Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹26.8 L+₹1.0 L (4.03%)Rejected-Finance | L2 | Rejected-Finance Rejected in AOC |
Tender Value
Refer Docs
EMD Value
₹54,800
Closing Date
26 Oct 2020, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Special repair to Bldg No P-10 ground (1st and 2nd floor single OR living Accn), complete wiring with accessories of A Vehicle garages No P-1 to P-10 and certain sanctioned works under GE (Army) Suratgarh at Suratgarh Mil Stn
2020_MES_383673_1
GE (A) SOG - 44/20-21
Open Tender
Civil Works
Item Rate
210 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹54,800
Yes
4 Dec 2020
5 Oct 2020
28 Oct 2020
5 Oct 2020
26 Oct 2020
12 Oct 2020
Amount
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 1 above but 20 mm dia bore.
M&L for making connection from existing GI water pipe line of size 15mm bore and insertion of GI Tee of size 15x15x15mm including earth work making joints and jointing material etc complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore PTMT bib tap of any colour high pressure, screwed for iron pipe (minimum weight 90 grams) complete all as specified and directed by Engineer-in-charge.
S&F 15 mm bore bib tap, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F 600mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Note : Taking down of serviceable fittings shall be measured and paid separately.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including concealed PVC rigid conduit medium grade 20mm dia with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 9 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 9 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 9 here-in-before but for One light point controlled by Two 2- way switches.
All as per serial item No. 9 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F switch piano flush button 15 Amps single pole, one way complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F switch piano flush button 5 Amps single pole, two way complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F socket outlet 3/5 pin, 15 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand, Havells, Cona, SSK
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge. Make:- Legrand, Havells, Cona, Anchor
S&F in replacement flush mounting factory made SPN DB 4 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in L & T / Havells / Schneider
S&F in replacement flush mounting factory made SPN DB 8 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 20 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408615 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408618 or equivalent in L & T / Havells / Schneider
S&F LED Lamp 12 watts suitable for normal holder complete all as specified and as directed by Engineer-in-charge. Make :- Syska, Philips, Crompton Greaves
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in L & T / Havells / Schneider Make of MCB :- Legrand Cat Part No 408593 or equivalent in L & T / Havells / Schneider
S&F in replacement sheet metal enclosure DB concealed with wall having facility to fix MCCB as incomer and MCBs in outgoing, TP vertical type 04 way of double door, complete fitted with bus bars, neutral links, G frame including 04 pole MCCB 63 Amp capacity 50 Hz, 10 KA breaking capacity GS frame type, blanking plates including making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. Make of DB :- Havells Cat part No DHDLVDRWAOFO04, and MCCB cat part No IHLGSF0063 or equivalent in L&T / Schneider / Legrand
S&F in replacement Energy efficient decorative ultra slim, prewired, linear 36/40 watt LED light fitting batten type with drive & polycarbonate housing with all accessories prewired complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No STOUTPLUS1200BS40W LED840SPCWH / Syska cat part No SSK-ILB-2036-36W / Crompton Cat Part No CIS-305-40-57-HL2-DP-NWH / Wipro / Philips
S&F in replacement Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS18WLED 865SPCWH / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL
S&F in replacement Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865 SPCWH / Syska cat part No SSK-T5T-9W / Crompton cat part No LCTLN-10-CDL / Wipro / Philips
S&F in replacement Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in replacement Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in replacement Sub main wiring complete with 2 single core 2.5Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 20mm dia concealed including single core multi stranded copper conductor 2.5Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 2.5 Sqmm single core cable and one run of 2.5 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one Rm.
S&F in repair street light bracket made out of 40mm dia GI pipe light grade 1.2m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F in replacement LED flood light of 120 watt with high pressure die cast housing with lens with lument output 6000K complete (including LED, drive and internally prewired) with on board 5 KV surge protection with 10 KV external SPD. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 100 lumens per watt and FRLSH cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked for light to ceiling rose complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Syska Cat part No SSK-BLS-N-120W / Wipro cat part No LF20-132-060-57-G2 /Crompton Cat part No LFLN-120-CDL/60-M / Philips
Supply, fixing and testing in replacement LED Street / Security light fitting of 45 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Syska Cat part No. SSK-SLF-F-45W-WL / Crompton Cat Part No LSTV-45-CDL / Havells Cat part No ENDURAPEARL NEOSL45WLED757SASYTOPC / Wipro Cat Part No LR02-501-XXX-57-XX / Philips
All as per Srl item No 39 above but LED street / security light of 30 watt. Make :- Syska Cat part No. SSK-SLG-CF-30W / Crompton Cat Part No LSTS-30-CDL-M / Havells Cat part No ENDURAPEARL SL30WLED757SASYTOPCMP / Wipro Cat Part No LR02-331-XXX-57-XX / Philips Notes for srl Item No 39 & 40 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
S&F water storage heater (geyser) of 25 ltr capacity, energy saving 5 star rating complete with fire retardant cable and 3 pin plug 15/16 Amp, including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge. Make :- Havells Product code GHWASESIB025 (Model SENZO) / Crompton Cat part No ASWH825-IVY (Model Solarium Deluxe) / Racold Model Altro 2 Vertical AN-25
S&F water storage heater (geyser) of 50 ltr capacity, energy saving 5 star rating complete with fire retardant cable and 3 pin plug 15/16 Amp, including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge. Make :- Havells Product code GHWAMESWH050 (Model Monza EC-H) or equivalent in Racold / Crompton
S&F Deep freezer capacity not less than 320 ltr, electric driven single phase 230 volt complete all as specified and as directed by Engineer-in-charge. Make :- Blue star Model No CHF400 A / Carrier / Samsung Model No HF400
Supply installing & testing water cooler of 80 Ltr storage capacity with nominal cooling capacity 40 Ltr per hour, single phase , 230 volts, Five Star Rating with necessary inlet connection with HDPE / Flexible pipe both ends CP brass union for GI Pipe and ball brass valves complete including electric connection through voltage stabilizer complete all as specified and directed by Engineer in charge. Make:- Blue Star Model No SDIx 480 / Usha Model No SS 4080 Note :- Voltage stabilizer shall be measured and paid seperately under respective items of BOQ
S&F Desert cooler of size not less than 66 cm x 66cm x 94cm having capacity not less than 5500 cubic feet per minute, single phase, electric driven, cooler body made out of GI sheet 1.22mm thick 18 gauge fitted with exhaust fan 900rpm including 2" thick wood wool pad, front grill (approximate weight 2.5 Kg) made of GI sheet, one submercible pump, speed retulator of suitable size (600 watt), one piano switch 6 Amp, indicator and 1.50 metre long connection lead 3 core with 5 Amp plug top complete all as specified and as directed by Engineer-in-charge. Make of exhaust fan & submercible pump :- Crompton, Khaitan , Havells Note :- Cooler body shall be internally painted with one coat of black bituminous paint.
S&F heavy duty exhaust fan 450 mm sweep, 1400 RPM, single phase, 230 volts, 50 Hz with IP 55 protection as per IS-2312 1967 with louvers including suitable size MS angle frame for mounting the 380 mm sweep fan and connecting up and including 3 core,1.5 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge. Make :- Havells Model No Terbo Jet SP / Bajaj / Crompton
Supply, installing & testing Voltage Stabilizer of capacity 2 KVA copper wound for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 280V output voltage 230 V with accuracy of + 5% complete all as specified and directed by Engineer in charge. Make :- V Guard / VINTEK ELECTRONICS (VOLINA) / VINITEC ELECTRONIC LABORATORY (VINITEC)
Supply, installing & testing Voltage Stabilizer of capacity 3 KVA copper wound for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 280V output voltage 230 V with accuracy of + 5% complete all as specified and directed by Engineer in charge. Make :- V Guard / VINTEK ELECTRONICS (VOLINA) / VINITEC ELECTRONIC LABORATORY (VINITEC)
Supply install and testing of commercial Air curtain unit complete with air curtain sensor for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening size 46"x78" all as specified and directed by Engineer-in-charge.
M&L for Cutting holes in brick walls built in cement mortar for 450mm exhaust fan and making good dismantled portion complete all as specified and directed by Engineer-in-charge.
Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 25 sq mm 4 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 52 above but cable of cross sectional area 16 sq mm 2 core
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
Taking down existing ceiling fan of any make and size from fan hook, opening / dismantling fan for tightening bolts, nuts, screws, loose connections and re-assembling, greasing, oiling, making fully functional to the entire satisfication of Engineer-in-Charge and hanging in same position including testing for required speed and air displacement and complete all as specified. --------------------------------------------------------------------- Note :- A sum of Rs. 32540/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 23 & 24 (Schedule of Credit) of Tender documents.
K M TILES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .