Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹46.8 L+₹3.8 L (8.79%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹51.6 L+₹8.6 L (19.9%)Rejected-Finance JOGESHWARI W 758 ADARS NEW LINK ROAD 758 ADARS MUMBAI 400101 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400101 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
29 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
SPECIAL REPAIR TO STN HQ BUILDING AND AND OTHER SANCTIONED WORKS UNDER AT AF STN GORKHPUR
2021_MES_473024_1
8824/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹92,000
Yes
21 Oct 2021
4 Sept 2021
30 Sept 2021
4 Sept 2021
29 Sept 2021
17 Sept 2021
60 days
Amount
Dismantling floor, hearth or wall ceramic tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all specified and directed.
M&L for granite (of any type) 18 to 20mm thick machine cut and polished bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over & including 15 mm thick screed bed in CM 1:6 etc complete all as specified as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/ blankets, any thickness, including cover filets complete all as specified and directed.
Dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, in any position complete all as specified and directed.
M&L for non asbestos 4mm thick fiber cement building boards fixed or laid/inserted to aluminium frame work with screws as in false ceiling fixed in ceiling flat or sloping including aluminium anodised snap grid frame work of size 605x605mm for false ceiling with hanging arrangement of 6mm dia G .I. wire (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size and 60mm long and expansion hold fasteners 12.50mm dia 40mm long complete all as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick prelaminated wood grain colour sheet inclusive of solvent cement and fixing at site on frames along walls complete all as specified and as directed.
S&F 5mm thick PVC sheet prelaminated wood grain colour solid PVC sheet in strips and channels fillet of width 35mm for wall paneling including PVC frame complete all as specified and as directed.
M&L for powder coated anodised aluminium doors (sliding/hanging type) with frame size 101.6x44.75x 2.4mm thick and shutter aluminium anodised and lock Rail 44.45x 47.62x2.02mm, style 44.45x47.62x1.95 mm, Top Rail 101.60x 44.45x1.93mm, Intermediate rail 101.50x44.45 x2.01mm and bottom rail 101.60x44.50 x2.5 mm including necessary aluminium fittings like aluminium butt hinges 04 Nos 100mm long, aluminum handles 150 mm long 02 nos, Aluminium tower bolts 200mm long 01 Nos, mortice lock 4 lever MS, hydraulic door closer of suitable capacity 01 No., Aluminium door stopper 01 Nos, jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws etc with paneling in two parts with 12 mm thick prelaminated particle board in lower panel and 5mm thick tinted glass in upper panels incl all fittings & fixture complete all as specified and directed.
M&L for powder coated anodised aluminium partition with frame size 101.6x44.45x1.83mm thick and Intermediate frame size 101.50x44.45x2.01mm including necessary aluminium fittings like jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws etc with paneling in two parts with 12 mm thick prelaminated particle board in lower panel and 5.5mm thick toughened glass in upper panels incl all fittings & fixture complete all as specified and directed.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame n.exc 1.50 Sqm each and removing from site complete all as specified and directed.
All as per Item No. 10 above but exc 1.50 Sqm and n.exc 4 sqm each.
S&F factory made solid PVC Chowkhat /Door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm thick rigid PVC foam sheet coloured, reinforced with 19x19mm MS square tube of 19 gauge including rubber gasket, PVC fasteners, screws, brackets as per SSR Part –II (2010) complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rails on either side & as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing as mentioned in SSR-2020.
S&F 75mm size butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as directed.
S&F Aluminium anodized pressed handle, fabricated type of size 150mm, complete all as specified.
S&F 200mm long Aluminium anodized barrel tower bolt, complete all as specified.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
Taking down cement or cement lime plaster any description incl racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering on brick wall or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering ceiling in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of wall, pilasters, cornices etc and applying two coat of exterior emulsion paint in camouflage pattern (two or more colour combination) over one coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old painted surface of wall and applying one coat of exterior emulsion paint in camouflage pattern (two or more colour combination) complete all as specified and directed.
Demolition of cement concrete un-reinforced in ground floors and paving not exc 15 cm thickness below or above ground level complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed.
S&F 3 mm thick 38 mm wide glass dividing strips complete all as specified and directed.
Taking up or down steel tubing and connections 15mm bore including cleaning for refixing or removing from site complete all as directed.
S&F 15mm bore steel water tubes "medium grade" galvanized with all fittings such as bends, elbows tee etc and fixed to walls and ceiling in floor complete all as directed.
S&F non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm and n.exc. 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in cement mortar 1:6 etc complete all as specified and directed.
S&F Glazed ceramic coloured tiles in vertical surface 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
S&F in repair vitreous china urinal half stall size 590x390mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F in repairs bib taps 15 mm bore brass, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15 mm dia brass angle cock fancy type, with capstan head chromium plated screwed down high pressure with or without lettered with long screwed shank and fly nut screwed complete all as specified and directed.
S&F in repairs 15mm bore pillar tap fancy type cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shanks screwed for iron pipe or union complete all as specified and as directed.
S&F in repairs stop valves 15mm bore cast copper alloy, chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union. complete all as specified and as directed.
S&F in repairs sheet glass shelf assembly consisting of 5.50mm thick glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450 complete all as specified and directed.
S&F in repair vitreous china wash hand basin white flat back size 550x400 mm including two Nos bracket, CP waste coupling and 32mm dia waste pipe complete all as directed.
S&F in repairs brass chromium plated tubular towel rail 20mm dia 600 mm long, fixed complete all as specified and as directed.
S&F in repair soap dish CP any size complete all as specified and directed.
S&F in repair toilet paper holder chromium plated of L&K, Jaquar or Parryware make fixed to wall with CP brass screws complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) with any type of 'P' or 'S' trap excluding flushing cistern and flush pipe, including fixing of water closet complete with plastic water closet seat black/white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair PVC 10 Ltrs valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved complete all specified and directed.
M&L for powder coated anodised aluminium (sliding / hanging type) windows / ventilator with three track bottom track size 92x29.5x2mm thick, side & top track frame size 92x29.5x2mm thick and shutter aluminium anodised 39x20x 2mm thick including necessary aluminium fittings like jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws etc with 5mm thick tinted / plain glass in panels including all fittings & fixture complete all as specified and directed.
M&L for powder coated anodised aluminium grill weight n. exc 5.60 Kg per sqm with all fittings & fixture and including stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified & directed.
Taking down of rain water pipes, of any dia and pattern complete all as specified and directed.
S&F 110mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate surface finished fair and even as in floor complete all as specified and directed.
M&L for preparation new surface of ceiling and applying two coat of plastic emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying two coats of plastic emulsion paint over a coat of primer after filling the interstices of plastered surfaces with Birla/JK wall care putty to get a smooth finish complete all as specified and directed.
M&L for complete removal of existing treatment by washing, rubbing down and stopping old surfaces of wall including scrapping and applying plastic emulsion paint over a coat of primer after filling the interstices of plastered surfaces with Birla/JK wall care putty to get a smooth finish complete all as specified and directed.
Dismantling brick or brick tiles laid bedded and pointed in any type of mortar as on roof etc complete all as specified and directed.
Dismantling / striping out of existing roof treatment (tar felt & roof plaster etc) including PCC padding of any description, and any thickness including backing, and remove the debris complete all as specified and directed.
Roughening surfaces of old concrete floor by sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified & directed.
M&L for cutting out cracks of roof in V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding to maintain proper slope mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag, complete all as specified and directed. Note:-WPC will be measured & paid separately)
M&L for 10 mm thick rendering on fair faces of brick work or on concrete surface in CM 1:3 finished surface even and smooth without using extra cement mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for providing roof treatment as per latest zonal specification specified:- (a) Applying a coat of bitumen primer @ 0.25 ltrs/sqmts and allow to dry. (b) Applying one coat of hot blown bitumen grade 85/25 @ 1.20 Kg/sqmts. (c) Applying APP modified polymeric membrane of weight not less than 3.0Kg/Sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions.
S&F 40 mm thick brick tiles jointed and pointed in CM 1:3 mixed with linseed oil @ 5% by weight of cement. over Screed bed 15 mm thick in CM 1:4 as bedding layer using 100% coarse sand complete all as specified and directed.
All as per Item No. 63 above but except brick tile.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in roof kerb or mud stops, rounded or chamfered on edges surface finished even and smooth without using extra cement, mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified and directed. Make:- Dr Fixit Pidiproof LW+ or equivalent in specified make.
M&L for FORBO or equivalent 2.00mm thick approved permanently conductive ESD tiles of size 615mmx 615mm as per EN 649. The tiles are manufactured form PVC with embedded conductive veins throughout the entire thickness of the tile as per manufacturers specifications. The tiles should offer guarantee on ling life conductivity independently from humidity and temperature. Tiles should be highly compressed with a compact surface. These conductive tiles should be completely free from volatile antistatic chemicals and ensures a permanent and stable conductive performance of the floor over its entire life time. For clean room application tiles should satisfy the strictest requirements for particle release behavior, helping to reduce any threat of contamination certified by Fraunhofer IPA institute of Germany. The compact, pore free surface should be unfriendly to bacteria and moulds to maintain highest standards of hygiene. The abrasion resistance for the tiles is Group M as per EN 660-2. The tiles should have no effect of caster chair continuous use. The seams between the tiles shall be hot welded using the same base material of tiles so that a true material cohesion between the tiles can be produced. The welding/seaming shall be done using hot air welding machine. The Electrical Resistance offered by he tiles is as per IEC 61340-4-1, EN 1081 (100v)ANSI/ESD 7.1. Tiles are inclusive of copper tape and conductive adhesive, which has to be laid before the tiles are laid. The flooring should be resistant against non-oxidizing organic and mineral acids in any concentration (except sulphuric acid). For electro conductive (EC)-5 x 10^4 Ohm <=R<=10^6Ohm For static Dissipative (SD) 10^6Ohm<+R<+R<+10^8Ohm The laying of the tiles has to be done using conductive adhesive and copper tape. Thickness as per EN 428: 2.0mm Tile size as per EN 427:615 x 615mm Slip Resistance as per DIN 51130: R9 Indentation Residual as per EN 433:0.035mm Method of Installation: Conductive tiles to be installed over existing cemtitous self levelling compound flooring self levelling compound.
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out etc in soft / loose soil complete all as specified and directed.
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick PCC type D-2 1:4:8 using 40 mm graded aggregate as in sub base of floor complete all as specified and directed.
S&F 60mm thick reflective rubber moulded interlocking precast PCC paver, tiles M-35 grade, factory made, of any tint, conforming to IS-15658-2006 over & including 30mm sand cushioning & filling the joints with coarse sand complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, benching etc/surface channel drain with necessary form work complete all as specified and directed.
Removing surplus excavated material exc. 250mtrs but not exc 500 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for concealed point wiring for one light/fan point controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. Note:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
All as per item No. 75 above but for one 5 Amps socket point controlled by one 5 Amps switch on same board.
All as per item No. 75 above but for one 5 Amps socket point controlled by one 5 Amps switch on independent board.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note:-(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 15 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type 240 volt complete all as specified and directed.
S&F socket outlet, flush type, 2 in 1, 3 pin 5 & 15 Amps, 230 Volts, multipurpose complete all as specified.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
Taking down old unserviceable light fittings conventional type from wall surface /ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F 10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:-Havells Cat part No. ENDURA LINE ARNE OBS 10W LED865SPCWH or equivalent in Bajaj/ Philips/ CG/ WIPRO
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS20WLED865S PCWH or equivalent in Bajaj / CG.
S&F recess mounting LED luminaire of size 2'x2' white 34/35/36 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR34W LED840S or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:- Havells Cat No. ENDURA CITYLITEPLAT PLUSSL35W LED 757SASYBOPC or equivalent in Bajaj/ Philips/ CG/ WIPRO
S&F exhaust fan single phase 230/240 volt AC 450mm sweep, with painted louvers, metal body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc if required for fixing fan and making good to match the existing surface and making connection with twisted copper flexible wire 23/0.0076mm complete all as specified and directed. Make: Havells/Bajaj/CG.
Taking down old unserviceable MCB DB/ Main Switches, complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F P-17 tempra plug and socket DBs with provision of FP RCCBs 32 A complete all as specified and as directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
Taking down old unserviceable MCCB/ MCBs/ Isolators, complete all as specified and as directed.
S&F MCCB, 4 pole, 63 Amps, 25 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TP, 25 to 63 Amps, 'C' curve, 10 KA breaking capacity, 415 volts complete all as specified and directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing capping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
M&L for concealed sub main wiring with 4 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable (FRLS) and 2 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 4 No 6.0 sqmm conductor cable, 2 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
M&L for earthing with Galvanised iron earth plate electrode 600x600 mm and 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top of earth plate not less than 1.5 mtr below GL connected to GI earth lead wire of size 4 mm dia connected to earth plate electrode by means of GI nuts, bolts and washers of galvanised iron or steel protected with and including 15 mm dia med grade ISI marked GI pipe upto a length of 7.5 mtr long as shown in electrical plate No 5 of MES Sch Part-I with and including PCC 1:3:6, C-1 pit with cover or RCC 1:2:4 B1 reinforced with welded steel wire fabric not less than 4 kg per Sqm watering arrangement within 20mm dia GI med grade pipe ISI marked, GI funnel with GI mesh, filling with mixture of common salt and charcoal necessary excavation and earth work in soft/loose soil including connected to earthing test point, and main switch/DB, testing and commissioning complete all as specified and directed. Note: (i) GI earth wire with GI pipe protection upto 7.5 mtr shall be deemed included in the item.
M&L in replacement copper electrode chemical earthing with high conductive, corrosion resistant, CPRI Tested and CE Certified Maintenance free chemical earthing pit (pipe in pipe technology Based) in which primary conductor (Pipe) having 40 MM dia and secondary conductor having 80 MM dia. The primary conductor is inserted into secondary conductor and between secondary and primary conductor of earthing electrode crystalline compound is to be injected. The length of this electrodes is min 3000 MM (3 meters) having 45 Kg of ground enhancement compound. It contain a homogenous mixture of conductive cement, electrolyte carbon, Hydrous alluminium silicate and other electrolyte compound complete and 60 Kg contain a homogenous mixture of conductive cement, Coal powder, electrolyte carbon, Hydrous alluminium silicate and other electrolyte compound. Filled in earth pit of bore hole of 200 to 250 MM dia and depth upto 6.15 meters min length of electrode will be increase with connecting of 32 x 6 mm copper strip extra up to 3.5 meters, and total depth of earthing electrodes in min 6.15 meters for achieve resistance valve less than or equal to 1.0 Ohm including RCC earthing pit cover having 450 x 450 CI chamber cover all as directed. Note: (a) If less than 1.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and no extra payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 mtr from electrode shall deemed to be included in the quoted rate).
M&L for earthing complete with Copper plate 600x600x3.15mm thick electrode & 20x3 mm copper strip as earthing lead buried directly in ground (earth pit not less than 3.0 mtr deep below ground level) with top edged of the plate not less than 2.40 mtr below normal ground level, connected to copper earth lead by means of bolt, nut, check nut and washer of copper strip of size 20X3.15mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated and testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggregate, funnel, 20mm dia GI med grade water pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not exceeding 50m, complete testing on completion all complete as shown in electrical plate No. 4 of SSR part No1 all as directed. Note: (a) If less than 2.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and no extra payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 mtr from electrode shall deemed to be included in the quoted rate).
Supplying, fixing, testing, installing and commissioning of on line UPS system of capacity 3 KVA , three phase, input 440 Volts, 50 Hz, pure sine wave with resolution of 1% , inverter technology PWM ( IGBT) , transient response + 5% for 100% load variation, correction time 10 Milli second, inverter efficiency should be ≥ 92% complete with battery bank of suitable capacity , maintenance free sealed batteries suitable for 30 Minute battery backup complete with the following specifications, Make Aplab/APC :- (i) Input voltage 440 V AC, 50 hz, three phase (ii) Input frequency 50-hz + 3 Hz (iii) Output voltage 440±10% volts (iv) Output frequency 50 Hz + 0.5 Hz free running, optional + 0.05% & 50 Hz + 3 Hz Sync Mode (v) Regulation + 1 %( typical) (vi) Waveform Pure sine wave, THD less than 2 % ( linear Load) (vii)Short term over cycles load 110% for 30 Sec, 150% for 10 seconds, 200% for 5 seconds (viii) Efficiency peak of inverter more than 92% , AC to AC more than 85% ( Linear Load) (ix) Load power factor 0.8 to Unity (x) Changeover transfer time ( in Sync mode) less than 5 Mili sec
Supplying, installing, commissioning and testing of air curtain unit for prevention of dust and conditioned air losses, single phase, 220 Volts, 50 Hz, made out of MS /CRSA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS/CRCA 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles, etc complete with fittings and accessories so as to produced 1-1.5 m/sec air velocity at floor level for door opening of size 46"x90" complete all as specified and directed .
Supply and install and testing split type air conditioner of capacity 2.0 Ton, 5 star rating inverter type for working on 230 volt, SP, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface with existing surface and providing water pipe upto ground level complete all as specified and directed. Make : Carrier/Voltas/Bluestar/Hitachi/LG
S&F automatic voltage stabilizer for low and high voltage correction equipped with electronic transistorized relay suitable for operation single phase, AC, 50 HZ complete with Voltmeter, indicators and designed for input voltage 130 to 300 stabilized between 215 V to 220 V of capacity 5KVA (not less than 17 amp) complete all as specified and directed. Make : BLUE BIRD/Microtek /V Guard/ Logicstate
S&F chemical portable dehumidifier continuous operating, complete with heater, ducting, electrical connection for 100 CFM capacity complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth strip 32x6 mm, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt all-round earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 6 mm dia MS bars both ways complete all as specified & directed. Note:(a) If less than 5.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and no extra payment shall be claimed by the contractor to this effect. (b) Earth continuity conductor of length upto 7.50 mtr from electrode shall deemed to be included in the quoted rate.
S&F aluminium strip of size 25x3.15 mm complete with saddle, porcelain insulator and fixing screws, washer/ accessories for roof and down conductor complete all as specified and directed.
S&F air termination, single pointed copper rod 12mm dia and 300mm long fixed/ tightened properly at directed location/ height complete all as specified and directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3Nos, 8mm dia 25mm long hexagonal head screw complete all as specified and directed.
S&F earth continuity conductor or main earthing lead 32mmx6mm GI strip/earth lead, laid in trench, fixed on walls or any other position including jointing by tinned GI nuts, bolts and washers in addition to brazing at every joint, complete all as specified and directed.
M&L for work station in straight shape of size 2100x 750x 800mm and size of shelves and drawer 700x350mm and 500 x 300mm. All shelves and drawers and drawers should be open able by pulling also there should be a place to be provided in every work station for passing required electrical wiring complete all as specified and directed. Make:- Godrej/Methodex or equivalent of specified make.
M&L for work station in L shape 750x750x800mm and size 500x300mm. All shelves and drawers and drawers should be open able by pulling also there should be a place to be provided in every work station for passing required electrical wiring complete all as specified and directed. Make:- Godrej/Methodex or equivalent of specified make.
sri krishna construction
DEEP ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .