Electrification work in connection with Provision of bore well and HS tank of 50KL for PFs water taps & pipeline at VRBD, BTSR, in Mathura-Palwal section BSA and PRK stations Mathura-Achhnera section.
ELG-29R-J06-2026-27
ELG-29R-J06-2026-27
Open
8 Months
Mathura, Uttar Pradesh
₹0
₹55,700
16 Jun 2026
16 Jun 2026
24 Jun 2026
1- Electrification work in connection with Provision of bore well and HS
Supply, laying, testing and commissioning of with material fixing and providing the Light/ FTL/C.Fan /E.Fan concealed wiring point with 2.5 Sq.mm PVC insulated and sheathed multistrand copper wire 1100 V grade, single core with 1.5sq.mm. PVC insulated copper conductor 1 for continuous earthing in recessed steel/PVC conduit pipe 25mm. 1.6mm.thick dia bend, junction box etc. with ceiling rose batten holder, flush type 5A. switches mounted on white laminated phenolic sheet 3mm. thick cover on front of MS box made of 18 S.W.G. MS sheet of suitable size complete with replastering of wall if required wiring to be done in separate circuit. (Concealed wiring to be done on walls and roof if RCC roof is already constructed surface through PVC casing caping good quality double lock type wiring may be done.
"Supply, Erection, Testing & Commissioning of Supply of material for fixing and providing 5 pin socket outlet point (3 pin + 2 pin) 5-A/230 V. with flush type 5 Amp. Socket combined 2 type with switch in concealed wiring by 2.5 Sq. mm. PVC insulated multistranded copper wire single core 1100 V. Gr. in recessed steel conduit pipe 25 mm. dia & 1.6mm. thickness with 5 Amp. /230 V. flush type switch fixed on white phenolic laminated sheet 3mm. thick cover on front of MS box of suitable size complete including 1.5 Sq. mm. PVC insulted copper conductors for earthing and replastering of wall. "
Supply, erection, Testing &Commissioning of concealed wiring point of 6 pin (3 pin 15Amp. + 3 pin 5 Amp.) power socket flush type 15 A/5 A -230 V. comprising of switch 15 Amp. & 3 recessed MS conduit wiring or in casing caping PVC double lock type of good quality with suitable wooden board well polished by 4 sq. mm. PVC insulated multistrand copper cable 1100 V. grade single core including 1.5 sq. mm. PVC insulated copper conductor for earth wire, mounted on white phenolic laminated sheet 3mm. thick cover on front of MS box 1.6mm thickness complete with replastering of wall. (Separate circuit to be drawn from SDB.)
Supply, Erection, Testing and commissioning of MS/PVC conduit pipe 25mm dia and 4 1.6mm thick, recessed in the wall and through the wall by making hole and replastering the same in original condition complete with Tee, elbow, junction box, sadle & Other accessories for sub main wiring.
Supply, erection, Testing & Commissioning of sub main consisting of 2x4 Sq. mm (P & 5 N) PVC insulated and sheathed copper wire multristanded single core 1.1KV grade alongwith 1.5 Sq. mm PVC insulated copper wire 1.1 KV grade for earthing. (Quantity 1 Mtr. Equal to 02 Nos., wire of 4 Sq.mm of 01 Mtr.each. and 01 No. earth wire 1.5 Sq. mm. of 01 M) (No cable joint is permitted inside the MS conduit pipe cable should be jointed with cable connectors inside the switch board)
"Supply, erection, Testing & Commissioning of energy efficient luminaire complete 6 with all accessories , 18/20 watt, 04 feet LED tube light fitting & Tube with suitable current control driver circuit, suitable for surface mounting and connection with PVC copper flexible wire of 23/76 as per Rly. specification attached "
Supply, erection, testing and commissioning of single earth electrode of 50mm. dia 7 3000mm long GI pipe class B conforming to IS: 1239 latest complete with earth box with cover as per RDSO approved drawing including connection from earth electrode to MDB/ SDB/poles/with 8 swg GI wire
Horizontal boring of cable duct at 1.4 to 2.1 mtr.depth from the bottom of sleeper 8 /ground lable and laying of 120 mm dia HDPE DWC pipes for cable crossing under track / road .The work shall be done as per extant practice and instruction of site engineer.It includes supply of DWC/HDPE pipes conforming to IS14930(Part:2:2001)
Excavation of cable trench:- This item shall be operated in conformity with IS:1255 (latest version) i.e. code of practice for installation and maintenance of HT/LT cables. The price shall cover cost of excavation of cable trench in all type of soil for laying LT cables and back filling the same with sieved earth and finishing the surface in its original condition after providing sand, & bricks in cross position. For LT/HT cables the trench shall be 600mm wide x 1000mm deep. In trench 9 the cable shall be covered with river sand at a depth of 100mm below the cable and 100mm above the cable than placing well-burned bricks continuously in cross-position through out the cable route in the ground. The bottom of the trench should level free from stones and sharp edge of rocks etc. At the termination a loop of 5 meter (approx) cable shall be kept as allowance and loops rings be formed as per the site condition, in the ground, The cost shall include the cost of all materials i.e. sand, bricks, cable route markers (grouted in the earth firmly with cement concrete so that it can not be uprooted by miscreants) etc at 25m. interval and each turn of the cable.
"Laying/Cleating erection, Testing & Commissioning of HT/LT Cable 03/04 Core on wall with all accessories & refilling of cable trench (as per IE rule) after laying of cable (Cable will be supplied by Rly free of cost at Cosignee Depot) "
Supply, Erection, Testing and commissioning of water proof flat Submersible cable 11 size 3 core X 6 Sqmm copper conductor 1.1KV grade PVC insulated & Sheathed conforming to IS- 694/1994 (latest) to be laid from starter to well cable to be laid through MS conduit pipe ( Heavy gauge ) of suitable size with fixing accessories.
Supply Erection, Testing & Commissioning of control panel wall mounted type made of 16SWG MS Sheet duly painted with double coat of stove enameled paint and one coat of primer paint, dust proof, vermin proof with locking arrangement and comprising of the following Items duly mounted on Bakelite sheet (05mm. thick) of suitable size . 1. Fully automatic star/delta starter 415 12 V.3Phase-15HP to 20HP 2. Over load relay range 16- 25. 3. Electronic single phase preventer with in built 45 ± 5 Sec. facility. 4. Motor on/motor 'TRIP' Neon lamps. 5. Auto/Manual switch. 6. By pass switch for SPP. 7. Am meter size 96 x 96mm. range 0 - 100 A. with selector switches (03 Nos.) 8. Voltmeter size 96 x 96mm range 0 - 500 V. AC 9. Motor 'ON'/Motor 'OFF' push button. 10. Incomer TP miniature circuit breaker 40 A. 11. Three phase (R,Y,B) Neon lamps. 12. Volt meter selector switch (VSS) 13. Connector strip. 11 way. 14. No. volt coil voltage 250 V. - 440 V. 15. Timer 1-30 Sec.
Supply, Erection, Testing and commissioning of Submersible cable 3 core X 16 Sqmm
supply, erection, Testing & Commissioning of energy efficient LED street light fitting 14 60 Watt outdoor complete street light fitting pressure die cast aluminum (PDC) body with make embossed on PDC body and complete with all accessories/ components and connection with PVC copper wire 2.5sq. mm size multicore and fixing arrangement as per site requirement. The technical parameters will generally conform to relevant Railway specification attached Annexure-II
Supply, erection, Testing & Commissioning of constructed, Installation Testing and Commissioning of Maintenance Free Earth as per RDSO Spec.No.RDSO/SPN/197/2008 or latest consisting the following , A) Copper bonded steel electrodes of 3.0 meter long & 17.2mm.dia with Cu-bonding thickness of min.250 microns and UL listed and marked=1No. B) Earth enhancement material supplied in sealed bags of in.10Kgs.=3Nos. C) Copper strip 150x25x6 mm. to terminate earth rod=1No. D) Copper strip 300x25x6 mm. Main LT panel board to terminate earth rod =1No E) Copper strip 150x25x6 mm. Sub distribution board to terminate earth rod =1No F) Digging the earth to the required depth G) Insertion of electrode H) Filling of earth enhancing compound (30Kg.) - provision of exothermic weld connection on copper tape of 25mmx6mm.x150mm.to the earth electrodes all the materials, tools and features required for the weld to be arranged by the 15 contractor-1No. Note:-Earth pit should be prepared as per RDSO. DRG. No.SDO/RDSO/L&B/001 I) Provision of Exothermic weld connection in copper tape 25mm.x6mm.x150mm. to the earth electrodes . All material, tools and features requires for the weld to be arranged by the contractor J) Provision of Exothermic weld connecting ,One to connect 35 Sq.mm multistranded single core PVC insulated copper cable to the copper tape welded to the earth electrode and another to the copper tape (Main LT panel board) to be fixed inside the equipment / Escalator apparatus room, weld materials, tools and features and all other materials requires for the weld to be arranged by the contractor K) Electrode termination in a concrete sink and routing the cadmium cable to bus bar in equipment room ( all other materials required for the work shall be done by the contractor Note:- Earth resistance should be less than One Ohm. L) MDB & SDB are to be installed in equipment/Panel room and earth connections to equipment cables extended from LT panel board and Sub distribution board as the case may be .
Supply Erection, Testing & Commissioning of heavy duty uPVC column pipe, blue screened (one side threaded and having rubber seal & one side having inbuilt inner threaded socket and rubber seal, dia 90 mm. (3 inch), effective length 3m. Per pipe with all fixing accessories
Supply Erection, Testing & Commissioning of Top & Bottom adaptor set of stainless steel suitable for 3" dia uPVC pipes.
Supply, Erection, Testing and commissioning of SIGRI (Lowering jig) suitable for 2'' diameter PVC pipe
Supply, Erection, Testing and commissioning of SIGRI (Lowering jig) suitable for 3'' diameter PVC pipe
Supply, Erection, Testing and commissioning of Super Nylon Rope 12mm conforming to IS: 4572: 2104 (Latest).
Supply, Erection, Testing and commissioning of Electrically Driven Submersible pump Set 4/5 star rated water lubricated of following capacity 3 phase 50Hz 415 Volt AC Supply capacity 10 HP, Discharge Size 75mm dia suitable for 200mm bore as per site requirement
Supply, Erection, Testing and Commissioning of MS Nonreturn valve suitable for 100mm dia pipe
Supply, Erection, Testing and commissioning of Pump Guard set (Flange, 19mm SS rods & PVC SM Piece) Suitable for 3'' diameter pumps
Supply, Erection, testing and commissioning of PVC Pipe bend/Elbow of size 150mm X 150mm, type of elbow bend angle 90
Supply, Erection, testing and Commissiong of PVC Pipe bend/Elbow of size 100mm X 100mm, type of elbow bend angle 90
Supply, Erection, Testing and commissioning of Foot value of size 100mm lift type as per IS: 4038 (latest)
Supply, Erection, Testing and commissioning of Foot value of size 150 mm lift type as per IS: 4038 (latest)
Supply, Erection, testing and commissioning of Submersible pump 3 Phase 4/5 star rated 99 meter head discharge 110 LPM, minimum power 05 HP
Supply, Erection, testing and commissioning of submersible pump control panel for above submersible pump with O/L relay and other protective devices with switch gears from the list referred.
Supply, Erection, Testing & Commissioning of wall mounted Sub Distribution Board (Light/power) TP&N Vertical Three Phase wall mounting type 4 way peari ivory dust and vermin proof 30 in door type factory fabricated from sheet steel enclosure (1.6 mm. thick ivory colour) 04 way fitted with double door copper bus bar, neutral link, earth terminal detachable glands fitted with following item. (SDB make as per attached approved list) 01 No. 125Amp. 50 KA MCB TPN on incoming side. 12 Nos 16 to 32Amp. MCB-SP- on out going side. "
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril202227-04-2022.pdf
ATTACHMENT
GCCACScorrectionslip1.pdf
ATTACHMENT
Correction slip 02
ATTACHMENT
Correction slip 03
ATTACHMENT
Correction slip 04
ATTACHMENT
Correction slip 05
ATTACHMENT
Correction slip 06
ATTACHMENT
Correction slip 07
ATTACHMENT
Correction slip 08
ATTACHMENT
Correction slip 09
ATTACHMENT
Correction slip 10
ATTACHMENT
correctionslipNo.-02GCC13-12-22.pdf
ATTACHMENT
CorrectionslipNo.-03ofGCC-2022.pdf
ATTACHMENT
GCCCorrection07-08-2023SlipNo.4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-8.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-9.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-10.pdf
ATTACHMENT
ACS-11.pdf
ATTACHMENT
Shramikkalyan.pdf
ATTACHMENT
Letterofcredit.pdf
ATTACHMENT
AnnexureC.pdf
ATTACHMENT
AnnexureVA1Policy.pdf
ATTACHMENT
TenderDocument.pdf
ATTACHMENT
Download all tender documents and submit your bid