| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 0 MAIN ROAD MAIN ROAD MILAK RAMPUR UTTAR PRADESH 244901 | RAMPUR | UTTAR PRADESH | 244901 | Accepted-Technical All documents completed |
| 2 | Accepted-Technical | Accepted-Technical All documents completed |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
29 May 2026, 5:00 pmClosed
DDEM MANDI PARISHAD GHAZIABAD
DDEM MANDI PARISHAD GHAZIABAD
SI Commissioning Testing of 02 No 16 M Galvanized LED High Mast Light SF of 25 Nos LED Light Cabling SF of ABC Bunch Conductor Pole Painting etc works at NMY Dibai
2026_RKUMP_1135545_3
3145 Dibai
Open Tender
Electrical Works
Percentage
180 days
dibai
SI Commissioning Testing of 02 No 16 M Galvanized LED High Mast Light SF of 25 Nos LED Light Cabling SF of ABC Bunch Conductor Pole Painting etc works at NMY Dibai
2 documents required · 2 mandatory
₹3,100
DDEM MANDI PARISHAD GHAZIABAD
₹1.7 L
Yes
30 May 2026
23 May 2026
30 May 2026
23 May 2026
29 May 2026
23 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing of 16M high mast pole of approved makewith rising system hot dip galvanised inside & out sidehaving pole sheet thickness 4mm top dia minimum 150 mm, bottom dia minimum 360 mm, base plate 32mm thick, suitable for wind velocity as per IS 875part 3 and having no cercumferential weld with aaccessories for high mast such as head frame suitable for 6 to 12 luminaries and its control gear boxes, 1.5HP Power tool motor, 3 point suspension with steel wire rope 6mm dia double drum winch including making suitable foundation as per manufacture drawing and site requirment along with foundation bolts, nuts, washers, anchor plates etc complete in all respect as per direction and satisfaction to the engineer incharge. | 2 | No. | 2,47,130 | ₹4,94,260 |
| 2 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable
and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). DSR 2025 8.17.5 200 watt | 16 | Nos. | 4,156 | ₹66,496 |
| 3 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angleas per IESNA type I/II/III as per the width of the road
and the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver & electricalcircuitary) of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (Asper ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption shouldnot more than the specified rating and Fixture shallbe of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). DSR 2025 8.14.16 120 watt | 25 | Each | 3,070 | ₹76,750 |
| 4 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. | 4 | No. | 4,498 | ₹17,992 |
| 5 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 20 | MTR | 216 | ₹4,320 |
| 6 | Supply and fixing of 25 Amp. TPN of automatic street light cubicle control panel painted with anty corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case TPN, complete in all respect. | 2 | No. | 26,500 | ₹53,000 |
| 7 | Supply and fixing of single unit LED aviation obstruction light complete with transfarmer and LED spiral etc,complete in all respect. | 2 | No. | 3,945 | ₹7,890 |
| 8 | Supply and laying of aluminium conductor PVC insulated armoured served, sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick stand alround and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Inchange, complete in all respect. The armoring of the cable shall be properly connected with the earthy conductor by clamps etc. 6 sq. mm. 2 core cable. 20c.1.1 | 850 | Mtr. | 157 | ₹1,33,450 |
| 9 | Supply and laying of aluminium conductor PVC insulated armoured served, sheathed cable 1100 volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick stand alround and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Inchange, complete in all respect. The armoring of the cable shall be properly connected with the earthy conductor by clamps etc. 16 sq. mm. 4 core cable. | 660 | Mtr. | 254 | ₹1,67,640 |
| 10 | Supply and fixing of brass nickel plated compression gland for PVC insulated and armored served sheathed under ground cable i/c rubber ring etc. Complete in all respects. The armoring of the cable shall be properly connected with the earth as per direction of E/ I. 16 Sq mm 4 Core | 4 | Nos. | 87 | ₹348 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.44 MB
BOQ_2157776.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .