Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | ₹26.5 L Quoted ₹27.3 L | L1 | Accepted-AOC Accepted. Being the L1 bidder. |
| 2 | L2₹30.2 LRejected-AOC | ₹30.2 L | L2 | Rejected-AOC Rejected as not being the lowest bidder. |
| 3 | L3₹32.0 LRejected-AOC | ₹32.0 L | L3 | Rejected-AOC Rejected as not being the lowest bidder. |
| 4 | L4₹34.5 LRejected-AOC | ₹34.5 L | L4 | Rejected-AOC Rejected as not being the lowest bidder. |
| 5 | L5₹36.4 LRejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹36.4 L | L5 | Rejected-AOC Rejected as not being the lowest bidder. |
| Sl No | Description | Qty | Unit | NOEL ENGINEERS L2 | R J ENTERPRISES L5 | Shree Ayyappa Engineering L6 | cooltech engineering services L8 | SAI SERVICE L3 | Radha Engineering Services L4 | PAUL REFRIGERATION L1 | Anjali Constructions L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. | 710 | Per Point | 5 ₹3,550 | 25 ₹17,750 | 42 ₹29,820 | 50 ₹35,500 | 5 ₹3,550 | 30 ₹21,300 | 1 ₹710 | 38 ₹26,980 |
| 2.00 | Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) | 80 | Each | 5 ₹400 | 50 ₹4,000 | 40 ₹3,200 | 50 ₹4,000 | 5 ₹400 | 40 ₹3,200 | 1 ₹80 | 42 ₹3,360 |
| 3.00Material and Labour for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with all fittings, accessories, PVC junction boxes etc fixed to walls/ceilings with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting modular switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following:- | |||||||||||
| 3.01 | (a) One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed | 140 | Per Point | 580 ₹81,200 | 650 ₹91,000 | 810 ₹1.1 L | 850 ₹1.2 L | 525 ₹73,500 | 750 ₹1.1 L | 400 ₹56,000 | 810 ₹1.1 L |
| 3.02 | (b) Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed | 10 | Per Point | 620 ₹6,200 | 750 ₹7,500 | 860 ₹8,600 | 870 ₹8,700 | 300 ₹3,000 | 750 ₹7,500 | 400 ₹4,000 | 860 ₹8,600 |
| 3.03 | (c) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed | 50 | Per Point | 80 ₹4,000 | 150 ₹7,500 | 195 ₹9,750 | 200 ₹10,000 | 175 ₹8,750 | 210 ₹10,500 | 100 ₹5,000 | 230 ₹11,500 |
| 3.04 | (d) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed | 55 | Per Point | 580 ₹31,900 | 850 ₹46,750 | 810 ₹44,550 | 850 ₹46,750 | 525 ₹28,875 | 750 ₹41,250 | 400 ₹22,000 | 810 ₹44,550 |
| 3.05 | (e) One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed | 10 | Per Point | 650 ₹6,500 | 750 ₹7,500 | 950 ₹9,500 | 1,000 ₹10,000 | 550 ₹5,500 | 750 ₹7,500 | 700 ₹7,000 | 950 ₹9,500 |
| 3.06 | (f) One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed | 5 | Per Point | 580 ₹2,900 | 650 ₹3,250 | 800 ₹4,000 | 850 ₹4,250 | 550 ₹2,750 | 750 ₹3,750 | 400 ₹2,000 | 800 ₹4,000 |
| 3.07 | (g) One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed | 40 | Per Point | 580 ₹23,200 | 650 ₹26,000 | 810 ₹32,400 | 850 ₹34,000 | 525 ₹21,000 | 750 ₹30,000 | 400 ₹16,000 | 810 ₹32,400 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
31 Jan 2026, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
PREVENTIVE MAINT AND REPAIR INTERNAL ELECTRIC SUPPLY INTERNAL POINT WIRING AND CONNECTED WORKS OF MD ACCN AT MO (MB) GHATKOPAR UNDER GE (NW) BHANDUP
2026_MES_748022_1
8473/B
Open Tender
Civil Works
270 days
MO (MB) GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹70,000
Yes
5 Jun 2026
10 Jan 2026
2 Feb 2026
10 Jan 2026
31 Jan 2026
24 Jan 2026
10 Jan 2026 - 20 Jan 2026
Taking down carefully unserviiceable copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Material and Labour for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC casing caping with all fittings, accessories, PVC junction boxes etc fixed to walls/ceilings with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame suitable for mounting modular switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following:-
(a) One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
(b) Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed
(c) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
(d) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
(e) One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed
(f) One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
(g) One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed
Description all as per Item No 3 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade, for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
Description all as per Item No 3 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through existing PVC/ Steel concealed conduit with and including concealed GI metal boxes 1.2 mm thick,(18 Guage) 50mm deep, with earth dolly, covered with modular white cover plate & frame of suitable module for mounting modular switches, sockets, regulators etc and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following:-
(a) One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
(b) Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed
(c) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
(d) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
(e) One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed
(f) One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
(g) One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed
Description all as per Item No- 6 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
Description all as per Item No-6 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
Note for Item Ser No 3 to 8: (i) Cutting chases for conduits and sinking's for GI metal switch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department. (ii) Partially partly wiring in casing caping with all fittings accessories PVC junction boxes whereever concealed wiring is not possible on the surfaces of RCC slab / ceiling /columns / beams etc shall deemed to be included in the unit rate quoated against item.
Supply and fixing Modular switch, one way 6 A, one module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular switch, Two way 6 A, one module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular Bell push 6A ,one module 230 Volts complete all as specified and as directed.
Supply and fixing Modular switch, one way 16 A, one module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular socket outlet multipurpose, 6A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular socket outlet multipurpose, 6A/16A - 2/3 pin combined 2 module, 230 Volts complete all as specified and as directed.
Supply and fixing Modular socket outlet multipurpose, 6A/16A - 2/3 pin combined with 16 Amps MCB 4 module, 230 Volts complete all as specified and as directed.
Supply and fixing Switch piano, flush type, polycarbonate, single pole, one way 6 Amp complete all as specified and as directed.
Supply and fixing Bell push, flush type, polycarbonate, 6 amp complete all as specified and as directed.
Supply and fixing Switch piano, polycarbonate, flush type single pole, one way 16 Amp complete all as specified and as directed.
Supply and fixing Socket outlet switch socket outlet, 2-in-1, 6 pin, 6 and 16 Amps, flush type complete all as specified and as directed.
Supply and fixing Socket outlet 2 in 1, 5 pin, 6A complete all as specified and as directed.
M & L Switch socket combination 2 in 1, 6 pin, 6 A flush type complete all as specified and as directed.
M & L Switch socket combination 6A/16A, 6 in 1 flush type complete all as specified and as directed.
Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified and as directed.
Supply and fixing electric Buzzer, Ding Dong bell suitable for operation on AC. 230 volts, single pole complete all as specified and as directed.
Material and Labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit with all fittings, accessories, PVC junction boxes etc.with and including concealed PVC switch, socket, regulator mounting, SAC-WHT-JBX1, 86 Size, ( HSN 85365020) junction box. Make Jaquar or equivalent and also including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following
(a) One light point/ exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed
(b) Two light point controlled by one, one way switch 6 Amps on the same switch circuit complete all as specified and as directed
(c) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed
(d) One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed
(e) One two way light point controlled by two nos. two way 6A switches complete all as specified and as directed
(f) One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
(g) One ceiling fan point & regulator controlled by one, one way switch 6 Amps complete all as specified and as directed
Description all as per Item No 25 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
Description all as per Item No 25 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
Note for Item 25 to 27: (i) Cutting chases for conduits and sinking's for PVC switch boxes and making good to walls in cement mortar 1:3 to match with existing surfaces shall be carried out by the contractor without any extra cost from the department. (ii) Partially partly wiring in casing caping with all fittings accessories PVC junction boxes whereever concealed wiring is not possible on the surfaces of RCC slab / ceiling /columns / beams etc shall deemed to be included in the unit rate quoated against item.
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16AX one gang one way switch and face plate in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SWG-WHT-PC16A1G01 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16AX Two gang one way switch and face plate in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SWG-WHT-PC16A2G01 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16AX Three gang one way switch and face plate in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SWG-WHT-PC16A3G01 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16AX Two gang two way switch and face plate in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SWG-WHT-PC16A2G02 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16AX Three gang two way switch and face plate in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SWG-WHT-PC16A3G02 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 16A Door bell one way switch and face plate in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SWG-WHT-PC16A1GB1 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 1 Gang 16A switched socket with indicator and face plate in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SKG-WHT-PC16ASC1GS1 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White I Gang 2 & 3 Pins universal switched socket with indicator in one complete with Terminal screw in ready for wiring Make Jaquar Cat No- SKG-WHT-PC16AUSDS1 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White, 1 Gang, 2 & 3 Pin universal socket with indicator & 2.1 A double USB port in one complete with Terminal screw in ready for wiring Make Jaquar Cat No SUB-WHT-PC16AUSD2B00 or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 1 Gang Fan speed controller switch in one complete with Terminal screw in ready for wiring Make Jaquar Cat No- SWG-WHT-PC1ARFSS or Equivalent in Legrand
Supply and fixing High strength, flame retardant, fade-resistant Poly Carbonate, Easy on-off, White 1 Gang Energy saving card switch in one complete with Terminal screw in ready for wiring Make Jaquar Cat No- SFH-WHT-PC16AES0H or Equivalent in Legrand
M & L Ceiling rose, 3 terminal /PVC/ polycarbonate, isolated body complete all as specified and as directed.
M & L Lamp holder, PVC/ Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed.
M & L Fancy Lamp holder, PVC/ Polycarbonate type with back plate of brass terminal suitable for batten fittings complete all as specified and as directed.
Supply and fixing 6 Amps Top Plug with Indicator complete all as specified and as directed.
Supply and fixing 16 Amps Top Plug with Indicator complete all as specified and as directed.
Supply and fixing TV Co - axial Socket - 01 Module complete all as specified and directed. Make- Legrand Cat No- 5734 25 or Equivalent in Havells.
Supply and fixing USB Charger - 3000mA/15 Watts - Type A + C -1 Module complete all as specified and directed. Make- Legrand Cat No- 5716 88 or Equivalent in Havells.
Supply and fixing 16A - Motor Starter - 2 Module complete all as specified and directed. Make- Legrand Cat No- 6794 71 or Equivalent in Havells cat No- AHRSMXW201
Supply and fixing 25 A - Motor Starter - 2 Module complete all as specified and directed. Make- Legrand Cat No- 6794 71 or Equivalent in Havells Cat No- AHRSMXW251
Supply and fixing 32 A - Motor Starter - 2 Module complete all as specified and directed. Make- Legrand Cat No- 6794 71 or Equivalent in HavellsCat No- AHRSMXW321
Supply and fixing in repairs Modular white cover plate with frame, to true size of the existing concealed metal box & make as per site requirement of
(a) 3 Module
(b) 4 Module
(c) 6 Module
(d) 8 Module
(e) 12/16 Module
(f) 18 Module
Supply and fixing in repairs GI metal flush boxes 1.2 mm thick, (18 Guage) 50mm deep, with earth dolly, suitable for mounting modular white cover plate of size
(a) 3 Module ( Make- Legrand Cat No - 6890 08 or equivalent)
(b) 4 Module ( Make- Legrand Cat No - 6890 09 or equivalent)
(c) 6 Module ( Make- Legrand Cat No - 6890 10 or equivalent )
(d) 8 Module ( Make- Legrand Cat No - 6890 42 or equivalent )
(e) 12/16 Module ( Make- Legrand Cat No - 6890 11 or equivalent)
(f) 18 Module ( Make- Legrand Cat No - 6890 12 or equivalent )
Supply and fixing in repairs Plastic Surface Box -, with earth dolly, suitable for mounting modular white cover plate of size
(a) 3 Module ( Make- Legrand Cat No - 6733 03 or equivalent )
(b) 4 Module ( Make- Legrand Cat No -6733 04 or equivalent)
(c) 6 Module ( Make- Legrand Cat No - 6733 06 or equivalent)
(d) 8 Module ( Make- Legrand Cat No -6733 08 or equivalent)
Supply and fixing 3mm thick white (Hylam) sheet for electrical application to incorporate switches, sockets etc including Cutting, drilling, shaping of material to site requirement and fixing with brass cadmium screws of adequate size and length complete all as specified and as directed.
Note for Item Ser No 39 & 52 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated. (ii) Making good disturbed wall in cement mortar 1:3 , & with wall puti for concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department
Supply and fixing Smart Glow intelligent office lighting recessed luminaire size 600mm x 600mm,36 Watt,220 V AC, with built in PIR occupancy sensor offering flexibility of auto switching off when the space is not occupied complete with standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Philips (Type- RC383B P LED 36S-6500 G6 PSU OD WH PIR P) or equivalent in Jaquar
Supply and fixing Full glow recessed LED luminaire size 600 mm x 600 mm, 35/36 watt, 220 V AC, deep drawn white powder coated CRCA housing, seamless front frame flat white high transmission acrylic cover, with high power uniform illumination soft glare LED'S and isolated driver, complete suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size & with standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Philips ( Cat No- RC380B LED36S-6500 G6 L60W60 PSU OD S1), or equivalent in Jaquar, crompton
Supply and fixing Energy efficient, Twinglow 25-Watt+25-Watt Led Up-Down Batten (Warm White + Cool White), polycarbonate material, 4' Tubelight fitting, 2500 Lumen complete with standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make-Philips (Product SKU : 919515813875) or equivalent in Jaquar, crompton
Supply and fixing wall/ surface mounted, LED- 35W ± 10% watt Power consumption, AL. Extruded Housing, 230 VAC, 50Hz batten fitting complete with standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Jaquar Cat No- HBT-WHT-LKBU4KVS35XC or equivalent in Philips,crompton
Supply and fixing wall/ surface mounted, LED-10 W watt Power consumption, AL. Extruded Housing, Input Voltage 140 V AC - 270 V AC, 50Hz, IP 20, batten fitting complete with standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make-Havells Cat No- LHEXACP7IN1W010 or Equivalent in Philips, Jaquar. Cat No- BTI-WHT-LGLZ01X010XW
Supply and fixing energy saving, Full Glow LED Surface Light luminaire complete with Motion Sensor, Power consumption 15 Watt, Round Shape, single Phase 230 Volt. fitting and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Philips ( Product SKU : 929003671501) or equivalent in Jaquar, Crompton.
Supply and fixing COB down (spot) light, Power consumption- 8 Watt, Input voltage 230 Volt AC, 50 Hz, Die Cast Aluminium with White/Black Powder Coating housing, recessed mounted fitting, and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Jaquar Cat No- IRL-WHT-LEMA01R008XC or equivalent in Philips, Crompton
Supply and fixing LED down light, Power consumption- 13.5 Watt, Input voltage 130-320 Volt, AC, 50 Hz, Aluminium die cast, White/Black Powder Coating housing, recessed mounted fitting complete with Highly efficient Electronic driver and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Philips Cat No- DN296B LED15S-6500 PSU WH or equivalent in Jaquar, Crompton, Orient
Supply and fixing LED down light, Power consumption- 18 Watt, Input voltage 130-320 Volt, AC, 50 Hz, Aluminium die cast, White/Black Powder Coating housing, recessed mounted fitting complete with Highly efficient Electronic driver and standard warranty of manufacturer from date of purchase/ installation all as specified and directed. Make Philips Cat No- DN296B LED20S-6500 PSU WH or equivalent in Jaquar, Crompton, orient
S & F for Decorative wall mounted luminaire fitting double arm with decorative glass shade suitable holder for LED bulb complete including Back up LED Bulb cool white, 10 watts-2 Nos , all as specified and as directed. Make Jaquar Cat Part No DWL-CHR-MB160275542A or equivalent in Philips- Product SKU : 919215850202 . Orient, Crompton.
S & F for Decorative wall surface mounted luminaire fitting single arm with decorative glass shade suitable holder for LED bulb complete including Back up LED Bulb cool white, 10 watts-01 No, all as specified and as directed. Make Jaquar Cat Part NoDWL-CHR-MB160275531B or equivalent in Philips.-Product SKU : 919215850401 Orient, Crompton.
S & F wall surface mounted LED Wall Lamp luminaire fitting Chrome Finsh with inbuilt 6W LED round focus spot light complete all as specified and as directed. Make :- Jaquar Cat Part No DWL-CHR-WL5048X6W or its equivalent
Supply and fixing wall surface mounted LED track, moveable base, round focus light luminaire fitting 30 W, fully adjustable beam Angle 40º Aluminium casing with inbuilt 30W LED complete all as specified and as directed Make Jaquar Cat No LTRLB1R030XW or equivalent in Philips, crompton, orient.
S & F Highly efficient LED Motion sensor Bulbs, 10 W, output of 900 lumens, cool white, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap, complete and standard warranty of manufacturer from date of purchase/ installation all as specified and directed.
S & F Highly efficient 12 Watt, B-22 , Back up LED Bulb cool white, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap, complete and standard warranty of manufacturer from date of purchase/ installation all as specified and directed.
Note for Item Ser No 53 & 67 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated.
Supply and fixing amp rating 240V, 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
(a) SP 5 To 32 AMP
(b) SPN 32 AMP
(c) SPN 40 to 63 AMP
Supply and fixing 415V 10KA 'C' curve, IP 20 protected terminals, miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning.
(a) TP 25 To 63 AMP
(b) TPN 16 To 32 AMP
(c) TPN 40 To 100 AMP
S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 100 Amps rated bus bar, Fully shrouded Neutral bars, Earthbar and Cable ties for Cable management, 240 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed.
(a) SPN 4 Way. (Make Legrand Cat No - 5076 10 orequivalent)
(b) SPN 8 Way. (Make Legrand Cat No - 5076 11 or equivalent).
(c) SPN 12 Way. (Make Legrand Cat No - 5076 12 or equivalent).
S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCB DB with 100 Amps rated bus bar for each phase, Fully insulated & shrouded Neutral bars, Earthbar and Cable ties for Cable management, & provision for FP MCB / Isolator / RCCB / RCBO as incomer and SP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and as directed.
(a) TPN 4 Way. (Make Legrand Cat No- 5076 80 or equivalent.)
(b) TPN 6 Way. (Make Legrand Cat No- 5076 81 or equivalent).
Supplied and fixed Flush Mounting and Surface Mounting single pole and neutral sheet metal enclosure suitable for 240 V with neutral link, two pin, earth plug and socket plug top complete all as specified and as directed with
(a) One Single pole MCB upto 20 Amps
S & F sheet metal enclosure suitable for Flush Mounting and Surface Mounting, MCCB DB with 250 Amps rated bus bar for each phase, Fully insulated & shrouded 2 Neutral bars, 2 Earthbar and Cable ties for Cable management, & With provision for DPX³ 250 MCCB as incomer and SP/TP MCB's as outgoing, 415 Volts, IP 43 - #IK 09 with metal double door & magnetic locking system including inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface in cement mortar to match the existing surface & colour to wall complete all as specified and as directed.
(a) VTPN 4 Way. (Make Legrand Cat No - 5077 58 orequivalent.)
(b) VTPN 8 Way. (Make Legrand Cat No - 5077 59 orequivalent).
Note for Item Ser No 68 & 73 : (i) Item will also be exercised in repairs means Labour component involved in taking out existing unserviceable from its place and fixing new in position is deemed to be included in the unit rate quoated. (ii) Making good disturbed wall in cement mortar 1:3 , & with wall puti for concealing meatl box and painting wall surface as per existing finish shall be carried out by the contractor without any extra cost from the department
Taking down carefully existing unserviceable main switch/ cutout/ DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed.
Supply and fixing DPX³ 160 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 100 Amps, of Make Legrand Cat No 4200 57 or Equivalent in L&T
Supply and fixing DPX³ 160 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 125 Amps, of Make Legrand Cat No 4200 56 or Equivalent in L&T
Supply and fixing DPX³ 160 MCCB with O/L & S/C thermal magnetic protection unit, 25 KA breaking Capacity, 4 Pole , 160 Amps, of Make Legrand Cat No 4200 57 or Equivalent in L&T
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into PVC casing caping with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into PVC casing caping with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into PVC casing caping with all fittings, PVC junction boxes etc and its accessories (ISI marked) of suitable size including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 4 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 4 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed.
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 6 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
M & L for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS multistranded copper conductor cable of size 10 Sqmm nominal area and drawing into existing surface / recessed, PVC / Steel conduit including PVC insulated multistranded copper conductor 10 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly complete all as specified and as directed. Note- Three run of 10 Sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
S & F PVC rigid non-metallic conduit of dia 20 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system complete all as specified and directed by Engineer-in- Charge
S & F PVC rigid non-metallic conduit of dia 25 mm dia inclusive of all tees, bends, elbows reducers, junction box etc and fixing accessories such as couplers, lock nuts, saddles, etc for telephone cable , TV cable and public address system complete all as specified and directed by Engineer-in- Charge
Supply and fixing Medium duty SS 304 CABLE PERFORATED TRAYS, rust proof, in standard length of 2.5 Mtr, thickness - 3.0 mm, and height of tray 50mm complete with side SS couplers plates to connect cable trays with each other, SS couplers cable tray bends, and supporting accessories of GI (Galvanized Iron) Threaded Rods, Fasteners, with nuts, bolts, washers etc for fixing cable tray on walls or hanging with ceilings all as specified and as directed complete width of
(a) Cable Tray 150mm
Note:- Supporting hanging/ wall fixing accesssories, shall be fixed at minimum length 01 Mtr span and will be measured as one length along with cable tray. Rate quoted shall deemed to be included in the unit rate quoted.
Labour for taking down of unserviceable ceiling fan of any sweep and make after disconnecting cable end terninal from ceiling rose, dismantling blades and hanging serviceable fan at same location of any sweep, make by connecting cable end terminal to ceiling rose, after fixing blades at site with fan, testing for smooth running complete all as specified and as directed.
Note : Transportation to & fro involved of unserviceable ceiling fan to deposit in EM Store yard Ghatkopar and back to site hanging serviceable fan after collecting from store is deemed to be included with unit rate.
Servicing/ over hauling of ceiling fan 230 Volts of any make and sweep, along with following others repairs. a). Dismantaling of ceiling fan complete part by part carefully, testing stator coils, degreasing bearing and display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts.
b) Heating & varnishing to stator coils with super quality varnish and dried out properely with external heat as ordered & directed. c) Reassembeling of ceiling fan complete with all existing serviceable parts obtained against Item 1 (a), and new parts as required / ordered by Engineer in Charge.
Note:- (i) Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoated against this Item. (ii).Any unforeseen minor repair and minor parts that are not covered under Item No-86 , (a) to (c) ( Total cost less than Rs 100 ) but required to complete the repair work / smooth functioning of fan shall be deemed to be included with the unit rate. (iii) Transportation of fan to workshop for repair and back to site in EM store yard at Ghatkopar is deemed to be included with unit rate. (iii). Rewinding of stator coils of ceiling fan , where involved shall be measured and paid separetely against relevant item of this schedule. (iv) 3 core PVC insulated and sheathed 0.75 Sqmm cable from ceiling rose to fan connector of adequate length (maximum upto 1 Mtr) and (greasing the bearing with ball bearing grease where involved) shall deemed to be included in the unit rate.
M & L for taking out old paint of ceiling fan (any size) with paint remover liquid , Preparing smooth surfaces for painting, cleaning all dust etc, filling cavities with filler, and Painting of complete ceiling fans including blades with synthetic enamel white rust proof paint by spraying complete all as specified and as directed.
S & F Ceiling fan down rods cut to required length as per site requirement of 15 mm dia GI pipe (medium grade) to the existing trusses of any height including necessary welding, drilling holes complete all as specified and as directed.
Material and Labour for Radium Retro Reflective Vinyl Sticker, (Thickness 0.4mm,) water proof, wear resistant back with sticker, Resistant to fading, cracking, and peeling, colour as directed by Engnr-in- Charge, (for MES Property Inenfification) Numbering Fan any type, cut to customizable size font - Height not less than 20 mm and width not less than 15 mm with letters as - GE (NW) / E&M / CF / 001 / MES- Ghatkopar complete all as specified and as directed. Note- Ser No i.e 001 will change on each ceiling fan as directed by Engnr-in- Charge.
Supply and fixing, fresh air (exhaust) fan plastic body of 250mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Ghatkopar complete all as specified and directed.
Supply and fixing, fresh air (exhaust) fan plastic body of 200mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Ghatkopar complete all as specified and directed.
Supply and fixing, fresh air (exhaust) fan plastic body of 150mm sweep, AC single phase, 240V, 50 Hz, Input Voltage, 140-285, , with louvers and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to PVC connector block of fan and taking down old exhaust fan carrying to deposit in AGE E/M store yard Ghatkopar complete all as specified and directed.
Taking down chowkat or frame ( Wooden) / Steel not exc. 1.5 sq. m and removing to store complete all as specified and as directed
Supply and fix extruded Powder coated Anodised aluminium section as in window, door, and ventilator shutters, fixed type without sash bar, (powder coating of any colour (Thickness or powder coating not less than 50 micron). with movable, openable or fixed type shutter or any pattern as directed, provision for exhaust fan opening & adjustable louvers, aluminium section weighing 0.55 kg/m including necessary glass 3mm thick ordinary quality, frosted joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, roller, handle, locks etc etc. complete all as specified
Supply and fixing LED light fitting 2 x 20 watt Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
Supply and Fixing LED Tube Light 20 Watt -4' suitable for flame proof Tube light fitting as in replacement with side holders complete all as specified and as directed
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including GI strip 25×4 mm as earthing lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel drawn through GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with precast RCC cover in CC 1:2:4 type B1 with handle , with G.I 20 mm dia medium grade pipe for watering and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts, check nuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed.
Note for Item No 106 to 107. Item cost includes cost of dismantling unserviceable earthing pit above ground level with earthing electrode and making good as per existing ground.
S&F LED indoor decorative aluminum housing LED batten integrated type tube light fitting, suitable and including wattage 20W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed.
S&F LED indoor decorative polycarbonate housing LED batten integrated type tube light fitting, suitable and including wattage 10W, rated input voltage 140V AC – 270V AC, driver efficiency 88%, Lumens efficiency 100 lm/W, starting voltage 90V, THD<=20, color rendering index (CRI).80, Color temperature 6500K, No harmful radiations, inbuilt surge protection 2.5 kV, isolation 3.75kV, Zero mercury content , complete with all accessories internally pre wired and including connected up with twin core twisted flexible copper conductor cable with suitable sizes all as specified and directed.
Supply and fixing in repair 2 x 2 ft LED ultra modern slim luminaire suitable for armstrong /grid ceiling, recess mounting luminaire complete ultra brite LED with very high efficacy of cap 36 W, 230V, all as specified and directed.
S & F in repairs heating element of 1.5 kw / 2.0 kw including rubber washer ISI marked any type complete all as specified and directed.
Taking down of water storage Gyser and refixing after repair at its own position or other location including new hlodfastner complete all as specified and directed.
S&F in repairs thermostat for water storage heater SP 230V complete all as specified & directed
S&F in repairs safety valve / high pressure release valve 15 mm dia ISI marked complete all as specified & directed
S&F in repairs indicator neon lamp 230 volts SP square or round complete all as specified & directed
S&F in repairs connection pipe of 45 cm long stainless steel anti slip technology,anti explosion design complete all as specified & directed
M & L for repair any type of defective electronic single Phase meter including any kind and type material and testing required complete all as specified and directed.
Supply and fixing in repairs highly efficient high power multi LED flood fitting 150 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 protection, PF>0.95, LED light luminous efficiency shall not be less than 90 Lumens/Watt and the colour rendering index shall not be less than 70 and Correlated Colour Temperature is 6500K and light should complying ISI and BIS marking complete prewired and connecting with 0.5 sqmm 3 core flexible wire including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Note:- To be fixed at min height of 12 m building / store house.
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP656,LEDs 100 watts power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting complete all as specified and directed. Note:- To be fixed at min height of 12 m building / store house
Taking down and opening / dismantling of exhaust/ ventilation fan, 200/250/300 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and re-fixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warranty will be one year. Note:- To be fixed at min height of 12 m building
All as per above item no.47 but size for 450 mm sweep Exhaust fan.
Supply and fix bearing Suitable for existing ceiling fan of 1200/1400mm sweep all as specified and directed
Supply and fix bush Suitable for existing exhaust fan of 200/250/300 mm sweep all as specified and directed
Supply and fix bush Suitable for existing ceiling fan 1200/1400mm sweep all as specified and directed
Supply and fix shaft Suitable for existing ceiling fan of 1200/1400mm sweep all as specified and directed
Supply and fix bearing Suitable for existing exhaust fan of 400 mm sweep all as specified and directed
Supply and fix bush Suitable for existing exhaust fan of 400 mm sweep all as specified and directed
Supply and fix bearing Suitable for existing exhaust fan 200/250/300 mm sweep all as specified and directed
Supply and fix shaft Suitable for existing exhaust fan 200/250/300/400 mm sweep all as specified and directed
Supply and fix capacitor 2.5/4 mfd capacity 230 volts all as specified and directed
Supply and fixing in repair 250/300 mm sweep PVC exhaust fan blade all as specified and directed.
Supply and fixing in repair exhaust fan motor 170 to 250V, 50 Hz (200 mm Sweep to 300 mm Sweep) suitable capacity and size all as specified and directed.
Supply and fixing in repair 250/300 mm sweep PVC exhaust lovers suitable for any size and model all as specified and directed.
Supply and fix capacitor 1.5 mfd capacity 230 volts all as specified and directed
Supply and fixing in repair 250/300 mm sweep 3 or 4 blade metal body fan blade suitable for any size and model all as specified and directed.
Supply and fixing in repair 250/300 mm sweep GI sheet exhaust lovers suitable for any size and model all as specified and directed.
Supply and fixing in repair 400 mm sweep GI sheet exhaust lovers suitable for any size and model all as specified and directed.
Supply and fixing in repair 400 mm sweep 4 blade metal body fan blade suitable for any size and model all as specified and directed.
Taking down and opening / dismantling of ceiling fan, 1200/1400 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warranty will be one year.
Taking down and opening / dismantling of BLDC ceiling fan, 1200/1400 mm sweep and taking out old unserviceable winding and M & L for rewinding the same with super enameled copper wire of existing/same gauge including all insulating material required as per standard practice, varnishing the same and drying, cleaning the fan bearing/bushing and greasing/oiling and reassembling, testing complete including spy painting with one coats of synthetic enamel paint after preparing rusted surface and refixing, testing and commissioning complete all as specified and directed by the Engineer-in-Charge. Note : 1) Spare parts like capacitor, bush and bearing will be measured and paid separately under respective items. 2) winding fan warranty will be one year.
Supply and fixing in repair BLDC fan control electronic card for 1200 mm sweep ceiling fan as per model all as specified and directed.
Supply and fixing in repair BLDC fan electronic remote for 1200 mm sweep ceiling fan as per model all as specified and directed.
Supply and fixing in repair Modular AC Box With 20A SP MCB, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top complete all as specified and directed.
M&L for the earthing test of through complete all as specified and directed by the Engineer-in-charge.
M&L for secure/hanging of electrical XLPE/PVC cable/wires of any size on walls/ceiling with clamps, hooks, nuts , bolts and other accessories for electrical hyigen complete all as specified and directed.
Supply and fixing in repairs highly efficient high power multi LED flood fitting/Highbay fitting driver of 50 watt to 200 watts including fixing arrangement on wall etc complete including taking down and refixing of existing serviceable flood light fittings complete all as specified and directed by Engineer in Charge. Note:- To be fixed at min height of 12 m building / store house
Deduct Credit for Demolished/ Dismantled material Rs. (-) 80,740.00 (Minus) as listed in Schedule of Credit. Note 1:- Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'. Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
TENDERDOCUMENTS_8473.pdf
Tender Documents • 1.46 MB
BOQ_837688.xls
BOQ • 1.20 MB
Download all tender documents and submit your bid