Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.6 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹65.7 L+₹2.2 L (3.46%)Rejected-Finance 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹66.7 L+₹3.3 L (5.15%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹70.9 L+₹7.4 L (11.7%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹75.6 L+₹12.1 L (19.1%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | D.N.PATIL L4 | R A Electric Co. L3 | SREE HARITHA ASSOCIATES L2 | MC Gandhi and Sons L1 | pk Enterprises L6 | M.K Enterprises L5 | M/s PIONEER CONTRACTORS L7 | K A ELECTRIC CO L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Fix, Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / ducts of following sizes including taking out cable, complete all as specified and directed by Engr-in-Charge :- | - | - | - | - | - | - | - | - | - | - |
| 1.01 | (a) 3.5 core 70 Sqmm | 350 | RM | 490 ₹1,71,500 | 455 ₹1,59,250 | 440 ₹1,54,000 Lowest | 550 ₹1,92,500 | 520 ₹1,82,000 | 510 ₹1,78,500 | 500 ₹1,75,000 | 530 ₹1,85,500 |
| 1.02 | (b) 3.5 core 95 Sqmm | 350 | RM | 560 ₹1,96,000 | 535 ₹1,87,250 Lowest | 550 ₹1,92,500 | 670 ₹2,34,500 | 600 ₹2,10,000 | 610 ₹2,13,500 | 600 ₹2,10,000 | 640 ₹2,24,000 |
| 1.03 | (c) 3.5 core 120 Sqmm | 450 | RM | 710 ₹3,19,500 | 680 ₹3,06,000 Lowest | 680 ₹3,06,000 Lowest | 815 ₹3,66,750 | 760 ₹3,42,000 | 690 ₹3,10,500 | 700 ₹3,15,000 | 790 ₹3,55,500 |
| 1.04 | (d) 3.5 core 150 Sqmm | 300 | RM | 750 ₹2,25,000 | 730 ₹2,19,000 Lowest | 760 ₹2,28,000 | 930 ₹2,79,000 | 790 ₹2,37,000 | 780 ₹2,34,000 | 800 ₹2,40,000 | 850 ₹2,55,000 |
| 1.05 | (e) 3.5 core 185 Sqmm | 200 | RM | 950 ₹1,90,000 | 920 ₹1,84,000 Lowest | 950 ₹1,90,000 | 1,195 ₹2,39,000 | 1,040 ₹2,08,000 | 1,080 ₹2,16,000 | 1,100 ₹2,20,000 | 1,170 ₹2,34,000 |
| 1.06 | (f) 3.5 core 240 Sqmm | 175 | RM | 1,250 ₹2,18,750 | 1,170 ₹2,04,750 Lowest | 1,240 ₹2,17,000 | 1,475 ₹2,58,125 | 1,350 ₹2,36,250 | 1,540 ₹2,69,500 | 1,580 ₹2,76,500 | 1,450 ₹2,53,750 |
| 1.07 | (g) 3.5 core 400 Sqmm | 300 | RM | 1,760 ₹5,28,000 | 1,740 ₹5,22,000 Lowest | 1,910 ₹5,73,000 | 2,150 ₹6,45,000 | 2,100 ₹6,30,000 | 1,920 ₹5,76,000 | 1,840 ₹5,52,000 | 2,300 ₹6,90,000 |
| 2.00 | Excavation in trenches for not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in Hard/dense soil including taking out faulty cable/cable covers and GI pipe, complete all as specified and directed by Engr-in-Charge. | 450 | Cum | 620 ₹2,79,000 | 640 ₹2,88,000 | 560 ₹2,52,000 | 350 ₹1,57,500 Lowest | 575 ₹2,58,750 | 650 ₹2,92,500 | 620 ₹2,79,000 | 600 ₹2,70,000 |
| 3.00 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm, complete all as specified and directed by Engr-in-Charge. | 285 | Cum | 270 ₹76,950 | 310 ₹88,350 | 140 ₹39,900 Lowest | 165 ₹47,025 | 290 ₹82,650 | 360 ₹1,02,600 | 300 ₹85,500 | 350 ₹99,750 |
Tender Value
₹68 L
EMD Value
₹1.3 L
Closing Date
14 Jul 2025, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad, Maharashtra
REPAIR AND REPLACEMENT OF STANDBY DG SETS CABLES ALONG WITH ALLIED ACCESSORIES FOR VARIOUS E/M INSTALLATIONS IN TECH/ NON TECH AREA OF TUNIR AND NAD, NAVY NAGAR, CHUNA BHATI, COMMON AREA ETC AT NAVAL STATION KARANJA
2025_MES_714832_1
84453-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (NW) Karanja
₹1.3 L
18 Sept 2025
16 Jun 2025
16 Jul 2025
16 Jun 2025
14 Jul 2025
7 Jul 2025
Amount
Supply and Fix, Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / ducts of following sizes including taking out cable, complete all as specified and directed by Engr-in-Charge :-
(a) 3.5 core 70 Sqmm
(b) 3.5 core 95 Sqmm
(c) 3.5 core 120 Sqmm
(d) 3.5 core 150 Sqmm
(e) 3.5 core 185 Sqmm
(f) 3.5 core 240 Sqmm
(g) 3.5 core 400 Sqmm
Excavation in trenches for not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in Hard/dense soil including taking out faulty cable/cable covers and GI pipe, complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm, complete all as specified and directed by Engr-in-Charge.
Removing excavated materials not exc 50m and depositing where directed at a level not exc 1.5m above the Starting point, complete all as specified and directed by Engr-in-Charge.
Material and Labour for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers, complete all as specified and directed by Engr-in-Charge.
Supply and laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40mm , complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:3:6 type C2 using (40 mm graded stone aggregate) as in foundation of pole, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC type B-1, 1:2:4 using (20 mm graded stone aggregate) as in coping, including form work, complete all as specified and directed by Engr-in-Charge.
Supply and laying of 110 mm outer dia, double wall corrugated (DWC) duct pipe conforming to IS 16205 (Part 24) with antirodent and non flame propagating properties of approved colour complete with fittings for cable protection, complete all as specified and directed by Engr-in-Charge.
Material and Labour for GI pipe light grade with all fittings complete laid in trenches for 100 mm bore of pipe, complete all as specified and directed by Engr-in-Charge.
Material and Labour for dismantling of existing panel including disconnecting connected cables, etc. and Supply, Install, Testing and Commissioning CPRI approved cubical type LT Panel floor mounted outdoor type for 415V, 3 phase 4 wire system 50 Hz AC supply, factory made fabricated from MS sheet totally enclosed, dust weather proof and vermin proof for outer shell having TPN aluminium bus bar rating 1.5 times that of controlling MCCB supported on SMC insulator with short circuit withstand capacity 5 MVA for 1 second, bottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 2.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half and general construction confirming to IS-8623/93 and mounted on suitable PCC foundation with following detailed specification & control complete with suitable fixing accessories, complete all as specified and directed by Engr-in-Charge. OUTER SHELL :- The outer shell shall be made of 3.15 mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of glands. The dimension of the outer shell shall be adequate to accommodate inner shell described below 50 mm space all around and shall be fabricated in such a way that the complete inner shell alongwith its control gears and accessories should be taken outside without disturbing outer shell. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be provided. The degree of protection of the outer shell shall be IP-65.
INNER SHELL :- Inner shell made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air "U' type gasket shall be used to make the inner shell completely vermin proof and to accommodate incomer/outgoing MCCB's and TPN aluminium bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB's. The TPN bus bar and extension links shall be insulated with colour coded heat, shrinkable sleeve and shall be mounted on suitable size 'F' class through out the length of the TPN bus bar. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be provided on bus bar chamber. All control wires shall be with not less than 2.5 Sqmm multistranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequate size of lugs. The cubical shall have a bottom channel of size 75x50mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availability at the incomer. The degree of protection for inner shell shall be IP-42 and carry the following control :- (A) INCOMING - (i) MCCB of 400 A, microprocessor based ,4 pole 415 volt 36 kA breaking cap. conforming to IS/IEC-60947-2 including spreader terminal kit -01 Nos (B) OUTGOING - (i) MCCB of 250 A, microprocessor based ,4 pole 415 volt 36 kA breaking cap. conforming to IS/IEC-60947-2 including spreader terminal kit -03 Nos(2 W + 1 spare ) (ii) Digital type Voltmeter three phase class 0.5, 96 x 96 mm flush mounted case with adequate CT arrangement. (iii) Digital type Ammeter three phase class 0.5, 96 x 96 mm flush mounted case with adequate CT arrangement (iv) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each (v) Aluminium bus bar of Rating 800 Amp R-Y-B phases and Neutral. (vi) Base frame for cubical mounting made out of suitable size equal angle iron duly painted. (vii) Foundation for the panel should be provided with PCC 1:4:6 at a depth of 150 mm below G.L. and 100 mm above the G.L. with slot openings for I/C and O/G cables.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 25 sqmm to 50 sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 70 sqmm to 120 sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 150 sqmm to 185 sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 240 sqmm to 300 sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 400 sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and Fix aluminium bus bar red, yellow, blue and black colour coded heat shrinkable sleeve of size 25 x 5 mm fixed with suitable SS nut bolts etc in LT Panel including taking down unserviceable bus bar, complete all as specified and directed by Engr-in-Charge.
Supply and Fix aluminium bus bar red, yellow, blue and black colour coded heat shrinkable sleeve of size 40 x 10 mm fixed with suitable SS nut bolts etc in LT Panel including taking down unserviceable bus bar, complete all as specified and directed by Engr-in-Charge.
Supply and Fix On load changeover switch 4 pole of capacity 250 A with SS enclosure including spreader terminal kit conforming to IS/IEC-60947-3, complete all as specified and directed by Engr-in-Charge.
Supply and Fix On load changeover switch 4 pole of capacity 400 A with SS enclosure spreader terminal kit conforming to IS/IEC-60947-3, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MCCB of 160 A, adjustable type, 3 pole 415 volt 25 kA breaking capacity with adjustable over load, short circuit, ground fault (3 pole) & fixed instantaneous neutral protection(4 pole), conforming to IS/IEC-60947-2 with spreader terminal kit including taking down unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MCCB of 250 A, adjustable type , 3 pole 415 volt 36 kA breaking capacity with adjustable over load, short circuit, ground fault (3 pole) & fixed instantaneous neutral protection(4 pole), conforming to IS/IEC-60947-2 with spreader terminal kit including taking down unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MCCB of 400 A, adjustable type, 3 pole 415 volt 50 kA breaking capacity with adjustable over load, short circuit ,ground fault (3 pole) & fixed instantaneous neutral protection(4 pole), conforming to IS/IEC-60947-2 with spreader terminal kit including taking down unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MCCB of 160 A, adjustable type , 4 pole 415 volt 16 kA breaking capacity with adjustable over load, short circuit ,ground fault (4 pole) & fixed instantaneous neutral protection(4 pole), conforming to IS/IEC-60947-2 with spreader terminal kit including taking down unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MCCB of 250 A, adjustable type , 4 pole 415 volt 35 kA breaking capacity with adjustable over load, short circuit ,ground fault (4 pole) & fixed instantaneous neutral protection(4 pole), conforming to IS/IEC-60947-2 with spreader terminal kit including taking down unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MCCB of 400 A, adjustable type, 4 pole 415 volt 50 kA breaking capacity with adjustable over load, short circuit ,ground fault (4 pole) & fixed instantaneous neutral protection(4 pole), conforming to IS/IEC-60947-2 with spreader terminal kit including taking down unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of self engine stop relay device for 63 KVA to 180 KVA DG set AMF panel, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of self engine stop relay device for 200 KVA to 320 KVA DG set AMF panel, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of self engine stop relay device for 400 KVA to 625 KVA DG set AMF panel, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of AMF Controller device for auto/ manual function for 63 KVA to 200 KVA DG set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of AMF Controller device for auto/ manual function for 250 KVA to 400 KVA DG set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of AMF Controller device for auto/ manual function for 500 KVA to 750 KVA DG set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of AMF Relay Box for auto/ manual function including voltage monitor system and fully auto and manual system for upto 62.5 KVA DG set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of AMF Relay Box for auto/ manual function including voltage monitor system and fully auto and manual system for 62.5 KVA to 200 KVA DG set, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair of AMF Relay Box for auto/ manual function including voltage monitor system and fully auto and manual system for 250 KVA to 500 KVA DG set , complete all as specified and directed by Engr-in-Charge.
Material and Labour for Repair/replacement wiring of DG Set/AMF panel upto 25 to 50 KVA, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Repair/Replacement wiring of DG Set/AMF panel 62.5 to 100 KVA, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Repair/Replacement wiring of DG Set/AMF panel 125 to 320 KVA, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Repair/Replacement wiring of DG Set/AMF panel 400 to 625 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and Fix tripping indication switch in ACB/MCCB including taking down unserviceable tripping indication switch, complete all as specified and directed by Engr-in-Charge.
Supply and Fix spring charge indication switch in ACB/MCCB including taking down unserviceable spring charge indication switch, complete all as specified and directed by Engr-in-Charge.
Supply and Fix position indication switch in ACB/MCCB including taking down unserviceable position indication switch, complete all as specified and directed by Engr-in-Charge.
Supply and Fix adaptor type terminal for ACB/MCCB including taking down unserviceable adaptor type terminal, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc including taking down old unserviceable Earthing, complete all as specified and directed by Engr-in-Charge.
SREE HARITHA ASSOCIATES (BID ID -3357637)
R A Electric Co. (BID ID -3357562)
D.N.PATIL (BID ID -3357497)
M.K Enterprises (BID ID -3358221)
pk Enterprises (BID ID -3358056)
M/s PIONEER CONTRACTORS (BID ID -3358497)
K A ELECTRIC CO (BID ID -3358046)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .