Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.9 LAccepted-AOC | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹61.2 L+₹4.2 L (7.30%)Rejected-Finance BHATI ABHOYNAGAR WEST VIVEKANANDA CLUB ROAD NEAR HOUSE OF DOCTOR GOURISHANKAR CHAKRABORTY P O AGARTALA TRIPURA WEST PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹61.4 L+₹4.4 L (7.68%)Rejected-Finance | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹61.9 L+₹4.9 L (8.55%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | L5₹62.5 L+₹5.5 L (9.63%)Rejected-Finance | L5 | Rejected-Finance Quoted amount higher than L1 |
Tender Value
₹57 L
EMD Value
₹1.1 L
Closing Date
17 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col NK Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
SPL REPAIRS TO BLDG No OR-26 12 x OR MD ACCN IN ZONE E AT MIL STN AGARTALA
2023_MES_574501_3
8717/E8
Open Tender
Civil Works
Item Rate
180 days
Agartala
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
AGE (I) Agartala
₹1.1 L
Yes
7 Aug 2023
26 May 2023
24 Jun 2023
26 May 2023
17 Jun 2023
3 Jun 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding, (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of AC sheet corrugated / CGI corrugated sheets in roofing any gauge and any thickness including ridge, valley/gutter etc.
Dismantling timber boarding of any description fixed in any position complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of Unreinforced Cement Concrete/ Lime concrete of sunken floor (ground or 1st) and removing rubbish to a distance exceeding 150M but not exceeding 250 M complete all as specified and as directed.
Demolition and breaking up 100 mm dia internal dia bore drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean & washing down with water to remove dust etc and brushing neat cement slurry at the rate of 3 kg of cement per sqm complete all as specified and directed.
Supply & Fix in repairs 75 mm dia out let, Cast Iron Nahani Trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, Type B-1 complete all as specified and as directed.
Supply & Fix in repairs 100 mm dia out let, Cast Iron Nahani Trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4, Type B-1 complete all as specified and as directed.
Taking up or down 15mm bore steel water tubing & connections complete all as specified and as directed.
Taking up or down 20mm bore steel water tubing & connections complete all as specified and as directed.
Taking down cement plaster on brick concrete surfaces including racking out joints hacking for key, scrubbing down with, water etc complete all as specified and directed.
Taking down chowkat with shutter without taking off shutter from the frame n.exc 1.50 Sqm each complete all as specified and as directed.
Taking down chowkat with shutter without taking off shutter from the frame exc 1.50 Sqm but n.exc 4.00 Sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1.00 Sqm but n.exc 2.00 Sqm each complete all as specified and as directed.
Hacking out old broken glass ( any thickness, sizes, quality or description) from wooden frames or glazed with putty or fixed with beads complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F 35mm thick 2nd class Hard Wood, Plain, framed,panelled shutters(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
S & F Factory made, 35mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [b] and fitted to Chowkats complete all as specified and as directed.
S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with Particle Board Core, 28 to 30mm thick [Stiles], with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm plain colour PVC sheet on back face, termite proof, water proof and fire resistant, supplying & fixing in frame at site as per specification & drawing shown on Serial Page No. 181 of MES Schedule Part - II complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes, including Bolts, if required, Hooks [Stay], heavy, for Large Gates, Hook and Pintle Hinges, large Hasps and Staples, Chains, hand made Sliding Bolts, Clamps, Hold Fasts, Wall Ties, Hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
Supply and fix 125 mm size Butt hinges, heavy weight, cold rolled mild steel with galvanised MS sheet hinges pin anodised complete all as specified and directed.
S & F 100 mm size, Butt hinges, Extruded Aluminium alloy with galvanised mild steel hinge pin, anodised, Type B-21, including fixtures complete all as specified and as directed.
Supply and fixing 150mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed.
Supply and fix 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix mild steel sliding door bolts of size 300mm length of bolt, plate type, stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate & two on staple plate complete all as specified and directed.
Supply and fixing Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed.
Supply and fix steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
Supply and fix steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed.
Supply and fix mild steel work such as grills,gratings, guard bars etc and similar work conforming to Fe290 GDE E-165 complete all as specified and as directed.
Cutting holes into brick wall for inserting hold fast & making good dismantled portion in cm (1:3) or PCC (1:2:4) type B1, depth of cutting exe half brick but not exe one brick complete all as specified and as directed. Note: Cutting of holes will be carried out by using mechanical means like Groove cutter/ wall chaser.
Supply and fixing 4 mm thick sheet glass ordinary quality & glazing with oil putty, glazing pin etc in squares n. exe 0.5 sqm in each pane complete all as specified and as directed.
Supply and fixing 4 mm thick sheet glass frosted ordinary quality & glazing with oil putty, glazing pin etc in squares n. exe 0.5 sqm in each pane complete all as specified and as directed.
Supply and fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and as directed.
Supply and fixing in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and as directed.
S & F Mild Steel Door Spring 300 mm, Ordinary Rat Rail Rod Pattern springs including roller and roller plate complete all as specified and as directed.
Material and labour for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of steel surface over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Material and labour for preparation of old decorated steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old decorated wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of steel surface n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Material and labour for preparation of old steel surface n.exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
Material and labour for preparation of old decorated plastered ceiling surfaces and applying one coat of white wash complete all as specified and directed.
M & L for Complete removal of existing treatment of any description on wall surfaces and applying 3mm thick Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Oil Bound Distemper over one of alkali resistant primer on wall surfaces complete all as specified and as directed.
M & L for preparing newly plastered Wall surfaces and applying two coats of Oil Bound Distemper over a coat of alkali resistant primer over 2 mm thick Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and as directed.
M & L for complete removal of existing treatment on wall surfaces and applying Two coats of Weather Proof Paint over a Coat of Exterior Primer of same manufacturer as that of paint over 1 mm thick Cement based Wall Care Putty including necessary preparation of surfaces complete all as specified and as directed.
M & L for preparation of newly plastered wall / Ceiling surfaces and applying Two coats of Weather Proof Paint over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint over 1 mm thick Cement based Wall Care Putty complete all as specified and as directed.
Material & Labour non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.06 sqm but not exc 0.11sqm in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE
Material & Labour non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.11 sqm but not exc 0.18sqm in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE
Material & Labour non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.11 sqm but not exc 0.18sqm on skiriting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over backing coat of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Material & Labour glazed ceramic coloured tiles 350 x 250 x 7 mm thick of premium quality on skiriting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over backing coat of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Material and labour for precast cement concrete chequered tiles of size 250 x 250 x 22 to 25 mm thick as in floor, set and jointed and pointed with neat cement slurry laid over and including 20 mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed.
M & L for machine cut Kota stone slab flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
Material & Labour machine cut kota stone slab as in riser of steps, skirting, dado etc. using 20 to 25mm thick slabs laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including borders, margins in two or more shades of slabs over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed.
Materials and labour for 10 mm thick rendering on other than fair faces of brick work or concrete surfaces as on ceiling in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 5 mm thick rendering in CM (1:3) on fair face of concrete surfaces as in ceiling etc finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for 15mm thick rendering in CM (1:4) on concrete surfaces mixed with integral water proofing compound @ 3% by wt of cement, finished the surface even and fair complete all as specified and directed. (Note:Water proofing compound shall be measured & paid separately)
Material and labour for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. Note: Cutting of grooves will be carried out by using mechanical means like Groove cutter/ wall chaser.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:4 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, applying one coat of cold bitumenous primer @ 0.25 lits per sqm conforming to IS 3384-1986, and applying a layers of APP based polymeric membrane, 3mm thick (minimum) weight 3.50 Kg/sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over Bitumenious primer (Application of polymerie memberane shall be by torch application, over laps shall be minimum 100mm on the transverse direction & 75 mm on the longtudinal direction) coved fillet in PCC (1:2:4) type B-0 of radius 75 mm shall be provided at the junction of roof & other vertical surfaces & surfaces shall be painted with hot paving bitumen of penetration value 30/40 conforming to IS 73 @ 1.20 kg/sqm over a coat of bitumenous primer @ 0.30 ltrs per sqm & applying one coat of aluminium paint over the APP nmodified membrane @ 0.11 kg/sqm including taking down existing Roof Treatment of any description and removing rubbish to a distance not exceeding 50m complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only integral water proofing compound complete all as specified and directed.
Supply & fixing in repairs gun metal gate valve 20mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
Supply and fixing in repairs Vitreous China squatting pan of ‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern complete including provision of PCC bedding and connection to trap, flushing pipe, antisyphonage pipe, etc. including making good the disturbed floor complete all as specified and as directed.
Supply and fixing in repairs 10 litre capacity low level PVC flushing cistern (any colour), syphonic action type, with inlet, ball valve, float, handle, fixed with cast iron bracket (of suitable size) and providing 32 mm dia PVC flush pipe and making all necessary connections complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs vitreous china WHB of size 550x400mm including waste fittings, brass, chromium plated with long screwed shanks and flynuts, flange end bedded in red lead cement and other end fixed etc complete all as specified and directed.
Supply and fix in repair pillar taps 15mm dia bore fancy type with capstain heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified directed.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
S & F in repairs Brass Chromium Plated Shower Rose of size 125mm with or with out swivel joints fixing to steel pipes complete all as specified and as directed.
S & F in repairs Chromium Plated, Soap Dish, Fancy Type complete all specified and as directed.
Supply and fix in repair PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
Supply and fix in repairs 15mm bore stop valve fancy type,chromium plated , screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
Supply and fix in repairs 15mm bore fancy type chromium plated bib taps with crutch of butterfly handle screwed down for iron pipes complete all as specified and directed.
Supply and fix 20 mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed.
Supply and fix 15 mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed.
Dismantling timber fillets, rails, posts, rafters, purlins etc under 40 Sqcm in section complete complete all as directed.
Material and labour well seasoned 2nd class hard wood plain fillets, square, rectangular in section, clean sawn secured with nails or brads, sectional area exc. 13 but not exc. 25 Sqcm complete all as specified and as directed.
Material and labour well seasoned 2nd class hard wood plain fillets, square, rectangular in section, clean sawn secured with nails or brads, sectional area exc. 6 but not exc. 13 Sqcm complete all as specified and as directed.
Material & Labour for providing 18/19 mm thick Particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed.
Material and labour for extra over rates for block board or veneered particle board for external teak wood lipping complete all as specified and directed.
S & F Harrison Rails [Curtain Rails], Chromium plated, 20 mm dia alongwith 02 Nos. brackets, stops, rollers etc complete all as specified and as directed.
Supply and fix 100 mm size Butt hinges, heavy weight, cold rolled mild steel with galvanised MS sheet hinges pin anodised complete all as specified and directed.
S & F Hasp and Staple, safety type of aluminium anodised including bolt to hinge plate, fixed with screws of 100mm size complete all as specified and as directed.
Material and labour for PCC 1:5:10 type E2, using 40 mm graded stone aggregate as in sunken floor complete all as specified and directed.
Material and labour for 20 mm thick cement plaster in CM 1:4 mixed with Water proofing Compound @ 3% and applying water proofing treatment on sunken portion with acrylic based polymer modified cementitious composite compound as approved by GE and applying cement slurry two layers i.e. 1st layer @ 0.488Kg/ Sqm mixed with composite compound @ 0.253 Kg/Sqm & 2nd layer @ 0.242Kg/ Sqm mixed with composite compound @ 0.126 Kg/Sqm and applying 200 micron polyfilm with adhesive complete all as specified and directed. Note: Minimum 4 hours gap for air curing will be maintained between 1st layer and 2nd layer.
Supply and fix in repair 500 ltrs capacity rotational moulded polythene water storage tanks (Cylindrical vertical with closed top) hoisted & fixed in position complete all as specified directed.
Supply and fix 20 mm bore ball brass valve high pressure with polythene float & fly nut compelete screwed for iron pipe or brass ferrule complete all as specified directed.
Supply and fixing in repair low density polythene (LDPE) pins of pressure rating 6 Kg/Sq cm bore of tube 32 mm for waste pipe of WHB or sinks etc complete all as specified directed.
Supply and fix 75 mm bore dia PVC (SWR) pipes single socketed, in any length with rubber ring loints, fixed to walls complete all as specified and directed.
Supply and fix 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring loints, fixed to walls complete all as specified and directed.
Supply and fix 75 mm bore PVC (SWR) bends in any types complete all as specified and directed.
Supply and fix 110 mm bore PVC (SWR) bends in any types complete all as specified and directed.
Supply and fix 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S & F 110 mm bore PVC [SWR] Branch Piece, Single [Single "Y"] equal or unequal without access door including jointing with solvent cement complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Branch Piece, Single [Single "Y"] equal or unequal without access door including jointing with solvent cement complete all as specified and as directed.
Material and labour for 4mm thick asbestos cement plain building boards, fixed to MS framework with screws complete all as specified and as directed.
Supply and fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified complete all as specified and as directed.
Supply and fixing pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified complete all as specified and as directed.
Supply and fixing 20 mm thick second class hard wood boarding planed both side with butt joints fixed with nails in any situation complete all as specified and as directed.
Material & Labour for providing 75 mm thick plain cement concrete 1:3:6 type C-2, using (40 mm graded brick aggregate) as in path or paveway or plinth protection finished the surface fair and even complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed.
Material and labour Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls, built in cm 1:4 complete all as specified and directed.
M & L for PCC 1:3:6, Type C-1 [using 20 mm graded granite stone aggregate] in surface channels and drains including forming fair finished drain or channel of any inner girth using extra cement including forms, moulds, mitred / stooped ends complete all as specified and as directed.
M & L for Writing letters or figures [Block, Roman, Italic or Indian] not exceeding 30 cm high with thick paint to stand out boldly and solidly without showing signs of brush marks complete all as specified and as directed.
Taking down carefully existing copper/Aluminum point wiring (light,socket or power) complete including fittings such as switches, ceiling roses, pendents, sockets, boxes, light fitting etc and removing from site and making good disturbed surfaces of walls, floors etc complete all as specified and as directed.
Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping of suitable size with all accessories and PVC rectangular boxes for mounting switch, socket and fan regulator etc complete all as specified and as directed. Note: (i) Wiring shall be done in proper colour coding using red , yellow, blue for phase, black for neutral and green for earth. (ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate.
.-Ditto- all as per item No 108.00 here-in-before but for 3 pin 6 amps socket outlet on the independant board .
.-Ditto- all as per item No 108.00 here-in-before but for 3 pin 6 amps socket outlet on the same board.
.-Ditto- all as per item No 108.00 here-in-before but for one 3 pin 16 Amps socket outlet on independent board with 2.5 sqmm PVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor.
Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
Supply & fixing switch piano flush type (ISI marked), single pole, one way 16 Amp, 240 Volts complete all as specified & directed.
Supply and fixing socket out let 5 Pin, 6 Amps flush type complete all as specified and as directed.
Supply and fixing Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Flush Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 62.5mm x 50mm, ISI marked three terminals complete all as specified & directed.
Supply and fixing electronic fan regulator (step rotary type), AC 240 volt complete all as specified and as directed.
S & F Energy efficient & Long life Building Security Light Luminaire, of not less than 25 W, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing Fluorescent tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 20 W, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 10 W, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Supply and fixing piano bell push 6 Amps, 230 volt flush type complete all as specified and as directed.
S & F Buzzer, Ding dong AC, 230 Volts, Single Pole complete all as specified and as directed.
Supply and fixing MCB, single pole 'B' series having braking capacity 10 KA, 6 to 32 Amp, 240 volts, complete all as specified & directed.
Supply & Fixing MCB SPN having braking capacity 10 KA, 40 Amp, 240 Volt 'B' Curve complete all as specified and directed.
Supply and fix MCB triple pole & neutral 63 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections suitable for DB in double door with proper size of aluminium lugs complete all as specified as directed .
S & F MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including taking down of existing unserviceable DB with MCBs including making good disturbed surfaces complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wallincluding taking down of existing unserviceable DB with MCBs including making good disturbed surfaces complete all as specified and as directed. Note for serial Item No. 123 to 127: MCB and MCB DB shall be of same make as approved by AGE (I).
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC Casing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces inculding taking down the old unserviceable one all as specified as directed. Note : (i) 3 Runs of 4.00 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length. (ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate.
Taking down ceiling fan carefully of any size from its original position, kept in safe custody and refixing the fan in same position or at new place including cleaning complete all as specified and directed.
Taking down exhaust fan carefully of any size from its original position, kept in safe custody and refixing the fan in same position or at new place including cleaning complete all as specified and directed.
Taking down KWH meter of any description, from its original position, kept in safe custody and refixing in the same position or at new place including cleaning complete all as specified and directed. complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
SUMAN DEB
M/S SANKAR GOPE
SHRI RAJESH DEY
SHRI CHANDAN CHANDA
SHRI SUBRATA GUHA
M/S PRITAM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .