Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹54.7 L
Closing Date
20 Oct 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PHE Division Bijbehara
Executive Engineer PHE Division Bijbehara
Construction of 30000 gallons collection sump for providing drinking water supply facilities to GMC Anantnag main campus at Dialgam incld P/F of rising main, installation, successful testing and commissioning of Mechanical and electrical components (
2021_IFC_142975_1
Enit 27 of 2021-22
Open Tender
Civil Works
Item Rate
30 days
GMC Dailgam
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,200
Executive Engineer PHE Division Bijbehara
Exempted
21 Oct 2021
8 Oct 2021
21 Oct 2021
8 Oct 2021
20 Oct 2021
8 Oct 2021
90 days
Amount
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof
P/Laying of stone soiling dry hand packed
Providing & laying in position cement concrete in 1 Cement :4 Corse sand :8 graded stone aggt.mix of specified grade exculding the cost of centering & shuttering all work upto plinth level.40mm nominal size
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) (In beams, suspended floors)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level hot rolled deformed bars
Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement)
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platforms.
Extra for shuttering incircular work
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platforms.
12mm Cement plaster of mix: 1 : 3 ( 1 cement : 3 fine sand)
12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand)
P/f of MS lid with angle iron frame complete with locking arrangements and applying a priming coat. RTQ
P/F of 100mm dia GI pipe with 10mm thick MS flanges incld cost of nuts bolts washers etc. with all accessories (Light Class) complete incld. Cost of pipes (RTQ)
Filling available excavated earth in trenches plinth sides of foundation etc in layers not exceeding 20cm in depth consolidating each layer by ramming & watering lead upto 50mtrs & lift upto 1.50 meter .
Carraige of material from Different sources to nearest dumping site of work incl loading, unloading & stacking by mechanical transport
Cement/ Steel avg. 10 kms
Sand avg 30 kms
Agg. 20mm Avg. 20 kms
Agg. 40mm Avg. 20 kms
Stone soling Avg 05kms
Earth avg. 10 KM
Supply, Installation Testing & Commissioning of open well Submersible Pumping equipments with following specifications:- (Make KSB/Krilosker/M&P ) Discharge : 8000 GPH Head : 80 Meters Speed : 2890 Rpm Type of pump : Submersible Quality of Water to be handled : Fresh, Cold Water
Supply, Installation Testing & Commissioning of Submersible Pumping equipments with following specifications:- (Make KSB/Krilosker/M&P) • Discharge : 20000 GPH • Head : 25 Meters • Speed : 2890 Rpm • Type of pump : Submersible • Quality of Water to be handled : Fresh, Cold Water
Providing, fitting and Laying of 100 mm diameter G.I. (Class – B) flanged GI pipe for connecting of existing system to collection sump . The pipe line has to be laid underground by trenching and completely embedded to the requisite depth. Make (Prakash Surya/ Jindal/Tata) GI Pipe IS: 1239 (Part 1st). Nominal dia. – 100 mm Wall thickness – 4.5mm Working Pressure 10 kgf/cm sq Flange thickness 18 mm(table 5)
Fabrication, providing and fitting of flanged 90 degree bends made out of GI 100 MM diameter pipe surya prakash includes P/F of nuts , bolts and washers etc for complete job. Fabrication, providing and fitting of flanged Offsets made out of GI 100 MM diameter pipe Surya Prakash as per site requirement includes P/F of nuts , bolts and washers etc for complete job.
Providing & Fitting Control Valves for intake and delivery line. The job includes providing of compatible flanges to the pipes for fitment of valves (Flange standard as per IS: 6392). The gaskets are to be provided between flange connections as per IS: 638-1979. Non Return Valve Size DN 100 Pressure Rating PN 16 Make VAG/AVK/SIGMA FLOW Qty 02 Nos Sluice Valve Size DN 100 Type VAG/AVK/SIGMA FLOW Pressure Rating PN 10 Sealing Soft Sealing Qty 02 Nos
Fabrication ,providing ,fitting ,installation &commissioning of tripod fabricated out of 65 mm dia G.I “B” class pipe of length 12 feet each and 01 ton chain pulley block for lowering/lifting of pumping equipment in sump. Make (Pullift in depth / glow)
Improvement to 100 KVA sub station 11kV / 0.4 kV, by way of providing and fitting of safety devices as under, . Safety Devices G.0 link set Drop out set. Lighting arrestor ISMC 75x40 Channels 9’long -08nos ISMC 75x40 V-cross 51/2’ long 14nos Safe earthing electrode size - 80 mm dia length - 2000mm Backfill - 30 Kg Model / make - JMV-392, Ashlok, Recons Qty 03 No.
Modular Control Panel Providing, Fitting, Installation, testing and commissioning of modular LT Control Panel of appropriate size fabricated out of 16 SWG sheet having required openings / vents and Protection & fitted with accessories as under:- The Panel shall be fabricated out of 02 mm CRCA Sheets Modular, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, name plates, painting etc. generally as per details furnished below: Rated Voltage of the Panel ----- 415 Volts ± 10% Frequency ----- 50 HZ ± 10% No of Phases ----- Three Enclosure Details Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Application ----- Indoor Cable Entry ----- Bottom Painting ----- Shade Siemens grey. a) Distribution bus bar Type -----Electric grade AL with red, blue & yellow tapings of adequate section. Busbar Density ---- 0.8 Amps/MM² Rating ----- 200 Amp( 06-way) b) Change Over Switch Type : On-load Rating : 200A No. Of Poles : 04 Makes : HPL/L&T/ Schneider Qty : 01 c) Circuit Breaker Incomer Type ----- MCCB Qty ----- 1 Nos Make ----- L & T (DN2- 250D) /Schneider /Siemens No. of poles ----- 4 Rated current-----250 Amp(100-250)Amp Operation ----- Extended Rotary Handle Rated operational voltage----- 415 V ± 10% Rated frequency ----- 50 ± 3% Hz Ultimate S.C Breaking cap at (415 V A C , 50 Hz ) --- 36 KA Type of release ----- Thermal Magnetic Release
b) Circuit Breaker Outgoing (Motor Backup Protection) Type ----- MCCB Qty ----- 02Nos Make ----- L & T /Schneider /Siemens No. of poles ----- 3 Rated current-----160 Amp (DN1-160M) Operation ----- Extended Rotary Handle Rated operational voltage----- 415 V ± 15% Rated frequency ----- 50 ± 3% Hz Ultimate S.C Breaking cap at (415V AC 50 Hz ) --- 50 KA c) Auxiliary Feeder:- (MCCB) Rating = 100 Amp Qnty = 01 No. Make = L & T /Schneider /Siemens Type =DN0-100D No of poles = 02 Rated operational voltage =415V ± 10% Rated Frequency = 50± 3% Hz Ambient temperature= 40degree C Ultimate S.C. Breaking Cap. at 415,AC,50 HZ= 36 KA d) Starters MU-G 30 (30-50) Amp Fully automatic Star Delta Starter Make : L&T Qty – 02 Nos e) 05 KVAR Capacitor Bank Capacitor 05 KVAR Phi Cap Heavy Duty – 01 Make : EPCOS /L&T Contactor Capacitor Duty 7.5 KVAR – 01 Make : L&T/Siemens/Schneider MCB TP 16A C Curve --- 01 Make : L&T/Siemens/C&S/Schneider On Delay Timer 0-60Sec – 01 Make : L&T/GIC
Service line :- Providing and fitting of 70 Sq.MM, XPLE insulated, PVC sheathed Armored Aluminum cable 3.5 core from main Electric Sub- Station to the main L.T control Panel in the Pump House. The Cable shall conform to IS: 7098 part- I with latest amendments. The job includes laying and fitting of cable in air /underground as per the site conditions. The job includes crimping of the terminal ends of the cable with hydraulic crimping tool. The conductor shall be of Havells/Finolex make and shall be as per relevant IS specifications/ standards. Qty 30 Mtrs (Make Havels/Polycab/CABE/Finolex) Interconnection cabling :- Providing and fitting of 50 Sq.MM PVC copper conductors, unarmored single core for inter-connection of the equipments like LT panel, voltage stabilizer, starter, motor etc. The job includes laying and fitting of suitable cable tray system in the station for laying/fitting of cable in air or as required as per the site condition with proper clamping etc. The job includes crimping of the terminal ends of the conductor with hydraulic crimping tool. The conductor shall be of Havells/Finolex make and shall be as per relevant IS specifications/standards Qty 50Mtrs @ Submersible cabling :- Supply, Installation, testing & commissioning of 16 sq mm submersible cable of Havells / L& T make to be used from sub pumping unit to control panel etc Qty 1000M
Providing and fitting of Cable Tray of suitable width includes P/f of vertical/ horizontal supports bolts, nuts, cover plates etc required for complete job.
Provided tool kit consist of following items Spanner set = 12 pieces of size 4/5,6/7,8/9,10/11,12/13,14/15,16/17,18/19, 21/23,24/26,24/27,30/32 Ring set = 12 pieces of same size as above Pliers = 2 No`s (tappari) Cutting pliers = 2 No`s (tappari) Screw driver = 2 No`s (tappar) Hammer = 1 no of size 1 kg Pipe wrench = 2 Nos of size 12 inches Mutimeter = 1 No 01 NO. bamboo link rodCost on account of Supply of tools and tackles required for routine maintenance of Electrical and Mechanical equipment. The Job also includes Supplying of bedding & matting to operators quarter. (Make Taparia)
Rubber matting Providing and fitting of 3MM thick high density anti skid rubber floor matting on the machine floor level area including the floor surface area around power control panels and other gadgets. The job includes cleaning of the floor and the under surface of the matting removing dust, dirt, grease and loose sand grains if any .Applying the adhesive of sufficient high bonding strength both on the floor as well as on the under surface of the rubber matting for fixing 50 SFT Shock proof rubber mats:- Providing and laying of shock proof rubber sheets 25 MM thick of size 1 Mtr x2Mtrs as per relevant IS standard .The shock proof rubber sheets shall have to be laid in front of the electric gadgets i.e. LT panel ,stabilizer etc 02 sheets Providing/Mounting of 4.5 Kg carbon dioxide fire extinguishers confirming to IS:2878 02 Nos
m/s ellahie constructions
M/S MOHD ISMAIL TEELI & SONS
Yaseen Constructions
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .