Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.6 LAccepted-AOC INSIDE KL PARK W NO 37 IN MOGA CITY | 1 | Accepted-AOC Ok |
Tender Value
₹19.9 L
EMD Value
₹39,820
Closing Date
25 Nov 2019, 1:15 pmClosed
Executive Engineer
Near red cross office Sangrur
Providing and Installing new deep Tw size 250mm id strainght upto 250 mtr. BGL with reverse rotary rig against failed tubewell. Providing and installing new pumping machinery Construction of Gravel pit Rising main150 mm id C.I delivery main 150 mm id
2019_WSS_40527_1
WSSD/Sangrur/29
Open Tender
Drilling Works
Item Rate
60 days
Sangrur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
TIA
₹39,820
20 Feb 2020
18 Nov 2019
26 Nov 2019
18 Nov 2019
25 Nov 2019
18 Nov 2019
Amount
TUBEWELL
Drilling a bore hole 26”i/d (650mm) including collecting of soil sample at each change of strata. Drilling of 26” i/d bore hole will be carried out 250 mtr upto full depth the rates for which stands included in the drilling rates .Drilling of 26” bore with reverse rotary Rig.
from 0 to 150 mtr. BGL
from 150 to 250 mtr. BGL
Note: Erection and dimantling of boring plant including all Arrangements for the transportation of boring Equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost .All rates should be quoted for supplying the material at site of work .Pits for collection of water and water for drilling T/Wells be arranged by the firm / contractor at site at his own cost
In case the bore is converted into a T/Wells payement of bore shall be made upto to the bail plug plus margin (7% or main bore drilling or as actual as per field requirement whichever is less ) required for sustaining the main bore . The test bore beyond margin shall be paid at the rare of of trail bore drilling.
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. (e) 250mm nominal diameter (weight 52.30 kg per meter) 8.0 mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest suitable grade S.S welding electrode to lower the strainer into tubewell bore. (f) 250 mm internal diameter (slot size 0.75/1.0mm) 7.30 mm thickness
Supplying, fixing and lowering of Stainless Steel Socket as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect (c)250 mm internal diameter
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect. (d) 250 mm internal diameter
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Drilling trial bore using telescopic method with suitable rig to extract water samples of different strata’s encountered during drilling to check water quality with respect to Physical & Chemical Analysis, Heavy Metals & Uranium etc. The payment for testing water sample will be paid extra as per the quoted rates against relevant items of this bid. However the rates includes analysis of sand of all strata from where the water sample have been collected. (It should be ensure that the water sample is collected by an officer of rank not less than SDE)
Collection of water sample and testing of sample from approved laboratory (Phisical & chemical Analysis)
Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect (b) 250 mm internal diameter
Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect. (b) 250mm internal diameter (weight 52.30 kg per meter) 8.00 mm thickness
Supplying & fixing of M.S. Clamp of size 250mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. (b) Capacity of Air compressor 550 cfm at 150 PSI
Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from dust, dirt or the vegetable manner as per IS 4097/1967 with latest amendments ((to be paid as per acual length of pipe)
Testing for Uranium in water. From Approved Labortary
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. Complete in all respect
PUMPING MACHINERY
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 887.51 LPM against a head of 89 mtr 30 BHP along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including M.S. Column Pipe of suitable size 100mm=53 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable 10.00 mm2 = 120 mtr. (reputed make) complete in all respects as per standard Specifications.
Credit of old machinery (LS) (Only Submersible Set)
Construction of Gravel Pit outside the Pump Chamber (0.90m dia.) as per standard design & drawings of public health department.
RISING MAIN (Tubewell to OHSR & bye pass)
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. K-7 Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted including excavation back filling complete including all cartage. (150mm D.I K-7)
C.I.FITTING OUTSIDE PUMP CHAMBER
Providing & Installing 150 mm dia delivery main (from Tubewell to duck foot bend including cost of C.I D/F Pipes, D/F Sluice Valves, D/F NRV & Specials as C.I. Bends , Tail Piece, Tees etc. outside the Pump Chamber as per standard design complete in all respects as per Annexure A12-2 & Drawings D-12 & D-17.
CHLORINATOR
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering Syatem, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressurSe upto 7 kg.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .