| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹49.8 L+₹15.4 L (44.5%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹50.5 L+₹16.0 L (46.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹51.2 L+₹16.7 L (48.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.3 L
EMD Value
₹98,600
Closing Date
19 Jul 2023, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
PROVN OF POWER FACTOR SYSTEM AT 153 GH POWER HOUSE AREA PROVN OF MES WATER SUPPLY CONNECTION IN JCOs LIVING JCOs MESS AND OR MESS LIVING AND PROVN OF CERTAIN MINOR WORKS UNDER GE 865 EWS LEH
2023_MES_604850_1
865/EWS(NIT-72)/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹98,600
Yes
12 Oct 2023
22 Jun 2023
26 Jul 2023
22 Jun 2023
19 Jul 2023
5 Jul 2023
Amount
Supply, installing , testing & commissioning of Automatic Power Factor Correction (APFC) panel 250 KVAR 6 step with APP all polypropylene) capacitor rated for 15% non linear load with HRC protection including 630 Amps, 35 KA, 4 Pole MCCB as incomer alongwith intelligent power factor control. Air core reactor for extra safety from inrush current (high current). Provision of top and bottom cable entry, automatic temparature, control through fans and louvers in panel. Double side earthing connection. Ref standard : IEC 61921/IS/16636 /IEC 61439 to continously sense and monitor the load conditions by the use of the external CT and ensure consistent power factor following the display information.
Supply and laying, jointing and testing cable, LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor in size 400 Sqmm 3.5 core laid in trenches or passing through pipes, ducts or fixed to walls/poles complete all as specified and directed by Engr-in-Charge. Make as per PS.
Supply and laying, jointing and testing cable, LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor in size 16 Sqmm 2 core laid in trenches or passing through pipes, ducts or fixed to walls/poles complete all as specified and directed by Engr-in-Charge. Make as per PS.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits,manholes, pier holes, etc. N exc 10 sq m on plan and n exc1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed by Engr-in-Charge.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n exc. 1.5 m above the starting point., complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning to underground cables 8cm below the cable before laying and 15cm above the cable after layingc complete all as specified in clause 19.75 of SSR PART -I complete all as specified and directed. Note: Punned thickness of 18cm shall be measured and paid under this item.
Supplying and laying un-reinforced, factory made, machine pressed,precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 25X4 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 3 of MES SSR Part I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed. Note- (i) earth resistance not more than 1.0 OHMS.Writing of details on the surface of the pit with paint. (ii) In case earth resistance more than 1.0 ohms, the contractor wiil re earthing at no extra cost. (iii) On testing, if the earth resistance less than specified is not obtained, earthing will be regenerated at NO EXTRA COST till the desired earth resistance is obtained. Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
M&L for sub main wiring with earth wire with the size Two runs of 10 Sqmm (2x 10 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 10 Sqmm (1x10 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x 10 Sqmm), 1 run of 10Sqmm (1x10 Sqmm) cable and one metre of casing caping will be measured as one unit.
Supply and fixing MCB distribution board Double door, regal grey, sheet metal enclosure, TPN vertical 240 volts 4 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc complete all as specified and directed
Supply and fixing MCB TPN 63 Amps, 'C' series, 415 V A/C complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB SP 6 to 32 Amps, 'C' series, 240 V A/C complete all as specified and as directed by Engineer-in-Charge.
M&L for 100 mm bore medium grade galvanished iron water tubing with all fittings like sockets, union, bend and elbows etc laid in floors or trenches complete all as specified and directed.
M&L for 80 mm bore medium grade galvanished iron water tubing with all fittings like sockets, union, bend and elbows etc laid in floors or trenches complete all as specified and directed.
M&L for 50 mm bore medium grade galvanished iron water tubing with all fittings like sockets, union, bend and elbows etc laid in floors or trenches complete all as specified and directed.
M&L for 40 mm bore medium grade galvanished iron water tubing with all fittings like sockets, union, bend and elbows etc laid in floors or trenches complete all as specified and directed.
M&L for 25 mm bore medium grade galvanished iron water tubing with all fittings like sockets, union, bend and elbows etc laid in floors or trenches complete all as specified and directed.
S&F cast iron sluice valve 100mm dia with CI drilled flanged ends class PN - 1.6 confirming with IS including stainless steel spindle and iron wheel including jointing material complete such as rubber packing rings of adequate size and requisite number of nuts bolts and washer complete all as specified and directed by Engineer-in-Charge.
S&F cast iron sluice valve 80mm dia with CI drilled flanged ends class PN - 1.6 confirming with IS including stainless steel spindle and iron wheel including jointing material complete such as rubber packing rings of adequate size and requisite number of nuts bolts and washer complete all as specified and directed by Engineer-in-Charge.
S&F Gun metal globe or gate valve ISI marked 50 mm bore cast with iron wheel head, screwed both ends for iorn pipe and fixed complete all as directed by Engr -in- Charge.
S&F Gun metal globe or gate valve ISI marked 40 mm bore cast with iron wheel head, screwed both ends for iorn pipe and fixed complete all as directed by Engr -in- Charge.
S&F Gun metal globe or gate valve ISI marked 25 mm bore cast with iron wheel head, screwed both ends for iorn pipe and fixed complete all as directed by Engr -in- Charge.
Material and labour for construction of stone masonary valve pit size 90x90x120cm (internal dimension) built in cement mortar 1:4 including plastering 20mm thick internally and externally in CM 1:4 PCC 1:4:8 Type D-2, 15 CM thick in foundation extending 10 beyond external faces of wall around PCC flooring 1:2:4 type B-1, 40mm thick cover made out of 3.15mm thick MS round bar and locking arrangement with lock 2 keys, MS sheet cover should be painted with two coats of enamelled paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
S&F cast iron air release valve flanged type heavy duty grade single outlet air release valve 50mm bore and fixing upto 80/100 dia CI/DI/GI pipe including suitable adopter, rubber hinged sheet, nut bolt etc complete all as specified and directed by Engineer-in-Charge.
S&F installation and testing of monoblock pump set suitable for 415V, 3 phase of capacity 10 HP with necessary connection copper cable from starter panel complete all as specified and directed by Engineer-in-Charge.
S&F of automatic star delta starter with over load protection 3 phase with complete accessories as per standard specification for operating upto 10 HP pump/motors including necessary connections and testing on completion complete all as specified and directed by Engineer-in-Charge.
S&F 500 litres rotational moulded polyethylene water storage tank, inner and out white, triple layers, ISI marked (cylinderical vertical with closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part-I including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, complete all as specified and as directed by Engr-in-Charge.Make as per PS.
S&F 1000 litres rotational moulded polyethylene water storage tank, inner and out white, triple layers, ISI marked (cylinderical vertical with closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part-I including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, complete all as specified and as directed by Engr-in-Charge.Make as per PS.
S&F 25 mm bore ball brass valve high pressure with polythene float and fly nuts complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engr-in-Charge.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge.
Supply, installation and Commissioning of UPS for 30 min backup single phase AC input 160 V to 260 V and output 230 V ± 1 of capacity 3 KVA with required Nos of battery with all accessories complete all as specified and directed by Engineer-in-Charge.
S&F sub main wiring with earth wire with the size two runs of 4 Sqmm (2x4 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 4 Sqmm (1x 4 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x 4 Sqmm), 1 run of 4 Sqmm (1x 4 Sqmm) cable and one metre of casing caping will be measured as one unit.
S&F sub main wiring with earth wire with the size two runs of 2.5 Sqmm (2x 2.5 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 2.5 Sqmm (1x 2.5 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 2.5 Sqmm (2x 2.5 Sqmm), 1 run of 2.5 Sqmm (1x 2.5 Sqmm) cable and one metre of casing caping will be measured as one unit.
Supply and fixing MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc complete all as specified and directed
Supply and fixing MCB SPN 40 to 63 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully copper/Aluminum point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc complete all as speciifed and directed by Engr-in-Charge
M&L for point wiring for one light point or fan point controlled by one light/exhaust fan controlled by one way switch with PVC insulated FRLS copper conductor stranded cable of size 1.5 sqmm and including PVC casing/caping terminated in pressed steel terminal boxes for fixing and 1.5 sqmm PVC insulated copper wire as earth wire connected to earth wire connected to earth folly and 3.0mm thick plastic laminated sheet cover all as specified and directed by Engr-in-Charge.
All as per item No 40.00 here-in-before but 1.5 Sqmm for one 3 pin 6 Amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the same board complete all as specified and directed by Engr-in-Charge.
All as per item No 40.00 here-in-before but 1.5 Sqmm for one 3 pin 6 Amps socket outlet including 1.5 sqmm insulated copper wire as earth wire to the same earth dolly on the independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 40.00 here-in-before but one socket outlet 15 Amps 3/5 pin with PVC copper conductor cable multistrand unsheathed on independent board cable of size 2.5 sqmm including one run 2.50 Sqmm PVC copper conductor cable multistrand unsheathed for earth continuty complete all as specified and directed by Engr-in-Charge.
S&F in replacement for switch socket combination 2 in 1,3 pin, 5 and 15 Amps flush type universal, ISI marked complete all as specified and directed
S&F in replacement switch socket combination 2 in 1,3 pin, 5/6 Amps 230 Volts flush type universal, ISI marked complete all as specified and directed
S&F in replacement for socket outlet 3Pin, 5A, flush type complete all as specified and directed
S&F in replacement for switch piano flush type one way single pole 5 Amp 240 volts, ISI marked complete all as specified and directed
S&F surface/wall mounted LED fittings with LED tube 18 watts, 6000K capacity decorative ultra slim round profile, powder coated CRCA decorative for LED tube 1x18W LED including LED retrofit, LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 4 feet long type bracket including necessary connection prewired and making connection with 0.75 Sqmm 3 core copper flexible cable of appropriate size from ceiling rose/PVC conductor to light fittings with complete accessories complete all as specified and directed. Make: As per PS
S&F LED mirror light fitting 7 watt 230 volt box type with standard specification etc warm white colour complete all as specified and directed
S&F LED lamp 7 watt 230 volts 50 Hz AC complete all as specified and directed
S&F ceiling rose surface bakelite 65x50 mm two to three terminals.all as specified and directed by Engr-in-Charge.
S&F lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings as specified and directed by Engr-in-Charge.
Supply and fixing in replacement MCB distribution board Double door, regal grey, sheet metal enclosure, TPN vertical 240 volts 4 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc complete all as specified and directed
Supply and fixing in replacement MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc complete all as specified and directed
Supply and fixing in replacement MCB SP 6 to 32 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB SPN 63 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB TPN 63 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge.
S&F sub main wiring with earth wire with the size two runs of 4 Sqmm (2x4 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 4 Sqmm (1x 4 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces including taking down old existing sub main wiring complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x 4 Sqmm), 1 run of 4 Sqmm (1x4 Sqmm) cable and one metre of casing caping will be measured as one unit.
Supply and fixing of wireless calling bell system for 16 beds including centralisez receiver with buzzer system, indication lights and bed indication for 16 beds with 16 Nos of remote which will be fixed near patients complete all as per specified and directed by Engineer-in-Charge.
Supply and laying, jointing and testing cable, LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty 1100 volts grade with stranded aluminium conductor in size 16 Sqmm 3.5 core laid in trenches or passing through pipes, ducts or fixed to walls/poles including taking down old unserviceable cable complete all as specified and directed by Engr-in-Charge. Make as per PS.
SATISH KUMAR AND SONS
M/S GLOBAL ENGINEERS
N K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .