Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-Finance RATNA P S RATNA MALDA | MALDA | MALDA | WEST BENGAL | ₹40.6 L | L1 | Accepted-Finance Lowest bid offered. |
| 2 | L2₹41.1 LRejected-Finance MALDA | MALDA | ₹41.1 L | L2 | Rejected-Finance Higher than L1 |
| 3 | L3₹41.2 LRejected-Finance DOMJUR NEAR SITALA MANDIR GHOSHPARA FOKOR DOKAN DOMJUR HOWRAH 711405 | HOWRAH | WEST BENGAL | 711405 | ₹41.2 L | L3 | Rejected-Finance Higher than L1 |
Tender Value
₹40.6 L
EMD Value
₹81,195
Closing Date
15 Jan 2026, 5:00 pmClosed
THE EXECUTIVE ENGINEER MALDA DIVISION, PHED
DOULATPUR PHE COMPLEX, MALIHA MALDA-732102.
Shifting of PHE pipeline for Ratua to Bhaluka Road from 6.40 km to 11.20 km, widening and strengthening work under Malda Highway Division in the district of Malda during the year 2023-24. (RIDF-XXX).
2025_PHED_977209_1
WBPHED/EE/MD/NIeT_39 of 2025-2026
Open Tender
CIVIL WORKS
60 days
DOULATPUR PHE COMPLEX, MALIHA MALDA-732102
Please refer Tender documents.
5 documents required · 5 mandatory
₹81,195
Yes
23 Jan 2026
20 Dec 2025
17 Jan 2026
20 Dec 2025
15 Jan 2026
20 Dec 2025
Supply and delivery of ISI Marked Centrifugally Cast (Spun) Ductile Iron Pressure Pipes for water with Socket & Spigot ends conforming to IS:8329/2000 (Latest amendment) in standard length of 5.5M suitable for push on joint (rubber gasket joining) with cement mortar lining inside the pipes and outside zinc coating with finished layer of Bituminous coating / Synthetic resin (Blue / Red Epoxy) compatible with Zinc coating 9Clss K-9 & Class K-7) along with supply of EPDM quality of Rubber Gasket as per IS:5382/1995, for each joints admissible for the order quantity and 5% extra and supply of polyethylene sleeves along with D.I. pipes to be supplied. The polyethylene sleeves are to be tested by CIPET and this certificate should be contain the quality.
a) 150 mm dia D.I. , K-9
Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder, road sub-grade and its flank,but excluding moorum and laterite and stone etc.without damaging the exisiting telephone/electric cable etc.(in case of damaged if any type of cable line during excecution , necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. N.B: i) Any deviation from required clear cover of 1.10mtr., due to site adverse condition, prior permission is to be obtained from the EIC in exceptional situation and payment will be made on prorate basis over the rate of entire item ii) No payment will be made without hydraulic test of the pipe line either part or full iii) The pipes, specials and valves , rubber gasket will be supplied deptt. free of cost.
a) 150 mm dia D.I.
Cutting DI pipe (all class & type) to required length with cutting device etc. and grinding the cutting portion with file as per direction and satisfaction of EIC.
b) 150 mm.dia.to 200 mm.dia pipe
Chamfering the spigot end of all type/class of DI pipe for proper using of push joint by means of grinder set at site for proper joint etc. all complete as per direction of EIC.
b) 150 mm.dia.
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source).
A) For CI/DI pipe
i) 150 mm.dia.
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).
A) For CI/DI pipe
i) 150 mm.dia.
Making rubber gasket joint to CI/DI pipes maintaining proper alignment level etc. by mechanical arrangement with or without using mobile cranes where necessary and with help of all other equipment stools and tackles etc. as required providing lubricants of approved quality and direction of EIC. (rubber gasket will be supplied deptt. free of cost)
a) 150 mm dia D.I. , K-9
Supply and delivery of different dia. D I specials including loading unloading and carriage inclusive of taxes and all charges whatsoever.
For 150 mm dia.
a) FLANGE SPIGOT 150
b) FLANGE SOCKET 150
c) Mechanical Collar 150
d) All Flange Tee 150X150X150
e) Double Flanged Bend 150X 900
f) Double Flanged Bend 150X 450
g) Double Flanged Bend 150X 22.50
h) Double Flanged Bend 150X 11.250
i) Double Flanged Short Piece 150X1.0 M
Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R-12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2. N.B: The above item should be procured from the reputed manufactures as per deptt. approved vender list.
a) 150 mm dia.
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in roof slab including supply of 150mmx150mm C.I. surface box embedded into RCC cover slab all complete including cost of labour & materials. (a) with 100mm thick RCC cover slab for village road where light traffic run.
a) 80 mm to 150 mm dia pipe
Making flange joint to DI/CI pipes, specials and valves where necessary with supply of required rubber insertion and nut bolts, washers etc. of approved quality and type all complete as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW make).
a) 150 mm dia.
Carriage of different type of departmental pipes from Divisional/Sub-divisional store to the work site by truck including loading, unloading, stacking etc. including cost of fuel, lubricant and also cost of driver, helper etc. and all other taxes and charges as applicable as per direction of EIC: Above 40 Km upto 50 Km
Earthwork in excavation in foundation trenches or drain in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading & stacking the spoil within a lead of 75m as directed. The item includes necessary trimming the sides of trenches. Levelling, dressing and ramming the bottom, bailing out of water as required complete. (a) Depth of excavation not exceeding 1500 mm.
Filling in foundation or plinth by fine sand in layers not exceeding 150mm as directed and consolidating same by thorough saturation with water ramming complete. Including the cost of supply of sand.( Payment to be made on measurment of finished quantity ).
Hire charges for shuttring with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beam, columns, lintles curved or straight including fitting, fixing and striking out after completion of works.(In all floors). 25mm to 30mm thick wooden shuttering as per decision and direction of Engineer-In-Charge.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel. II. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL.
Ordinary cement concrete ( mix 1:1.5:3 ) with graded stone chips ( nominal 20 mm size) excluding shuttering and reinforcement. If any, : Pakur Variety. (Rate Analysis)
Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solvent cement (as per IS:14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C.
N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line. ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list. iii) No part payment at any stage on account of supply of materials shall be entertained. iv) Payment will be made on actual consumption of materials. v) UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi) Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item. viii) All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill. ix) No payment will be made without hydraulic test of the pipe line either part or full
(A) Pressure Rating : Class - III (ii) Laying of pipe line including cost of pipe & fittings /specials but excluding cost of valves.
a) 90 mm(OD)
b) 125 mm(OD)
c) 140 mm(OD)
d) 160 mm(OD)
e) 200 mm(OD)
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source).
a) 90 mm(OD)
b) 125 mm(OD)
c) 140 mm(OD)
d) 160 mm(OD)
e) 200 mm(OD)
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).
a) 90 mm(OD)
b) 125 mm(OD)
c) 140 mm(OD)
d) 160 mm(OD)
e) 200 mm(OD)
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by JE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies.
Add Includng GST @18%
Add Includng CESS @1%
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 5.40 MB
Tendernotice_2.pdf
PDF • 0.76 MB
Tendernotice_3.pdf
PDF • 1.08 MB
Tendernotice_4.pdf
PDF • 0.51 MB
BOQ_2381914.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid