumption/ Rating = 60W Make = Havells/ Vinay/ Bajaj/ Syska Housing/ Bogy = Single piece Pr. Die cast Aluminum Alloy complete non dimmable, environmental friendly, weather proof, excellent aesthetics. Operating voltage = 140- 270V, 50Hz The street lights to be fixed on the galvanized steel poles (02 nos to be provided), octagonal type 8m each complete with required MCB (02 nos.) of 10 amperes, required cable of 1.5mm2 (copper wire multi stranded type) from MCB to light through PVC conduits. The MCBs to be housed in MS boxes. The steel poles to be provided with 2 MS arms for each pols for housing street lights. The job also includes providing, installation, fitting and testing of 40W LED lights (01 No.) with heat resistant toughened glass with following specifications: Power Consumption/ Rating = 40W Make = Havells/ Vinay/ Bajaj/ Syska Housing/ Bogy = Single piece Pr. Die cast Aluminum Alloy complete non dimmable, environmental friendly, weather proof, excellent aesthetics. Operating voltage = 140- 270V, 50Hz The job also includes providing and fitting of MCB of 10 amperes, required cable of 1.5mm2 (copper wire multi stranded type) from MCB to light through PVC conduits. The job also includes providing and installation of 5 No. 12 Watt LED Lamps along with holders and switches and fitting by providing 1.5 sq. mm copper wire as per site requirement. Providing and installation of 16 A sockets along with 4 sq mm copper wire as per site requirements. All wires, to be laid through double U channels along with clamps, screws and other accessories. -Providing and fitting of inverter cum battery (180AH) with 5 No inverter lumps with all accessories like wire holder, channels ,switches and lumps. -Providing of solar/ electrical lantern both chargeable in solar/electrical (Indus/Tata) (01 No.). -Providing of bedding including mattress, pillows, blankets and utensils as amenities to the pumping station staff as per requirements. Providing of tool kit consist of following items Spanner set = 12 pieces of size 4/5,6/7,8/9,10/11,12/13,14/15,16/17,18/19, 21/23,24/26,24/27,30/32 Ring set = 12 pieces of same size as above Pliers = 2 No`s (tappari/ jalani) Cutting pliers = 2 No`s(tappari/jalani) Screw driver = 2 No`s (tappari/jalani) Hammer = 1 no of size 1 kg Pipe wrench = 2 Nos of size 12 inches Mutimeter = 1 No L Keys = one complete set
Earthing: Chemical Earthing of all the electrical equipment’s like transformer, lightening arrestor, sub-station using Electrode as per load, 2 Meters long connected with desired sized Aluminum internal strip complete with excavation, civil works, cast iron cover with back fill compound as required. The said earthing pit shall be completed taking into account the load of the equipment’s installed at site in consideration, included is installation of required sized Aluminum strips from earthing station to all the installed equipment’s with all desired items required.
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil
Ordinary Rock
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:
Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil :
Supplying and stacking at site, Graded crushed stone aggregate of size, 90 mm to 45 mm with Stone screening of size, 13.2 mm and 11.2 mm nominal size (Type A), including laying of stone dust / Moorum as binding material including laying of water bound macadam sub-base with brick aggregate and binding material, earth etc. including screening, sorting, spreading to template and consolidation with power road roller 8-10 tonne capacity etc. complete inclusive of all carriages upto site of work complete job
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)
Dry random rubble masonry with hard stone in foundation and plinth: With bond stone
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore
Above 40 mm nominal bore
Providing G.I. pipes complete with G.I. fittings Medium weight class B excluding trenching and refilling etc. (external work)incld. Carraige by mechanical means :-100mm dia G.I pipe
100mm dia class A light weight conforming to IS: 1239 part ist
80mm dia class A light weight conforming to IS: 1239 part ist
Providing and fixing G.I. pipes complete with G.I. fittings light weight class A excluding trenching and refilling etc. (external work) conforming to IS: 1239 part ist incld carraige by mechanical means:-50mm dia G.I pipe
40mm dia G.I pipe
25mm dia G.I pipe
20mm dia G.I pipe
15mm dia G.I pipe
Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work:- 50mm dia G.I pipe
40mm dia G.I pipe
25mm dia G.I pipe
Providing and fixing of 14mm thick M.S flanges G.I pipe incld. Cost of flanges, rubber gaskets, nuts bolts, welding charges cutting of threads excld. Earth work and refilling: 100mm dia
Providing and fixing of 12mm thick M.S flanges G.I pipe incld. Cost of flanges, rubber gaskets, nuts bolts, welding charges cutting of threads excld. Earth work and refilling: 100mm dia
80mm dia
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions incld. Tailpeices ,tapers, Gi pipe etc. complete 50mm dia
25mm dia
100mm dia Non Return Valve
Providing and fixing of CI sluice valve with cap including all accessories like nuts, bolts rubber insertion etc and tail pieces of Kirloskar make including successful testing and commissioning. 100mm dia
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore
50 to 80 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm nominal bore
65 mm nominal bore
Constructing masonry Chamber of specified size, in brick work with common burnt clay (non modular) bricks of class designation 7.5 incement mortar 1:4 (1cement :4 coarse sand) and R.C.C. top slab 1:1.5:3mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mmnominal size ) including necessary xcavation, foundation concrete1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. For sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid. Chamber 120x120x100 cm
Dumping stone including cost of stones. in Horizontal on level
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m
Providing & laying stone soling in horizontal on level.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:- 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing & fixing of main hole cover 0.75 x 0.75 of standard quality with angle iron frame incld all necessary fittings complete
Providing & fixing of main hole cover 0.90 x 0.90 of standard quality with angle iron frame incld all necessary fittings complete
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete Welded
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platforms
Lintel, beams, plinth beams, girders, bressumers and cantilevers
Arches, domes, vaults upto 6 m span
Extra for shuttering in circular work
Extra for shuttering in circular work: foundation
Extra for shuttering in circular work: Lintels/beams
Extra for shuttering in circular work: Lintels/beams
Extra for shuttering in circular work: suspended floors
Edges of slabs and breaks in floors and walls : Under 20 cm wide
Columns, pillars, piers, abutments, posts and struts.
Providing and fixing of 50mm dia G.I half bend of standard quality to be fixed in dome for aeration purpose
Providing and incorporating PGI sheets strips 0.8mm thick at construction joints incld. All carriages complete job
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
12mm Cement plaster finished with a floating coat of neat cement of mix:1:3 (1 cement 3 sand)
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shutteringand finishing with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Supply and filling GSB (granular sub-base) in layer not exceeding 22cm in thickness & aggregate size does not exceed 90mm incld. carriage
Providing & laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length hold fast lugs or with dash fasteners shall be paid for separately): Second class kail wood
Providing and fixing glazed shutters for , windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). First class kail wood (35mm)
Providing and fixing of 4mm thick Float glass panes(weighing not less than 10 kg/sqm
Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete. Galvanized M.S wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete Second class Kail wood
Providing and fixing of panneled 40mm thick doors of of first class kail wood incld all sorts of carraige complete
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2
Providing & fixing colour corrigated ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2
Providing and fixing plained eaves boarding (Kail wood). 250x32 mm (nominal size )
Providing and fixing of Gsheet soffit of approved quality , colour and texture complete
providing & fixing of Anchor bolts of 16mm dia 9"long
Providing and fixing of of Hardware items Aldrops 150mm dia
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Tower bolt ( 150x10 mm ) long
Tower bolt ( 100x10 mm ) long
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125mm
Air hooks
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. ( 2 mm thick )
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.75litre/10sqm of approved brand and manufacture
Providing and fixing of GI pipes complete with G.I fittings & clamps incld. cutting & making good etc complete
Providing and fixing of pvc pipes, cables with all pvc fittings incld. trenching and refilling etc (external with flateral 100mm dia pvc pipe) along with bends, sockets etc (prince quality)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work
Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge Long pattern W.C Pan of size 580x440 mm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes including all associated fittings and the base support for tank [Sintex, Electroplast, Star, Lotus or equivalent having valid lSI license]
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (wall / floor tiles)
Providing & fixing of stainless steel sink incls waste pipe
Providing and fixing of electric and heating points including wiring for lightning points in 1.5 sq. mm, PVC insulated copper wire and 2.5 sq. mm PVC insulated multi strand copper wire, 6mm one way switches, 2 mm thick PVC conduit/ channel with bends, junction boxes etc 6amp S pole MCS, 10 Amp DP MCB, 2 way for housing MCB, hylan sheet with wooden box recessed in walls with accessories complete: Lighting point
Heating point
Fan with dimmer
Exhuast Fan 12" x12"
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Applying priming coat:- With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat)
Painting with aluminum paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Providing and mixing of water proofing material or equivalent for RCC work
Providing and fixing of nuts ,bolts and chips incld one end fix to anchor block
Providing and fixing of PVC pipes for aeration purposes
Welding, including transportation of plant at site etc. complete By electric plant
provision for temporary diversion of water
Providing and fitting of 1 No. water Gysers, 2 No. water mixers. 4 No. Bibcock s, Mirrors, Jugs/ mugs & other bathroom accessories etc
Providing and fitting of bedroom items Floor mating, 01 No. beds with necessary beding and mattresses , 01 no. wardrobes for cloths, 1 no. locker, 4 chairs and one table, Utensils gas with gas stove etc
Provision for Providing and fixing of pipe specials of standard quality incld. testing complete
Carraige of materials from source to road site of work including loading , unloading and stacking:-- Stone / stone soling for an av lead of 15 km
40mm aggregate for an av lead of 35 km
20mm aggregate for an av lead of 35 km
sand for an av lead of 35km
cement for an av lead of 10 km
steel for an av lead of 10 km
Bricks for an av lead of 80 km
Carraige of materials from road site to site of work by manual labour including loading , unloading and stacking for an av lead of 300 Mtrs. Stone / stone soling
40mm aggregate
20mm aggregate
Cement
Steel
Bricks
100mm dia GI pipes for an av lead of 500 mtr
Providing, erecting and fixing of sign board 2'6''x4' made up of angle iron frame work 50x50x6mm with 1mm thick M.S sheet including priming, painting and proper lettering and embeding with 1:3:6 cement concrete complete job
M/s Mohammad Shafi Mir
Dar and Sons
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
BOQ_351848.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .