| 1 | L1₹44.4 LAccepted-AOC 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹45.7 L+₹1.1 L (2.40%)Rejected-Finance SAPTARAG APARTMENT RAGHUNATHPUR RAA 35 V I P ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹45.8 L+₹1.2 L (2.64%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.2 L+₹1.6 L (3.53%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹46.4 L+₹1.8 L (3.95%)Rejected-Finance 22A ASWINI DUTTA ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | EAST COAST STANDARD PRODUCTS L5 | M A ENTERPRISES L4 | M/s Santosh Industrial Corporation L8 | MS AP CONSTRUTION AND CO L3 | SINHA ENTERPRISE L1 | SK CONSTRUCTION SYNDICATE & ENGG CO L7 | M/S SRINIVASA CONSTRUCTION L9 | B & R CONSTRUCTION L2 | DEYS ENTERPRISE L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | (B/R PORTION)
Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed. | 12 | Cum | 235 ₹2,820 | 235 ₹2,820 | 250 ₹3,000 | 220 ₹2,640 | 200 ₹2,400 Lowest | 240 ₹2,880 | 255 ₹3,060 | 212 ₹2,544 | 235 ₹2,820 |
| 2.00 | Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. | 3 | Cum | 110 ₹330 | 105 ₹315 | 130 ₹390 | 110 ₹330 | 100 ₹300 Lowest | 115 ₹345 | 130 ₹390 | 106 ₹318 | 110 ₹330 |
| 3.00 | Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed. | 9 | Cum | 160 ₹1,440 Lowest | 160 ₹1,440 Lowest | 200 ₹1,800 | 160 ₹1,440 Lowest | 160 ₹1,440 Lowest | 172 ₹1,548 | 200 ₹1,800 | 160 ₹1,440 Lowest | 172 ₹1,548 |
| 4.00 | Demolition of reinforced cement concrete of any description for Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended complete all as specified and directed. | 1.5 | Cum | 720 ₹1,080 | 720 ₹1,080 | 600 ₹900 Lowest | 720 ₹1,080 | 700 ₹1,050 | 730 ₹1,095 | 600 ₹900 Lowest | 720 ₹1,080 | 720 ₹1,080 |
| 5.00 | M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring benching to drain, coping, hold fast etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and as directed. | 2 | Cum | 8,200 ₹16,400 | 8,010 ₹16,020 | 8,900 ₹17,800 | 8,010 ₹16,020 | 8,000 ₹16,000 Lowest | 8,450 ₹16,900 | 8,915 ₹17,830 | 8,075 ₹16,150 | 9,000 ₹18,000 |
| 6.00 | M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. | 3 | Cum | 5,052 ₹15,156 | 5,050 ₹15,150 | 5,138 ₹15,414 | 5,050 ₹15,150 | 5,000 ₹15,000 Lowest | 5,200 ₹15,600 | 5,145 ₹15,435 | 5,050 ₹15,150 | 5,060 ₹15,180 |
| 7.00 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. | 12 | Cum | 8,625 ₹1,03,500 | 8,560 ₹1,02,720 | 8,620 ₹1,03,440 | 8,575 ₹1,02,900 | 8,500 ₹1,02,000 Lowest | 8,585 ₹1,03,020 | 8,625 ₹1,03,500 | 8,560 ₹1,02,720 | 8,585 ₹1,03,020 |
| 8.00 | M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed. | 25 | Sqm | 970 ₹24,250 | 945 ₹23,625 | 950 ₹23,750 | 930 ₹23,250 | 900 ₹22,500 Lowest | 970 ₹24,250 | 950 ₹23,750 | 920 ₹23,000 | 970 ₹24,250 |
| 9.00 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed. | 100 | Sqm | 260 ₹26,000 Lowest | 262 ₹26,200 | 275 ₹27,500 | 260 ₹26,000 Lowest | 260 ₹26,000 Lowest | 275 ₹27,500 | 280 ₹28,000 | 260 ₹26,000 Lowest | 260 ₹26,000 Lowest |
| 10.00 | S &F framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barried iron doors ladders framed balusters, walk ways, railing framedwork of water tanks and similar work conforming to Fe.290 Gde E-165 complete all as specified and directed. | 325 | Kg | 166 ₹53,950 | 163 ₹52,975 | 172 ₹55,900 | 161 ₹52,325 | 160 ₹52,000 Lowest | 172 ₹55,900 | 175 ₹56,875 | 162 ₹52,650 | 172 ₹55,900 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
28 Aug 2025, 12:00 pmClosed
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
PROVN OF RCC STAIR CASE, DEFICIENT LIGHTS, SPLIT AC OF ASTC, SPLIT AC AT ANTE ROOM, PROVN OF STAIR CASE BUILDING NO O-7/9 AND ADDN/ ALTN TO LIVING ACCN AT RAMPART 04 INSIDE VIJAY DURG UNDER GE (FW) KOLKATA
2025_MES_725127_1
8421/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹82,000
29 Sept 2025
8 Aug 2025
29 Aug 2025
8 Aug 2025
28 Aug 2025
21 Aug 2025
Amount
(B/R PORTION) Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed.
Demolition of reinforced cement concrete of any description for Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring benching to drain, coping, hold fast etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and as directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed.
S &F framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barried iron doors ladders framed balusters, walk ways, railing framedwork of water tanks and similar work conforming to Fe.290 Gde E-165 complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed.
M & L for Endura tiles of size 300 x 300x 10 mm thick, suitable for hi-traf external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
S&F Fe-410-W(Gde?E-250) B quality Stairs (framed) including stringers, threades, landing, balusters, hand rails etc. including cleats, brackets, etc. complete including using former iron props and steel plates to existing RCC over head members like beams, slabs etc so as to ensure safety of existing structure and floor during repairing works complete all as specified and directed.
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S & F pre-painted galvatume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S & F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter, Sun shed etc fixed with self tapping screws as specified.
S&F in repair 35mm precast cement concrete type B0 1:2:4 using (12.5mm graded stone aggregate louvers and jallies including all mouldings set in CM 1:4 complete all as specified and directed.
S&F mild steel Framed work as in doors or sliding gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410-W(Gde-E-250) quality-A all as specified and directed
S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available size fastening and fixing complete Fe-410-W(Gde-E-250) quality-A complete all as specified and directed.
M & L applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer of mortar as in backing coat of stone on fair face of brick wall or concrete surface in cement mortar 1:4 complete all as specified and directed.
M & L 18 to 20 mm thick machine cut one side polished natural hard stone (Granite)any type in step, jambs, pillars, window cills, cooking plate from and similar places etc like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F 18-19 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame for wardrobe/shelf complete all as specified and directed.
M&L decorative laminate type -1, 0.9 mm thickness of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's as per specification and drawing complete all as specified and directed.
S&F Stainless steel powder coated tray of various size for drawers to keep kitchen utensil with smoothly sliding arrangement complete all as specified and directed.
S&F in repairs aluminium 'E' channel for sliding drawer shutter of cub board in two way 300 mm long complete all as specified and directed.
S&F 100 mm double action spring hinges (Hydraulic hinges) brass with phosphors bronze wire spring bright polished all as specified
S&F 100 mm Extruded brass handles, fabricated type polished all as specified
S&F Stainless Steel Sink l.0mm thick Overall size 915mm x 460mm and Two Bowl size 410 mm x 355 mm x 165 mm for Kitchen or Laboratory with Plugs, Washers, Brass chromium plated Waste Fitting 32mm dia, PVC waste pipe, a Pair of Cast Iron Brackets duly Painted including Cutting and Pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including Taking down/out unserviceable Sink and connected Items, complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
M&L non skid ceramic colour tiles of area of each tile exc .18 Sqm but n exc exc .38 Sqm and 8-10 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 15 mm thick screed bed cement mortar 1:6 complete all as specified and directed.
M & L glazed ceramic colour tiles size 450 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement including 10 mm thick plastering in cement mortar 1:4 complete all as specified and directed. to match complete all as specified and directed.
S&F in repair 15mm bore chromium plated Sink cock with flange, fancy type complete all as specified and directed.
S&F repair 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed
S&F in repair 100mm CI bends any radius complete all as specified and directed
S&F 100 mm bore Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
M&L for 10 mm thick rendering on fair faces of concrete surfaces in CM 1:3 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed.
Use and waste of formwork to sides and soffits of suspended slabs, floor slab, landing and similar work n. exc. 200 mm thick rough finished surfaces of concrete complete all as specified and directed.
Use and waste form work to sides of concrete foundation, footing, bases of columns, plinth beam, side and soffits of plinth beam and similar works in vertical or to batter of fair finished surfaces complete all as specified and directed.
Use and waste form work to sides of columns, pillars etc. of fair finished surfaces complete all as specified and directed.
M & L RCC Nominal Mix Type B1 1:2:4 using 20 mm graded stone aggregate as in column footing including raft footings, foundation, plinth beam, bases of columns etc. complete all as specified and directed.
M & L RCC Nominal Mix Type B1 1:2:4 using 20 mm graded stone aggregate as in columns, pillars etc complete all as specified and directed.
M & L RCC Nominal Mix Type B1 1:2:4 using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L RCC Nominal Mix Type B1 1:2:4 (20 mm graded aggregate) using 20 mm graded stone aggregate as in Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; complete all as specified and directed.
S & F mild steel deformed bar 8 to 10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F mild steel TMT bar 5 dia and over upto and including 10 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
Supplying Integral water proofing compound.
M&L for preparation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint (Apex Ultima or equivalent) with approved colour and pattern over a coat of primer as on walls of bldgs of any height including necessary scaffolding and safety measures and procedure complete all as specified and directed.
S&F 0.8-0.9 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required all as specified and directed.
Taking out compete existing roof treatment from roof surface & roughening of old concrete floor surfaces including cleaning the roof surfaces by brushing sweeping etc and removing rubbish material complete all as specified and directed.
Material and labour for providing cement concrete (1:2:4) type BO using 12.5mm graded crushed stone aggregate as over roof for making good depression/undulation to make the existing as filling in depression of roof slab and roof kerb complete all as specified and directed.
M & L for rendering 15mm thick on fair faces of concrete surfaces in cement mortar 1: 4 under APP membrane finish rendering surfaces even and smooth with out using extra cement mixed with WPC @2% by weight of cement or as per manufacturer instruction. Complete all as specified and directed (Note:- WPC shall be measured and paid separately)
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 complete all as specified and directed.
M & L for brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and directed.
M & L for for water proofing treatment on existing cleaned RCC roof with the following specification and manufacturing's instruction complete all as specified and as directed:- (a) Preparing and cleaning of fully dry surfaces as per IS3067-1966 (b) Applying bitumen primer conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm (c) Applying a layer of APP based polymeric membrane 3.0mm thick (minimum) weight 3.0Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.
E/M Portion Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and directed.
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting modular type switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage) (a) One light point or one fan point controlled by one switch
All as per item No 58 but one 3/5 pin socket outlet, 5 Amp independent
All as per item No 58 but one 3/5 pin socket outlet, 5 Amp on the same board with other switches
All as per item 58 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuity wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 58 above but using 4.0 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke (FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 4.0 sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed.
S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Bell push 6A, 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 2 module complete all as specified and directed.
S & F Modular type White cover plate with frame 3 module complete all as specified and directed.
S & F Modular type White cover plate with frame 4 module complete all as specified and directed.
S & F Modular type White cover plate with frame 6 module complete all as specified and directed.
S & F Modular type White cover plate with frame 8 module complete all as specified and directed.
S & F Modular type White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 1/2 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S & F Ceiling rose, 3 terminal PVC insulated body complete all as specified and directed.
Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and directed.
S & F in repair LED Indoor Commercial LED Luminaires light fitting 36 W (fixture size;(LxWxH) in(1271 x 163 x46) saBer led merges classic styling with cutting edge technology to provide quality illumination and superior optical control. as in repair, minimum colour temperature 6500K, with suitable driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. Make: Hevells cat part saBerlP36Wled840sPmmaWH or equivalent make specified in tender.
Supply & fixing wall mounted fans 230 volts single phase oscillating 400 mm sweep with white/Black Colour with following technical specification Box Dimension 48x24.5x47.5cm wattage 35W ,Air Delivery (CMM)76 Blade Length 40CM,Speed 1500RPM, Item Weight 4.2Kg Voltage 165-285V, Blade Material ABS PLastic including all Fixing accessories for fixing at Wall complete all as specified and directed.
S & F BLDC ceiling fans of 1200mm sweep with class F copper insulation for winding ,canopy, fan blades and accessories, BEE 5 Star Rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
S & F exhaust fan 300 mm sweep, AC single Phase 230 / 240 volts, metal body with louver shutters and connecting up with and including twin core twisted flexible copper conductor cable of suitable dia ,nut bolt and accessories, and winding, pending etc connecting up including taking down with re -fixing provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.0mm GI wire (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 5 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion.
Supply and Fixing in replacement of following GI pipe light grade (ISI Marked) for cable protection along wall/pole/floor/road crossing etc complete including sealing of pipe ends with approved sealing compound including taking up old UNSV GI pipe of 50mm dia complete all as specified and directed.
S&F down rod of 15mm dia of galvanized steel medium grade duly painted with one coat of primer and two coat of synthetic enamel paint of length as per suitable at site requirement complete all as specified and as directed
Supply, Laying and testing for replacement of 50 Sqmm, 3.5 Core XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :- Note :- Necessary earth work to be measured and paid separately.
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation.
M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-capping of suitable size, surface type all as directed.
All as per Srl. Item No. 92 above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor.
All as per Srl. Item No. 92 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor.
Taking down of Old MCB DB any type any size including MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
S & F TP&N Vertical Loadline Dbs are fitted with Bus Bars, Neutral Links, Blanking Plates 4 way double door DB LL 4W DD VERT W/O MCCB complete all as specified and as directed
S&F in repairs of MCCB 4 Pole, 415 V, 100 Amps with adjustable type, breaking capacity 16 KA, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed
S & F Double door sheet metal enclosure for DBs(Premium range) for mounting of MCB for 240 Volts 8 Way with 100 Amps rated copper bus bar, single pole and Neutral complete all as specified and directed.
Supply and fixing MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Supply and fixing MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S & F exhaust fan 450 mm sweep, AC single Phase 230 / 240 volts, metal body with louver shutters and connecting up with and including twin core twisted flexible copper conductor cable of suitable dia ,nut bolt and accessories, and winding, pending etc connecting up including taking down with re -fixing provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :- (a) 25 Sqmm, 3.5 Core
Supply, Laying and testing for replacement of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall with saddles/Flat iron clamps as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :- (a) 50 Sqmm, 3.5 Core
Supply and install split units indoor/outdoor complete with cordless remote control with minimum 5 star rating inverter type of capacity 2.0TR , copper condenser coil including 4 sqmm 4 core flex cable connection from indoor to outdoor unit as per site requirement including necessary masonry work for making good distributed surface and match with the existing colour complete all as specified. Note :- Copper pipe , insulation and connecting cable will be measured and paid separately under respective item
M&L for replacement of sub main wiring with 2 run of 6 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/capping (25mm dia) including size 6 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 6 Sqmm pvc wire, one run of 10 Sqmm pvc wire and one run of pvc casing capping/ PVC conduit will be measured as one unit)
Supply and fixing copper cable 6.0 sqmm 4 core duly connected and properly clamped from indoor unit to Outdoor unit complete all as specified and directed
Supply and fix in repairs suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity all as specified and directed.
Supply and fix in repairs discharge copper pipe line heavy duty 1/4" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity all as specified and directed.
Supply and fix in repairs PVC pipe nylon imbraided 1of size 5/8" for condenser water drain fitted with clamps/ concealed in wall all as specified and directed.
S&F Nitrile Rubber insulation for copper tubing of size 1/2'' dia duly wrapped complete all as specified and directed.
S&F Nitrile Rubber insulation for copper tubing of size 1/4'' dia duly wrapped complete all as specified and directed.
S & F in repair AC short circuit protection motor starter 20 Amps capacity AC 230 Volt complete all as specified and directed.
S & F PVC Cable trays with cover of size 75mm X 75mm on walls / ceilings as per site requirement for proper fixing of Copper pipe with insulation alongwith fittings and fixtures arrangement complete all as specified and directed.
Supply and fixing angle iron brackets wall mounted / Floor mounted as per site made of steel including two coats of powder coated finish and foundation bolts and nuts firing complete and making good the disturbed surface complete all as specified and directed.
Supply and fixing copper cable 2.5 sqmm 4 core duly connected and properly clamped from indoor unit to Outdoor unit complete all as specified and directed.
S & F Modular Fan step regulator, 120W- 2 module complete all as specified and directed
S & F Modular Blank plate, 1 module complete all as specified and directed
S & F in repair lamp pendant / batten holder, complete all as specified and directed
Supply and fixing LED lights fitting 1x 20W, 220V,warm light AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F in repair LED tube light fitting 10 watt, warm light mounted on wall / ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door 415V Triple pole & Neutral 4 way with common bus bar. complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door 240V single pole & Neutral 4 way with common bus bar complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 amps rated bus bar complete all as specified and directed.
S & F MCB 'C' curve single pole neutral , 32 Amps with breaking capacity 10kA, complete all as specified and directed. Make : Cat No. 408617 of Legrand or equivalent make specified in tender.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
B & R CONSTRUCTION (BID ID -3404789)
MS AP CONSTRUTION AND CO (BID ID -3404411)
M A ENTERPRISES (BID ID -3403307)
EAST COAST STANDARD PRODUCTS (BID ID -3402004)
DEYS ENTERPRISE (BID ID -3405080)
SK CONSTRUCTION SYNDICATE & ENGG CO (BID ID -3404942)
M/s Santosh Industrial Corporation (BID ID -3403456)
M/S SRINIVASA CONSTRUCTION (BID ID -3406139)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .