| 1 | L1₹12.9 LAccepted-AOC D NO 1 71 48 NANDAGOKULA MSEZ COLONY ROAD NO 20 KODIKERE KULAI DAKSHINA KANNADA KARNATAKA 575019 | DAKSHINA KANNADA | KARNATAKA | 575019 | ₹12.9 L | L1 | Accepted-AOC Accepted by CA since the bidder is L1 |
| 2 | L2₹14.0 L+₹1.1 L (8.73%)Rejected-AOC NO 1 57 CLIFFTHI COTTAGE NEAR KALLODI BAJPE MANGALURU 574 142 | DAKSHINA KANNADA | KARNATAKA | 574142 | ₹14.0 L+₹1.1 L (8.73%) | L2 | Rejected-AOC L2 |
| 3 | L3₹15.3 L+₹2.4 L (18.9%)Rejected-AOC SEETHA NILAYA MADYA SURATHKAL | DAKSHINA KANNADA | KARNATAKA | 574107 | ₹15.3 L+₹2.4 L (18.9%) | L3 | Rejected-AOC L3 |
| 4 | L4₹15.4 L+₹2.6 L (19.9%)Rejected-AOC 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | ₹15.4 L+₹2.6 L (19.9%) | L4 | Rejected-AOC L4 |
| 5 | L5₹17.2 L+₹4.4 L (33.9%)Rejected-AOC 128 BOMMASANDRA INDUTSRIAL AREA JIGANI LINK ROAD NEAR TIMES OF INDIA BANGALORE KARNATAKA 560099 | BENGALURU URBAN | KARNATAKA | 560099 | ₹17.2 L+₹4.4 L (33.9%) | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | Raaj power solutions and facilities L1 | ANU ELECTRICALS L5 | B R ENGINEERS L7 | M/s Anugraha power services L4 | DSOUZA ELECTRICALS L2 | SHRI SOMALINGESHWARA ELECTRICALS L6 | SUDHIR ELECTRICALS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Street light pole: Fabricating, supplying and erection of 6 m - Top 70 mm and Bottom 130 mm dia... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm, top. mm with 3 mm thick, suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. | 54 | Number | 9,000 ₹4,86,000 Lowest | 9,999 ₹5,39,946 | 11,856 ₹6,40,224 | 9,500 ₹5,13,000 | 9,000 ₹4,86,000 Lowest | 10,030 ₹5,41,620 | 9,800 ₹5,29,200 |
| 2.00 | Single Arm Bracket: Supplying, and fixing of Single Arm Bracket with 1000 mm Standard 40/50 mm dia Hot dip Galvanized M.S. Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. | 54 | Number | 1,150 ₹62,100 | 1,800 ₹97,200 | 1,123 ₹60,642 | 1,200 ₹64,800 | 900 ₹48,600 Lowest | 1,445 ₹78,030 | 1,300 ₹70,200 |
| 3.00 | Supplying of 4 Core 16 Sqmm, , 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. Make: Finolex / Havells / Polycab / Glostar | 0.88 | Kilo meter | 1,20,000 ₹1,05,600 | 155 ₹136 Lowest | 1,43,520 ₹1,26,298 | 1,25,000 ₹1,10,000 | 1,20,000 ₹1,05,600 | 1,41,842 ₹1,24,821 | 1,18,800 ₹1,04,544 |
| 4.00 | Earth work excavation In all kinds of soils. Depth upto 1.50m for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredto complete the work. | 263.7 | CMT | 200 ₹52,740 Lowest | 300 ₹79,110 | 773 ₹2,03,840 | 350 ₹92,295 | 250 ₹65,925 | 280 ₹73,836 | 200 ₹52,740 Lowest |
| 5.00 | Providing and installing at site of work P.V.C. pipes 6 Kg/m2: 63mm including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc.complete. | 850 | meter | 40 ₹34,000 Lowest | 120 ₹1,02,000 | 187 ₹1,58,950 | 70 ₹59,500 | 90 ₹76,500 | 190 ₹1,61,500 | 110 ₹93,500 |
| 6.00 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff, In existing Trench(2.5 to 25 sqmm) | 0.88 | Kilo meter | - | 11 ₹10 Lowest | 24,960 ₹21,965 | 10,000 ₹8,800 | 20,000 ₹17,600 | 12,000 ₹10,560 | 18,000 ₹15,840 |
| 7.00 | Supplying & fixing miniature circuit breakers of 10 Amp DP on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, Make: ABB / Legrand / L&T / Havells | 15 | Number | 350 ₹5,250 | 300 ₹4,500 Lowest | 1,060 ₹15,900 | 425 ₹6,375 | 500 ₹7,500 | 590 ₹8,850 | 739 ₹11,085 |
| 8.00 | Supply and installation /fixing/ provision of pole Box 260 mm x 210 mm x 116 mm with HRC fuse/MCB provision and suitable connector/terminal for 3 phase / 1 phase connections with Loop in & Loop out terminals for 10 Sq. mm / Sq. mm C Al/Ar/Cu/Ar Cable, enclosed I a Thermoplastic, Polystyrene enclosure, which should be shock proof safe IP65, Dust Proof, water proof having Internally embedded gasket with provision for cable Entry through IP 65 thermoplastic polyamide glands and grommets. | 10 | Number | 900 ₹9,000 Lowest | 1,000 ₹10,000 | 1,872 ₹18,720 | 1,200 ₹12,000 | 900 ₹9,000 Lowest | 1,470 ₹14,700 | 2,000 ₹20,000 |
| 9.00 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such similar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. For street light pole foundation work. | 13.5 | cum | 350 ₹4,725 | 300 ₹4,050 | 811 ₹10,949 | 2,000 ₹27,000 | 400 ₹5,400 | 290 ₹3,915 | 242 ₹3,267 Lowest |
| 10.00 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. For street light pole foundation work. | 0.81 | t | 85,000 ₹68,850 | 85,000 ₹68,850 | 1,31,040 ₹1,06,142 | 75,000 ₹60,750 | 25,000 ₹20,250 Lowest | 70,550 ₹57,146 | 55,000 ₹44,550 |
Tender Value
₹19.3 L
Closing Date
24 Jul 2025, 3:00 pmClosed
Dy Director
Dy. Director, NITK SURATHKAL SRINIVASNAGAR
Providing additional street light poles near rear side of CRF Annex, front side of CCC, Adke circle to Society circle, Mechanical department to WROE department, eastern side of Vikram Sarabhai guest house and Swimming pool road.
2025_NITK_868834_1
Tender No.16/2025-26/HD
Open Tender
Electrical Works
Works
45 days
NITK SURATHKAL SRINIVASNAGAR
As per Tender Doc
9 documents required · 9 mandatory
₹0
Exempted
11 Sept 2025
14 Jul 2025
25 Jul 2025
15 Jul 2025
24 Jul 2025
15 Jul 2025
Amount
Street light pole: Fabricating, supplying and erection of 6 m - Top 70 mm and Bottom 130 mm dia... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm, top. mm with 3 mm thick, suitable base plate and 4Nos of long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.
Single Arm Bracket: Supplying, and fixing of Single Arm Bracket with 1000 mm Standard 40/50 mm dia Hot dip Galvanized M.S. Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.
Supplying of 4 Core 16 Sqmm, , 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. Make: Finolex / Havells / Polycab / Glostar
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff, In existing Trench(2.5 to 25 sqmm)
Supplying & fixing miniature circuit breakers of 10 Amp DP on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898, Make: ABB / Legrand / L&T / Havells
Supply and installation /fixing/ provision of pole Box 260 mm x 210 mm x 116 mm with HRC fuse/MCB provision and suitable connector/terminal for 3 phase / 1 phase connections with Loop in & Loop out terminals for 10 Sq. mm / Sq. mm C Al/Ar/Cu/Ar Cable, enclosed I a Thermoplastic, Polystyrene enclosure, which should be shock proof safe IP65, Dust Proof, water proof having Internally embedded gasket with provision for cable Entry through IP 65 thermoplastic polyamide glands and grommets.
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. For street light pole foundation work.
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including shuttering, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications : M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, pipes for cable entry. For street light pole foundation work.
Wiring for Power Circuit: Wiring for lighting/power circuit using 2 run X 4 sq.mm and 1 run X 2.5 sq.mm PVC insulated 1100V grade multistrand copper conductor single core cable in open or concealed system of wiring. Make: Finolex / Polycab / Havells / Anchor / V-guard / L&T.
Supplying heavy gauge PVC conduit pipe 19/20mm dia and 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700 mm using WF screws.
Supplying and terminating of 16 sqmm tinned Aluminium lugs and crimping and wiring to terminal point for wire of following sizes
Providing and fixing 32mm nominal dia pipes Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
Dismantling of existing 5 to 7mtr long street light pole/RCC pole with foundation, brackets, acsr, insulators and fittings using mechanical/manual means and transporting/stacking it in the place as suggested by the Engineer In charge
Supplying and drawing 3C x 2.5 mm2 Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and(Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990
Supplying & Fixing Chemical earthling Using 6ft. Copper bonded rod with backfill compound for grounding. Conduits, IC cutouts & other equipments back fill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, nontoxic, weather resistance & capable of achieving ohmic value less than one ohm and welding works,CC chamber of 400 x400x400 mm with a cast iron cover and naming of pits, etc( Authorisation certificate should be submitted if needed)
Supply and fixing of LED Streetlight 70W Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>1301m/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 5 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. Note: Comprehensive warranty of 5 years including removing of faulty fittings and refixing of repaired/new fittings using necessary scaffoldings/skylift etc within 5 days from the date of complaint. Failing which necessary deduction will be made in the security deposit amount. Make: Phillips / Bajaj /Havells / Jaguar.
Wiring for lighting/power circuit using 1 run X 4 sq.mm PVC insulated 1100V grade multistrand copper conductor single core cable in open or concealed system of wiring. Make: Finolex / Havels / Anchor / RR cable
Supplying and fixing of 25 mm heavy duty cable glands suitable for UG cable of 1.1 KV class.
DSOUZA ELECTRICALS (BID ID -3253910)
SUDHIR ELECTRICALS (BID ID -3252025)
M/s Anugraha power services (BID ID -3253856)
ANU ELECTRICALS (BID ID -3253338)
SHRI SOMALINGESHWARA ELECTRICALS (BID ID -3254507)
B R ENGINEERS (BID ID -3253846)
Bidder Name
Raaj power solutions and facilities
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .