Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹34.9 L+₹5.9 L (20.3%)Rejected-Finance HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹59.2 L+₹30.2 L (104.2%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹42.7 L
EMD Value
₹85,460
Closing Date
13 Dec 2021, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN-914134 c/o 56 APO
REPAIR MAINT OF HT DISTR SYSTEM AND ALLIED WKS AT KHREUH, SHERE-E-SHALI AND KHUNMOH UNDER GE 861 EWS
2021_MES_484540_2
134 WE-33/2021-22
Open Tender
Civil Works
Item Rate
240 days
Srinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 861 EWS
₹85,460
Yes
5 Jan 2022
20 Nov 2021
15 Dec 2021
20 Nov 2021
13 Dec 2021
28 Nov 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out soft/loose soil for laying cables/ pipes/erection of poles etc complete all as specified and directed by Engineer-in-charge.
Excavation in trenches exceeding 1.5m wide and n.exc 3 mtr deep and getting out in soft /loose soil for laying of cables complete all as specified and directed by Engineer-in-charge.
Removing surplus material (soil) to a distance not exceeding 50mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point, complete, all as specified and directed by Engr-in-Charge.
Returning, filling in soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Supply and lay in trenches river sand clean including spreading/ leveling cushioning for underground cables all as specified and directed. Note :- Punned depth shall be measured.
Supply and laying in replacement reinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm complete, all as specified and directed by Engr-in-Charge.
M&L Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates) as in foundation of pole etc all specified and directed.
M&L PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete for stay complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including use and waste of form work for coping of pole and stay complete all as specified and directed by Engr-in-charge.
M & L cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
M & L cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-in-Charge.
M & L cable jointing kit for 11/6.6 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
M & L cable jointing kit for 11/6.6 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
M & L cable jointing kit for 11/6.6 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and laying in repair in trenches/ poles/ wall etc HT UG Cable XLPE insulated with multistranded aluminium conductor armoured with galvanised steel wire/ taps 11/6.6 KV grade confirming to IS specifications of 3 core 95 Sqmm including taking down old unserviceable cable all as specified and directed by Engr-in-charge.
Supply installation and erection in vertical position steel tubular swaged poles type 410, SP-55 (11 metres long) with 300mm x300mmx 6mm mild steel base plate continuously welded to pole, MS plate 3 mm thick finial taper plug bolt, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded position and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surfaces and making alternate black and white strips 30 cm high with super enameled paint over a coat of red oxide primer upto 1.5 mtrs height from ground level/ coping after erecting complete incl taking down of old unsv wooden pole all as specified Note : Excavation, PCC for foundation and earth work shall be measured and paid separately
Supply, install, testing and commissioning gang operated air break isolating Switch triple pole mechanically operated with vertical isolated mounting on 09 insulator and steel frame with mechanism worked from ground level and including operating rod 25mm dia medium GI of required length and locking arrangements of capacity 200 Amps 11/6.6 KV with and including drop out fuse set complete including making all incoming/outgoing connections all as directed and painting of steel work with two coats of aluminium paint over a coat of red oxide primer including taking down old and unserviceable switch complete all as specified and directed by Engr-in-Charge.
Supply, erection and fabrication of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed all as specified and directed by Engr-in-Charge.
Supply & erect Anti climbing devices, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately)
Supply, fixing, jointing and connecting Rabbit/ Wolf Aluminium conductor, steel reinforced with and including proper binding wires etc including taking down old unserviceable ACSR all specified and directed complete all as specified and directed by Engr-in-Charge.
S& F in repair lightning arresters gapless metal oxide type with all fittings, suitable for a system voltage of 11 KV and of class 65 KA, complete all as specified and directed by Engr-in-Charge.
S&F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous, enameled white with letters. figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25 x 3mm MS flat, bolts and nuts for HT 25 x 20 cm size complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of expulsion type HT drop out fuse with all accessories and contact insulator etc fixed on HT pole of superior quality of capacity 10-25 Amps suitable for 11/6.6 KV 3 Pole with two Nos insulator per pole complete all as specified and directed by Engr-in-Charge.
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11/6.6 Volts volts grade including taking down old unserviceable insulators all as specified and directed by Engr-in-Charge.
S&F disc type insulator, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11/6.6 KV volts including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
M&L Loop type insulator, vitreous, porcelain, white, brown or green insulator large size, with over all dimensions 90 x 140 mm, clearance of hole 25.5mm including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
S & F in repair of Stay assembly complete with accessories as shown in electrical plate No 1, diameter of stay rod 16mm & MS plate 230mm x 230mm x 6mm thick , complete all as specified and directed by Engr-in-Charge. Note:- Loop type insulator, stay clamps, excavation and concrete work shall be measured and paid separately.
M&L for cradle ground, hexagonal/ rectangular, fabricated with galvanized steel wire of 4mm dia for road crossing etc all as specified and directed.
M&L loop type porcelain viterous white, brown or green large size with overall dimension 90mm x 140mm hole 52.5mm etc all as specified and directed.
Re-stretching of aluminium conductor any size and length complete including removing kinks and providing new binding wire/ jumper where required all as specified and directed by Engr-in-Charge. Note : (i) Span from one pole to next pole will be considered as a one Job. (ii) Any damage cause due to contractor men will be rectified without any extra payment. (iii) T&P such as ladder, rope, cutter, axes and other related material will be provided by the contractor.
Taking down and reinstall transformer step down 11/6.6 KVA 433 Volts complete outdoor/ indoor capacity up to 250 KVA incl transportation to the wksp and back complete all as specified and directed.
All as per Ser item No 31 but 500 KVA
M&L for strip opening of transformer and removing the top cover for inspection draining the transformer oil and taking out the core along with HT/ LT coil (Winding) assembling the core after replacement of HT/LT coils heating varnishing, testing and housing accessories in transformer body and connection up filling in dehydrated new transformer oil and connection with existing electrical system HT/ LT and commissioning compete on load of capacity not exceeding 160 KVA ( Transformer oil will be measured and paid separately).
All as per item No 33 above but above 160 KVA up to 300 KVA
M&L Filtration of transformer oil step down 11/6.6 KV / 0-433 V indoor/outdoor type up to 500 KVA capacity installed at different sub stations/locations using filtration and heating equipment at site by re-circulating transformer oil heating, dehydration and improving di-electric strength of the oil to withstand 40 KV for one minute including testing of oil as specified and directed. NOTE : Transformer oil test kit shall be provided by the contractor at site for testing of oil.
Filling in with new transformer oil low viscosity of approved make as per IS-335 of 1992 and die-electric strength 42 KV when tested at 2.5 mm gap all as specified.
M&L for winding of HT/ LT coil of different type, capacity and make of transformer with approved quality super enameled copper wire/ strips of approved make of suitable gauge and number of turns along with allied materials like cork steel, fiber glass insulations, paper insulations, cotton/ Empire tap and tube wooden blocks bolts, nuts and washer (Brass )soldering and other packing material etc all as required at site or directed by Engr-in-Charge.
M&L for HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity upto 160 KVA complete all as specified and directed by Engr-in-Charge.
All as per item No 38 above but exceeding 160 KVA not exceeding 250 KVA
M&L for LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 160 KVA complete all as specified and directed by Engr-in-Charge.
All as per item No 40 above but exceeding 160 KVA not exceeding 300 KVA
M&L for of Breather assembly of standard size filled with silica gel of transformer up to 300 KVA complete with nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
Supply, fabricating, jointing and connecting with galvanised steel wire 3.15 mm dia cradles hexagonal/rectangular complete all as specified and directed by Engr-in-Charge.
M&L GI tubing light grade galvanised with all fittings for cable protection fixed with poles laid in trenches /fixed to wall etc of nominal bore dia 80 mm, complete all as specified and directed by Engineer-in-Charge.
Supply and laying coarse aggregates of size 20 mm at different places around HT pole structure/ feeder panel upto depth 45cm complete all as specified and directed by Engr-in-Charge.
Supply and spreading fine aggregates (sand) at different places around HT pole structure/Feeder panel upto depth 40 cm complete all as specified and directed by Engr-in-Charge .
Taking down written shut down from concerned JE/ AGE (E/M) for cutting of tree branches touching to the HT over head line or near to the HT over head line as per the direction of AGE E/M/JE in charge complete including removing the tree branches Note : (i) Span from one pole to next pole will be considered as a one Job (ii) Any damage cause due to contractor men will be rectified without any extra payment. (iii) T&P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 600x600x6mm buried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts, check nuts and washers of galvanised iron and 32x6mm GI strip protected by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC 1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for separately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistance is not obtained, the contractor shall redo the earthing without any extra cost to the department.
M&L maint free safe earthing system (set of four electrode to be used as grid for equipment earthing) each pit complete with 01 number UL 467 approved/CPRI tested copper bonded (copper gladded earth rod with 250 microns of copper cladding) earth rod with 17.2mm dia 3000mm long electrode buried in ground to bore holes 120mm dia vertically to a depth not less than 3.50 mtr deep blow ground level or L shape in case of Rocky condition (2 ft deep and 8 ft horizontal) with top edge of earth electrode at a depth not less than 500mm below normal ground level, provision of copper bus bar of size 200mmx25mmx6mm for inter connection with copper earth lead strip 25mm x3mm and further connected to test point terminal block all as directed each earth pit shall include minimum 50 Kg (two bags of 25 Kg each) NABL lab certified back fill compound and 6 Kg (two container of 3Kg Each) NABL Lab certified conductive gel compound for filing bore holes with mother soil mixed in 1:3 ratio (one part of back fill compound and three part of mother soil), so as to achieve earth resistance below 1 Ohm including excavation of poly pit chamber with poly plastic pit cover (cost of ply pit chamber with poly plastic pit cover shall be deemed to be including in the rate quoted) complete all as specified and as directed by Engr in charge. Make Dhruva Technology Pvt Ltd, Pragati, Ashgel Electrode or equivalent. Note: (a) Copper strip beyond test point shall be measured and paid separately. (b) Contractor shall give guarantee of minimum 5 yrs for the earthing carried out by him. (c) The rate of quoted is inclusive of test point made of phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long brass nuts and bolts complete all as directed. (d) Any other fittings/fixtures if technically required for achieving desired results (if not included above) shall be provided by contractor without any extra cost to the Govt (e) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost of department.
M&L for preparation of old painted surfaces, removing dust and other deposited materials by scraping from HT tubular pole of 11 Mtr long and applying one coat of black paint upto 1mtr height from ground level and rest part of the pole applying two coat of aluminium paint, including cross arms bracing, GI pipe, nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge.
M&L for servicing of HT, 11 KV, OCB any capacity 50 Hz, breaking capacity 25/50 KA by drawing out from panel chamber including removing carbon deposits from contact points, greasing and tightening all fixed and moving contacts for smooth functioning including replacement of tripping and closing coils, 30 Volts, DC and servicing of solenoid switch all as specified and directed by Engr-in-charge. Note : Calibration of relays and primary and secondary injection test shall be conducted by Authorised Company/ Manufactures. Certificated of authority shall be produced by the technical Auth. Make : CG/L&T/Siemens/ABB.
Supply and fix/ erect/ ground HT cable route indicator made out of GI plate 3 mm thick and 6 inches dia duly marked with working voltage, size of cable and route indicator fixed with angle iron of size 25x x25x x3mm thick, 50 cm long embedded in PCC 1:2:4 type B1 of size 20 x20x 20 cm in ground all as specified and as directed.
Supply and laying (in replacement) in trenches/ poles/ wall etc HT UG cable XLPE insulated with multistranded aluminium conductor armoured with galvanized steel wire/ taps 11/6.6 KV grade confirming to IS specifications of 3 core 120 Sqmm sizes including taking down old unserviceable HT cable complete all as specified and directed Make : Polycab, Havells or equivalent.
Dismantling and taking out steel pole fixed in any position and removal from site and taken in credit all as directed by Engr-in-Charge
Taking down and reinstall transformer step down 11/6.6 KVA 415 Volts complete outdoor/ indoor capacity up to 300 KVA incl transportation to the wksp and back complete all as specified and directed.
M &L make bore to road/ cement path/ hard standing for provision of GI pipe 80mm to 100mm light grade for passing armoured cable incl making good the disturbed surface complete all as specified
M&L material and labour earthing complete with using GI wire 4mm dia as a earth lead and galvanized steel earth plate electrode 60cm x 60 cm x 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate not less 1.5 mtr below normal ground level, filled around with alternate layers of charcoal dust and salt and connected to earth lead wire by means of bolts, nuts, check nuts and washers of galvanized iron or steel and thimble and other ends of the earth wire connected to pole and protected by galvanized iron pipe light grade 15mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC 1:3:6 type C-2 in chambers, RCC 1:2:4 type B-1 in put cover reinforced with 8mm dia deformed bars @ 15cm centre to centre both ways including necessary excavation & earth work as directed by Engineer-in-Charge compete all as shown in electric plate No-03 of MES Sch Part-I of 1991 PCC chamber shall be constructed at least 0.5mtr away from the earth electrode and pipe for watering including taking out old earthing complete all as specified and directed by Engr-in-Charge
M&L (including Engineer/ technician) to calibrate/ servicing the VCB in sub stn of make crompton greaves as exists to trips immediately in case of fault (overload current/ earth fault) and replace its minor parts i.e. HRC fues 2 Amps, indicator lamp control wiring if required as site requirement and make them 100% serviceable throughout the year incl servicing of VCB (indl Engineer/ Technician) indl oililng, greasing, clearing with blower from inner and outer side, decarburizing of the links with CRC spray and checking serviceability of all mechanical parts. The rates for charging of minor parts is deemed to be included in quoted rates.
S&F in replacement TNC switch as per existing as per existing make & specifications suitable for VCB 400 Amps, 11 KV including necessary connection & testing complete all as specified and directed.
S&F in replacement coil assembly as per existing make & specifications suitable for VCB 400 Amps, 11 KV including necessary connection & testing complete all as specified and directed.
S&F in replacement tripping coil assembly as per existing make & specifications suitable for VCB 400 Amps, 11 KV including necessary connection & testing complete all as specified and directed.
S&F replacement indicator bulb 20 watt 1100 watt as per existing make & specification suitable for VCB/ OCB 400 Amps. 11 KV including necessary connection & testing all as specified and directed.
M&L in replacement isolating contact assembly (set of 6 Nos) suitable for VCB 11000 volts, 400 Amps rating, 13.1 KA including necessary connection & testing as per existing make and specification, complete all as specified and directed.
M&L in replacement breaker phase barrier suitable for VCB/ RMU 11000 Volts, 400 Amps rating 13.1 KA including necessary connection and testing as per existing make and specification complete all as specified and directed.
M&L in replacement earthing contact assembly suitable for VCB/ RMU 11000 Volts, 400 Amps rating 13.1 KA indicating necessary connection and testing as per existing make and specification complete all as specified and directed.
M&L in replecement drive link assembly with adjuster (set of three) suitable for VCB/RMU 11000 volts, 400 Amps rating 13.1 KA indicating necessary connection and testing as per existing make and specification complete all as specified and directe.
M&L in replacement motor with gear assembly single phase 230 volts suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA indicating necessary connection and testing as per existing make and specification complete all as specified and directed.
M&L in replacement motor charged mechanism assembly with close/ trip coils & charging handle suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA indicating necessary connection and testing as per existing make and specification complete all as specified and directe.
M&L in replacement of base assembly of existing VCB indicating necessary connection and testing as per existing make and specification complete all as specified and directed.
M&L in replacement contact system for VD4 400 A (12 finger) suitable for VCB/ RMU 11000 volts, 400 Amps rating 13.1 KA indicating necessary connection and testing as per existing make and specification complete all as specified and directed.
S&F in replacement potential transformer of fixed type 3 phase, 3 limbs with HRC fuses mounted, suitable for VCB 11000 Volts, 400 Amps complete all specified and directed Make : ABB/GE/SIEMENS/CG
S&F in replacement digital ammeter with shunt suitable for VCB 11000 volts, 400 Amps complete all as specified and directed.
S&F in replacement digital frequency with shunt suitable for VCB 11000 volts, 400 Amps complete all as specified and directed.
Supply, fixing & testing in replacement numerical type relay for VCB tripping system (3 OC - 01 earth fault and high set instantaneous protection in single unit) suitable for operation on 24 V DC all as per Model No CGI4N of CG or in Areava complete (Note : existing relays are make of CG any modification in the wiring and panel sheet enclosures is deemed to be included in quoted rates.
Supply and fixing in replacement of master relay for VCB tripping system with parelly to 3 OC - 01 earth fault and high set instantaneous protection in single unit suitable for operation on VDC all as per existing model any modification in the wiring and panel sheet enclosure is deemed to be included in quoted rates.
Supply and replacement of epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 200/ 100/ 05 VA for 11KV complete, Make : Vishal/ Crompton/ Concord
Supply and replacement of epoxy resin cast CT dual core of ratio as per existing accuracy class 0.55, burden 100/ 50/ 05VA for 11KV complete, Make : Vishal/ Crompton/ Concord
Supply and fixing maintenance free batteries 12 Volts 180 AH including taking down old unserviceable battery. Make : Amron/ Exide SAP code FXPD-MHD Exide new express.
Supply and replacement of battery charger of 24 V with boost charging and trickle facility and amp and volt meter complete.
Supply and laying in repair in trenches/ poles/ wall etc HT UG Cable XLPE insulated with multistranded aluminium conductor armoured with galvanised steel wire/ taps 11/6.6 KV grade confirming to IS specifications of 3 core 70 Sqmm including taking down old UNSV cable, complete all as specified and directed.
Servicing of HT 11000 volts 4 pole structure by replacing old ACSR conductors jumpers connection conecting PG clamps, conductor, screw, nut bolts, washer applying of petroleum jelly for fixed and moving contact of AB switches including proper alignment and tightening of all connection, complete all as specified and directed.
All as per Ser item No 84 but 2 pole structure.
M&L for rerouting of cable disconnecting removalof cable from wall floor, duck including cable clamps, cable gland etc without damage of cable,complete all as specified and directed.
Repair of road after laying of protection of pipe for cable laying with M&L for 15mm thick (compacted thickness) WBM with coarse aggregate of grading 2 (63 to 40mm size) spread, rolled and consolidated to gradient and chamber required with 8 to 10 ton power rolled (type of aggregate lime stone, sand stone, flint and quartile) complete and M&L premix macadam with paving bitumen binder VG-30 not less than 4% by weight 75mm thickness, M&L for preparing surface by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with gunny bags to removal of all loose dirt etc. and applying evenly a primary/ tack coat with paving bituminous primer @ 5KG/10 Sqm of road surface of providing bituminous premix carpet 40mm thick consolidated thickness with 0.27 Cum of stone chippings and mix with @ 14.6 KG of binder (paving bitumen) and applying liquid seal coat @ 9.8 KG/10 Sqmm binding with 6.3mm size stone chipping @0.09cum/10 Sqm and roll with 8 to 10 ton power roller to uniform smooth surface, complete all as specified and directed.
Supply and fixing drop out fuse 10 to 50 Amp in existing GOD at different locations.
M/s Lal Enterprises
M/S ZAHOOR ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .