| Sl No | Description | Qty | Unit | ESKIMO COOL WORLD L3 | kiran electrical and hardware centre L1 | Haryana EngineerService L2 |
|---|---|---|---|---|---|---|
| 1.00Material & Labour for replacement of old / Unserveciable compressor with new sealed unit compressor company fabricated with all accessories such as starter, running capacitor & over load wiring of existing makes/model for the water cooler, Deep Freezer & Refrigerator including brazing jointing, leak proof testing & commissioning complete all as specified & directed for the following :- | ||||||
| 2.00 | (a) Compressor suitable for Water cooler capacity 60/120 Litre | 15 | Each | 5,000 ₹75,000 Lowest | 8,300 ₹1,24,500 | 7,500 ₹1,12,500 |
| 3.00 | (b) Compressor suitable for Water cooler capacity 150/150 Litre | 12 | Each | 5,500 ₹66,000 Lowest | 9,300 ₹1,11,600 | 8,500 ₹1,02,000 |
| 4.00 | (c) Compressor suitable for Water cooler capacity 40/80 Litre | 15 | Each | 4,500 ₹67,500 Lowest | 5,300 ₹79,500 | 4,500 ₹67,500 Lowest |
| 5.00 | (d) Compressor suitable for Deep Freezer capacity 320 Litre | 15 | Each | 5,500 ₹82,500 Lowest | 6,300 ₹94,500 | 5,500 ₹82,500 Lowest |
| 6.00 | (e ) Compressor suitable for refrigerator capacity 165 Litre | 12 | Each | 2,150 ₹25,800 Lowest | 3,800 ₹45,600 | 2,900 ₹34,800 |
| 7.00 | (f ) Compressor suitable for refrigerator capacity 280 Litre | 15 | Each | 2,350 ₹35,250 Lowest | 3,800 ₹57,000 | 3,000 ₹45,000 |
| 8.00 | (g ) Compressor suitable for refrigerator capacity 310 Litre | 12 | Each | 2,550 ₹30,600 Lowest | 4,000 ₹48,000 | 3,200 ₹38,400 |
| 9.00Material & Labour for replacement of Old Unserviceable compressor with new sealed unit compressor, company fabricated with all accessories such as starting running capacitor & over load with wiring of existing Make/model for the window AC and Split AC including brazing jointing, leak proof testing & commissioning for the following :- Note : (i) Make of compressor should be same as per make of equipment i.e. AC, Water cooler, Deepfreezer and Refrigerators. | ||||||
| 10.00 | (a) Compressor hermatic type Suitable for 1.0 Ton AC window type | 3 | Each | 7,500 ₹22,500 Lowest | 8,300 ₹24,900 | 7,500 ₹22,500 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINT OF SUMMER COOLING APPLIANCES UNDER GE (WEST) JABALPUR
2025_MES_734759_1
8952/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹98,000
10 Feb 2026
11 Oct 2025
11 Nov 2025
11 Oct 2025
8 Nov 2025
1 Nov 2025
11 Oct 2025 - 27 Oct 2025
Amount
Material & Labour for replacement of old / Unserveciable compressor with new sealed unit compressor company fabricated with all accessories such as starter, running capacitor & over load wiring of existing makes/model for the water cooler, Deep Freezer & Refrigerator including brazing jointing, leak proof testing & commissioning complete all as specified & directed for the following :-
(a) Compressor suitable for Water cooler capacity 60/120 Litre
(b) Compressor suitable for Water cooler capacity 150/150 Litre
(c) Compressor suitable for Water cooler capacity 40/80 Litre
(d) Compressor suitable for Deep Freezer capacity 320 Litre
(e ) Compressor suitable for refrigerator capacity 165 Litre
(f ) Compressor suitable for refrigerator capacity 280 Litre
(g ) Compressor suitable for refrigerator capacity 310 Litre
Material & Labour for replacement of Old Unserviceable compressor with new sealed unit compressor, company fabricated with all accessories such as starting running capacitor & over load with wiring of existing Make/model for the window AC and Split AC including brazing jointing, leak proof testing & commissioning for the following :- Note : (i) Make of compressor should be same as per make of equipment i.e. AC, Water cooler, Deepfreezer and Refrigerators.
(a) Compressor hermatic type Suitable for 1.0 Ton AC window type
(b) Compressor hermatic type Suitable for 1.5 Ton AC window/ Split type
(c) Compressor hermatic type Suitable for 2.0 Ton AC window/ Split type
(d) Compressor rotary screw type Suitable for 1.5 Ton AC window/ Split type
(e) Compressor rotary screw type Suitable for 2.0 Ton AC window/ Split type
(f) Compressor inbuilt invertor type Suitable for 1.5 Ton AC split type
Material & Labour for Rewinding of fan motor of water cooler, desert cooler and AC with super enameled copper winding wire of existing gauge including insulation, warnishing etc, and replacement of worn out bushes, bearings, shafts, nuts, bolts and washers includind greasing, oiling, reassembling and testig the motor complete all as specified and directed for the following capacities:-
(a) 1/7 HP Suitable for Desert cooler
(b) 1/10 HP and 1/35 HP Suitable for water cooler
(c ) 1/4 HP and 1/6 HP Suitable for AC any type
S&F of new PCB (printed circuit board ) units as existing model/make for split AC non invertor 1.5/2 Ton capacity complete all as specified and directed .
S&F of Old/UNSV with new water lifting pump suitable for Desert cooler of 1/20 Hp, 240 volts, 50 Hz, 12 watts, 1.5 mtr head capacity complete all as specified and directed.
S & F PVC switch box including two switch & indicater of Plaza Make for Desert cooler including taking down old switch box complete all as specified and directed
S & F new five speed regulator for Desert cooler 240 volts 50 Hz, single phase, including taking down old switch ,complete any make and any size .
S & F Nobs for window AC , including taking down old switch complete any make and any size, complete all as specified and directed
S & F AC contactor suitable for window AC /split AC 1.5/ 2 TR ,240 volts 50 Hz, single phase including taking down old AC contactor complete all as specified and directed .
S&F in replacement Desert cooler water tank suitable for Desert cooler (as per existing size) made out of 22 gauge GI sheet made to shape including complete all as specified and directed .
S&F in replacement water cooler float valve PVC ISI mark size 15 mm, with ball rod for water cooler any cap/make complete all as specified and directed .
S & F in replacement Suction valve/Liquid valve of size 1/2" & 1/4" along with dead nut complete suitable for split AC cap 1.5/2 Ton out door unit complete all as specified and directed by Engr-in-Charge.
S&F Lamp/bulb Suitable for Refrigerantor of Capacity 310Ltrs/280ltrs/165 ltrs, (thread or pin type),15 volts, 240 volts 50 Hz, single phase including taking down old Lamp complete all as specified and directed .
S&F door switch for refrigerator 240 volts 50 Hz, single phase suitable for existing make of refrigerator including taking down old Lamp complete all as specified and directed .
S & F in replacement GI tubing 15 mm dia medium grade with all fittings such as elbow,tee,union ,socket etc complete all as specified and directed by Engr-in-Charge.
S & F in replacement PVC tubing 15 mm dia heavy duty to fixed on wall/floor with suitable clamps with all PVC fittings such as elbow,tee,union ,socket ISI mark Complete all as specified and directed by Engr-in-Charge.
S&F for Preparation of surfaces and applying two coat of synthetic enamel spray painting on metal surface (inner/outer) of desert coolers of any make and size complete all as specified and directed .
S&F of Old/UNSV with new wood wool pads of required size for Desert cooler any make including complete all as specified and directed .
S&F of Old/damaged with new front Grill made out of 22 gauge GI sheet suitable for Desert cooler any make/size complete all as specified and directed .
S&F of Repair/replacement of damaged body of Desert cooler with 1 mm thick MS sheet any make complete all as specified and directed .
S & F in replacement of old/UNSV fan motor, single phase, 230 volt ,50 Hz ,1/7 HP with blade arm 18" sweep size suitable for Desert cooler, complete all as specified and directed. As per existing size or make.
S & F in Replacement of defective / damaged transformer of voltage stabilizer complete all as specified and directed of following capacity:-
S&F in Replacement of old/UNSV fan motar 230 volt ,50 Hz for following items complete all as specified and directed .
(a) 1/10 HP of Water cooler cap 150/150 ltr
(b) 1/35HP of Water cooler cap 60/120 ltr
(c ) 1/20 HP suitable size of water cooler cap 40/80 ltr
(d ) 1/20 HP for deep freezer cap 310 ltr)
(e ) 1/4 and 1/6 HP suitable for AC window type and split type
S&F in Re-filling of Refrigerent gas Non CFC R 32 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed .
S&F in Re-filling of Refrigerent gas Non CFC R 22 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed .
S&F in Re-filling of Refrigerant gas Non CFC (R-134 A) of Refregirator, water Cooler and Deep Freezer of any capacity including brazing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed .
S&F in Replacememt of Old/UNSV submain wiring with two run of PVC insulated cable of size 4 sqmm copper conductor (Multi strand) drawing into existing surfaces/ concealed conduit including PVC 2.5 sqmm multi strand copper conductor cable as continious earth wire complete and making good distrubed surfaces of wall /floor etc complete all as specified and directed.
Taking down carefully following item of any make/model after repair refixing of same or other position or depositing in MES store of AGE E/M (W) W/S Jabalpur complete all as specified and directed.
(a) Water cooler of any make and size
(b) Desert cooler of any make and size
(c) Window AC/Split AC of any capacity /position
(d) Refrigerator of any capacity /position
(e) Deep Freezer of any make and model
Servicing of summer cooling appliances including pressure testing of AC ,cleannig of indoor unit with blower & outdoor unit of AC washing, filter cleaning,copper tubing check etc, complete all as specified and directed by Engr-in-Charge.
(a) Water cooler of any make and size
(b) Desert cooler of any make and size
(c) Window AC/Split AC
Replacement of Old/UNSV Ply-wood grade BWR type BB 6mm thick (five Ply) cut into required size fixed where required with all fixing are complete all as specified and directed.
Replacement of old/UNSV Running capacitor for AC, Water Cooler, Desert Cooler of following capacity all as specified and directed:-
(a) S&F in repair Capacitor aluminium body 45 Mfd 450 VAC 50 HZ.
(b) S&F in repair Capacitor aluminium body 55+4 Mfd 450 VAC 50 HZ.
(f) S&F in repair Capacitor aluminium body 36 Mfd 450 V AC 50 HZ
(g) S&F in repair Capacitor aluminium body 50 Mfd 450 V AC 50 HZ
(h) S&F in repair Capacitor aluminium body 45 Mfd +6 450 V AC 50 HZ
(k) S&F in repair Capacitor aluminium body 50 Mfd +6 450 V AC 50 HZ
S&F in Replacement new Thermostate for AC, complete all as specified and directed by Engr-in-Charge.
S&F in Replacement of Old/damaged with new Chromium plate flush type Bib cock of 15mm dia for water cooler any type and any make complete all as specified and directed by Engr-in-Charge. .
S&F in replacement of Thermostate for water cooler of any type and any make /capacity complete all as specified and directed by Engr-in-Charge. ..
S&F in replacement of Over load protector for water cooler, as per existing size and make.
S&F in replacement installation and testing copper tubing of size 1/2" &1/4" along with sleeve insulation complete all as specified and directed by Engr-in-Charge. ..
M & L for fabrication of angle iron frame with equal angle of size 40x40x 6 mm suitable out door unit window/split AC 1.5/2 Ton capacity,Desert Cooler stand incl PCC work and fixing arrangement complete all as directed by Engr-in-Charge .
S & F in repairs single pole and neutral encloser with two pin and earth plug and socket complete with one MCB SP 32/20 Amps complete all as directed by Engr-in-Charge .
S & F in repairs MCB SP, 230 volts, 20 to 32 amps as per complete all as directed by Engr-in-Charge .
S & F in repairs MCB SPN, 230 volts, 32 to 40 amps as per complete all as directed by Engr-in-Charge .
S&F in repairs Three core copper flexible wire PVC insulated cable and PVC sheathed of size 2.5 sqmm complete all as specified and directed.
S & F in repairs three pin plug top 15 amps ISI mark complete all as directed by Engr-in-Charge .
S & F in replacement of PVC connection ISI mark 15 mm dia & 60 cm long complete with rubber washer for water cooler complete all as specified and directed.
S & F MS fan blade suitable for follwing sizes including taking out of old unserviceble
S & F in replacement of heavy duty flexible PVC pipe 15 mm bore for desrt cooler complete all as specified and directed.
S & F in repairs air filter suitable for 1.5/2 Ton split AC as per existing size complete all as directed by Engr-in-Charge .
S & F in repairs Nitrile Rubber black insulation cover suitable for copper tubing any of size complete all as directed by Engr-in-Charge .
S&F in Re-filling of Refrigerent gas Non CFC R 410 A of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed .
S&F in Replacement of Old/UNSV PCB with new inbuilt inverter type PCB(printed circuit board ) units as existing model/make for split AC 1.5/2 Ton and Invertor Refrigerator of any capacity complete all as specified and directed .Make As per Existing.
S & F in replacement swing motor of split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: As per existing.
S & F in replacement water tray suitable for split AC 1.5/2 Ton capacity, any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: LG/Voltas/samsung
S & F in replacement condensing Coil of window type/ split type AC cap 1.5/2 Ton any type and any make/model complete all as specified and directed by Engr-in-Charge .
S&F of Blower for indoor unit of capacity 1.5/2 Ton split AC
S&F of Contactor 3 phase 25-32 Amp all as specified and directed.
S & F in replacement cooling coil of window type/split type AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .
S & F in replacement of wiring kit of window type AC of cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .
S & F in replacement of Freezer /Evaporator for refrigerator with freezer door of capacity 165, 280,310 ltrs any make/model complete all as specified and directed by Engr-in-Charge .
S & F in replacement of stainless steel tank of water cooler for all capacity of any make/model all as specified and directed by Engr-in-Charge.
S & F in replacement of condensing coil for refrigerator of capacity 165, 280,310 ltrs any make/model complete all as specified and directed by Engr-in-Charge .
S & F in repairs switch socket combination 15 Amp flush type, 240 Volts, 50 Hz of any make/model complete all as specified and directed by Engr-in-Charge .
S&F Replacement of Old/UNSV PCB with new PCB (printed circuit board ) units as existing model/make for Window type AC 1.5/2 Ton capacity complete all as specified and directed .
S & F in replacement of remote control suitable for split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge.
S & F in replacement of PVC drain pipe of 15mm dia and 0.5mm thick corrugated type complete all as specified and directed.
S & F in replacement of indoor unit of cap 1.5 ton split AC, any type and any make/model complete all as specified and directed by Engr-in-Charge.
S & F in replacement of Out door unit of cap 1.5 ton split AC, any type and any make/model complete all as specified and directed by Engr-in-Charge.
M&L for Shifting of split type AC by taking out AC from MES yard or from existing location to the new location by taking it after taking down, closing the opening of old location with cement mortar,white wash to match with the existing colour of the site & making holes in brick wall at new location and fine finishing with cement mortar white wash etc to match with the existing colour of the site installation & commissioning after replacement of insulation of suction & dischare line,charging,electrical connection only. ( Note:- (i) S&F insulation ,copper tube ,gas and other spare parts will be measured and paid separately under relevant items. (ii) Existing/ new location will be in Technical or Domestic area as per site requirement.)
Supply & filling Nitrogen gas for vaccum for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge.
S&F in repair Flare Nut of any size (upto 1 inch) Make: as per sample
S&F in repair Overload Protector. As per Sample.
M&L LPG butane gas cartridge of capacity 230 gm for soldering.
S&F in repair overload relay for water cooler as per sample
S&F in repair overload relay for Refrigerator as per sample
S&F in repair for Non return valve for charging gas As per sample
S&F in repair Bi-Metal with timer suitable for Double door Refrigerator Make:- As per sample
S&F in repair Strainer two way/single way . make : As per sample
S&F in repair Capacitor aluminium body 6 Mfd ±5% 440 V AC 50 HZ
S&F in repair Capacitor of capacity 10mfd,±5% 220VAC .
S&F in repair Capacitor of capacity 15mfd,±5% 220VAC.
S&F of new PCB (printed circuit board ) units as existing model/make for Invertor Refrigerator of any capacity complete all as specified and directed .
S & F in replacement of fan motor 10w/16w of Refrigerator any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: As per existing.
S&F in repairs four core copper flexible wire, PVC insulated cable and PVC sheathed cable of size 4 sqmm complete all as specified and directed.
Attending of complaints of summer appliances deploying experienced air condition / refrigeration mechanic and helper and rectification of complaints to the entire satisfaction of Engineer-In-Charge and users. Note:-(i) For rectification of complaints if any spares, gas etc required to be replaced the same shall be measured and paid seperately under "supply and fixing" items. (ii) Mechanic engaged by contractor for attending complaints and rectification there of, shall carry the required job card, which shall be supplied by contractor at his own cost. (iii) Sufficient mechanic and staff shall be engaged by contractor in order to rectify the all complaints with in 24 hrs on all working days as well as holidays as given by the dept.If contractor fails to attend/rectify the complaints within 24 hrs he shall be panalised for Rs. 100 Per complaints. Note for Item No.1 to 85:- (i) Being maint contract site will be hand over to contractor as per complaint received from user and as per site requirement. (ii) Contractor trade man should report to AC section daily and take complaints from concern JE E/M and after attending complaint he will give feedback and return complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day.
Haryana EngineerService (BID ID -3470214)
ESKIMO COOL WORLD (BID ID -3470264)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8952GP.pdf
Tender Documents • 0.43 MB
Tender8952PS.pdf
Tender Documents • 1.09 MB
BOQ_822749.xls
BOQ • 0.34 MB
SCH8952.pdf
Additional Documents • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .