Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹32.3 L+₹98,853.40 (3.16%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹35.2 L+₹3.9 L (12.4%)Rejected-Finance 0 CIVIL LINES TETARI BAZAR TETARI BAZAR NAUGARH SIDDHARTHNAGAR UTTAR PRADESH 272207 | SIDDHARTH NAGAR | UTTAR PRADESH | 272207 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹40.2 L+₹8.8 L (28.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹42.9 L+₹11.6 L (37.0%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹47.8 L
EMD Value
₹97,640
Closing Date
14 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR
PROVN OF HIGH MAST LIGHT, VIEW CUTTER IN PERIMETER WALL AND SPECIAL REPAIR TO PERIMETER WALL AT 4AFSB VARANASI UNDER GE AF STN GORAKHPUR
2023_MES_615366_2
9089/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
Class D cat a i
8 documents required · 8 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹97,640
Yes
27 Jan 2024
20 Nov 2023
16 Dec 2023
20 Nov 2023
14 Dec 2023
30 Nov 2023
20 Nov 2023 - 23 Nov 2023
Amount
Dismantling carefully concertina coil 610 dia with razor wire and refixing on the same/and other position.Complete all as specified and directed.
Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc, complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for Complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry built in cement mortar.complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified and directed.
S&F mild steel posts and struts in fencing including cuttings tops to shape as directed, drilling holes, nothcing for wire etc flat iron fillets (for securing wire mess etc) including all necessary drilling, bolting, welding or riveting etc and similar work including taking down existing mild steel work i.e "Y' shaped .Complete all as specified and directed.
S&F steel work in tubular Post/ trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St-240 including all necessary work as directed by Engr in Charge. Complete all as specified and directed.
S&F 610mm dia punched tape concertina coil (effective dia 550 mm at stretch length of coil 6m) with two handel and spikes at both end of coil with dovetail clips 18 SWG, including razor wire 7 No, 6m length of each wire medium size, barbed length 20mm width 14mm, inclduing 51 pins, 128 nos of clips in each coil including 230 gm/Sqm zinc coarting on core wire including taking down existing old concertina coil complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of dark green/Blue colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws.Complete all as specified and directed.
M&L for preparation of previously untreated steel and iron surfaces of any description not otherwise decribed over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer Complete all as specified and directed.
M& L for cement concrete type B2, 1:2:4 (40mm graded aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts, as fixing "Y' shaped MS angle on walls,(including caps and bases). Complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any descrition,over 10 cm width or girth and applying one coat of synthetic enamel paint (any coulour) .complete all as specified and directed.
M&L for preparing plastered surfaces of wall and applying two coats of cement based paint over a coat of primer. Complete all as specified and directed.
M&L Rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point. Complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Compete all as specified and directed.
M&L for Cement concrete Type D2, 1:4:8, (40 mm graded aggregate) in foundations,filling and mass concrete.complete all as specified and directed.
M&L for Brick work with subclass 'B'bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6.Compete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs exc 5 cm wide but n.exc 10 cm and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work.complete all as specified and directed.
Providing cement concrete Type B1, 1:2:4, 20 mm graded aggregate as in copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Supply , installation comissioning and testing of High galvanized mast light of 16 mtr height suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike,required earthings including RCC foundation as per height and as recommended by manufacturer OEM complete all as specified below and directed. Make Crompton Cat ref HM-16A-LM-ACC or equivalent in BAJAJ/Havells/Wipro (i) Material of construction BSEN 10025. (ii) Section thickness for top : 3 mm andand for bottom : 4mm. (iii) Top (A/F) 150mm and Bottom (A/F) 360mm. (iv) Lantern carriage shoud be for 09 Nos having 09 arms in symmetrical orientation. (v) Dynamic loading should be double drum and capable to bear wind load 180 Kmph. (vi) Stainless steel wire rope of AISI 316 grade of construction 7/19 & dia 6 mm having breaking capacity 2350 Kg .Nos of ropes used 2 for winch and 3 for lantern carriage. (vii) Trailing cable of 5 core 2.5 Sqmm flexible. (viii) Power tool used 415 Volt 3P +N operated by integral motor. (ix) All other accessories required as recommended by OEM/manufacturer. Note : Contractor has to take necessary approval of design/drawing of foundation of high mast light after carry out soil testing and rate for the same are deemed to be included in quoted rate by the contractor.
Supply and fix LED Flood light 200 W, 230 V AC, IP 66 haning surge protection 4KV, and lumin not less then 24000 lumen including necessary electric connection with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed .Make Philips / Havells / Crompton / Bajaj.
Supplying,installation,testing,commissioning of LT panel board 3 phase 4 wire system outdoor type factory made free standing,floor mounting with suitable PCC foundation dust and vermin proof cubical type (back door opening) interlocking arangement (IP- 55 protection) fabricated with 3.16 mm CRCA sheet with Anti corrosion coating & finnaly plyester powder coated of finite green fully compartment with providing with suitable size of aluminum strip all as specified for the following. (a) Incomming :- (i) MCB TPN 'C' curve 63 AMPS 415 Vollts 10 KA -01 No. (ii) Digital type amp meter 0-100 Amp with CT's 03 Nos. (iii) Digital type voltmeter 0-500 Volts -01 No. (iv) Indicating lamps (RYB) 01 set of 3. (v) Copper bus bar rating 150 Amps 3 phase neutral-01 set. (vi) Chamber for incoming & outgoing cable. (b) Outgoing :- (i) MCB TPN 32 AMPS C curve 415 Volts -01 No. (ii) Din rail multifunction digital timer switch Make GIC model 67DDTO -01 Nos. (iii) Power contactor 4 pole 40 amps Make L & T Cat No. MCX 12 model No CS97014-01 Nos. (iv) Remote for up and down of Lantern Carriage of high mast light through integral motor. (v) Connector terminal for connection of out going LT cables.Make: L&T power syatem & control Jalandhar/ABB/Indo Asian for high mast light.
Voltage stabilizer for unbalanced load automatic operation, three phase naturally oil cooled indoor type of capacity 300 KVA having overall load and earth fault protection and inbuilt by pass arrangement with first filling of insulating oil complete with the following specifications :- Make of Voltage Stabilizer :- Servokon/ITE Gurgaon/AE/Vintek Electronic (Volina) A. General specification :-(i) Overall Efficiency - More than 98% (ii) Power Factor - 0.95 to 1.0 (iii) Response time - Voltage Stabilizer Per Second is instantaneous (Mill Sec 0.05 Sec) (iv) Voltage Stabilization time - <2 second if input voltage is at 100 ± 10 % of rated voltage (v) Voltage Endurance - 2000 Volts/1 Minute without puncture (vi) Insulation resistance - > 3 MΩ (vii) Frequency - 50 Hz (viii) Voltage Stabilizer should have Servo controlled, naturally oil cooled type with Auto operation B. Output :- (i) Wave form Distortion - Virtually Nil C. Protection :- (i) Voltage Stabilizer should have High Voltage, Low Voltage, Phase failure and By-pass arrangement with Alarm device. (ii) Over load capacity - 150% for 30 Second (1 Min at the rated current of 2 times) D. System Display :- (i) Power indicator (ii) Voltage indicator (iii) Abnormal Status (iv) Power Factor indicator E. Environmental Condition :-(i) Ambient temperature - -5°C to 45 °C (ii) Humidity - 0 % - 90 % RH (iii) Noise level - < 55 dBA (iii) Noise level - < 55 dBA (iv) Height - 81 Meters (above means sea level) F. Input Voltage :-(i) Input Voltage - Between 300 Volts to 480 Volts G. Output Voltage :- (i) Output Voltage - Output Voltage stabilized at any desired voltage between 400 Volts to 440 Volts (ii) Speed correction - 8 Volts Per Second(iii) Accuracy - ± 2.5 %
M & L for PCC plateform of Voltage Stabilizer of capacity 300 KVA having approximate size 2 M x 2 M x 0.15 mtr high from GL by necessary excavation in trenches PCC 1:5:10 type E2 for foundation brick work in cm 1:6 PCC, 1:2:4 type B1 in copping plaster 10 mm thick in cm 1:6 on brick/complete surface PCC 1:4:8 type B1 sub base 75 mm thick as in floor PCC 1:2:4 type B1 100 mm thick floor using extra cement returning filling and removal on surplus soil not less than 50 m complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate 600X600X6.3 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside Welding / brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed.
Supply and laying ,jointing and testing XLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 240 sqmm 3.5 core.Make: Havells/Polycab/Gloster
Supply and laying ,jointing and testing XLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 10 Sqmm 4 core.Make: Havells/Polycab/Gloster
Excavation in trenches n.exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces for laying of cable complete all as specified and directed.
Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditecte and only punned thickness of sand will be measured and paid.
Supply & laying brick for protection of cable sub class 'B' laid dry flat across the cable with width equal to the length of whole bricks complete all as specified and ditected.
Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed.
Removal surplus soil at a distance n. exc. 50 m and deposited where diredted at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed.
Labour for boring, holes by using necessary T &P required for inserting of 50/80 mm bore GI pope under the road/hard standing or any other location not less than 1200 mm deeep complete all as specified and ditected.
M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.Make: TATA/JINDAL/Swastik
M & L GI pipe 80 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed.Make: TATA/JINDAL/Swastik
R.S Enterprises
PANDEY TRADERS
GAYDIN CONSTRUCTIONS
M/S DEEKSHA CONSTRUCTION
M/s SKP CONSTRUCTION
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .