Maj Srinath PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR/ MAINT OF DG SET CANTT AND COD AREA AND REPAIR/ MAINT OF SWIMMING POOL AND STP AT GE(I) KANPUR UNDER GE (I) KANPUR CANTT
2022_MES_547300_1
GE(I)/KAN/T-53 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (I) KANPUR
₹74,720
Yes
14 Nov 2022
25 Aug 2022
29 Sept 2022
25 Aug 2022
27 Sept 2022
8 Sept 2022
Amount
Reapir/servicing to complete DG set any make/model 125 kVA to 380 kVA of any make water cooled diesel engine by taking out dismantling segreagation of all parts and reassembling after duly repair/replacement of following new part fixing including all type machine work such as turning reaming etc washing cleaning,greasing,wires,gaskets,V belts,rubber hoses,cleaning of alternator by vacuum cleaner and greasing of bearing,replacement of engine oil, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule.
S&F in replacement of Lub oil filter element for 125 to 380 kVA DG set as per sample all as specified
S&F in replacement of Fuel filter element for 125 to 380 kVA DG set as per sample all as specified
S&F in replacement of dry type air cleaner for 125 to 380 kVA DG set as per sample all as specified
S&F in replacement of V-belt of fan for 125 to 380 kVA DG set as per sample all as specified
S&F in replacement of bye pass filter for 125 to 380 kVA DG set as per sample all as specified
S&F in replacement of starting relay for 125 to 380 kVA DG set as per sample all as specified
S&F in replacement of Electronic governer Assy for 125 to 380 kVA DG set as per sample all as specified
M&L for repalcement of complete wiring (copper multistrand cable) of DG set control panel any capacity as directed at site including thimble screw and sleaves etc.
S&F for replacement of gauge lub oil pressure of DG set cap 125 to 380 kVA as per sample all as spfd.
S&F in replacement of hose pipe for of DG set cap 125 to 380 kVA as per sample all as spfd.
S&F in replacement of radiator hose pipe of DG set cap 125 to 380 kVA as per sample all as spfd.
Dismantling and taking out fuel injector pump assembly suitable for 125 to 380 kVA DG Set and complete overhauling of FIP including replacement of unserviceable parts like rebuild overhauling kit, rebuild seal kit, fuel injector 'O' rings, OEM gaskets, spring gasket injector, valve bearing etc complete all as specified.
S&F in replacement of Clamp hose radiator of 125 to 380 kVA DG set as per sample all as spfd
S&F in replacement of water body of DG set 125 to 380 kVA as per sample all as spfd.
Taking out Turbocharger of DG set Cap 125 to 380 kVA and replacement of Compressor Housing,Compressor Wheels,Turbine housing,Turbine Wheel,Wastegate Acuator with clamps,setting, caleberation and testing complete
Dismantling and taking out self starter assembly suitable for 125 to 380 kVA DG Set and replacement of wornout spare parts like field coil, armature assembly, solenoid assembly, corbon brush, corbon brush assembly, clutch plate assembly and bushes including servising and refixing to engine complete all as specified.
S&F in replacemnt of AVR (Automatic Voltage Regulator) for DG set of capacity 125 to 380 kVA kVA as per sample all as spfd.
S&F in replacement of rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24/ 12 V DC full wave rectifier unit as per sample for DG set 125 to 380 kVA as site rquirement.
Repair of PT (Pressure time) fuel pump by dismantling and segration all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, calibration for DG set of capacity 125 to 380 kVA & testing on completion.
Repair to rediator assy cleaning washing throughly, descaling and M&L for replacement of rubber size pad and MS Nut & bolts including brazing / repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling complte incl nut, bolt, washer & spring any type of DG set capacity 125 to 380 kVA complete
Cleaning decarbonishing complete and spray painting to complete DG set canopy outside of capacity 125 to 380 kVA icluding writing SM No Srl No Make capacity & date of installation as per sample all as directed.
Dismantling and taking out battery charging alternater assembly suitable for 62.5 KVA DG Set and replacement of wornout spare parts like field coil, rotor assembly, corbon brush, rectifier assembly and bushes etc including servising and refixing complete all as specified.
S&F in microprocessor digital typr DG set controller of DG set of capacity 125 kVA to 380 kVA (Make of DG set Cummins & Greaves cotton) including connect all control wiring & programming all the parameter related to DG set at site complete.
S&F in replacement of automatic battery charger AC input 230+10% V output DC for 12/24 volt battery current 10-15 Amp for 2 Nos battery at a time with digital ammeter & Voltmeter .
S&F in replacement battery terminal bolt type suitable for any type of battery
S&F for battery lead of PVC insulated copper conductor, single core 25 Sqmm, multistranded cable with suitable terminals at both ends of length as per site requirement complete all as specified and directed.
Disconnecting incoming / outgoing cable connection from alternator of 125 to 380 kVA DG set and taking out from DG set room checking carefully and transporting to auth workshop for repair and rewinding of alternator dismentling into parts and cutting the burnt/damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete include water load test all as specified and directed by Engr-in-charge. NOTE: All neccessary T&P for dismantling,transporting and installation cost is deemed in this work
Reapir/servicing to complete DG set any make/model 50 to 75 kVA water coolent diesel engine by taking out dismantling segreagation of all parts and reassembling after duly repair/replacement of following new part fixing including all type machine work such as turning reaming etc washing cleaning greasing , wires replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule.
Same as above item no 29 but of cap 20 kVA
S&F in replacement of Lub oil filter element for 50 to 75 kVA DG set as per sample all as specified
Same as above item no 31 but of cap 20 kVA
S&F in replacement of Fuel filter element for 50 to 75 kVA DG set as per sample all as specified
Same as above item no 33 but of cap 20 kVA
S&F in replacement of dry type air cleaner for 50 to 75 kVA DG set as per sample all as specified
Same as above item no 35 but of cap 20 kVA
S&F in replacement of V-belt of fan for 20 to 75 kVA DG set as per sample all as specified
S&F in replacement of bye pass filter for 50 to 75 kVA DG set as per sample all as specified
Same as above item no 38 but of cap 20 kVA
S&F in replacement of Electronic governer Assy for 50 to 75 kVA DG set as per sample all as specified
S&F in replacement of starting switch for 50 to 75 kVA DG set as per sample all as specified
Same as above item no 41 but of cap 20 kVA
M&L for repalcement of complete wiring (copper multistrand cable) of DG set control panel of capacity 62.5/75 kVA as directed at site including thimble screw and sleaves etc.
S&F for replacement of gauge lub oil pressure of DG set cap 50 to 75 kVA as per sample all as spfd.
S&F in replacement of hose pipe for of DG set cap 50 to 75 kVA as per sample all as spfd.
Same as above item no 45 but of cap 20 kVA
S&F in replacement of radiator hose pipe of DG set cap 50 to 75 kVA as per sample all as spfd.
Dismantling and taking out fuel injector pump assembly suitable for 50 to 75 kVA DG Set and complete overhauling of FIP including replacement of unserviceable parts like rebuild overhauling kit, rebuild seal kit, fuel injector 'O' rings, OEM gaskets, spring gasket injector, valve bearing etc complete all as specified.
Same as above item no 48 but of cap 20 kVA
S&F in replacement of Clamps for hose rediator of DG set 20 to 75 kVA as per sample all as spfd
S&F in replacement of water body of DG set 50 to 75 kVA as per sample all as spfd.
Same as above item no 51 but of cap 20 kVA
Taking out Turbocharger of DG set Cap 50 to 75 kVA and replacement of Compressor Housing,Compressor Wheels,Turbine housing,Turbine Wheel,Wastegate Acuator with clamps,setting, caleberation and testing complete
S& F in replacement Turbo charging assembly of DG set 50 to 75 kVA as per sample
Same as above item no 54 but of cap 20 kVA
S&F replacement of self starter 12/24 volt for Dg set 20 to 75 kVA as per sample all as spfd.
S&F in replacement of AVR (Automatic Voltage Regulator) for DG set of capacity 50 to 75 kVA as per sample all as spfd.
Same as above item no 57 but of cap 20 kVA
S&F in replacement of rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24/ 12 V DC full wave rectifier unit as per sample for DG set 20 to 75 kVA as site rquirement.
Repair of PT (Pressure time) fuel pump by dismantling and segration all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, calibration for DG set of capacity 20 to 75 kVA & testing on completion.
Repair to rediator assy cleaning washing throughly, descaling and M&L for replacement of rubber size pad and MS Nut & bolts including brazing / repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling complte incl nut, bolt, washer & spring any type of DG set capacity 20 to 75 kVA.
Cleaning decarbonishing complete and spray painting to complete DG set canopy outside of capacity 20 to 75 kVA icluding writing SM No Srl No Make capacity & date of installation as per sample all as directed.
Disconnecting, dismantling & repair to dynamo with segregation of all parts supply and fix in replacement of armature field, coil carbon bush and bearing etc reassembling of capacity 63 to 75 kVA DG Set complete & testing on completion.
Same as above item no 63 but of cap 20 kVA
S&F in microprocessor digital type DG set controller of DG set of capacity 63 to 75 kVA (Make of DG set kirloskar & Greaves cotton) including connect all control wiring & programming all the parameter related to DG set at site complete.
Disconnecting incoming / outgoing cable connection from alternator of 63 to 75 kVA DG set and taking out from DG set room checking carefully and transporting to auth workshop for repair and rewinding of alternator dismentling into parts and cutting the burnt/damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete include water load test all as specified and directed by Engr-in-charge. NOTE: All neccessary T&P for dismantling,transporting and installation cost is deemed in this work
Same as above item no 66 but of cap 20 kVA
M&L for replacement of coolant for DG set of make : Castrol/ Indian Oil/ equivalent.
M&L for replacement of Engine oil 15W30/20W40/15W40 (As per OEM recommendation) complete all as spfd make : Valvoline/ others only recommended by concerned DG set OEMs
S&F in replacement of starting switch of DG set upto cap 63/75/380 kVA as per sample all as specified and directed
Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set all as spfd.
Repair/ overhauling of self starter 12/24 Volts of any make/capacity including replacement of minor items such as carbon bushes, nuts, bolts, etc as per site requirement complete all as specified and directed. Note: All additional spares as required for smooth functioning of DG set complete all as spdf & as dirceted.
S & F in replacement lead acid battery 12 volts 180 AH heavy duty maint free complete including initial charging complete all as specified and directed. Make: AMARON HIWAY Automotive Battery - NTX00D04R (AAM-HW-NTX00D04R)/ 180AH Exide Xpress XP 1800/Others recommended by OEM
M & L in replacement of Flame proof asbestos rope of specicfed dia wrapped around th exhaust pipe complete all as directed.
Supply & pouring distilled water for maint of batteries complete all as specified & as directed
Supply & fix in replecement Battery bank 30V /100 Amp (2 V per cell of 15 Cells) including connections to the existing voltage charger complete all as specified by Engr-in -charge
Supply & fix in replecement Variable Dimmerstate 3 Amp cap for volatage charger complete all as specified by Engr-in -charge
Supply & fix in replecement Transformer copper wound 30V/10V complete with connections for volatage charger complete all as specified by Engr-in -charge
Supply & fix in replecement Diode 40amp/500 V complete with connections for volatage charger complete all as specified by Engr-in -charge
Supply & fix in replecement charging card complete with PCB wiring for volatage charger complete all as specified by Engr-in -charge
Supply and fix in replacement Off load change over switch with MS/SS enclosure 100 amps 415 volts 4 pole 50 Hz open execution type with rotary type handel operated complete all as directed by Engr In Charge. Make :- Havells/ABB/LT
S & F in replacement Air circuit breaker 1000 A cap 3P, 50 kA manual draw out type thermal magnetic type ,micropro – communication compatible with RS485 modbus protocol conforming to IS/IEC 60947-2 & IEC 60947-2, Dual spring balanced mechanism com[plete with all accessories as per spe cified amd directed by Engr-in-charge. Make : C&S/Seimens/ABB/Legrand
Supply and fix in replacement Gate light fitting LED type 25 W with CCT not less than 5700 K ,and IP 65 Protection ,230V recessed mounting mirror opticluminare complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, Make : Havells /HPL/Indoasian complete including wire and making connection complete with pole all as specified and directed by Engr-in-charge.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections used for security light connections from cable to beacket on poles, twin core cable flat or circular 10 sqmm solid conductor complete all as specified and as directed.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 400 Amps 35/36 kA, Fixed Thermal & Fixed Magnetic setting Ics = 100% of Icu Make : Legrand/Siemens / Schneider /L&T/ABB
All as per item No 85 but MCCB 250 Amps 35/36 kA.
All as per item No 85 but MCCB 100 Amps 16 kA.
All as per item No 85 but MCCB 160 Amps 25 kA.
All as per item No 85 but 63 Amps 16 kA.
S & F in replacement lead acid battery 12 volts 7 Ah heavy duty maint free complete including initial charging complete suitable for Lift Make OTIS all as specified and directed. Make: Exide/Amron/As per recommendation of OEM
S & F in replacement emegency car light as per sample of Lift Make : OTIS all as specified and directed by Engr-in-charge
M & L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron frame fixed on RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar not less than 40X5mm suitable for 500 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T,suitable for and including one incoming MCCB 400 Amps 3 pole 35/36 kA, Three Nos 100 Amps 4 pole 25 kA, two Nos 63 Amps16 kA as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as required at site or directed. Make : As per Makes approved by CELZ Note: All MCCBs should have Fixed thermal and fixed magnetic setting and Ics = 100% of Icu(Make of MCCB: L&T/C&S/Havells/ABB)
Maintenance of station swimming pool including brushing the inside the entire pool having bottom area 400 Sqm, side wall having an area 300 Sqm, 100 meter long scum channel and having 250000 gallons entire capacity of water. Filter capacity of the pool is 150 Cum/Hour with pressure type pumps of capacity 5 HP and having chlorine plant to maintain 2 PPM of chlorine in the pool water and PH level between 7 to 8 all over complete all as specified and as directed including the followings:- (i) Suction sweeping the bottom of the entire pool two time in a day by a trained operator by using suction sweeping pump set connected with 40 mm size flexible rubber hose and tied with 12 mm nylon rope to the handles on either side for moving the sweeper in all direction for removing sediment. (ii) Removing all floating particles by using net in a regular interval of one hours. (iii) Feeding of chemicals in required proportion on Sunday/Monday as per requirement of swimming pool.
Supply only high density synthetic float ball of size 6" (150 mm) with double hook for suction sweeper al as specified.
Supply only flexible hose pipe ribbed type high density of 40 mm size.
S& F nylon brush with superior quality of size as sample made out of water resistant wooden block with thickly insert nylon strings for using sweeping
S& F nylon rope 12 mm for the suction sweeper
S& F aluminimum alloy telescopic rod , top dia 30mm and bottom dia 28 mm with detachable superior quality brush ISI marked of size 6 mtr expanded upto 12 Mtr for brushing the entire area of swimming pool.
Supply only bleaching powder ISI marked superior quality Make- Bihar Coustic & Chemical/Hybird
Supply only poly aluminimum cloride (PAC) COAGULANT CONTAINING APPROX 29% Al2O3 with bacity of approx 64% packed all as specified (Rayalaseema chemicals /Potter & Watts/Grasim industries).Note:For Sl item 9-13 labour cost for mixing shall be included in item No 01 above.
Supply and fixing in replacement High pressure guage circular dial up to 5 Kg/Sq.cm confirming to IS Make-Aqua Services (Make:- H-Guru/Jackson )
Supply only Ortho- Toliding solution for testing of disolved chlorine in water.
Supply and fixing in replacement superior quality detachable type telescopic brush suitable for telescopic rod of 30mm dia(bottom 28mm dia) .
Supply and fixing in replacement leaf net for removing floating particles from both swimming pool surface every day in the morning and evening time all as diredcted by the Engr-in-charge
Supply only chlorine testing kit comprising of samples of chlorine contents in seald tube from 0.1 to 2.0 PPM and othotodoline solution , testing tube complete all as specified and as directed.
S & F of Electric cable for submersible pump set, flat 2.5 Sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed. Make- Finolex/ Paragon/Havells
M & L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 63 Amp-08, suitable for and including one incoming MCCB 200 Amps 4 pole 35/36 ka, One Nos 100 Amps 4 pole 25 ka, One Nos 63 Amps 25 ka as outgoing, 4 DOL Starter for operating 5 HP monoblock Pump,Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work at COD Estate gate as required at site complete all as required at site or directed.
S&F of high rate pressure sand filters bobbin wound fibre glass reinforced laminated filter of 1200 mm with UV resistant surface finish, reliable to operate under prolong sunlight for years, designed for easy inspection of quartz filter media with a six position, 50 mm multiport valve and ABS lateral with quartz filter media complete with all required materials incl dismantling of old, all materials as required at site, fixing arrangements and testing on completion all as specified and directed. Mkae : HIBIRD or Equivelent.
Comprehensive all type of maintenance major or minor of Sewage Treatment Plant (STP) of capacity 100 cum/KLD including necessary repairing of pumps, motors, oiling, greasing, desludging etc and dozing of bleaching powder and running maintenance of horticulture pipe line within campus as per directions and satisfaction of Engineer-in-Charge and as working details are as under:- (a) The contractor will attend all major and minor troubleshooting & break down within 24 hrs from the time of call. (b) The contractor will test treated water for BOD, COD, TSS and oil grease in two times once in six month and submit report accordingly. Note:- The test result for BOD, COD, TSS and oil grease will be in permissible limit as required.(d) De-sludging of plant as per site requirement will be done but not minimum once in every 3 months as directed. Sludge will be disposed off out side MoD land (f)The unit rate quoted by the Contractor shall be deemed to be included for repairing/ rewinding of all equipments, fittings, fitness pipes, valves, civil works, etc which get damaged during operation of plant. The unit rate quoted shall also be deemed to be included providing stand by pumps for draining out sewage water sump well as per requirement, in case of breakdown of plant. No extra cost will be entertained on this regard in future.(g) Day to day general maintenance and servicing of various pumps will be done by the contractor as per requirement.(h) Following regular/ preventive maintenance to be carried out by the Contractor for smooth functioning of STP:- (i) General maintenance of the system. (ii) Complete checking and running of the system.
(iii) Checking and cleaning of feed pump and sewage pumps and blowers. (iv) Cleaning and backwash of sand filter. (v) Cleaning and backwash of carbon filter. (vi) Replacing of any spares required, (vii) Overhauling of motors and pumps. (viii) Addition/ replacement of FMR media if required. (xi) Checking of dosing chemicals and pumps. (x) Physical checking of running of plant. (xi) Supervising and guiding for desludging if required. (xii)Any other essential item or items not mentioned above to maintain functioning of STP. (i) Repair/ Maint of plant will be carried out by skilled/ trained personels only (ii) Examine periodically all safty issues. (iii) The necessarry T & P/ safty equipments required shall be arranged by the Contractor and cost of the same shall be deemed to be included in the quoted rate. (iv) All material of STP installation will be handed over to Contractor for safe custody at the time of commencement of CA and at the time of completion of the work Contractor will be handed over the same all material to department.
M&L for rewinding of monoblock pump motor of capacity 5.5 KW/1500 RPM with PVC insulated copper wire of existing gauge as per motor capacity using new insulation material such as insulating paper sleeves etc. Including cleaning and replacement of defective parts and testing complete, replacement of cable as required length all as directed.
DEO Traders
SUSHMANAND ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .