Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC JAISALMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.2 L+₹2.7 L (14.6%)Rejected-Finance 1286 TOTA RAM KI DHANI JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹23.9 L+₹5.4 L (29.4%)Rejected-Finance 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹24.5 L+₹6.0 L (32.5%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹27.5 L+₹9.0 L (48.8%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹30.1 L
EMD Value
₹60,500
Closing Date
4 Mar 2024, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER-345001
PROVN OF MODERN COOK HOUSE AND DINING HALL AND PROVN OF ONE OPEN SHED WITH THREE SIDED COVERED WALL BEHIND NEAR BLDG No P 642 UNDER GE(A) JAISALMER
2024_MES_641227_1
84157/E8
Open Tender
Civil Works
Item Rate
180 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (A) Jaisalmer
₹60,500
Yes
19 Mar 2024
7 Feb 2024
6 Mar 2024
7 Feb 2024
4 Mar 2024
21 Feb 2024
7 Feb 2024 - 12 Feb 2024
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and not exc exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/disintegrated rock complete all as specified and directed by Engineer-in-charge.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-charge.
M&L for Precast cement concrete solid block masonry exc 10cm in width and setting in CM 1:6 type C-1, 1:3:6 (using 20 mm graded granite stone aggregate) complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick on surface of stone masonry or surface other than fair face of brickwork in CM 1:6 is to be finished even and smooth (without using extra cement) complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, finishing the surfaces even and smooth (without using extra cement) complete all as specified and directed by Engineer-in-charge.
M&L for Preparation of new plastered surfaces and applying two coats of Oil bound distemper including over a coat of 1 mm thick wall care putty on wall surfaces complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or un-plastered surfaces and two coat of cement base paint including over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-charge.
M&L for Hard core of gauge not exc 63 mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface with broken stone or boulders complete all as specified and directed by Engineer-in-charge.
M&L for Sand filling under floors or in foundations including watering and consolidation as per specification and complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/hard standing & finished the surface even & fair complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in flooring complete all as specified and directed by Engineer-in-charge.
M&L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including screed bed or bedding layer of 20mm thick in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Sand stone slabs 50mm in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. not exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
S&F GI tubing (ISI) marked) medium grade with all fitting and fixed complete to wall/ceiling or laid in floors of following sized :-
15 mm bore
20 mm bore
S&F bib tap 15 mm dia cast copper alongwith crutch or butterfly handle screwed down CP fancy type 15 mm dia fixed complete all as specified and directed by Engineer-in-charge.
S&F stop valve 15 mm bore CP fancy type screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union and fixed complete all as specified and directed by Engineer-in-charge.
S & F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors fixed to walls complete all as specified and directed by Engineer-in-charge.
S & F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-charge.
S & F 450 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified and directed by Engineer-in-charge.
S&F sinks without drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-charge.
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed by Engineer-in-charge.
S & F Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms) complete all as specified and directed by Engineer-in-charge.
S&F wash hand basin vitereous china flat back size 550 x 400 mm white including CP waste coupling waste pipe brackets complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
S&F framed work, trusses, trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats J'hook Clips etc Fe 410W (Gde-E 250 quality B) complete all as specified and directed by Engineer-in-charge.
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws fixed with L & J hooks and washers, in roofs, walls etc with grade of zink coating 275 complete all as specified and directed by Engineer-in-charge.
M&L for preparing the steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for Powder coated Aluminium anodised frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-charge
M&L for Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-charge
S&F Powder coated anodised aluminium door shutters,aluminium section wt 0.55 kg/m including necessary jointing cleats ,glazing clips rubber neoprane packing ,handles 2 Nos in each door hinges, anodised aluminium snap beading screws etc complete all as specified and directed by Engineer-in-charge
S&F 100mm brass 4 Levers mortice lock vertical type complete all as specified and directed by Engineer-in-charge.
S&F Aluminium (Die cast) body door closer hydraulically regulated, desigantion No. 3, universal type, Suitable for door shutters of 851 to 1000mm in width and weight between 61to 80Kg complete all as specified and directed by Engineer-in-charge
M&L for 5.5mm thick sheet glass, ordinary quality and glazing in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-charge
M&L for Pressed steel frames of size 165X 60mm and 1.25 mm thick for doors with double or single rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed by Engineer-in-charge
M&L for 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panels of timber flate on both sides, with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces the size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressed treated complete all as specified and directed by Engineer-in-charge.
M&L for factory made 35mm thick 2nd class HW glazed and skelton shutter and open rebated and prepared to receive glass, gauge etc (without sash bars), edges or framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.24 (a) supplied and fixed to chowkats complete all as specified and directed by Engineer-in-charge
M&L for for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-charge
M&L for two coats of synthetic enamel paint over coat of pink primer on newly wooden surfaces of any description not otherwise described over 10 Cm width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
S&F for aluminium anodised handle 100mm long fabricated type complete all as specified and directed.
S&F butt hinge size 100mm extruded aluminium alloy with galvanised mild steel hinges pin,anodised and fixed type complete all as specified and directed by Engineer-in-charge.
Excavating in post holes in soft/ disintegrated rock (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as speficied and directed by Engineer-in-Charge.
M & L for PCC (1:2:4) type B-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as speficied and directed by Engineer-in-Charge.
M&L for Rolled sections Fe-410- W(Gde- E-250) quality- B as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as speficied and directed by Engineer-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out soft/disintegrated rock complete all as speficied and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as speficied and directed by Engineer-in-Charge.
M&L for 50mm thick PCC 1:3:6 type C-1 as in plinth protection finished fair and even without using extra cement n exc 2m in length and joints filled with bitumen mastic (1:1) complete all as speficied and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/conduit, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets , light fitting etc removing materials for taking credit and making good disturbed surface of walls,floors etc complete all as specified and directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge.
Taking out carefully copper/GI earthing complete including GI pipe with Cu/GI strip and removing materials for taking credit and making good disturbed surface complete all as speficied and directed by Engineer-in-Charge.
M&L for point wiring pvc insulated unsheathed FRLS 1100 volts grade cable as per IS 694 with valid CML No with multistranded copper conductor cable of nominal cls area 1.5 sq mm each for phase ,neutral and earth drawn and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for conduits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc as earth continuity conductor connected to common earth complete all as speficied and directed by Engineer-in-Charge for the following:- Note : Modular switch and socket shall be measured and paid separately.
All as per Item No 56.00 here-in-before but One light point, controlled by one way switch 5 Amps
All as per Item No 56.00 here-in-before but Oneceiling exhaust fan point, controlled by one way switch 5 Amps
All as per Item No 56.00 here-in-before but one socket out let 3 pin 5/6 Amps on the same board.
All as per item No 56.00 here on before but with copper conductor cable of nominal cross area 2.50 sq mm for phase, neutral & earth for One 2/3 pin socket outlet 5 Amps on independent board.
All as per item No 56.00 here on before but with copper conductor cable of nominal cross area 4.0 sq mm for phase, neutral & earth for power socket point 15/16 A .
S&F of Switch modular 6 Amps single pole, one way 1 module complete all as specified and directed by Engineer-in-charge.
S&F of modular Socket outlet, multi purpose, 6 Amps 3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S&F of modular Socket 15/16 Amps, 6 pin combined 3 module complete all as specified and directed by Engineer-in-charge.
S&F step type modular fan regulator 120W, 2 module ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F of ceiling rose, PVC of size 65 mm x 18 mm two to three terminals (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer including MCCB 160A 25 KA ,415 V complete all as specified and directed by Engineer-in-charge.
S&F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 63 To 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole and neutral (SPN) 40 to 63 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole SP 10-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
M&L for for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sqmm (FRLS) including PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sqmm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engineer-in-charge. NOTE : Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length.
S&F in repair single pole and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED building security light fitting 35 Watt (or above) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S&F in repair of GI pipe bracket medium grade of 40 mm dia for building security light, 1.2 meter in length with clamps made of FI 40 mm x 6 mm Including nuts, bolts & washers, painting complete all as specified and directed by Engineer-in-charge.
S&F surface and wall mounted LED tube light along with fixture, 4 ft, 20W, extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 V ,50HZ , AC supply and operating tempureture 0 to 50 C ,power factor >0.9 ,lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified and directed by Engineer-in-charge.
S& F in repair of LED tube light fitting 10 watt tube LED Neutral worm in colour, 600 mm in length wall mounted LED batten, extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver, optic diffused type including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified and directed by Engineer-in-charge.
Taking down ceiling fan / Exhaust fan/Wall fan/Air circulator fan of any sweep sealing cable ends dismanting blade and removing fan and blade to store complete all as specified and directed by Engineer-in-charge.
M&L for Painting of ceiling fan / Exhaust fan/Wall fan/Air circulator fan of any sweep complete in situ as per existing colour with synthetic enamel paint by spraying including filling cavity with filler one coat after cleaning all dust etc complete all as specified and directed by Engineer-in-charge.
Fixing of ceiling fan / Exhaust fan/Wall fan/Air circulator fan of any sweep after rewinding/servicing greasing change of bearing if reqd ,including making serviceable and noise free in all respect and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-charge. Note :- Rate Quated by Contractor shall be inclusive for replacing all unsv item like quater pin ,nut bolt with check nut ,rubber real etc
M&L for in repairs bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-charge.
GEMRARAMCONTRACTOR
MARUDHARA CONSTRUCTION COMPANY
M/s Ramniwas Bishnoi
S K TRADER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .