Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹12.1 L (10.5%)Admitted-Finance | ₹1.3 Cr+₹12.1 L (10.5%) | L2 | Admitted-Finance |
| 3 | L3₹1.3 Cr+₹14.8 L (12.9%)Admitted-Finance OFFICE NO 206 D WING EXTENSION RAIKER CHEMBER DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 88 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹1.3 Cr+₹14.8 L (12.9%) | L3 | Admitted-Finance |
| 4 | L4₹1.4 Cr+₹26.5 L (23.0%)Admitted-Finance | ₹1.4 Cr+₹26.5 L (23.0%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MARINE AUTOMATION L4 | Arathi Electricals L3 | AEW ELECTRICAL PVT.LTD L2 | GROMOS INDIA L1 |
|---|---|---|---|---|---|---|---|
| 1.00Maintenance of Junction Box of Street Lighting Poles -Routine servicing and maintenance of Street light pole up to cable termination box (J pole /Straight/Garden pole/Tilted GI+GRP Straigh Pole/ Wall mounted pole/ flood light) for LED lighting fixture) as per TSS No. 1.0 | |||||||
| 1.10 | Street Light 'J' poles, Garden Light Poles, Straight Light Poles & Straight Flood Light poles | 876 | Set | 1,150 ₹10,07,400 | 1,490 ₹13,05,240 | 400 ₹3,50,400 Lowest | 1,425 ₹12,48,300 |
| 1.20 | Wall mounted pole & Tiltable Poles | 390 | Set | 1,050 ₹4,09,500 | 1,190 ₹4,64,100 | 400 ₹1,56,000 Lowest | 2,000 ₹7,80,000 |
| 1.30 | Street light 'J' poles with Solar Panels | 25 | Set | 2,300 ₹57,500 | 2,000 ₹50,000 | 1,000 ₹25,000 Lowest | 3,000 ₹75,000 |
| 2.00Maintenance of Street Lighting control DB, Feeder Pillar & Earth Station Routine servicing and maintenance of various, 415V, 3 Phase, control distribution panel & Feeder Pillar as per TSS No. 2.0 | |||||||
| 2.10 | Street lighting control DB | 50 | Set | 2,900 ₹1,45,000 | 2,500 ₹1,25,000 | 250 ₹12,500 Lowest | 2,000 ₹1,00,000 |
| 2.20 | Out door feeder pillar | 30 | Set | 3,800 ₹1,14,000 | 3,500 ₹1,05,000 | 500 ₹15,000 Lowest | 2,200 ₹66,000 |
| 2.30 | Earth Station | 104 | Set | 1,100 ₹1,14,400 | 1,250 ₹1,30,000 | 300 ₹31,200 Lowest | 2,100 ₹2,18,400 |
| 3.00 | Maintenance of Lighting & Power system at Security Watch Towers-Routine servicing and maintenance of Security Watch Towers (SPN DB, DCDB, Power point, Tubelights, Ceiling fan, lighting fixtures, 63 Amp Junction box) as per TSS No. 3.0 | 17 | Set | 5,000 ₹85,000 | 2,500 ₹42,500 | 1,500 ₹25,500 Lowest | 5,000 ₹85,000 |
| 4.00 | Maintenance of High Mast Pole including its DC & AC outdoor control DB as per TSS No. 4.0 | 1 | Set | 15,000 ₹15,000 | 4,500 ₹4,500 Lowest | 5,000 ₹5,000 | 9,500 ₹9,500 |
Tender Value
₹1.2 Cr
EMD Value
₹2.8 L
Closing Date
28 Oct 2024, 6:00 pmClosed
Chief Engineer and Director, Engineering Services
Chief Engineer and Director, Engineering Services Group, BARC, Trombay, Mumbai 400085
Servicing and Maintenance of street lighting system, watch towers and outdoor feeder pillars in BARC, Trombay, Mumbai 85
2024_BARC_828933_1
BARC/TSD/ET/29/2024-2025
Open Tender
Electrical Works
Item Rate
730 days
BARC, Trombay
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹2.8 L
TSD building
26 Dec 2024
4 Oct 2024
1 Nov 2024
4 Oct 2024
28 Oct 2024
4 Oct 2024
4 Oct 2024 - 14 Oct 2024
11 Oct 2024
Amount
Maintenance of Junction Box of Street Lighting Poles -Routine servicing and maintenance of Street light pole up to cable termination box (J pole /Straight/Garden pole/Tilted GI+GRP Straigh Pole/ Wall mounted pole/ flood light) for LED lighting fixture) as per TSS No. 1.0
Street Light 'J' poles, Garden Light Poles, Straight Light Poles & Straight Flood Light poles
Wall mounted pole & Tiltable Poles
Street light 'J' poles with Solar Panels
Maintenance of Street Lighting control DB, Feeder Pillar & Earth Station Routine servicing and maintenance of various, 415V, 3 Phase, control distribution panel & Feeder Pillar as per TSS No. 2.0
Street lighting control DB
Out door feeder pillar
Earth Station
Maintenance of Lighting & Power system at Security Watch Towers-Routine servicing and maintenance of Security Watch Towers (SPN DB, DCDB, Power point, Tubelights, Ceiling fan, lighting fixtures, 63 Amp Junction box) as per TSS No. 3.0
Maintenance of High Mast Pole including its DC & AC outdoor control DB as per TSS No. 4.0
SITC of following sizes of 1.1KV grade Al. XLPE power cables as per TSS No.5.0
Supply of 4 C x 10 Sq.mm. Al conductor cable.
Installation 4 C x 10/16/25 Sq.mm. cable under ground.
Installation 4 C x 10/16/25 Sq.mm. cable in hume pipe/GI pipe/ open air (as per TSS No. 5.4)
Only installation, testing and commissioning of following sizes of 1.1KV grade Al.PVCA/XLPE cables as per TSS No.6.0
3.5 C x 70/95/150/185Sq.mm. cable under ground
4 C x 2.5 Sq.mm Cu cable under ground/in trench
Painting and Stensiling of street lighting poles including foundation of following types of poles as per TSS No. 7.0
J - Type Poles : 7.0 mtr.
Garden Light Poles : 3.0 mtr.
Straight Light Poles : 5.0 mtr.
Straight Poles : 6 mtr. (Flood light)
Wall mounted pole (Trombay Hill)
Painting of street lighting DB's & Outdoor Feeder Pillar of following types as per TSS No. 8.0 .
Street lighting control DB / Outdoor DB/Sub DB - 6 & 4 way
Outdoor feeder pillar
Excavation in following type of soil as per TSS No. 9.0 of specification.
Soft soil
Murrum
Hard rock.
Supply & installation of end termination of following sizes of Al. PVCA cables as per TSS No. 10.0
4 Core x 10/16/25 sq.mm.
3.5 Core x 70/95 sq.mm.
3.5 Core x 185 sq.mm.
Supply, installtion, testing and commissioning of street lighting fixtures complete with all accessories,as per TSS No. 11.0
LED 36W, Street Light
LED 72W, Street Light
LED 50W, Garden Light, Post top
LED flood light 120W
Supply, installtion, termination and connection of following sizes of flexible cables as per TSS No. 12.0
4Cx2.5 sq.mm.
Supply and installtion of Earthing Station as per TSS No. 13.0
Earth Station
Supply and installtion of 25 x 3 mm Cu. Earthing Strip as per TSS No. 14.0
Earthing Copper Strip 25 x 3 mm
Supply and installtion of Weather Proof Junction box as per TSS No. 15.0
Only installtion, termination and connection of 4Cx1.5/2.5 sq.mm sizes of flexible cables as per TSS No. 16.0
Only installtion of FRP Pole junction boxes as per TSS No. 17.0
Street light J pole J.B.
Garden Light J.B.
Removal of existing damaged poles and DB from breaking of concrete and transportation as per TSS No. 18.0
Street light J/Straight Pole.(up to 7.0 Mtr. hight )
Garden light Pole.(approx.4 m ht. x 65 mm dia)
Old Street light control DB/ outdoor DB
Supply and installation of following sizes of G I pipes for installation of street light poles/cable as per TSS No. 19.0
50 mm size
Supply and installation of concret mix(PCC) at the site as per TSS No. 20.0
Supply,fabrication and installation of M.S. items as per TSS No. 21.0
Supply and installation of street light control Distribution Board as per TSS No. 22.0
Supply and installation, testing and commissioning of straight through joints of following sizes of stranded Al. conductor 1.1 KV grade PVCA cables as per TSS No.23.0
4 Core x 10 sq.mm.
4 Core x 16 sq.mm.
4 Core x 25 sq.mm.
3.5/4 core x 70/95sqmm
3.5/4 core x 185sqmm
Only installation, testing and commissioning of straight through joints of following sizes of stranded Al. conductor 1.1 KV grade PVCA cables as per TSS No.24.0
4 Core x 10/16/25 sq.mm.
Only installtion, testing and commissioning of street lighting fixtures on J pole /Straight pole /wall mounted /Garden pole/flood light lighting fixture on complete with all accessories.as per TSS No. 25.0.
Fault finding due to tripping of power supply per TSS No. 26.0
Providing temporary power supply as per TSS No. 27.0
Supply and installation of Low Density Polyethelene film as per TSS No. 28.0
Maintenance of battery powered two wheeler vehical Make Hero Electric, Model Optima Li as per TSS No.29
Supply and installation of spares parts of battery powered two wheeler vehical Make Hero Electric, Model Optima Li for carrying out as per TSS No.30.0
Battery Charger
Break Assembly
LI-Ion Battery 48V/28AH
Supply and installation of following consumable items required for street lighting & Security Watch Tower maintenance work as per TSS No. 31.0
6 Amps. SP MCB
16/20 Amps. SP MCB
Time switch (Astro type)
40 Amp DP RCBO
25/20 Amp DP RCBO
Solar Panel Charge controler
150 AH Battery for solar Panel poles
Supply and installation of Cable Root Marker as per TSS No. 32.0
Deployment and operation of Four wheeler (5 seater) with driver as per TSS No. 33.0
Deployment of above said Vehicle
Operation of above said vehicle
AEW ELECTRICAL PVT.LTD (BID ID -3111701)
Arathi Electricals (BID ID -3107674)
MARINE AUTOMATION (BID ID -3111219)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 0.43 MB
Tender_document.pdf
Tender Documents • 1.37 MB
TECHNICAL_BID_BARC_TSD_ET_29_2024_2025.xls
Tender Documents • 0.28 MB
Man_Power_Recovery_sheet_BARC_TSD_ET_29_2024_2025.pdf
Tender Documents • 0.10 MB
SCHEDULE-A_BARC_TSD_ET_29_2024_2025.pdf
Tender Documents • 0.14 MB
Specifications.pdf
Tender Documents • 2.52 MB
BOQ_871046.xls
BOQ • 0.27 MB
Proforma_of_schedules_BARC_TSD_ET_29_2024_2025.pdf
Tender Documents • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .