Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹16.8 L+₹85,874 (5.38%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹17.2 L+₹1.3 L (7.87%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹17.5 L+₹1.6 L (9.87%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹21.7 L+₹5.7 L (35.9%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹44,200
Closing Date
24 Nov 2022, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
SPL REPAIR TO BLDG NO P-102 OF JCO MD ACCN PROVN OF THREE PHASE CONNECTION FROM ESH NO 305 TO LAB NO 02 PROVN OF WIRING FOR INSTALLATION OF FANS IN 34 GD POST A3 TO A4 AT MIL STN UNCHIBASSI UNDER GE SOUTH PATHANKOT
2022_MES_559908_1
GES/PKT/T-44/2022-23
Open Tender
Construction Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹44,200
Yes
21 Feb 2023
26 Oct 2022
26 Nov 2022
26 Oct 2022
24 Nov 2022
10 Nov 2022
Amount
Demolition of brick work/ stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.
M&L for Brick work with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified.
Brick work with sub class ‘B’ bricks, straight or curved on plan any radius in half brick thick wall with old size bricks built in cement mortar 1:4 complete all as specified.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15mm thick in CM 1:4 using liquid water proofing compound on brick work or concrete surfaces on wall, surfaces finished even and smooth using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under respective item).
M&L for Rendering 10 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 10 mm thick in cement and sand mortar 1:3 using liquid water proofing compound on brick work or concrete surfaces of wall/ floor in sunken portion, surfaces finished even and smooth using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under respective item)
M&L for Rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling/Top and sides of chajjas/facia of roof projection incl necessary formwork including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Supply only Polymer liquid water proofing compound.
M&L for Preparation of newly plastered/ prepared surfaces of walls and applying three coats of white wash complete all as specified and directed.
All as per Srl Item No. 10 above, but on ceiling
M&L for Preparation of newly plastered/ prepared surfaces of walls and applying two coats of Oil Bound Distemper over a coat of primer to match the shade as per existing colour scheme/pattern complete all as specified and directed.
M&L for Preparation of newly plastered/ prepared surfaces of walls and applying two coats of cement base paint over a coat of primer to match the shade as per existing colour scheme/pattern complete all as specified and directed.
M&L for Preparation of newly plastered/ prepared surfaces of walls and applying two coats of Exterior Acrylic Emulsion paint over a coat of primer to match the shade as per existing colour scheme/ pattern complete all as specified and directed.
Preparation of existing surfaces incl washing, rubbing down and stopping of painted surfaces of walls and applying two coats of white wash complete all as specified.
All as per Srl Item No. 15 above, but on ceiling
M&L for Preparation of existing surfaces incl washing, rubbing down and stopping of distempered and painted surface of walls and applying two coats of Oil Bound Distemper to match the shade as per existing colour scheme/pattern complete all as specified and directed.
M&L for Preparation of existing surfaces incl washing, rubbing down and stopping of painted surface of walls and applying two coats of cement base paint to match the shade as per existing colour scheme/pattern complete all as specified and directed.
M&L for Preparation of existing surfaces incl washing, rubbing down and stopping of painted surface of walls and applying two coats of Exterior Acrylic Emulsion paint to match the shade as per existing colour scheme/pattern complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. (reinforcement cut as required to facilitate demolition)
Filling of sunken floor with PCC 1:5:10 using 40mm graded crushed stone aggregate including breaking and removal of existing filling of lime concrete/PCC/brick bats and rubbish out off the premises, etc complete all as specified and directed.
M & L for Two Coats of Hot bitumen on newly plastered surface of sunken portion complete all as specified and directed.
S & F for Steel water tubing light grade 40mm dia, galvanised, including short lengths, fixed as spout as in walls of sunken portion of toilets complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8, type D-2 (using 40mm graded stone aggregates) as in sub base for pavement, path etc, complete all as specified and directed.
M & L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified.
M & L for 25 mm thick PCC 1:2:4 type B-0, using 12.50 mm graded stone aggregate, including finishing surface of concrete topping even and rough complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified.
S&F for Non skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified.
S&F for Glazed coloured ceramic tile 450 x 300 x 7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified.
M&L for Non skid Ceramic joint free tiles 7 to 8 mm thick coloured/wooden finish (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified.
M&L for Non skid Ceramic joint free tiles 7 to 8 mm thick coloured/wooden finish (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified..
M&L for Machine pressed precast concrete interlocking paver block built with grey cement and pigment of 60mm thickness, any shape and size confirming to IS incl 50mm thick sand filling under paver, properly levelled etc complete all as specified and directed.
Dismantling of Bricks (laid flat or on edge) or brick tiles in floors, etc. (each layer) laid, bedded and pointed in any mortar complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brusing neat cement slurry with 3.00kg per sqm all as spd & directed.
M&L for Rendering 10 mm thick in CM 1:3 on flat roof surface mixed with liquid water proofing admixture as per manufacturer instructions when concrete surface is green, finished even and smooth without using extra cement all as specified. (Note :- WPC shall be measured and paid separetly).
APP modified roof treatment over existing non-accessible RCC roof slab/chajjah/canopy/parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc including dismantling existing water proofing treatment of any description complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufacture by the same agency as that of APP with adensity of 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non-woven polyster fiber of weight not less than 160 gsm/sqm using butane torch by torch application with 10 cm side laps and 15 cm end lap. Laying of membrane , physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/sqm. (iii) Softening point of membrane not less than 150 degree celcius. (iv) Joint tensile strength - longitudinal not less than 650 sqcm and transverse not less than 450 sqcm at 230 degree celcius. (v) Tear strength- Longitudinal not less than 300 N and transverse not less than 250 N. (vi) Elongation and reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 kg/sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cms end lap.
M & L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate on roof slab including finishing the top surface even & smooth without using extra cement complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each and removing from site complete all as specified and directed.
All as per Srl item No. 39 above, but area exceeding 1.5 sqm and not exceeding 4.00 sqm each, complete all as specified and directed.
S & F for Pressed steel frames of size 105 x 60 mm for doors with one or more rebates incl necessary fixing lugs,hinges, lock strike plate, incl filling of PCC 1:3:6 type C-1 using 12.5mm graded stone aggregate as in frames/hold fast blocks complete all as specified and directed.
S & F for Pressed steel frames of size 125 x 60 mm for doors with one or more rebates incl necessary fixing lugs,hinges, lock strike plate, incl filling of PCC 1:3:6 type C-1 using 12.5mm graded stone aggregate as in frames/hold fast blocks complete all as specified and directed.
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
S & F for Factory made solid panel PVC door shutter 30 mm thick both side prelaminated with wood grain/coloured paint (style) consisting of frame made out of M.S. tubes for top & bottom rails complete all as specified and directed.
S & F for Factory made 35 mm thick, 2nd Class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F for Factory made 35 mm thick, 2nd Class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc, supplied and fitted to chowkats complete all as specified and directed.
S & F for Factory made 20 mm thick Flush shutters, solid core construction and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors, door shutters; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, complete all as specified and directed.
S & F for Z-Section Steel windows/ ventilators with side hung shutters including projecting type hinges with 2 Nos steel handle, 2 Nos Tower Bolt and 01 No steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
All as per Srl Item No 49 above but without glazing bars.
Painting to newly surfaces of wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coat of synthetic enamel paint over a coat of pink primer complete all as specified.
Preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint complete all as specified and directed.
M&L for Painting to old painted surfaces of wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coats of synthetic enamel paint to match the shade as per existing colour scheme/ pattern complete all as specified and directed.
M&L for Preparation of old painted steel surfaces of any description exc 10 cm width or girth and painting with two coats of synthetic enamel paint to match the shade as per existing colour scheme/pattern complete all as specified and directed.
S & F for Butt Hinges, 100 mm long medium weight, complete all as specified.
S & F for 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixedwith hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section complete all as specified.
S & F for 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified.
S & F for Aluminium handles cast type anodised of size 125mm long ISI markedcomplete all as specified & directed.
S & F for continous (Piano) type hinges mild steel bright finish or electrogalvanised with wide of flaps 40mm, complete all as specified & directed.
S & F for 150 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified.
S & F for Floor door stopper of aluminium alloy body, two legged not less than 50mm complete all as specified & directed.
S & F for 40 mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified.
Hasp and staple of size 100 mm, safety type, aluminium anodised with hinge pin incl bolt to hinge plate and fixed with screw complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones glazed with oil putty fixed with beads or in wooden shutters complete all as specified and as directed.
S & F for 03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
S & F for 03 mm thick figured (frosted) glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
Galvanized mild steel wire-cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified.
All as per the description of item No.67 above but fixed in repair.
Disconnecting existing tanks of capacity upto 500 litre, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position.(Cleaning repairing etc measured and paid separately) complete all as specified & directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified & directed.
S & F Rotational moulded polyethlene water storage tanks of capacity 500 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of existing PVC tank of any capacity complete all as specified & directed.
S & F 20mm dia for Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store for 15mm bore complete all as specified and directed.
All as per Item No 73 Above but 20mm bore.
S & F for Steel water tubing medium grade, galvanised, including short lengths, fixed to wall/concealed in wall/ ceiling or laid in floor complete with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc, of 15mm bore complete all as specified and directed.
All as per Item No 75 Above but 20mm bore.
Refixing of old Steel water tubing and connections in new or old position medium grade, galvanised, including short lengths, fixed to wall/concealed in wall/ceiling or laid in floor complete with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc, of 15mm bore complete all as specified and directed.
All as per Item No 77 Above but 20mm bore.
S & F for Vitreous China squatting pan “Orissa pattern” size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with CI ‘P’ trap of long arm of suitable size including connection to flush pipe, anti symphonic pipes etc fixed in repairs, complete all as specified.
S & F for PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 60/90 cm long etc, supplied and fixed in repairs, complete all as specified.
S & F for Vitreous china wash hand basin (flat back or angle back type), size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand incl waste pipe fixed in repairs complete all as specified and directed.
S & F for CP Brass Centre Hole, wash basin Mixture tap, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore complete all as specified and directed.
S & F for CP Brass Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore fixed in repair complete all as specified and directed.
S & F for Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair for 15mm bore complete all as specified and directed.
S & F for Stop valves, cast copper alloy, Chromium plated with long shank and cup (Concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair for 15mm bore complete all as specified and directed.
S&F for Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair for 20mm bore complete all as specified and directed.
S&F for Stainless steel gratings 75mm bore size fixed with cement motar.
S & F for PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed complete all as specified.
S & F for bath cabinet of size not less than 300mmx450mm x75mm deep with standard size of glass complete all as specified and directed.
S & F for Stainless steel towel rail 20mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and directed.
S & F for Soap dish, Stainless steel, approximate size 160x 160x90mm complete all as specified and directed.
S & F for Shower Rose of not less than 100mm dia, stainless steel complete all as specified and directed.
S & F for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats fixed in repair complete all as specified and directed by EIC.
S&F 20 mm bore stainless steel curtain rod with 1 mm thick wall thickness and each length not more than 1.8 Metre including a pair of brackets and knobs with each length/ piece, fixed on doors and windows opening for hanging curtains complete all as specified and directed.
S & F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed in trenches/floors/walls for 75 mm bore of pipe fixed in repair complete all as specified and directed.
All as per Srl Item No 95 Above but 110mm bore of pipe.
S & F for PVC (SWR) floor bend, plain including jointing with solvent cement 75 mm bore in repairs complete all as specified.
All as per Srl Item No 97 Above but 110mm bore of pipe.
S&F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore in repairs complete all as specified.
S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing with cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repair incl waste coupling and waste pipe complete all as specified and directed.
S & F for Stainless steel plate rack of size 900 x 600 mm not less than 1mm thick fixed with bracket, screw and necessary arrangements fixed in repair complete all as specified and directed.
Taking down old damaged pipes of any description from existing lines including necessary excavation of old fitted in trenches, supply , laying and jointing of Reinforced concrete class NP-2, 150 mm dia including testing, haunching against the sides of pipes in PCC ( 1:4:8) type D-2 and returning, filling in disposal of surplus soil to a distance n exc 50m complete all as specified and directed.
Cutting holes in brick walls built in cement mortar or cement lime mortar and making good the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required for exc half brick but n exc one brick thick wall complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over, quality conforming to Grade 415 MPA cut to length bent to shape required including cranking , bending and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Providing cement concrete Type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in landings, Parapet walls, facia, cover slabs upon drainage system incl necessary form work etc, complete all as specified and directed.
Providing Reinforced cement concrete Type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in Slabs supported on walls, landings, balconies, canopies, deck slabs and in shelves and the like incl necessary form work etc, complete all as specified and directed.
Taking down carefully point wiring of any type, size and description from hard/ teak wood batten/through pipes/ casing capping (light, fan, sockets and socket outlets etc) including removal of battens, pipes, plug sockets, socket outlets, switches, shades, ceiling roses, light fittings etc. complete and making good the disturbed surface to match with existing all as directed.
Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/ portion of walls all as directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/ surface conduit/ casing caping complete with its all accessories
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories on surface wiring with top cover of 03 mm thick plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. all as specified for the following :-
One light/ fan point controlled by one, one way switch single pole.
One 3 pin 5 Amps socket point on the same board.
One 3 pin 5 Amps socket point on independent board.
One light point controlled by two, two way switch .
One buzzer/ bell point controlled by one, one way bell push.
All as per item No 110 above but point wiring with 2.5 sqmm cable and 1.5 sqmm earth continuity conductor for 3 pin/ 5 pin 15 Amps socket and all as specified and directed.
All as per item No 110 above but point wiring with 4 sqmm cable and 2.5 sqmm earth continuity conductor for 3 pin / 5 pin 15 Amps socket and all as specified and directed.
S&F switch piano, single pole one way 5 Amps 240 Volt capacity flush type all as specified and directed.
S&F Switch socket combination2 in 1, 5 pin , 5 Amps flush type all as specified and directed.
S&F 3 pin 15Amps switch socket combination flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) all as specified.
S&F in repair ceiling rose of size 65 x 50 mm surface bakelite 240 Volts three terminal as specified and directed.
S&F sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type AC 230 volt suitable for any type of ceiling fan all as specified and directed.
S&F in repair Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
M & L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
S&F for electric bell ding dong type AC 230 volt 50 Hz single phase single pole all as specified and directed.
S&F for LED bulkhead fittings luminaires with opal diffuser including (LED lamp type 10W LED 6000K) lamp holder etc. complete all as required or directed.
S&F inverter type LED fitting 1 x 20W, including LED tube 4' long having bipin holder, connector blosk, driver etc 230 Volts, duly prewired and electrical connections upto ceiling rose using PVC insulated overall sheathed flexible copper conductor cable of size 0.5 Sq mm 03 core complete all as required or directed.
S&F in replacement ceiling fan AC single phase 230/240 volts of size 1200 mm sweep complete type BEE 5 star rated BLDC rated complete with blade set ,down rod, copper wound fan motor , canopy set, shackle kit etc including connecting to ceiling rose with 3 core 0.5 sqmm flexible copper wire all as required or directed . Note: Old retrieved fans shall be deposited to MES store yard by contractor
S&F in repair Ventilation fan AC sinlge phase 230/240 volts of size 225 to 250 mm sweep PVC body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
S&F LED Lamp 230 volts,50 Hz,inverter LED 12/15 watt lumen 900 lm, rated current 0.045A, CRI less than 80, Charging time 8 to 10 Hours, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specififed and direccted.
S&F cornor street light fittings 24 watt LED new generation energy saving and environmental friendly long life verstatile pressure dicast aluminium luminaire with mid power LEDs as light source and exclusively designed polycarbonate cover alogwith electronic driver incl suitable bracket complete with bracket.
Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning of storage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed.
Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of not less than 25 mm size ISI marked including all conduit accessories for concealed to the surfaces of the wall/ ceiling including one run of 6 sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. (NOTE : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.) including making good disturbed surface all as specified and directed.
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 6 Sq mm 2 core. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5 core 150 Sqmm PVC sheathed, armoured, electric power cables (heavy duty) with aluminium conductor of the following size including dismantling old one. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs wherever required.
S&F in replacement existing unsv distribution board iron clad, with double door 4 way with IP-54,1K-09 protection, cemet spill prptector suitable for MCCB as incommer AC 415 Volts three pole with thermal release adjustable type (80% to 100 %) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed. (Outgoing MCB will be measured separately).
S&F sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 8 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position and takingdown old one all as directed.
S&F sheet metal enclosure for MCB DBs, phosphatised, powder coated, Single Pole & Neutral (SPN), suitable for 2 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth bar, in proper position and takingdown old one all as directed.
S&F MCB Single Pole and Neutral (SPN) of capacity 32 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position and taking down old one all as directed.
S&F in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixed in proper position all as directed.
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/ loose soil all as directed.
Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each.
Removal of surplus soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for Sand cushioning/ sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection.
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings/ plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection.
Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5 core 150 to185 sq.mm.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Disconnecting and taking down existing tamper proof electric meter single phase, Re-assembling and refixing to the same /other location alongwith replacement of meter fixing box made out of thermoplastic grey colour with transparent cover, cable entry cover, hinged flap, protection cover including cable entry integrated elastic membrane suitable to accomodated two single phase KWH meter and fixing meter box to flush wall and making connection with proper thimbles, good disturbed surfaces, refixing seals and wires of the fixing the existing meter in meter box complete all as specified and directed. Note : Any damage caused to old serviceable meter while opening/refixing the same shall be make good/replace with new meter by contractor without claiming any extra cost on this account.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
SATISH AND CO
S S CONSTRUCTION
P S BUILDERS
R K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .