Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC D 822 1 FLOOR SARASWATI VIHAR PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | ₹18.7 L | L1 | Accepted-AOC As per Financial Bid |
| 2 | L2₹26.9 LRejected-Finance Y 51 GROUND FLOOR OKHLA INDUSTRIAL AREA PHASE II DELHI 110020 | SOUTH EAST | DELHI | 110020 | ₹26.9 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹28.0 LRejected-Finance | ₹28.0 L | L3 | Rejected-Finance Being L3 |
| 4 | L4₹31.0 LRejected-Finance 9 C 8 SECTOR 7 SAI BABA CHOWK ROHINI NORTH WEST DELHI DELHI 110085 UDYAM DL 06 0006352 07AALCS7473H1ZU B R M MII STATUS AS VERIFIED | NORTH WEST DELHI | DELHI | 110085 | ₹31.0 L | L4 | Rejected-Finance Being L4 |
| 5 | L5₹36.3 LRejected-Finance RAR 107A GROUND FLOOR RAJENDRA ARIHANT TOWER B1 COMMUNITY CENTRE JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | ₹36.3 L | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | PYROGUARD ENGINEERS PRIVATE LIMITED L6 | advent electric technologies pvt. ltd. L2 | Nexus Fire And Security Systems L5 | SVS Buildwel Pvt Ltd L4 | CENTRE TAP ENGINEERING L7 | SUPREMEX EQUIPMENTS L3 | Surendra Infrastructure Pvt. Ltd. L8 | FOAMTECH ANTIFIRE PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | SITC of 1 Kg Automatic Direct Low Pressure Fire Suppression Extinguisher and Valve. Applicable on class A, B, C and electrically started fires.
Extinguishing Agent: 1 Kg Clean Agent FK-5-1-12 (UL Listed or FM approved) with zero Ozone Depletion Potential.
Fire Suppression Extinguisher Can: EPA & SNAP/PESO approved can, stored Pressure Type, deep drawn and argon welded , MS sheet metal of thickness withstanding 100% hydraulic pressure tested to 35 bars, Operating pressure 15 bar. Can as per IS:15683.
Cylinder Mounting Bracket.
Valve : The valve DLP is nickel plated brass , equipped with a pressure gauge to monitor the system pressure , with a ball valve interfacing the tubing and the cylinder , working pressure 10-15 bar, tested upto 35 bars.Valve shall be CE certified | 20 | Set | 22,680 ₹4.5 L | 28,000 ₹5.6 L | 27,950 ₹5.6 L | 22,275 ₹4.5 L | 33,000 ₹6.6 L | 28,500 ₹5.7 L | 40,500 ₹8.1 L | 17,900 ₹3.6 L |
| 2.00 | SITC of 2 Kg Automatic Direct Low Pressure Fire Suppression Extinguisher and Valve. Applicable on class A, B, C and electrically started fires.
Extinguishing Agent: 2 Kg Clean Agent FK-5-1-12 (UL Listed or FM approved) with zero Ozone Depletion Potential.
Fire Suppression Extinguisher Can: EPA & SNAP/PESO approved can, stored Pressure Type, deep drawn and argon welded , MS sheet metal of thickness withstanding 100% hydraulic pressure tested to 35 bars, Operating pressure 15 bar. Can as per IS:15683.
Cylinder Mounting Bracket.
Valve : The valve DLP is nickel plated brass , equipped with a pressure gauge to monitor the system pressure , with a ball valve interfacing the tubing and the cylinder , working pressure 10-15 bar, tested upto 35 bars.Valve shall be CE certified | 13 | Set | 25,570 ₹3.3 L | 38,000 ₹4.9 L | 33,450 ₹4.3 L | 24,975 ₹3.2 L | 35,000 ₹4.5 L | 31,500 ₹4.1 L | 44,000 ₹5.7 L | 19,700 ₹2.6 L |
| 3.00 | SITC of 4 Kg Automatic Direct Low Pressure Fire Suppression Extinguisher and Valve. Applicable on class A, B, C and electrically started fires.
Extinguishing Agent: 4 Kg Clean Agent FK-5-1-12 (UL Listed or FM approved) with zero Ozone Depletion Potential.
Fire Suppression Extinguisher Can: EPA & SNAP/PESO approved can, stored Pressure Type, deep drawn and argon welded, MS sheet metal thickness thickness withstanding 100% hydraulic pressure tested to 35 bars, Operating pressure 15 bar. Can as per IS:15683. Cylinder Mounting Bracket.
Valve : The valve DLP is nickel plated brass , equipped with a pressure gauge to monitor the system pressure , with a ball valve interfacing the tubing and the cylinder , working pressure 10-15 bar, tested upto 35 bars.Valve shall be CE certified | 4 | Set | 27,250 ₹1.1 L | 48,000 ₹1.9 L | 44,250 ₹1.8 L | 30,375 ₹1.2 L | 40,000 ₹1.6 L | 35,600 ₹1.4 L | 52,500 ₹2.1 L | 22,900 ₹91,600 |
| 4.00 | SITC of Heat Sensing Tube for automatic fire detection and suppression system made by special modified Polyamide (PA) color Red RAL 300 , High grade HR quality, , UV Stabilized , inner diameter 4mm , outer diameter 6mm , melting point approx :- 220 degree Celsius when heating up with 10 K/minute, burst pressure 100 bar at 20oC . Temperature grade minus 40oC to + 80oC. Working Pressure 20 Bar at 20oC. Burst Temperature: When pressurized with dry Nitrogen at 15 bar pressure approx 100oC to 110oC, UL approved as per UL521 standard (or equivalent FM approved) for heat detectors for fire protective signaling systems.Loop Clamps shall be used to secure the sensor tube from the walls of the panel/mounting surface.Including pressurizing tube @ 15 Bars using Nitrogen pressurizing agent.
Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell | 1,500 | Meter | 990 ₹14.8 L | 800 ₹12 L | 1,075 ₹16.1 L | 810 ₹12.2 L | 1,500 ₹22.5 L | 650 ₹9.8 L | 1,199 ₹18.0 L | 424 ₹6.4 L |
| 5.00 | SITC of T connection , Brass , Nickel plated , for 4 x 6 mm Sensor Tube , quick and easy disassembly using special tool , working pressure 15 bars at 15 Deg temperature , temperature range -40 oC till +80oC, Elastomeric sealings , External diameter tube 6mm.
Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell | 90 | Job | 1,080 ₹97,200 | 400 ₹36,000 | 910 ₹81,900 | 1,283 ₹1.2 L | 2,500 ₹2.3 L | 800 ₹72,000 | 2,899 ₹2.6 L | 1,079 ₹97,110 |
| 6.00 | SITC of End of Line Plug for Automatic fire detection and suppression tube used for fitting at the tube end to terminate the point. Fitting made by brass nickel plated material with elastomeric sealings, Temperature range TS -20oC till +60oC, Maximum working pressure 25 Bars , made as per PED pressure equipment directives.
Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell | 90 | Job | 860 ₹77,400 | 200 ₹18,000 | 590 ₹53,100 | 743 ₹66,870 | 1,000 ₹90,000 | 600 ₹54,000 | 2,199 ₹2.0 L | 399 ₹35,910 |
| 7.00 | SITC of End of Line adaptor with pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube includes check valve, Pressure gauge and fitting to connect to sensor tubing. Tube connection 6mm, length 2.77"/71mm, gauge scale; 0-20 bar. Fitting made by brass (plated / unplated) , Stainless Steel , elastomeric sealings , copper Nickel plated , Temperature range TS -20oC till +60oC, Maximum working pressure 25 Bars , made as per PED pressure equipment directives.
Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell | 37 | Job | 3,680 ₹1.4 L | 1,200 ₹44,400 | 1,750 ₹64,750 | 1,688 ₹62,456 | 4,500 ₹1.7 L | 1,500 ₹55,500 | 4,799 ₹1.8 L | 1,099 ₹40,663 |
| 8.00 | SITC of pressure switch to monitor pressure drop in the tube , switch point 5 Bars, switch type SPST, Normally Open/closed , Electric Rating 120/ 240 VAC-375 VA, 24 VAC - 125 VA , Open 160 psi y-7 , Close 185 psi y-5 , Pressure switch + adaptor /5 bar/ M10x1.It should be CE certified
Filling Adapter to pressurize the Heat Detection Tube with quick coupling connector and threaded end-of-line connection | 37 | Job | 9,200 ₹3.4 L | 800 ₹29,600 | 5,100 ₹1.9 L | 3,321 ₹1.2 L | 10,000 ₹3.7 L | 6,298 ₹2.3 L | 6,599 ₹2.4 L | 2,249 ₹83,213 |
| 9.00 | SITC of Master control unit for the operation of above items Upon receiving notifications from the system pressure switch due to activation, the MCU shall provide outputs for activation of sounders or to third party devices which may be used for Notification.
Outputs: Low pressure (Fault), System activation (Fire)
Input: Pressure Switch
Notification: 12V output for Sounder
Main Power: 230V AC
With Battery Backup & Sounder
Interface system with main control fire alarm system(Inclusive of Wiring)
The system should have means to switch off the exhaust fans if installed in the panel at the time of system activation
Including control/power cabling with 1.5sqmm Cu cable with cable clamps/ties backed by 6A MCB
Approved Makes: Siemens / Eaton / Hochiki / Bosch / Apollo / Ravel /Autronica(UTC)/ Edwards(UTC)/ Honeywell/Kidde (UTC)/ GST (UTC)/ System Sensor/ Morley IAS/ Group4/ Mather & Platt/ Minimax | 37 | Nos. | 20,000 ₹7.4 L | 3,200 ₹1.2 L | 12,250 ₹4.5 L | 16,875 ₹6.2 L | 12,000 ₹4.4 L | 7,800 ₹2.9 L | 22,900 ₹8.5 L | 7,400 ₹2.7 L |
Tender Value
₹60.2 L
EMD Value
₹1.2 L
Closing Date
10 Jun 2024, 6:00 pmClosed
AGM (E-E)
VSI Airport, Port Blair
Fire suppression system for HT/LT panel at NITB VSI Airport, Port Blair
2024_AAI_195811_1
AAI/PB/Engg(E)/FSS
Open Tender
Electrical Works
180 days
VSI Airport, Port Blair
Please refer Tender documents.
19 documents required · 19 mandatory
₹1,120
₹1.2 L
2 Apr 2026
18 May 2024
12 Jun 2024
18 May 2024
10 Jun 2024
28 May 2024
19 May 2024 - 27 May 2024
Amount
SITC of 1 Kg Automatic Direct Low Pressure Fire Suppression Extinguisher and Valve. Applicable on class A, B, C and electrically started fires. Extinguishing Agent: 1 Kg Clean Agent FK-5-1-12 (UL Listed or FM approved) with zero Ozone Depletion Potential. Fire Suppression Extinguisher Can: EPA & SNAP/PESO approved can, stored Pressure Type, deep drawn and argon welded , MS sheet metal of thickness withstanding 100% hydraulic pressure tested to 35 bars, Operating pressure 15 bar. Can as per IS:15683. Cylinder Mounting Bracket. Valve : The valve DLP is nickel plated brass , equipped with a pressure gauge to monitor the system pressure , with a ball valve interfacing the tubing and the cylinder , working pressure 10-15 bar, tested upto 35 bars.Valve shall be CE certified
SITC of 2 Kg Automatic Direct Low Pressure Fire Suppression Extinguisher and Valve. Applicable on class A, B, C and electrically started fires. Extinguishing Agent: 2 Kg Clean Agent FK-5-1-12 (UL Listed or FM approved) with zero Ozone Depletion Potential. Fire Suppression Extinguisher Can: EPA & SNAP/PESO approved can, stored Pressure Type, deep drawn and argon welded , MS sheet metal of thickness withstanding 100% hydraulic pressure tested to 35 bars, Operating pressure 15 bar. Can as per IS:15683. Cylinder Mounting Bracket. Valve : The valve DLP is nickel plated brass , equipped with a pressure gauge to monitor the system pressure , with a ball valve interfacing the tubing and the cylinder , working pressure 10-15 bar, tested upto 35 bars.Valve shall be CE certified
SITC of 4 Kg Automatic Direct Low Pressure Fire Suppression Extinguisher and Valve. Applicable on class A, B, C and electrically started fires. Extinguishing Agent: 4 Kg Clean Agent FK-5-1-12 (UL Listed or FM approved) with zero Ozone Depletion Potential. Fire Suppression Extinguisher Can: EPA & SNAP/PESO approved can, stored Pressure Type, deep drawn and argon welded, MS sheet metal thickness thickness withstanding 100% hydraulic pressure tested to 35 bars, Operating pressure 15 bar. Can as per IS:15683. Cylinder Mounting Bracket. Valve : The valve DLP is nickel plated brass , equipped with a pressure gauge to monitor the system pressure , with a ball valve interfacing the tubing and the cylinder , working pressure 10-15 bar, tested upto 35 bars.Valve shall be CE certified
SITC of Heat Sensing Tube for automatic fire detection and suppression system made by special modified Polyamide (PA) color Red RAL 300 , High grade HR quality, , UV Stabilized , inner diameter 4mm , outer diameter 6mm , melting point approx :- 220 degree Celsius when heating up with 10 K/minute, burst pressure 100 bar at 20oC . Temperature grade minus 40oC to + 80oC. Working Pressure 20 Bar at 20oC. Burst Temperature: When pressurized with dry Nitrogen at 15 bar pressure approx 100oC to 110oC, UL approved as per UL521 standard (or equivalent FM approved) for heat detectors for fire protective signaling systems.Loop Clamps shall be used to secure the sensor tube from the walls of the panel/mounting surface.Including pressurizing tube @ 15 Bars using Nitrogen pressurizing agent. Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell
SITC of T connection , Brass , Nickel plated , for 4 x 6 mm Sensor Tube , quick and easy disassembly using special tool , working pressure 15 bars at 15 Deg temperature , temperature range -40 oC till +80oC, Elastomeric sealings , External diameter tube 6mm. Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell
SITC of End of Line Plug for Automatic fire detection and suppression tube used for fitting at the tube end to terminate the point. Fitting made by brass nickel plated material with elastomeric sealings, Temperature range TS -20oC till +60oC, Maximum working pressure 25 Bars , made as per PED pressure equipment directives. Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell
SITC of End of Line adaptor with pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube includes check valve, Pressure gauge and fitting to connect to sensor tubing. Tube connection 6mm, length 2.77"/71mm, gauge scale; 0-20 bar. Fitting made by brass (plated / unplated) , Stainless Steel , elastomeric sealings , copper Nickel plated , Temperature range TS -20oC till +60oC, Maximum working pressure 25 Bars , made as per PED pressure equipment directives. Approved Makes: Vivina / Ases / shootfire(Vimal) /Lifeguard (UnitedFire)/ Ceasefire /kalpex(Kalpataru) /Foamtech/supremex /Ansul/LPG/Hygood/Firetrex(SVS)/ Honeywell
SITC of pressure switch to monitor pressure drop in the tube , switch point 5 Bars, switch type SPST, Normally Open/closed , Electric Rating 120/ 240 VAC-375 VA, 24 VAC - 125 VA , Open 160 psi y-7 , Close 185 psi y-5 , Pressure switch + adaptor /5 bar/ M10x1.It should be CE certified Filling Adapter to pressurize the Heat Detection Tube with quick coupling connector and threaded end-of-line connection
SITC of Master control unit for the operation of above items Upon receiving notifications from the system pressure switch due to activation, the MCU shall provide outputs for activation of sounders or to third party devices which may be used for Notification. Outputs: Low pressure (Fault), System activation (Fire) Input: Pressure Switch Notification: 12V output for Sounder Main Power: 230V AC With Battery Backup & Sounder Interface system with main control fire alarm system(Inclusive of Wiring) The system should have means to switch off the exhaust fans if installed in the panel at the time of system activation Including control/power cabling with 1.5sqmm Cu cable with cable clamps/ties backed by 6A MCB Approved Makes: Siemens / Eaton / Hochiki / Bosch / Apollo / Ravel /Autronica(UTC)/ Edwards(UTC)/ Honeywell/Kidde (UTC)/ GST (UTC)/ System Sensor/ Morley IAS/ Group4/ Mather & Platt/ Minimax
advent electric technologies pvt. ltd.
SUPREMEX EQUIPMENTS
SVS Buildwel Pvt Ltd
Nexus Fire And Security Systems
PYROGUARD ENGINEERS PRIVATE LIMITED
CENTRE TAP ENGINEERING
Surendra Infrastructure Pvt. Ltd.
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Tender.pdf
Tender Documents • 23.93 MB
BOQ_214318.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid