Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.3 LAccepted-Finance 00 BAIKUNTHPUR SIRSA MANPUR BAIKUNTHPUR SIRSA MANPUR GOPALGANJ 841409 GOPALGANJ BIHAR 841409 | GOPALGANJ | BIHAR | 841409 | L-1 | Accepted-Finance Admitted | |
| 2 | L-2₹9.0 L+₹1.7 L (23.8%)Accepted-Finance BLOCK S HOUSE 75 MOHAN GARDEN WEST DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | L-2 | Accepted-Finance Admitted | |
| 3 | L-3₹9.8 L+₹2.5 L (34.6%)Accepted-Finance GRAM POST SATHIYAV MUBARAKPUR DISTRICT AZAMGARH | AZAMGARH | UTTAR PRADESH | 223221 | L-3 | Accepted-Finance Admitted |
Tender Value
₹10.7 L
EMD Value
₹11,000
Closing Date
5 Aug 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle, 220 KV S/S Campus Natwa, Mirzapur
Regular/Preventive/breakdown maintenance of 220/132/33 KV Substation Natwa, Mirzapur under Electricity Transmission Division, Mirzapur.
2022_UPTCL_714354_1
14/2022-23/ETC/Mzp
Open Tender
Electrical Works
Fixed-rate
240 days
Mirzapur
As per tender specification
2 documents required · 2 mandatory
₹1,298
Executive Engineer, ETD, Mirzapur
₹11,000
28 Sept 2022
13 Jul 2022
6 Aug 2022
13 Jul 2022
5 Aug 2022
13 Jul 2022
Amount
Routine checking and maintenance work of Transformers installed at 220/132/33 KV S/S Mirzapur including checking and maintaining of oil level in conservator,OLTC gear casing, diverter switching, breather, bushing, oil leakage, silica gel colour, AC supply, noise and vibrations etc. (Required consumable materials shall be provided by department)
Routine checking and maintenance of 220 KV, 132 KV & 33 KV CTs, PT's/ CVTs & LA's including checking of oil level, oil leakage and filling of T/F oil up to required level, cleaning of dust on insulators, Tightening of connection on TB in junction box (consumable materials shall be provided by department)
Routing checking and maintenance of 132 KV & 33 KV capacitor bank unit by visual examination of bank for fouling , leakage of capacitor unit, leakage of Series reactor/NCT, oil level, silica gel colour and oil leakage, cleaning of insulators an bushings (Required consumable materials shall be provided by department)
Regular maintenance of Battery cell with reading (voltage, specific gravity, temperature etc), cleaning, tightning of battery terminal if required, make up of distilled water at required level & applying petroleum jelly on cells, tightening of leads of Battery set. Battery water, Battery Acid, petroleum jelly, cotton cloth etc. consumable materials and T&P included in cost (Except battery cell repairing)
110 V 300 AH Battery set (02 set)
Routine checking & maintenance of switchyard equipments, C&R panel, BCU’s, ACDB & DCDB panel. Cleaning of C&R panel, BCU’s , ACDB & DCDB panel from Air blower/Vaccum cleaner. for completion of works T&P shall be provided by contractor. (Required consumable materials shall be provided by department)
Servicing & maintenance of Air Conditioners in every two month (From March to Sep.). First sevicing in the month of March, second servicing in the month of June & third Servicing in the month of September mounted in control room, BCU room, Committee room and associated buildings ( 16 Nos. of Air Conditioner ) and damaged parts shall be replaced, gas filling to be done for proper running of air conditioners. Complete the job satisfactorily with all Spares, man and T&P including in cost. (All spares, cooling gas shall be provided by Contractor including in cost.)
Daily maintenance of garden, plantation of flower vases including proper cutting of grass, hedges, ornamental plant/trees, seasonal flower planting & watering etc by gardener (Mali) including outside of controol room & colony along with maintenance of trees/plants/hedges along the roads between main gate to control room/store at substation to keep them healthy. seasonal flower, Compost manure, associated material excluding in cost. Consumable materials and T&P included in cost.
Daily general cleaning and maintenance of control room to main gate, committee room, associated office, all associated door & windows glass, battery room & all associated BCU etc by brooming & mooping along with cleaning of associated Toilet, washroom and scraping of unwanted growths in between joints of CC roads etc. in associated job consumable material including in cost. For completion of work full time sweeper available at this substation.
Maintanance of mulsifire system including water tank, Air compressor pump, Jockey pump, DG Pump, Main pump, compressor pipe line/Valve from pump to transformer. General cleaning of all pumps/Valve/panel pipe lines surrounding in pump house. Running of all pumps on auto mode in pump house so as to note leakage in pipe lines, pumps, Valves, pipe line pump house to transformer. Attending leakage in pipe line, foot valves, gate valves by tightning nut & bolts by replacing gland.(gland/gaskets required shall be provided by contractor). maintanance of jockey/main/ diesel pump including changing of gland as and when required (gland /packing as required to be provided by contractor). Checking of engine oil level , fuei oil level, checking of fuel oil/oil filter, topping of distilled water in its battery, checking maintaining engine collant level , cleaning air filter.(All lubricant to be provided by contractor including in cost). Replacement of electrical contractor/overload relay/pressure gauge/pressure switch as and when required (All spare material provided by contractor including in cost). Rewinding of Air compressor motor, changing of gland of jockey pump, Main pump, DG Pump as when required for attending oil leakage including in cost.(All spare material including in cost provided by contractor).maintaining all time up to one year for job satisfactory.
Replacement of defective/damaged interrupter in 33KV CB pole by opening of jumper, pole and replaced by new one of same rating including shifting of new pole from store to site and shifting defective/damaged materials from site to store in safe place. work also includes re-jumpering and associated works.
Replacement of defective/damaged 33 KV CB pole by opening of jumper, dismantling of damaged pole and replaced by new one of same rating including shifting of new pole from store to site and shifting of defective/damage material from site to store in safe place.
Tightening of nuts bolts, cleaning of insulators and replacement of defective clamps and connector of various equipment in all 220, 132 & 33 KV bays in 220/132/33 KV switchyard. Applying of greese for lubricating in different rating of isolator in 220/132/33 KV switchyard. Complete the job satisfactorily with all man, greese and T&P (materials shall be provided by department).
First job in the month of March-April (before summer season) as per availability of shutdown
220 KV bay
132 KV bay
33 KV bay
Second job in the month of September-October (before festive season) as per availability of shut down
220 KV bay
132 KV bay
33 KV bay
Replacement of damaged Jaw/blades of 220/132/33 KV isolators & correcting of allignment of different rating isolator if required by opening of defective jaw and blade its tightening after removing connected jumpers and its proper re-jumpering including lubricating of Jaw/Blade. with all man and T&P. (Materials shall be provided by department)
220 KV side
132 KV side
33 KV side
Replacement of jumper
Panther
Zebra
Replacement/dismantling of following equipments by new one by the way of opening of nut and bolts, opening of jumpers, cable connections, earthing etc including shifting of new equipment from store to site and defective equipment site to store/designated place in the yard as per direction of supervising engineer at 220 KV sub-station Mirzapur
245 KV instrument transformer (CTs, PTs, CVTs)
145 KV instrument transformer (CTs PTs, CVTs)
145 KV post insulator
120 KV lightening arrester
36 KV 3 phase VCB
36 KV 1- phase CT
36 KV 1- phase PT
30 KV 1-phase LA
32/22/18 KV post insulator
132 KV Capacitor unit cell
33 KV Capacitor unit cell
132 KV Capacitor unit series reactor
33 KV Capacitor unit series reactor
Removing/fixing/maintenance of complete sodium/LED light fitting assembly from poles/tower/platform building etc
Upto 10 Meter
10 meter above
Replacement/repairing in junction/Marshalling box, MCB, HPSV Choke, HPSV Lamp. ignitor, condenser, power contractor, relay, Fuse grip etc.
Replacement of damaged control/power cable in original position including taking out damaged cable from cable trench, shifting to store. (cable provided by department)
Replacement of damaged Clamp/connector of 220/132/33 KV LA,s, CT,s, CVT,s, PT,s, isolators, breaker,bushing,post insulator etc by new one by the way of opening of nut and bolts, opening of jumpers, cable connections, earthing etc including shifting of new Clamp/connector from store to site and defective Clamp/connector site to store.
220 KV side
132 KV side
33 KV side
Cleaning of cable trench, sump well, cable reck and drainage of 220, 132,& 33 KV Switchyard. Collection of foregin materials, paper, plastic and general cleaning maintaining all time up to one year. All man and T&P arranged by contractor.
M/S KSHITIJ ENTERPRISES
M/S SHANTI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .