| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical GANDIPUR PRANPATTI JAUNPUR | JAUNPUR | JAUNPUR | UTTAR PRADESH | Rejected-Technical document are NOT as per requirement |
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
9 Jan 2023, 5:00 pmClosed
SE,EUDC-VII,Ciss-Gomti,LESA,
33/11 K.V. Substation,sct-5D,Vrandavan Yojna,LESA, Lucknow.
Different type of repairing and maintenence work in the area of various 33/11 KV Sub Stations and lines under jurisdiction of E.E., EUDD., Vrindavan, LESA, Lucknow
2022_MVVNL_758801_1
35/EUDC-VII/LESA/2022-23
Open Tender
Miscellaneous Works
365 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/CNo-1277784945,IFSC Code-CBIN0280140,
₹20,000
12 Jan 2023
15 Dec 2022
10 Jan 2023
15 Dec 2022
9 Jan 2023
15 Dec 2022
Amount
Safe carriage, Loading unloading with proper stacking of following material from ESC-Daliganj to Work site/Je-Dump Store
PCC Pole 8.5/9mtr long
S.T.P. Pole 9/11 Mtr Long
Different maintenance material Cable. Joint Kit, PVC Cable, ACSR wire, Insulators. Transformer oil, ABC cable, fuse Units, Fuse wire, back entry, spring contacts etc.
11 kv HT XLPE cable 3x185 sqmm, 3x120sqmm, 3x300sqmm, etc.
Safe carriage, Loading unloading of meters from EUTD III JE store to Work site/Je-Dump Store
Time to time trimming and chopping of tree branches near 11 KV, 33 KV and LT lines. (All material , labour and T&P will be provided by the contractor)
Fabrication and erection of missing/damaged wiremess fencing 02mtr. Height with gate and retaining wall including grouting of fabricated MS angle 65x65x6 sqmm support and its painting as per specification. (All material , labour and T&P will be provided by the contractor)
Repairing of damaged transformer plinth of size as per requirement at site to maintain the height of 1.5mtr brick bllast, filling of sand in the hollow space, plastening of surface in ratio 1:4:6: and top of plinth 4" thickness concealing. (Including all materials and labour and T&P)
Repairing of damaged/ rusted steel tubular pole by digging of pit up to 2" for proper position putting 3nos. angle from of size 35x35x6 sqmm 3 nos angle around the damaged part of pole and welding properly and also grouting and plastering 300 mm with cement concrets.
Erection of sub-station type Double pole on 9/11 meter long S.T. Pole along with fixing of necessary clamp/accessories required including fixing of straight M.S. 100x50 mm. Top channel 125x65x6mm (2240 mm long) one no. Dropper channel 100x50mm.(2028mmlong )/Angle 100x50 mm 02 nos with arrangement of fixing of 03 nos. Pin insulator including Sub-station base angle of 65x65x6mm (2250mm) channel 02 nos. earthing it properly as per RESPO specification.
Laying of 11 KV 3x185,3x120, 300 Sqmm. XLPE Cable with drilling machine as per norms of UPPCL.
Erection, of single pole PCC/ST Pole 11 Mtr long with all accessories.
Supply and repairing/ replacement of damaged tailless fuse unit/materials/pety on LT distribution piller box with clamping lug of required size of LT PVC. (All material , labour and T&P will be provided by the contractor)
500 Amp. 600 Volts.
300 Amp., 600 Volts.
Resagging of existing LT/HT line opening of ABC on service point and opening of consumers service cable after re-sagging of ABC re-connection of consumers service cable. (In breakdown time man power has been provided 24 Hours.)
Strainthing of tilted Pole of LT & HT line making proper alignment with exiting line. (All material , labour and T&P will be provided by the contractor)
Providing chemical earthing of existing 250/400/630 KVA transformer by boaring & lowering 20" electrode and put chemical for improve earthing resistance below than 1 OHM and connecting of transformer body and neutral with GL Strip.
Arresting oil leackage from transformer by replacement of oil seal, cork sheet and packing of transformer also replacement of bushing rod 250/400/630 KVA transformer along with L-piece. (All material , labour and T&P will be provided by the contractor)
Grouting and nozzelling of stay set complete 16X1800mm.sp. with cement concreat sand, brick, blast.
Re-grouting HT/LT cable and laying of cable during breakdown period/faults on main road etc.
Supply and fixing of Feeders (I/C cable & O/G cable) name plates on double pole and four pole of size 24X24 mm with radium colour along with clamps.