Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAdmitted-Finance | ₹32.7 L | L1 | Admitted-Finance |
| 2 | L2₹32.8 LAdmitted-Finance | ₹32.8 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not meeting Eligibility Criteria |
| Sl No | Description | Qty | Unit | Comfort systems L1 | OM REFRIGERATION AND ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00Schedule-A & B | |||||
| 2.00 | (Schedue A)-Manpower: Operation & Maintenance of Central Air-Conditioning Heating & Ventilation plant. as per Annexure-B (List of equipment installed) | 24 | Months | 70,000 ₹16.8 L | 94,100 ₹22.6 L |
| 3.00 | (Schedule B)-Consumables: Consumable material such as copper pipe /tube , Gasket, HRC Fuses up to 16 Amp, all bearing greases/oil/ refrigerant, Belts, Rubber Bushes, Gland Packing, Seal, Sight Glass, Indication Lamps, PVC wire, Tapes, Screw, Nuts, Bolts, Cotton Waste, Duster, Emery Paper, Soap, Salt for regeneration ,CTC Liquid, Acid for cleaning, temperature indicator, rubber pads, etc. Transportation (To & Fro) charges for the material/equipment for outside repair. Compressor oil , etc. | 24 | Months | 10,000 ₹2.4 L | 10,500 ₹2.5 L |
| 4.00Sub Total of Schedule-A &B | |||||
| 5.00Schedule-C (AHU) | |||||
| 6.00 | Rewinding of motor above 10HP ( It includes To & Fro handling of motors from site to Workshop, no separate labour charges & transportation would be paid) Make:CG/ABB , Model: HX 132MC4 | 2 | No | 6,000 ₹12,000 | 750 ₹1,500 |
| 7.00 | Rewinding of motor up to 7.5 HP ( It includes To & Fro handling of motors from site to Workshop, no separate labour charges & transportation would be paid) Make:CG/ABB , Model: HX 132SMB4 | 2 | No | 5,000 ₹10,000 | 750 ₹1,500 |
| 8.00 | Blower shaft Make:AIR FLOW , Model: AF6, | 2 | No | 2,000 ₹4,000 | 250 ₹500 |
| 9.00 | Terminal plate for motor Make:STD. MAKE , Model: 10 HP/7.5 HP | 8 | No | 1,000 ₹8,000 | 150 ₹1,200 |
| 10.00 | Motor pulley Make:STD. MAKE & Model | 2 | No | 1,000 ₹2,000 | 150 ₹300 |
Tender Value
₹39.4 L
EMD Value
₹50,000
Closing Date
27 Mar 2026, 12:00 pmClosed
Kuldip Singh
DGM Tech and Proj NFL, CO, Noida
RATE CONTRACT FOR OPERATION and MAINTENANCE OF COMPLETE HVAC SYSTEM INSTALLED At NFL Corporate Office Noida
2026_NFL_269756_1
NFL/CO/Proj/HVAC/2026-28
Open Tender
Miscellaneous Works
730 days
NFL, Corporate Office, Noida
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹50,000
20 Apr 2026
6 Mar 2026
30 Mar 2026
6 Mar 2026
27 Mar 2026
6 Mar 2026
6 Mar 2026 - 20 Mar 2026
Schedule-A & B
(Schedue A)-Manpower: Operation & Maintenance of Central Air-Conditioning Heating & Ventilation plant. as per Annexure-B (List of equipment installed)
(Schedule B)-Consumables: Consumable material such as copper pipe /tube , Gasket, HRC Fuses up to 16 Amp, all bearing greases/oil/ refrigerant, Belts, Rubber Bushes, Gland Packing, Seal, Sight Glass, Indication Lamps, PVC wire, Tapes, Screw, Nuts, Bolts, Cotton Waste, Duster, Emery Paper, Soap, Salt for regeneration ,CTC Liquid, Acid for cleaning, temperature indicator, rubber pads, etc. Transportation (To & Fro) charges for the material/equipment for outside repair. Compressor oil , etc.
Sub Total of Schedule-A &B
Schedule-C (AHU)
Rewinding of motor above 10HP ( It includes To & Fro handling of motors from site to Workshop, no separate labour charges & transportation would be paid) Make:CG/ABB , Model: HX 132MC4
Rewinding of motor up to 7.5 HP ( It includes To & Fro handling of motors from site to Workshop, no separate labour charges & transportation would be paid) Make:CG/ABB , Model: HX 132SMB4
Blower shaft Make:AIR FLOW , Model: AF6,
Terminal plate for motor Make:STD. MAKE , Model: 10 HP/7.5 HP
Motor pulley Make:STD. MAKE & Model
Blower pulley Make:STD. MAKE & Model
Bush for blower pulley Make:STD. MAKE& Model
Syphon with cock for chiller line Make:STD MAKE& Model
Schedule-C (Compressors-Electrical & Misc. Fittings)
Thermal over load relay Make:EE/L&T , Model: 6.7-10 AMP
CT operated relay Make:EE/L&T , Model: TYPE -ECT-7, 415V,74-111 AMP
Timer Make:EE/L&T , Model: 0.1-1.0 MIN
Single phase preventer Make:MINILEC , Model: D2
HP switch(differential pr. Switch) Make:INDFOS , Model: MP-5
LP switch(differential pr. Switch) Make:INDFOS , Model: MP-1
OP switch(differential pr. Switch) Make:INDFOS , Model: MP-55
Expansion valve Make:SPORLAN , Model: MVE-42-CP-100
Power Contactor 3 Pole( Coil voltage 230V) Make:EE/GEC ALSTHOM , Model: EC-6,415V,115A
Solenoid valve assembly with coil & filter Make:SPORLAN , Model: PILOT OPERATED 3WAY FOR QUARTER LINE
Rewinding of motor 100 HP (it includes To & Fro handling of motors from site to Workshop, no separate labour charges & transportation would be paid) Make:CG/ABB
Terminal plate for motor Make:STD. MAKE , Model: 100 HP
Motor bearing for 100 HP motor Make:SKF/ FAG , Model: NU 16ECJ(336W) 6316(03-357W)
Volt meter Make:AE/RISHABH , Model: 0-500 VOLT
MCCB, rating 250amp,415V,50Hz, instantaneous 750-2000A Make:L&T , Model: DTH250
Pressure Gauge(Oil & Discharge) Make:Fiebig , Model: 4" Dia, 0-300/psi
Pressure Gauge(Suction) Make:Fiebig , Model: 4" Dia, 0-150/psi, 0-30Hg
Schedule-C (Pumps)
Timer Make:EE/L&T , Model: 0.1-1.0 MIN
Thermal over load relay Make:EE/L&T , Model: 6.7-10 AMP
Single phase preventer Make:Minilec , Model: VSP D1
MCB TP 415V volt Make:Havell's/L&T/Schindier , Model: 32 AMP
Connector/terminal block Make:Elemex/ connectwell , Model: 2.5 SQ MM / 6.0 SQ MM/10 SQMM
Mechanical seal for domestic pumps Make:Std make/ Gems (Super seal) , Model: 19 MM
Syphon with cock Make:Std make & Model
Shaft sleeve / bush for Kirloskar make 10 HP pump KDS 1030 ++ Make:Kirloskar make
Sub Total of Schedule-C
Schedule-D (Supply and Replacement of pipes & fittings)
MS Pipes (Class-C) Make:Jindal/Sail/Tata , Size: 2”
MS Pipes (Class-C) Make:Jindal/Sail/Tata , Size: 2 1/2”
MS Pipes (Class-C) Make:Jindal/Sail/Tata , Size: 4”
MS Pipes (Class-C) Make:Jindal/Sail/Tata , Size: 5”
MS Pipes (Class-C) Make:Jindal/Sail/Tata , Size: 6”
MS Pipes (6.35mm wall thickness) Make:Jindal/Sail/Tata , Size: 10”
MS Pipes (6.35mm wall thickness) Make:Jindal/Sail/Tata , Size: 12”
Replacement of valves (nuts & bolts & gaskets are in the scope of contractor, valve to be provided by the NFL) Make:Reputed , Size: 2” to 5 “
Replacement of valves (nuts & bolts & gaskets are in the scope of contractor, valve to be provided by the NFL) Make:Reputed , Size: 6” to 8 “
Replacement of valves (nuts & bolts & gaskets are in the scope of contractor, valve to be provided by the NFL) Make:Reputed , Size: 10” to 12“
Sub Total of Schedule-D
Schedule-E (Painting Job: - HVAC PLANT & Electrical panel, One time job)
Painting of HVAC Plant Chiller Units along with foundation according to colour code (complete i.e. compressors, condensers & chiller , motor)
Painting of the HVAC Plant according to color code. Pump with Motor Up to 12.5 HP , 3 phase, 415 V, 16 No pumps (7 No. condenser pumps, 5 No. Chiller pumps, 2 No. domestic water, 2No. sump pump
MS Pipe line related to the above Pumps & its associated Valve etc.=4000Sq.feet
Electrical Panels=2000Sq. Ft
Sub Total of Schedule-E
Schedule-F (Insulation Job: - HVAC PLANT)
To provide high density Rock / glass wool & thermocoal insulation & cladding on cold water/ chiller line & hot water line 65 mm & above (including its associated accessories ) -2.5" PIPE SIZE
To provide high density Rock / glass wool & thermocoal insulation & cladding on cold water/ chiller line & hot water line 65 mm & above (including its associated accessories ) -4" PIPE SIZE
To provide high density Rock / glass wool & thermocoal insulation & cladding on cold water/ chiller line & hot water line 65 mm & above (including its associated accessories ) -6" PIPE SIZE
To provide high density Rock / glass wool & thermocoal insulation & cladding on cold water/ chiller line & hot water line 65 mm & above (including its associated accessories ) -(10"-12")" PIPE SIZE
Sub Total of Schedule-F
Schedule-G (Critical Spares)
Spares for Hi-wall type indoor units (Samsung VRV-22HP)-Supply and installation of Sensors (Inlet & Outlet)
Spares for Hi-wall type indoor units (Samsung VRV-22HP)-Supply and installation of Motor
Spares for Hi-wall type indoor units (Samsung VRV-22HP)-Supply and installation of PCB
Spares for Hi-wall type indoor units (Samsung VRV-22HP)-Supply and installation of Expansion Valve
Spares for Hi-wall type indoor units (Samsung VRV-22HP)-Supply and installation of Float Switch
Spares for Casette type indoor units (Samsung VRV-22HP)-Supply and installation of Sensors (Inlet & Outlet)
Spares for Casette type indoor units (Samsung VRV-22HP)-Supply and installation of Expansion Valve
Spares for Casette type indoor units (Samsung VRV-22HP)-Supply and installation of Motor
Spares for Casette type indoor units (Samsung VRV-22HP)-Supply and installation of PCB
Spares for Casette type indoor units (Samsung VRV-22HP)-Supply and installation of Float Switch
VRV Unit 22HP drain water pump with assembly
Removal of exisiting and applying new Epoxy coating on whole new outdoor units-Samsung VRV Unit
Bluestar Package Unit (Model No: DPA2163R3-I, Sl No: DPA2163R3-IERF00011)-36TR: LP Switch for Bluestar Package Unit
Bluestar Package Unit (Model No: DPA2163R3-I, Sl No: DPA2163R3-IERF00011)-36TR: HP Switch for Bluestar Package Unit
Bluestar Package Unit (Model No: DPA2163R3-I, Sl No: DPA2163R3-IERF00011)-36TR: Rewinding of Outdoor Motor for Bluestar Package Unit
Bluestar Package Unit (Model No: DPA2163R3-I, Sl No: DPA2163R3-IERF00011)-36TR: Rewinding of Indoor Motor for Bluestar Package Unit
Bluestar Package Unit (Model No: DPA2163R3-I, Sl No: DPA2163R3-IERF00011)-36TR: Temperature Sensor for Bluestar Package Unit
Bluestar Package Unit (Model No: DPA2163R3-I, Sl No: DPA2163R3-IERF00011)-36TR: Outdoor Fan for Bluestar Package Unit
Bluestar Package Unit (Model No: DPA2163R3-I, Sl No: DPA2163R3-IERF00011)-36TR: Crankcase Heater for Bluestar Package Unit
Supply and filling of Refrigrant Gas (R-410)_Du-pont Make
Supply and filling of Refrigrant Gas (R-134a)_Du-Pont Make
V belt for AHU's (A-50)
V belt for AHU's (A-48)
V belt for AHU's (A-49)
Syphon with Valve (3/8") of reputed make
NRV, 125 mm of reputed make
Butterfly valve,125mm of reputed make
Belt for cooling Tower B-80 to B-120
Transducer, Sensors LP/HP for Blue Star Chiller -120TR
Transducer, Sensors LP/HP for YORK Chiller-120TR
Water Temperature Sensors for Blue Star Chiller-120 TR
Water Flow Switch of reputed make
Compressor Oil for Chillers (Bluestar & York)
Oil Heater for Blue star Chiller-120TR
Oil Sensor for Bluestar Chiller-120TR
Electronic/Electric Expansion Valve for Chillers
Water Pressure Gauge (0-7Kg/Cm2g), 3/8" of reputed make
Bearing (6307, 6308 & 6309) of reputed make
Spares for CTI Certified Bell make Cooling Towers-Cast Aluminum Alloy Axial Flow Fan
Spares for CTI Certified Bell make Cooling Towers-Cooling tower motor – 12.5 Hp, 570 RPM, IE3 direct drive
Spares for CTI Certified Bell make Cooling Towers-PVC Fills
Spares for CTI Certified Bell make Cooling Towers-PVC Eliminator
Spares for CTI Certified Bell make Cooling Towers-Resin , Fiber, Catalyst Cobalt with coating powder
Sub Total of Schedule-G
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_314302.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
NIT.pdf
Tender Documents • 1.47 MB
BOQ_314302.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid