Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹47.9 L+₹1.5 L (3.29%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Being not lowest bidder | |
| 3 | L3₹48.4 L+₹2.0 L (4.38%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L3 | Rejected-Finance Being not lowest bidder | |
| 4 | L4₹50.2 L+₹3.8 L (8.11%)Rejected-Finance DINJAN DIST TINSUKIA ASSAM 786 189 E 67 CWE DINJAN | TINSUKIA | ASSAM | 786189 | L4 | Rejected-Finance Being not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Oct 2024, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
PROVN OF TRG SHED WITH HARD STANDING FOR TPS AT TRG GROUND, TOILET CUM BATHROOM BLOCK IN OFFICE COMPLEX, NIGHT PICKET ROOM WITH ATT TOILET NEAR MP CONTROL ROOM, CHEQUERED TILES ON EXISTING PATHWAY IN DINJAN PARK AND CONSTR OF A SMALL ARMS AMN STORE
2024_MES_669911_1
C/8725/E8
Open Tender
Civil Works - Others
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE DINJAN
₹90,000
Yes
30 Oct 2024
2 Sept 2024
12 Oct 2024
2 Sept 2024
5 Oct 2024
18 Sept 2024
Amount
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, cable trench etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
Surface excavation n exc 30cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50 m and making good surfaces in soft/loose soil complete all as specified and as directed.
Material and labour for Hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface with Broken stone or boulders complete all as specified and as directed.
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Cutting chases, pinning in brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concrete water tubing or concrete conduit wiring etc and making good, cutting not exc 10cm girth complete all as specified and as directed.
Cutting existing steel tubing for alterations or additions (Each cut measured) and connection with new PPR pipe 32mm bore including fittings required complete all as specified.
M&L for plain cement concrete (1:3:6) type C-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C1 (20mm graded crushed stone aggregated) as in cills,, hold fast, back filling of pressed steel frame complete all as specified and as directed.
M&L precast reinforced cement concrete, type B1, 1:2:4 (20 mm graded aggregate) as in cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and similar work incl necessary formwork set in cement mortar 1:4 complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) .
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. Note: Steel reinforcement shall be measured & paid separately.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement shall be measured and paid separately under relevant item.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and as directed. Note: Steel reinforcement shall be measured & paid separately.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed. Note: Steel reinforcement shall be measured & paid separately.
Use and waste for Formwork to sides of concrete foundations, footings bases of columns below GL and similar work, rough finished surfaces of concrete complete all as specified and directed.
Use and waste for formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similer works, for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm, complete all as specified and directed.
Use and waste for formwork to faces of sides and soffits of floor or roof beams, cantilevers, lintels, shelves including supports, overhangs, etc for rough finished flat surfaces of concrete complete all as specified and directed
Use and waste for formwork to sides of pillars,columns etc rough finished concrete surfaces complete all as specified and directed.
Use and waste for formwork to to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
S&F 35mm thick second class class hard wood glazed and skelton shutter, open rebated and prepared to receive glass gauze etc, divided into squares (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass exc., size of members of shutter as specified in SSR part-I, sec 8 clause 8.24(a), supplied and fitted to chowkats, complete all as specified and directed.
S&F 35 mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with lock rail and panels of 9mm BWR commercial Ply or 12mm thick veneered particle board medium density, with commercial face veneering on both faces. the size of rail and styles 150 & 100mm, kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing, complete all as specified and directed.
S&F Aluminium anodized barrel tower bolts of extruded section, 200 mm long, complete all as specified and directed.
S&F Mild steel butt hinges, Medium grade, 100 mm size , complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodized, 150 mm size , complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
S&F mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends each screwed end to be filled with washers and one hexagonal or square nut 5 to 10mm dia shank and exc 5cm but n exc 10cm long all as specified and as directed.
S&F for 1.00mm thick plain mild steel black sheet in covering to door, water tank, water trough, hole punched, including round headed screws, clout nails and fixed to wooden or steel frame/members, etc with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends complete all as specified and as directed.
M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
M&L for TMT bars 6 to 8 mm dia , as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
M&L for TMT bars 6 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and conforming to Fe 410-W (Gde-E-250) Quality A complete all as specified and as directed.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed.
S&F pressed steel frames for doors made of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) including 4mm thick sheet glass complete all as specified and as directed.
S&F for aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed. Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd.
S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating (AZ-150) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3.0 Kg of cement per sq. metre complete all as specified and directed
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, as in skirting. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering as backing coat in cement mortar (1:4) , complete all as specified and directed.
M&L for coloured 450x300x7-8 mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick rendering as backing coat in cement mortar (1:4) , complete all as specified and directed.
M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for 100 mm thick plain cement concrete (1:2:4) type B2 using 40 mm graded stone aggregate as in sub-base of floors, plinth protection etc. finished the surface of concrete fair and even, complete all as specified and directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base of flooring complete all as specified and directed.
M&L 100mm thick PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregated) as in sub base of floor complete all as specified and as directed.
M&L for 25 mm thick PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in under layer of tile flooring & finishing the surface rough to receive screed bed, complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 20mm thick in two layers of 10 mm thick each in cement morter (1:4) on fair faces of brick work or concrete surfaces, WPC shall be mixed with morter of top layer, finished even and fair, complete all as specified and directed. Note: WPC shall be measured and paid separately as supply only.
M&L for rendering 5mm thick in cement morter (1:3) on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Supply only liquid Water Proofing Compound of approved make complete all as specified and directed.
M&L for applying three coats of white wash on new wall surface including preparation of surface, complete all as specified and directed.
M&L for applying three coats of white wash on new ceiling surface including preparation of surface, complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement based paint over a coat of cement primer on wall complete all specified and directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of oil bound distemper over a coat of primer over 2mm thick wall care putty complete all as specified and as directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exceeding 0.50sqm in each pane , complete all as specified and directed.
M&L for preparing of new wooden surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Supplying and laying for 16mm bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in wall/ceiling or laid in floor complete all as specified and directed.
Supplying and laying for 20mm bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in wall/ceiling or laid in floor complete all as specified and directed.
S&F in repairs, 15mm cromium plated Bib taps, cast copper alloy with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F for 15 mm bore, Pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F 15mm bore dia Stop cock cast copper fancy type chromium plated alloy screwed down high pressure with crutch or butter fly handle serwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F 15 mm bore angular stop valve cast copper alloy fancy type chromium plated with long shank and cup (conceled type) with capstan head wall flange etc screwed down screwed for iron pipe complete all as specified and directed. .
S&F PTMT grating doom 100mm dia over floor trap complete all as specified and directed.
S&F for swivel shower of PTMT 15mm bore (minimum weight 40 gms) including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum wt 40 gms) complete all as specified and as directed.
S&F for stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed.
S&F vitreous china Semi pedestal pattern (Anglo Indian type) white connection to trap 'P' or 'S' and flush pipe etc seat cover and making good to disturbed surfaces complete all as specified and as directed.
S&F for vitreous china bowl urinal bowl type, of size 465x355x265mm, white (minimum) with grating and union for discharge pipe (excluding flushing cistern but including flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and as directed.
S&F for PVC low level flushing cistern, 10 liter capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC connection pipe and flush pipe of polyethylene of low or high density complete all as specified and as directed.
S&F vitreous china wash basin, size 550x400mm, white, flat back, including 32mm bore PVC (HDPE) waste pipe 450mm long, 32mm bore CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed.
S&F for 450mm long PVC connections 15mm size with PTMT nuts, complete all as specified and directed.
M&L for forming construction (Dummy) joints 10mm wide and 100mm deep and filling with joints sealing compound Gde 'A' complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
S&F PVC (SWR) pipes type 'B' 110mm bore, single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed.
S&F PVC (SWR) pipes type 'B' 75 mm bore, single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed.
S&F PVC (SWR) bends any radius 110mm bore with access door, complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore, complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore, complete all as specified and directed.
S&F PVC (SWR) junction single, (Single T) equal or unequal, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F Brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and as directed.
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
M&L for Plain cement concrete (1:3:6) type C-2 for 150mm pipe, bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, in complete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed cement mortar and tested complete all as specified and as directed.
M&L for forming 12mm thick expansion joints in 100 mm thick concrete slabs, filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, complete all as specified and directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4( 12.5 mm graded aggregate) finished even and smooth. (c) M&L for 15 mm thick screed bed in cement mortar 1:4 finished even and smooth. (d) Preparing & cleaning of fully dried cement plastered surface. (e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (f) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (g) One coat of aluminium paint over APP membrane @0.11Kg/Sqm. Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
M&L for point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid casing caping (medium grade) with all fittings & accessories including provn of MS sunk terminal box of minimum thickness 1.6 mm fixed flush to wall for mounting switch, socket, fan regulator etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per Item No.101 above but for One 2/3 pin socket outlet 5/6Amps on independent board
All as per Item No.101 above but for One 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
M&L for concealed point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
All as per Item No.104 above but for One 2/3 pin socket outlet 5/6Amps on independent board
All as per Item No.104 above but for One 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
All as per Item No.104 above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
M & L for concealed point wiring (flame proof) complete with 1.5 sq mm HFFR, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including stove enamelled steel conduit of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC insulated 1.5 sq mm copper conductor (HFFR) for earth continuity (Green Colour) and connected to common earth dolly and including pressed steel terminal flush boxes made out of 1.6 mm thick MS sheet concealed in wall including sheets for housing switches, socket outlet etc.,all as specified and directed by Engineer-in-Charge for fan/light point controled by one one way 5/6 Amp switch. Note:- (a) Cost of conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. (b) Accessories shall be suitable for flame proof wiring
Supply & fixing switch flame proof rotary type with termination box in LM 6, 16 A , single pole 250 V. complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way switch 5 Amps complete all as specified and directed.
S&F Socket outlet 3 Pin, 5 Amp flush type universal, 240 volts, complete all as specified all as directed.
S&F Switch socket combination 2 in 1, 5 Amps flush type complete all as specified and directed.
S&F Switch socket combination multipurpose 5A/16 Amps, 5 in 1, flush type complete all as specified and directed.
S&F for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
Supply, installing, testing and commissioning of heavy duty Exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 150 W, 220/240 V, 380 mm sweep size, fan speed 1400 RPM, 4 nos. blades, copper winding, and including all fixing accessories including cutting of circular hole at any type of wall suitable size complete all as specified.
S&F MCB distrubution board SPN 4 way double door, sheet steel, phosphatised, powder coated with 200 amps bus-bar, neutral link, earth bar and din rail 240 V , complete all as specified and directed. by Engineer-in-charge.
M&L for clear sand cushioning with dry clean sand for protection of cable, 15cm below the cable and 8cm above the cable, complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Supply and laying well burnt, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
M&L for boring holes 1mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 16 sq.mm 2 core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately. complate all as specified and directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 sq.mm 2 core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately. complate all as specified and directed.
M&L for GI pipe light grade with all fittings complete grouted in ground all as specified for 25 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
M&L for GI pipe light grade with all fittings complete grouted in ground all as specified for 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
S&F LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed..
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings including fixing for one 9 Watt LED Lamp complete all as specified and as directed.
S&F LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F 35/40 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S&F for street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed.
S&F MCB Single pole, 240 volts 6 to 32 Amps 10 KA rupturing capacity, C series complete all as specified and directed.
S&F MCB Single pole and neutral, 40 Amps, 240 volts 10 KA rupturing capacity, C series complete all as specified and directed.
S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
S&F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
M&L for Earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed.
M&L for Earthing with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 420x420x100mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing inclduing taking down old one complete all as specified and as directed.
Supply and fix Galvanised iron strip 32 x 6mm complete with saddles and fixing screws etc. for fitting the strip complete all as specified and as directed.
M/S KAUSHIK ENTERPRISE (BID ID -3129532)
M/S BORAH BROTHERS (BID ID -3129435)
PATKAI ENTERPRISE (BID ID -3129851)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .