| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-AOC ADD GROUND FLOOR G B PLOT NO 380 TUNGRI WARD NO 19 CHAIBASA WEST SINGHBHUM 833201 | CHAIBASA | WEST SINGHBHUM | JHARKHAND | 833201 | ₹4.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹5.1 Cr+₹21.2 L (4.34%)Rejected-Finance | ₹5.1 Cr+₹21.2 L (4.34%) | L2 | Rejected-Finance L2 |
| 3 | L3₹5.1 Cr+₹24.3 L (4.96%)Rejected-Finance KUNWAR SADAN VEER KUNWAR SINGH COLONY AIRPORT ROAD HINOO RANCHI 834002 JHARKHAND | RANCHI | RANCHI | JHARKHAND | 834002 | ₹5.1 Cr+₹24.3 L (4.96%) | L3 | Rejected-Finance L3 |
| 4 | L4₹5.5 Cr+₹60.9 L (12.5%)Rejected-Finance 202 SHRILOK COMPLEX H B ROAD THARPAKHNA RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | ₹5.5 Cr+₹60.9 L (12.5%) | L4 | Rejected-Finance L4 |
| 5 | L5₹5.9 Cr+₹96.2 L (19.7%)Rejected-Finance DUMKA ROAD OPPOSITE IRRIGATION COLONY JAMTARA JHARKHAND 815351 | JAMTARA | JHARKHAND | 815351 | ₹5.9 Cr+₹96.2 L (19.7%) | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹6.1 L
Closing Date
10 Jan 2024, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya, Dhurwa, Ranchi-834004.
Construction of Office Building for Jharkhand State Electricity Regulatory Commission at Hinoo, Ranchi
2023_JSBCC_79159_1
JSBCCL/79/2023-24
Open Tender
Civil Works - Buildings
Item Rate
365 days
Ranchi
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹6.1 L
13 Mar 2024
20 Dec 2023
12 Jan 2024
20 Dec 2023
10 Jan 2024
20 Dec 2023
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B).
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.
Supplying chemical emulsion in sealed containers including delivery as specified (chlorpyriphos/ lindane emulsifiable concentrate of 20%)
Providing designation 75 A brick work in C.M.(1 :6) in foundation & Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials, scaffolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75B brick work in CM (1:6) in Foundation with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I
Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I.
Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level
1:3:6 (1 Cement: 3 coarse sand(Zone III): 6 graded stone aggregate 20 mm nominal size)
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse send : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size ,wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position mixed or site batched design mix Cemwnt conrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources portland pozzolana / ordinary portland / Portland slage cement, admixtures in reinforcement proportions as per IS: 9103 to accelerate, retard setting of concrete, improve durability and workability without impairing strength including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, and for the following grades of concrete. Not- Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 of the specifed minimum cement concrete, the contractor shall have discretion to either re -design the mix or bear the cost of extra cement.
All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg/cum
All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg/cum
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs,(excluding landings) except spiral-staircasess.
Weather shade,Chajjas, corbels etc. including edges
Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick.
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in wall (any thickness), including attached pilasters, butterses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and struts ets. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floor, roofs having slope up to 15'' landing, balconies, shelver, chajjas , lintels, bands, plan window sills, staircases and spiral stair case above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. Taking 8mm TMT FE 500 ( only valid for SAIL & TATA STEEL)
Providing Tor steel reinforcement of 10mm, 12mm & 16mm mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l.
10mm TMT FE 500 (only valid for SAIL & TATA Steel)
12mm TMT FE 500 (only valid for SAIL & TATA Steel)
16mm TMT FE 500 (only valid for SAIL & TATA Steel)
20 & 25 mm TMT FE 500 (only valid for SAIL & TATA Steel)
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l
Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l
Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush door shutter in door and window with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50x12 mm
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Providing and fixing aluminium extruded section body tubular type universal huydraulic door closer (having brand log with ISI, IS:3564) embossed on the bodyu, door weight upto 36kg. To 80 kg. and door width from 701mm to 1000mm) with double speed adjustement with necessary accessories and screws etc. complete
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete Twin rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers anda pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (El20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B. Fixing with adjustable lugs with split end tail to each jamb
Supplying, fitting, and fixing M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing , properly fabricated with joints continuous fillet welded and finished, carriage of grill to work site, hoisting as per building speficiation and direction of E/I. (where material is not supplied by the deppt.)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supplying, fitting and fixing 20 guage GCI sheet gate fitted on M.S> angle frame of size 60X60X6mm including cost of fabrication providing necessary locking arrangement with haskal and domny duly fixed in PCC (1:2;4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Supplying,fitting and fixing M.S. grill gate with M.S. grills made of 20xGmm M S. flats or 16mm. M.S. square bars fitted on25x25x 6mm. M.S. Angle frame -do- (when steel is not supplied by the deptt.).
Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where material is not supplied by the deppt.)
Supplying fitting and fixing fully steel glazed doors, windows and ventilators of standard rolled 'Z' and mullion steel sections and size as per IS-1038, joints mitred and welded with 100x16x3 mm MS lugs fixed in cement concrete (1:2:4) blocks 15x10x10 cm , size including cost of oxidised iron fittings, with hinges, handle per steps , catch springs , 3 mm thick glass panes with alluminium beads and inner frame fixed with lugs with 20 mm long 6.3 mm gi counter sunk machine screw and nutsand applying a coat of red lead paints carriage to work site hosting and placing in position in all storied and taxes all comlete as per building specification and direction of E/I ;
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285 fixing with dash fasterners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required DPDM rubber/neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/panelling C.P. brass/stainless steel screws, all complete as per architetural drawings and the directions of Engineer-in-charge (Glazing, panelling and dash fasteners to be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, windows, ventilators, shutters and partitions etc, with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge (cost of aluminium snap beading shall be paid in basic item)
With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm mild steel U beading
Providing and laylng Doublecharge vitrrfied floor tiles in diiierent sizes (thickness to be i specrfred by the manufacturer) with water absorption less than 0.08% and conforming to lS 15622 / ISO 13006 of approved make in all colours and shades laid on 20mrn thick cement mortar 1:4 (1 cement:4 coars sand) jointing with grey cement slurry @ 3.3 kg/ sqm including I grouting the joints with white cement and matching pigments etc complete Size of tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment,epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade (Area of slab over 0.50 sqm)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Extra for flooring work for each consecutive floor above first floor complete as per direction of E/I.
Second floor
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
25mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with
Second class teak wood
Providing 25mm thick first class patent stone flooring (1:2:4)with stone chips in two layers, bottom layer 19mm. thick (1:2.4)with 12mm to 6mm. size graded stone chips and top layer 6mm. thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/1.
Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 12mm Thick cement plaster (1:6) with clean coarse sand F.M. 1.5 including screening, curing with all lead and lifts of water, scaffolding, taxes and royalty, all complete as per building specifications and direction of E/I
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 1.5 mm. cement punning including curing carrage of water withall leads and lifts as per building specification and direction of E/I
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/I
Second Floor
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Making 6x6mm grooves in plaster surface over walls truely horizontal or vertical as specified. at regular intervals, at all heights including cleaning, finishing, scaffoding and curing wth all leads and lifts of water all complete as per building specification and direction of E/|
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface inluding preparing the plastered surface by rubbing wmooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per buiiding specification and drrection of E/i.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing two coats of synthetic enamel paint of approved shade and make over new wooden surfaces including preparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes, all complete as per building specifications and direction of E/I
Providing French spirit polishing over new.wooden surface to give desired texture and gloss with approved make and shade of ready mixed French polish including cleaning the surface after removing dirt scales, smokes, grease and sand papering, including cost of scaffolding and taxes, all complete as per building specifications and direction of E/I
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
Providing & laying water proofing treatment in sunken portion of WCs, bathrooms etc. by applying cement slurry mixed with Armourcrete of M/S The Structural Water Proofing Company PVT. Ltd.or Tapecrete of M/s CICO Engg. Servce consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @ 0.125 kg/ sq.m. This layer will be allowed to air cure for 4 hours
(b)second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @ 0.126 kg/ sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preperation of surface, treatment& sealing of all joints, corners, junctions of pipes & masonary with polymer mixed slurry.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building speicification and direction of E/I.
Water proofrng for Old and New Roof Slab :- Providing and laying waterprooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible,material applied with brush, roller or spray for wate proof i n g coating as per manufactlrer specificatio With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dLrst, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from sofftt to identify seepage, leakage. On identiiication of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joinis such as those betr,veen the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the sl u rry ?!gc!ylic polyrner Repai rin g su rface irreg ularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair moriar ir;cluding a coat of bonding agent of the same with ceme nt slurry rncluding all rnaterial, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, llexrble cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/SqmUcoat For the fJUrpose of n'ieasurernent tite entire treated surface will be measured."
(c) :2nd Cr:ai :-T,: apply the 2nd coat of two component acrylic modified, reatiy to-use, flexible cementttious material right angle to the '1st coat over the glass fibre liad surface. 2nd coat should be applied @0.7 kgl Sqrnt/coat. For the pltrpose of measurement the entire treated surface will be rneasurecl." Alte r three days of drying the 2nd coat, therainwater ouilets to be plugged and ponding test to be done for 48 hours to rrjerrtify se epage, leal<age from soffit and if found necessary rectification lo be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectifcation to be done as per satrsfaction of E/C protected from damage before screed over it. Watqr proofing Brand:*Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A. Acrylic copolmer, Part B Specially graded cementitious powder - Density 1.6 l.rg/l (mixcd density) at +27oC Tensile Strength - 2 lllmm2 after 28 clays (with Fibre cloth) (According to ASTM D 2370)Prillcut Bond Streric;tl-r '-2 I'J/mm2 (concrete lajlqry) (Aqgcrdlglq ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.'15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Clot (Accordrng to ASTM D 2370)
(d) Protection of treated surface with PCC- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( '1:120) towards tlre rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mrn gap betuieen the panel joint. lntegralwater proofing admixture conforming to lS 2645 @ of 100 ml per bag of of cement to be added in the scree d concrete(pard separately for thts ltems).-All corners shall be charrmfered with 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface slrould be packed properly with rich concrete and the peripheral mouih to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose ofrreasurement the entire treated surface will be measured."
(e) Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc Warranty for Five years.
Covering of treated surface wrth PCC :- Providing 25 mm thick Cementn Concrete M20(1:'1.5:3) r'naintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Providing and mixing Liquid lntergral water proofing compound in Conctrete or plaster as per rnanufacturer specificatioqand as per cjirection of Eng - in Charge Brand- Sika Plastocrate plus, MYK proof WP 1 0, Fosroc-Cc.rnplast X4211 C, Dr fixit Pidiproof LW+ or Equivalent
Provrding and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as per drawings and technical specifications and direction of E in Charge (with 18% GST).Brand:-SikaPolysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutoutsmade with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . (i) Single socketed pipes.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Bend 87.5 degree 75 mm bend
Bend 87.5 degree 110x110x110mm
Shoe (Plain) 110mm shoe
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less thaN 440 grams.
Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete - 110mm
Making khurras 45x45 cm. with average minimum thickness of 55 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) over PVC sheet1mx1mx400 micron, finished with12 mm cement plaster1:3 (1 cement : 3 fine sand) and a coat of neat cement, roundingthe edges and making and finishingthe outlet complete
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer-in-charge which are machine cut for duct/shaft covering, partitions andfacades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/ moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately.
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
Supply of cement concrete brick wall tile (size:225mmx75mm) (Thickness: 14mm) (Weight per piece :430 gms approx) (Bricks Colour: Natural Brick Colour) Cladding water absorption 3% to 6% confirming to IS: 1237:2001, of approved brand & manufacturer, as approved by the architect.
Providing, fixing, and installing, 10 passenger Lift well size - 2050(W) x 2000(D), No. of Stops 03, Openings- 03, Ground Floor 3.45m ht., First Floor ti 2nd floor 3.75m ht., Clear Door Opening- 900mm, Speed of Lift - 1.0M/s, Automatic rescue device, etc., with all necessary features, machine room less, Brushed golden Stainless steel finish on rear wall, Silver Hairline SS finish on remaining walls and ceiling, all complete as per specification and instruction of Engineer in charge.
Providing, fixing, and installing, 13 passenger Lift well size - 2100(W) x 2000(D), No. of Stops 03, Openings- 03, Ground Floor 3.45m ht., First Floor ti 2nd floor 3.75m ht., Clear Door Opening- 900mm, Speed of Lift - 1.0M/s, Automatic rescue device, etc., with all necessary features, machine room less, Brushed golden Stainless steel finish on rear wall, Silver Hairline SS finish on remaining walls and ceiling, all complete as per specification and instruction of Engineer in charge.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoirs, sewage and water treatment plant, tunnels/subways, and bridges etc. prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 parts water) for horizontal surfaces and applying the same from negative (internal) side with the hlep of synthetic fiber brush. The materials shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 ad resistant to 16bar hydrostatic pressure on negative sides. The crystalline slurry shall be capable of self healing the cracks upto width of 0.50mm. The work shall be carried out all complete as per specification and direction of E/I. The product performance shall carry guaranteed for 10 years against any leakage
For Vertical Surfaces two coats @ 0.70 kg per SQM
For Horizontal Surfaces two coats @ 1.10 kg per SQM
Supplying and fixing C.I. cover without frame for manholes : 560 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 m deep with 45x45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
CARRIAGE OF MATERIALS
Bricks (1K+ 7P = 8 KM.)
Coarse Sand (10 KM.)
Stone Chips ( 22 KM.)
Stone Metal ( 22 KM.)
Earth - 1km
Local Sand (3 KM)
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (i) With "P" trap (b)10.0 lit. low level P.V.C. cistern
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flush pipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I. (A) 580 mm long . C-with 10.0 litre low level PVC cistern
Supplying, fitting and fixing flat back or angular lipped front vitreous white glazed earthern ware urinal of Hindustan "Parry" or any other approved ISS make with 5 ltrs. Capacity C.I. automatic fushing cistern of reliance for any other ISS approved make with all fittings with C.I. or RS brackets standard size G.I. flush pipe with fitting clamps 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 gms. 15mm PVC alkethene pipe 450mm long with brass coupling at both ends and doing plumber points including painting of exposed part with two coats of approved paint over a priming coat of red oxide cutting wall and floor making good the same etc. all complete as per speciifcification and direction of E/I. Flat back or standing corner (600X350mm)
supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.
Providing and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.
20mm dia.and weight not less than 300 gms.
25mm dia.and weight not less than 500 gms.
32mm dia and weight not less than 700 gms.
40mm dia and weight not less than 1.0 kg.
Providing and fixing brass/ C.I stop cock of approved quality all complete as per specification and direction of E/I
(A) Brass Stop Cock
(a) 15 mm dia
Cutting chajjas or concrete for laying PVC Pipe and restoring the same with R.C.C. (1:2:4) brick work in cement Mortar (1:4) and cement plaster 1:4 as per specifiction and direction of E/I
Making holes in walls for laying G.I Pipes and restoring the same atfer pipe Laying as per specifiction and direction of E/I (b) 250mm thick wall
Cutting drain width wise above GL for laying H.C.I pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I.
Making holes in wall for laying H.C.I pipes and restoring the same after pipe laying as per specifciation and direction of E/I. (i) 125 mm Dia
Supplying all tolls and labour and cutting chajja cornice for laying H.C.I pipes and making good the same as per specification and direction of E/I.
Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I. (all rates have been adopted from the basic rate from SOR + 15% for labour and Contractors profit)
Pillar cock (Long neck)
Bib cock - long thread
Angular stop cock L.T
4 way diverter for concealed fittings
Glass shelf 22''
Flush valve complete with 32mm size control cock & flange
32mm dia. PVC waste pipe 750mm long with Coupling
40 mm dia. PVC waste pipe 70mm long with Coupling
15mm C.P. nipple with coupling (short pieces)
Steel jali - 100mm dia.
Providing Solvent cement
Providing and fixing Pressure adjustable shower with revolving joint
Supply, fitting and fixing Central hole basin mixure without popup waste system
Supply, fitting and fixing Towel ring
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I
Mirroes of 6 mm thick plat glass bevelled edge mirror including C.P brass revolving fitting 3mm ply wood board and C.P hinges to fix with mirror. (i) 600mm x 450mm size
(i) C.P. brass towel rail 20mm X 600mm with bracket container
(ii) C.P. brass dish container medium quality with screw and hinges etc.
Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc all complete as per specification and direction of engineer in charge
Supplying, materials and labour for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600X450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600X475mm G.I. cover with frame (weight not less than 35kg) alongwith earth work in excavation and 80mm thick PCC (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china china cistern with dual flush fitting of flushing capacity 3litre/6litre (adjustable to 4 litrs/8 litres) including seat cover and cistern fitting nuts bolts and gasket etc complete.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931, 15mm dia nominal bore of approved brand C.P. fittings
Providing and fitting C.P. brass angle vale basin mixer and geyer points of approved qulity confirming to IS 8931 15mm nom inal bore approved brand C.P. fittings
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing PTMT BottleTrap forWash Basin and Sink .
Bottle trap 31mm single piecemoulded with hight of 270 mm, effective length of tail pipe 260mm from the center of the waste coupling, 77mm breadth with 25mm minimum water seal weighing not less than 260 gms.
Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per IS:13983 with C.I. brackets and staom;ess stee; plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required
Kitchen sink with drain board - 510X1040mm bowl depth 250mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc.
15mm nominal bore
20mm nominal bore
25mm nominal bore
32mm nominal bore
External work - 40mm nominal bore
External work - 50mm nominal bore
External work - 65mm nominal bore
External work - 80mm nominal bore
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade ( Size 0.45x0.900x2= 0.81
Providing & fixing on wall face unplasticised - Rigid P.V.C. pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Single Tee with door 110x110x110 ,mm
Bend 87.5 degree 110 mm bend
Providing and fixing square mouth S.W. gully trap grade 'A' complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water tight C.I. Cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 100x100 mm size P type with common burnt clay F.P.S.(non module) brick of class designation 7.5
Constructing brick masonary road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement :4 coarse sand ) including 500x450 mm precast RCC horizontal grating with frame complete as per standard design . with common burnt clay F.P.S.(non module) brick of class designation 7.5
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe
150 MM dia R.C.C. pipe
250 MM dia R.C.C. pipe
300 MM dia R.C.C. pipe
Supplying and fixing PVC fittings of approved make confirming to IS : 1729 including supplying nails and bobbins, fixing solutions including earth work or masonary work cutting and remaking and providilding as the case may be all complete as per specification and direction of E/I. ( Add 15%)
Slotted cowl (terminal guard) 100 mm dia
Floor trap - 100mm dia.
Ring rubber
Door piece
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying submersible pump sets confirming to lS 8034 and motor confirming to lS 9283. Pump shall be suitable for various Deliver head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V110%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump. Submersible Pump set 100 mm dia (with Polypropylene/ Noryl lmpeller) up to 20 stages 2.0 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes ,royalty etc all complete job as per direction of E/I. ( 5 to 10 H.P)
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
(Door Name Sign MPI WM Size-450 x 125) Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with Lifetime warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Wall Projected Sign MPI Projected Size-250 x 187) Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with Lifetime warranty under normal working conditions.Sign is double sided with 2 aluminium profiles connected with each other with 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted media (vinly) warapping by virtue of design of profiles. One end cap screw fitted with wall (rigid base) .Media can be flat bed UV printed on panels/ profiles .Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Passage Suspended Sign MPI Suspended Size-900 x 156) Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with Lifetime warranty under normal working conditions.Sign is double sided with 2 aluminium profiles connected with each other with 2 plastic moulded endcaps.Galvanised iron multistrand twisted 2 mm diameter wire (upto1.5 meter in length) with Stainless steel eco-suspension clips screw fitted directly in ceiling (rigid base) engaged with wire stainless steel eco suspension clips with wire adjustment mechanism.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Main Directory MPI Directory Size-2000x1000) Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with Lifetime warranty under normal working conditions.Sign is single sided with aluminium side tracks and common click clips for panel fitting. a.Sign is including all plastic injection moulded clips black in shade which are slided in side tracks ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Toilet Door Signs MPI W/M Size-156x156) Providing a signs made as using Cosign india make .Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with Lifetime warranty under normal working conditions.Sign is single sided with aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media (vinly) warapping by virtue of design of profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Lift In case of Fire Use stairs Sign MPI WM Size- 320x 156) Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with Lifetime warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Fire extinguisher Cylinder Sign MPI WM Size- 250 x 187) Providing a signs made as using Modular Aluminium extrusions (Alloy 6060 as per European standards EN755-2-2008 tensile strength 190 MPa typical BHN is 70 from virgin aluminium homogeneous billet) with Premium grade Anodizing (Thickness 15-20 microns) as per International standards, with Lifetime warranty under normal working conditions.Sign is single sided with 1 aluminium profile click fitted on 2 plastic moulded endcaps.Sign is including all plastic injection moulded end caps black in shade which are directly press fitted ,media can be flat bed UV printed on panels/ profiles.Cosign make MPI panels fitted and installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Emergency Exit Signs -illuminated COE02 Size-310x225) Providing ready sign & fixing at location a Cosign make emergency exit sign- illuminated, surface mount (wall or ceiling) Dual sided made up of plastic material , battery backup of 3 hours (180 mins) .Battery life of 300 cycles of charge & discharge Li- ion battery 3.7 Volt, 100 mA, Charge time of 24 hours. Input voltage 220-240 Volt A.C, 50/60 Hz. Viewing distance 30 meter, degree of protection IP20 (rating for protection against solid object upto 12 mm) white light colour full back (white colour) LED illumination with green white coloured graphic inserted on both sides on 0.4 mm PC (sizes, texts, symbols or graphics as per standard safety norms & regulations) graphic options of -left ,right, up staircase down staircase. Test facilty button self test plus auto self test, opreration in maintained and non maintained mode (power saver mode).Sign with 12 months warranty for electric circuit & 6 months warranty for battery. Sign provided with dual mounting arrangement of mounting on wall & celing both ( with flat rigid support/base).Sign is including all connection wires (upto 1 mtr) & high tensile strength zinc coated self tapering screws (4 nos with screw wall plastic packing), installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
(Main Signage of Building SS Size- 650 Inches ) silver glossy finish 3D letter jindal make with stainless steel material, 0.8mm 304 grade type steel, customized letter as per the design
(Main Door Name Plate SS Size- 2400X1200) silver glossy finish Engraved signage, jindal make with stainless steel material, 0.8mm 304 grade type steel, customized letter as per the design
Point Wiring in Medium Class PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed with PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. FR PVC Copper Wire (Confirming to IS: 694-2010, 1.1 KV) :- Make:- Havells, Polycab, Rajnigandh, RR Cable. (Make of Modular switch Sockets:- Havells (ATHENA), L&T ENGLAZE), Legrand (LYNCUS) , Anchor(WOODS), Schneider-(OPEL) Group-C
Twin Control Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed Medium Class PVC conduit, 2 way modular switch, modular plate, suitable size of GI box earthing the point with 1.5 Sq. mm FR PVC insulated copper conductor single core cable etc as required. FR PVC Copper Wire (Confirming to IS: 694-2010, 1.1 KV) FR PVC Copper Wire (Confirming to IS: 694-2010, 1.1 KV) :- Make:- Havells, Polycab, Rajnigandh, RR Cable. (Make of Modular switch Sockets:- Havells (ATHENA), L&T ENGLAZE), Legrand (LYNCUS) , Anchor(WOODS), Schneider-(OPEL)
Power plug wiring in PVC conduit (2x4 sq.mm.):- Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated copper conductor single core cable in surface/recessed Medium Class PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc. as required. FR PVC Copper Wire (Confirming to IS: 694-2010, 1.1 KV)Make:- Havells, Polycab, Rajnigandh, RR Cable.
Circuit/Sub-main wiring in PVC Conduit:- Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper condcutor, single core cable in surface/ recessed Medium Class PVC conduit as required. FR PVC Copper Wire (Confirming to IS: 694-2010, 1.1 KV) Make: Havells, Polycab, Rajnigandh, RR Cable.
2x1.5 Sqmm + 1x1.5 sqmm earth wire
2x2.5 Sqmm + 1x2.5 sq mm earth wire (UPS CIRCUIT)
2x4.0 Sq.mm + 1x4.0 Sq.mm earth wire.
2x6.0 Sq.mm + 1x6.0 Sq.mm earth wire .
2x10 Sq.mm + 1x6.0 Sq.mm earth wire .
4x6.0 Sq.mm + 2x6.0 Sq.mm earth wire.
4x10 Sq.mm + 2x6.0 Sq.mm earth wire.
S/F PVC Conduit: Supplying and fixing of following sizes of med Class PVC conduit of 2 mm thick along with the accessories in surface / recess & cutting the wall and making good the same in case of recessed conduit as required . (Make:- Polycab, Precision, AKG)
Supply and fixing of following size PVC/G.I. box on surface /recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
S/F Modular type Switch / Socket:- Supplying and fixing of following switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as requried. (Make of Modular switch Sockets:- Havells (ATHENA), L&T ENGLAZE), Legrand (LYNCUS) , Anchor (WOODS), Schneider-(OPEL)
5/6 amps switch
15/16 amp switch
3 pin 5/6A socket outlet
6 pin 15/16 amp socket outlet
S/F Modular type electronic fan regulator:- Supplying and fixing 2 modules Stepped type electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as requried. (Make :-Havells, Legrand , Anchor, Schneider.)
S/F Modular blanking plate:- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Make - Havells, Legrand , Anchor, Schneider.)
Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required. (Make :- Havells, Legrand , Schneider).
1or 2 module (78mmx 78mmx 45mm)
4/5 module (78mm x 140mm x 50mm)
6 module (78mmx 205mmx 50mm) (for 2 nos. 6A Sockets & 2no. 6A Switch)
S/F Light plug point with modular type accessoris:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular type switch, connections painting etc. as reqd. (for Light plug point). (Make:-Havells, Legrand , Schneider, L&T.)
S/F Power plug ponit with modular type accessories:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular type switch, connections painting etc. as reqd. (Make:- Havells, Legrand , Schneider, L&T.)
S/F Ceiling Rose:- Supplying & fixing of 2 pin, 5 amp Ceiling rose on the existing junction box/ wooden block including connection etc. as required. (Make:- Anchor, Kona)
S/F Batten / Angle Holder:- Supplying and fixing brass batten/angle holder including connection etc. as required. (Make:- Anchor, Kona)
S/F Electronic Musical Call Bell Supplying and fixing of Electronic Musical call bell suitable for single phase, 230 V, complete as required. (Make:- Anchor, reputed)
ITC fluorescent fitting with Down Rods:- Installation, testing and commissioning of suspended pre-wired ,fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
ITC ceiling fan:- Installation, testing and commissioning of Ceiling fan, icluding wiring the down rods os standard length (Up to 30Cmm) with 1.5 sq. mm FR PVC insulated, copper conductors, single core cable etc. as required.
ITC exhaust fan upto 450 mm sweep:- Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required.
S/F MCCB in Panel Board:- Providing and fixing following rating and breaker capacity MCCB with thermomagnetic release and thermal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 25-100 amps, 16 KA fixed thermal setting
DISTRIBUTION BOARD & MCB/RCCB S/F SP MCB DB:- Supplying and fixing following way, SP&N MCB doubel distribution board of sheet steel for 240 Volts on surface /recess complete with tinned copper bus bar, neutral busbar, earth bar, detachable gland plate, interconnections, phophatized and powder coated painted including earthing etc. as required ( But without MCB/RCCB/ ISOLATOR). (Make:-SIEMENS-Bitaguard, LEGRAND-Ekinox³-, SCHNEIDER-ACTI-9, L&T-AU)
8 Way Double Door
12 Way Double Door
16 Way Double Door
S/F TP MCB DB: - Supplying and fixing following way, horizontal type double door three pole & neutral, sheet steel, MCCB distribution board, 415V, on surface/ recces , complete with tinned copper bus bar, neutral bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCCB/RCCB/Isolator) (Make:-SIEMENS-Bitaguard, LEGRAND-Ekinox³-, SCHNEIDER-ACTI-9, L&T-AU
4 ways (4+12) Double Door. (horizontal type)
6 ways (4+18) Double Door. (horizontal type)
8 ways (4+24) Double Door. (horizontal type)
S/F VERTICAL TYPE T.P. MCCB DB:- Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCCB distribution board of sheet steel dust protected, duly power painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar mounting MCCB's (but without MCCB's and Incomer) as required. Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required. (Make:-SIEMENS-Bitaguard, LEGRAND-Ekinox³-, SCHNEIDER-ACTI-9, L&T-AU 4 way (8 + 12) Double door, Vertical Type
S/F 'C' Series MCB:- Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, 'C' curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:-LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200MSIEMENS- BETA GUARD/ L&T- AU VERSION).
6-32 Amps. Single Pole
6-32 Amps Double Pole
40 Amps Double Pole
6/32 Amps TPN
50/63 Amps TPN
S/F SP MCB Blanking Plate:- Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.(Make:- L&T, Legrand, Schneider,Siemens)
S/F SPN RCCB:- Supplying & fixing following rating double pole (Single Phase & Neutral) 240 V, Resudual Curren Circuit Breaker (RCCB) , having a sensitivity current uo to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:- LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200MSIEMENS- BETA GUARD/ L&T- AU VERSION.)
P/F MV Danger Notice Plate:- Providing & fixing of M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
G.I. Pipe Earthing:- Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including accessories, and providing massonry enclosure with cover plate having locking arragement and watering pipe etc. with charcoal/cock and salt as required.
Main LT Panel- 2 nos
APFC Panel - 2 nos.
Pump Panel- 2 nos.
External L:ighting Panel 2
2 nos.Lift Machines - 2x2= 4 nos.
UPS 2 nos.
Server Rack & EPBEX Machine 2 nos.
Total - 16 Nos.
Supplying and laying of 8 SWG G.I. copper wire at 0.50 meter below ground level for conductor earth electride, including soldering etc. as required.
S/L 25mmx5mm G.I. strip as strip earth electrode :- Supplying and laying 25 mm X 5 mm GI strip at 0.50 meter below ground/surface as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm).
P/F G.I. lighting conductor finial:- Providing and fixing of Lightning Conductor finial, made of 25 mm dia 300mm ling, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Reverting, Sweating and soldering Lightning Conductor Tape:- Reverting, Sweating and soldering of Copper/G.I. Tape (with another Copper/G.I. tape, base of the finial or any other mettalic obect) as requried.
P/F G.I. lightning conductor tape in horzontal run :- Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for lightning conductor complete as required. (for Horizontal Run).
P/F G.I. lightning conductor tape in Vertical run:- Providing and fixing G.I. Tape 20mmx3mm thick on parapat or surface of the wall for lightning conductor complete as required. (for Vertical Run).
P/F Testing joint for GI lightning conductor :- Providing and fixing testing joint made of 20mm * 3mm thick GI strip 125mm long. With 4 nos. of GI bolts. Nuts chuck nuts and spring washers etc. complete as required.
G.I. Pipe electrode with Salt/Charcoal:- Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arragement and watering pipe etc. with charcoal and salt as required.
S/L 25 x 5mm G.I. earth strip in 50 mm below ground:- Supplying and laying 25mmx5mm G.I. Strip at 0.50 meter below ground as strip earth electrode, including connection/ termination with G.I. nut bolts, spring washer etcas required. (Jointing shall be done over and 2 sets of G.I. Nut Bolts & Spring washer spaced at 50mm).
MV Cable Laying up to 35 sq. mm. in ground :- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. direct in ground including excavation, sand cushioning, protective covering by 2nd class bricks and refilling the trench etc as required.
MV Cable Laying up to 95 sq. mm. in ground :- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding 35 sq.mm. but not exceeding 95 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
MV Cable Laying up to 400 sq. mm. in ground ;- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
MV Cable One Number additional Laying up to 400 sq. mm. in ground ;- Laying of one number additional PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supply, installation, testing and commissioning of of following size ceiling fan 3 blades confirming to IS:- 374:2019 including wiring tne down rods, of standard length (up to 30 cm) with 1,5 FR PVC insulated, copper wire suitable for 230 Volts, 50 Hz, single phase supply etc. complete as required.( BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fans and two yeas warranty ) (Make & Model nos. of Fans are to be approved by Engineering Incharge & Consultant before procurement.) Supply of 48" (1200 mm) Sweep Ceiling fan BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fan. Make :Usha/Crompton/ Havells/GEC.
SITC of 230 mm (9") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/Crompton / Havells /GEC.
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Polar/Usha/Crompton / Havells . .
SITC of 400 mm (16") sweep AC 230/250 volts, 50 HZ Wall Mounting Revolving Fan with brackets, cooper winding, etc. complete all electric room etc. Make :- /Usha/Crompton / Havells /GEC.
All the LED lamp shall be of minimum 100 or above lumens per watt and the LED BATTEN TUBE LIGHTS & other LED light fixtures shall be of 100 or above lumens per watt. LM 79 and LM 80 reports need to be submitted with all accessories by the contractor. All LED Lights (Make & Model nos. of LED Liughts are to be approved by Engineering Incharge & Consultant before procurement.) Burning Hours should be less than 35000 to 50000 hrs. Make:-Havells/Sygnify-Philips/ Bajaj/ Jaquar. .
SITC of following rating recess/surface mounted LED round/square shape Down Light Luminarie with pressure die-cast housing for single phase supply voltage. Luminarie shall be confirm to IS; 10322 part-5/section-2 or IEC 62722 with all necessary accesoreies as required. (100l/w , 5700K Cool white, rated voltage- 220/240V. (LM 79 and LM 80 reports need to be submitted , 50,000 burning hrs, and two years warranty) Make:-Havells/Philips/Bajaj/ Jaquar. Make 0f LED Philips/Osram/Cree/Nichia.
12 W Round Down light Surface/Recess
15/16 W Round Down light Recess/Recess
2' x 2' LED Panel Light (600mmx600mm) 36W
SITC of following rating surface mounted LED Batten tube light fitting suitable for 230V, 50 Hz, single phase supply etc all complete as required. wall mounted LED type batten fitting complete with electronic diver and LED etc. directly on wall including connections with 1.5 Sq. mm FR PVC insulatted copper conductor and earthing the body etc. as requiered. (with running life minimum 30000 hrs) Make:-Havells/Philips/ Wipro/ Jaquar
8/10W LED Tube Light (2 FT) Tube Light .
20/22 W LED Tube Light (4 FT) Tube Light.
All the LED lamp shall be of minimum 60 or above lumens per watt and the LED BATTEN TUBE LIGHTS & other LED light fixtures shall be of 100 or above lumens per watt. LM 79 and LM 80 reports need to be submitted ). Make:-Havells/Philips/ Wipro/ Jaquar . Make 0f LED Philips/Osram/Cree/Nichia.
Supply of 9W/10W LED Bulb in existing holders.(Confirming to IEC: 62722)
Supply of double LED Tube light Fitting made of diacast aluminium housing 2x20W LED Bettle Tube light sritable for surface or suspended mounded suitable for 230V, 50 Hz, single phase supply etc all complete as required, complete with electronic diver and LED etc., including connections with 1.5 Sq. mm FR PVC insulatted copper conductor and earthing the body etc. as requiered. Efficacy is 100 lm/W.temperature (5700K ± 355K. @L70 & Lumen maintenance as per L70 (Confirming to I.E.C. 62722)
Supplying and fixing Surface mounted 9/10 Watt CFL / LED type bulk head e comprising of pressure die casr housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc. directly on wall /ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc as required. LM 79 and LM 80 reports need to be submitted, 50,000 burning hrs, and two years warranty).
SITC of LED 2 ft Mirror light with power 8/10W, rated voltage 230W, 50 HZ, aluminium /PC body with running life minimum 30000 hrs. to use in Toilets above Mirror.
SITC of 2x8W LED outdoor UP-DOWN light with IP:65 protection, die cast aluminium housing. (LM 79 and LM 80 reports need to be submitted , 50,000 burning hrs,)
LED Street Light :- SITC of following rating LED Street Light luminarie with pressure die cast housing and loughened glass cover (IP-66 Protection) in existing pole /pipe for supply voltage 100- 270V, AC, 50Hz, . Luminarie shall be confirm to IS:- 10322 (Part-5/Section-3 and shall be complete with all necessary accessories as required. 90/100 W LED Street Light
LED FLOOD LIGHT:- SITC of following rating LED Flood Light luminarie with presure die- cast housings and loughened glass cover (IP-66 Protection) in existing pole /pipe for supply voltage 100- 270V, AC, 50Hz, . Luminarie shall be confirm to IS:- 10322 (Part-5/Section-3 and shall be complete with all necessary accessories as required. (200W/4000K) 200W LED FLOOD LIGHT (4000K)
Post Top LED Lamp (for Gate) SITC of following rating LED Post Top Lamp made in die- cast aluminiumn with Clear /Opal acrylic diffuser (IP-66 Protection) on existing including connection with 3x 1.5 Sq. mm PVC Copper conductor etc all complete as required. 40/45 LED POST TOP Lamp (clear)
LED Bollard Fitting :- SITC of following rating approved make LED Bollard fitting with cylindrical ssape of height 600 t0 850mm power in put 8/9 Watt die cast aluminium housing opel with PC diffuser , IP65/54 protection, confirming to IS:- 10322 part-5 etrc. Complete as required . (Excluding plinth charges.)
Supply fitting and fixing of PVC/XLPE insulated PVC sheathed heavy duty Al. armoured cable for working voltage up to and including1100 Volts confirming to IS 1554 (part-1) Make:- Havells, KEI, Finolex, Polycab.
2 Core 6 Sq. mm
4 Core 10 Sq. mm
3.5 Core 25 Sq. mm
3.5 Core 35 Sq. mm
3.5 Core 50 Sq. mm
3.5 Core 95 Sq. mm
3.5 Core 300 Sq. mm
20 KVA ON Line UPS (3 Ph. Input & 3 Ph. Output) With Accessories
Supply, fitting, fixing and testing of 1 no. 20 KVA in parallel redundant mode with SMF back-up batteries suitable for 30 minutes configuration with :- 415V, 3ph input & 3 ph output ON-LINE UPS system backup protection for 90 minutes and all standard accessories as required. The Inverter will have in built protection for ground fault, DC reverse polarity, DC over voltage and current limitation, AC short circuit, AC over Voltage and current limitation. The UPS technology should consists of high double-conversion efficiency IGBT Based rectifier on line type UPS.The details are as follows:-
Supply, fitting, fixing, testing and installation of 1 no. 20 KVA, ON Line UPS three phase input and three phase out put power system of in put voltage 360V/380/V/400V/485V AC , Frequency range 40 HZ to 60 Hz, +/- 10% and out put voltage range 415V +/-1%, AC frequency range, 50Hz, +/-1% poower factor 0,8/3.1, Harmonic distrortion -< 2% THD (Linear Load): 5% THD (Non- Liniear Load) along with required Batteries, Battery Stand, UPS Box Battery Lead etc as required. (30 minutes back up ). Technology:- True online double convertion confirming (VFI-SS-III); can be parallel in (N+ 1) configuration minimum 4 nos. . 24 months replacement guaranty in UPS. Service Center:- Local registered OEM own service centre should be required . Make UPS:- Numeric (Legrand), APC (Schneider), Vertive(Emersion)
Configuration of UPS :-
3 Phase input & 3 Phase output
The above mentioned on-line UPS must have following features
1) Upgradeability :- Suitable for paralleling up to 3 nos. of 20 KVA UPS, and Should be upgradable to work as parallel redundant UPS in load sharing mode.
2) Intelligent LCD display with event logging facility.
3) Double conversion.
4) Built in paralleling kit.
5) IGBT technology for Rectifier and Inverter.
6) Split Static, Manual & Maintenance Bypass.
7) Input power factor correction less than 0.95.
8) Input harmonic distortion less than 5% at 50% load. with the application of IGBT(Insulated Gate By polar Transistor) based rectifier, but 6/12 pulse is not applicable.
9) Software communication :- RJ-45 port to communicate with BMS and Should be SNMP (Simple Network Management protocol) compatibility.
10) Phase reverse sequence operation
11) Automatic static bypass
12) Maintenance Bypass.
13) Technology : Micro processor based controls, true online, double conversion type, should have cold start facility.
14) Overall minimum Efficiency :>93.8%
15) Isolation ;- Built inl isolation transformer at the output of UPS System.
16) Charger :- Should have built in charger of minimum 10 Amp. (separate from rectifier)
17) IGBT bith side input and inverter side
18) SNMP Kit card.
19) Parallel Redundant Kit. Overload:- ≤ 110% for 60min ≤ 125% for 10min ≤150% for 60 Sec
20) Input phase correction kit. Input:- Power Factor
21) Back-up time :- 30 min. with SMF Batteries.
Cost of 20 KVA ON LINE 3 Phase in and 3 Phase out UPS
SITC of MS Battery Rack suitable for 15 to 20 UPS Battery Installation.
SITC of 100Amp. DC Breaker with UV relay Coil. Make:- L&T, Siemens, Schneider, Legrand
SITC of 18 nos. 100 AH Sealed Maitanace Free (SMF) Battery with 24 months replacement guaranty. IS:1652:1991. (VAH Required 21600 for 20 KVA UPS (100AH x 18 Nos. x 12V = 21600 VAH) Make:- Battery-Exide, Amar-Raja, Quantum.
Total Cost of 1 Set 20 KVA UPS, Batteries & Accessories (A+B+C)
G.I. OCTOGONAL POLES
Supply of 7 Meter Height Octagonal Hot Dip Galvanized pole (BOP 7030) with top dia 70mm bottom dia 130mm & made of 3 mm thickj sheet, base plate dimensions 200x200x12mm (L X B X T) including suitable sizes of foundation bolts all complete as required. (Without ARM) Make:-VALMOUNT, TRANSRAIL,BAJAJ,/RR ISPAT..
Installation, Testing and commissioning of 7 Meter Height Octagonal Hot Dip Galvanized pole with suitable Tools and Plants, wiring of Luminaires with all materials and construction of shallow foundation, with M25 grade concrete considering safe soil bearing of 10T/mtrs Sq.
Supply fitting, fixing of Single Arm (1 Mtr. Long) suitable for 70 mm Top. Make:- VALMOUNT, TRANSRAIL,BAJAJ,/RR ISPAT..
Supplying and fixing of following switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd. Bell push
Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, C curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (to use as out going for Light VTPN DB) (Make:-LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200MSIEMENS- BETA GUARD/ L&T- AU VERSION). 25 A Triple Pole
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required.
2 Core 10 Sq. mm. (19mm)
3.5 Core 25 Sq. mm. (28mm)
3.5 Core 35 Sq. mm. (32mm)
3.5 Core 50 Sq. mm. (35mm)
3.5 Core 95 Sq. mm. (45mm)
3.5 Core 300 Sq. mm. (70mm)
4 Core 10 Sq. mm. (25mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
80 mm dia (CSR-2018)
100 mm dia (DSR-2022)
Supplying, fitting, fixing, connecting and testing of decorative double arm Wall Bracket Fixtures in nchrome finish in glass diffuser with 2x10Watt LED lamp directly on wall including connection with 1.5 sq mm FR PVC insulated copper conductor cable and eathing the body etc. as required. (Decorative Wall Bracket should of Best Quality after the approval of E/I) Make:- Philips, Jaquar Havells.
MAIN LT PANEL FLOOR MOUNT FOR J.S.E.R.C. OFFICE BDG. (Location in GR. Floor Electrical Panel Room )
Supplying, designing, manufacturing, installation, shifting to location, testing and commissioning in correct alignment position, effecting proper connection of all incomer and outgoing feeders of Wall/Floor Mount LT Panel, fabricated out of 2mm thick (14SWG) CRCA sheet steel, dust and vermin proof with reinforcement of suitable size iron channel, size 50mm x 50mm x 6mm with proper lifting arrangement, (IP-42) fully compartmentalized cubical type (folded joints construction), totally enclosed LT Panel and suitable for use on 415V, 3 phase, AC Supply, 4 wire, 50 C/S, system having 36 KA fault capacity, housed with incoming and outgoing aluminum bus bars, interconnection, interlocking between feeders etc. with indicating lamps, push buttons, necessary accessories, all out going feeders protection & meters as required.
The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs.
Main LT Panel shall have 20% spare outgoing feeders for different rating of feeders. The Panels shall be preferably arranged in multitier formation. The size of the panel shall be designed in such a way that the internal space is sufficient for hot air movement, and the electrical component do not attain temperature rise more than 40 degree Celsius.
The LT Panel shall be totally enclosed, completely dust and vermin proof. Synthetic rubber gaskets (neoprene/DPDM) between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be fully gasketed and shall be lockable. Doors shall have concealed hinges. All the doors shall be suitably reinforced by channel to provide rigidity. Panel shall have suitable cable entry from bottom and suitable arrangement for aluminum cable termination.
The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 6/16A socket with sitch as service outlet (single phase) and 1 no. 10W LED LAMP with holder shall be provided in one of the compartments as service outlet in the panel. The complete panel shall be fuse less type, for control circuits 2A SP MCB's to be used.
Panel Builder will provide shop drawing SLD & GA drawing along with BOM with CAT. No. of each and every components and switch gears of LT Panel for approval of Consultant. Panel Builder shall visit the site before manufacturing the Panel. Inspection of the Panel shall be carried out at Panel Builder's factory by the Consultant before final delivery for that all arrangements shall be made by the contractor.
Location :- Location in Basement Floor Electric Room.
The Name Plate for each feeder must be in Anodized Aluminium Sheet.
Make of MCCB - L&T D-Sine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL.
Make of MCB - (10kA-C-Series.) L&T U Version/ Legrand-Dx³/ Schneider-Acti / Siemens.-Bita Guard
Make of On Load Change Over :- L&T , Sucomo, Legrand.
Size of incoming cable:- 2R 3.5C 300 Sq.mm. Al. Ar. Cable.
Panel Size - As per approved Drawing.
All 4 pole MCCB with thermomagnetic based release must have follwing characterstics:-
1. Icu=100% Ics.
2. With positive Isolation Marked.
3. With adjustable short circuit and over load.
4. As per IEC 60947-2.
AL. BUS BAR
The panel includes 415V, 800A, 3Ph, 36KA, 50Hz, TPN Electrolytic Aluminium Bus Bar (E91E) GI Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. Minimum clearance between live parts / neutral to earth shall be 19mm. However clearances between terminals at components shall be as per applicable individual standard for components. Interconnections between the main bus bars and individual units shall be made using vertical / horizontal Bus Bar to individual MCB shall be made with 4, 6 & 10 Sq mm FRLS PVC Cu. wire with 63A 4 studs (Brass) treminal block, aluminium bus bars of adequate rating. AL. Bus Bar will be supported on insulators made of non-hygroscopic, non-inflammable material with tracking index equal to or more than that defined in BIS.
Bill of Material of Main LT PANEL:-
1 Set Of Fabrication part of LT Panel & busbar system, in CRCA Sheet Steel enclosure (IP-42) without any components & its busbar system, in CRCA Sheet Steel enclosure without any components. Name of Panel Builder :- JMD ELECTROTECH, KOKAR, STECT POWER INDUSTRIES, BIT, Mesra, Arnav Power tech, Ranchi. TTS Systematix Private Ltd, Tatisiway, Meditron, Meshra, Ranchi or any approved Panel Builders of above make Switch Gears.Set
INDICATING
1 Set Multifunction Meter having (5010 Series) LED mete display accuracy Class 1 as per IEC 62053-21, should have an active RS-485 port, in built RTC, Aux Supply: 44-277Vac/dc. Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, Onhrs Interrupts, THD for V&I per phase, individual harmonics for V&I upto 15th level complying with IEC61557-12. Min/Max for eight parameters. Sampling rate: 64 samples per cycle. Each
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer & outgoing. Set
3 nos. CT of appropriate power as per incomer /5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa / Matrix/Rishabh. Set
INCOMER :-
1 No.630 A F/P MCCB (36kA) with adjustable thermomagnetc release type with S/C & O/L protection, With ON-OFF- Indication and front extended rotary Handle and spreader links in both end (Incoming cable size –2 Run 300 Sq mm 3.5 Core Al. Ar. Cable). Set
Out Going Feeders Without DG Set
2 Nos. 160 A FP MCCB (25KA) with thermomagnetic release type with S/C & O/L protection with front rotary handle with spreader links. ( 1 no. For APFC Panel & 1 no. For Panel for AIR CONDITIOING SYSTEM) Cable Size 3.5 C 95 Sq.mm Al,Azr, Cable) Each
4 Nos. 100 A FP MCCB (25KA) with thermomagnetic release type with S/C & O/L protection with front rotary handle with spreader links. ( For 3 nos. Power VTPN DB) & 1 no. As spare. Cable Size 3.5 C 50 Sq.mm Al,Azr, Cable) Each
2 Nos. 63 A FP MCCB (25KA) with thermomagnetic release type with S/C & O/L protection with front rotary handle with spreader links. (1 nos. for out door Feeder Pillar for external lighting & 1 no. ss spare. Each
1 Nos. 25 A FP MCCB (25KA) with thermomagnetic release type with S/C & O/L protection with front rotary handle type with spreader links. (1 Nos. as spare )
Out Going Feeders With DG Set
Provision of Mechnical interlocking between 250A/FP/25KA MCCB as common incoming and 1 No. of 250A on load Change over for D.G incomer, in such a way so that the two supplies are not parallel at any time.
1 No. 250A/FP/25KA/ MCCB thermomagnetic release type, and S/C, O/L protection, with Rotary Handle & Spreader links. Each
7 Nos. 63 A FP MCCB (25KA) with thermomagnetic release type with S/C & O/L protection with front rotary handle type with spreader links. (3 nos. for Light VTPN DB, & 2 no. For Passenger's Lift, 1 no. For UPS, 1 no. For Fire Fighting Panel & 1 no. As spare) Each
2 Nos. 25 A FP MCCB (25KA) with thermomagnetic release type with S/C & O/L protection with front rotary handle type with spreader links. (2 nos. as spare ) Each
4 nos. 32 A DP MCB C Seires 10kA (2 nos. for Submersible pum Motor & 2 nos. as spare) Each
Total Cost of Main LT Panel
A.P.F.C. Panel (Capacitor Bank) Auto Mannual Type
A.P.F.C. Panel (Capacitor Bank) Auto Mannual Type (APFC) Panel – 115 KVAR 8 Stage Capacitor Bank Details with mixed dielectric Ultra Heavy Duty Capacitors of following range and 1 Set 15 KVAR (2x7.5 KVAR) fixed Capacitor bank to take care of no load losses of Transformer :-
Supplying, designing and manufacturing in correct alignment position, un loading at site, shifting to location, effecting proper connection of all incomer and outgoing of A.P.F.C. Panel (Capacitor Bank / Auto Mannual), testing of the same made of 2 mm CRCA sheet (14 SWG) steel IP –42 floor mounting dust and vermin proof cubical type Capacitor Bank Panel suitable for operation on 415V, 50Hz, 3 Ph. AC supply and fault level 50kA with front operated construction including separate fabrication arrangement for fixing MCCB, , M.C.B., Capacitors, Contactors etc.
The 2 mm sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized with locking arrangement duly fixed on Base Channel with proper lifting arrangement size – 50 mm x 50 mm x 4 mm having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs and Capacitors having earthing arrangement.
All openings shall be covered by soft rubber gasket, enclosure shall be galvanized.
Aluminum Bus Bar for Panel :-
Bus bar shall be suitable for 250A, TPN busbar chamber of suitable length with (E91EWP) Eletrolytic Aluminum busbars. All busbars and interconnections shall be of suitable size Aluminum busbar, current density of Aluminum shall not be more than 0.8 Amps/sq.mm cross sectional area of Bus Bar with removel gland plates, cable glands, at sending and receiving ends, encluding connections with outgoing feeders complete in all respect and all interconnections shall be made with 2.5, 4 and 6 sq.mm. PVC Cu.wire. The Aluminium bus bar shall be with heat shrinkable PVC Slived Red,Yellow,Blue & Black as (RYB & N ) after temperature and incloser derating maximum allowable temp.of bus bar shall be 90 degree C
Panel Size - As per Drawing and shall be provided at the time of work order.
Panel Builder will provide shop drawing SLD & GA drawing along with BOM with CAT. No. of each and every components and switch gears of APFC Panel for approval of Consultant. Panel Builder shall visit the site before manufacturing the Panel. Inspection of the Panel shall be carried out at Panel Builder's factory by the Consultant before final delivery for that all arrangements shall be made by the panel Builder.
The Name Plate for each feeder must be in Anodized Aluminium Sheet.
The Panel Builder must be CPRI approved. Panel builder must produce test certificate for Type Tested & Short Ckt withstand capacity as per IEC-60439-II from CPRI.
1 Set Of Fabrication part of LT Panel & busbar system, in CRCA Sheet Steel enclosure (IP-42) without any components & its busbar system, in CRCA Sheet Steel enclosure without any components. Name of Panel Builder :- JMD ELECTROTECH, KOKAR, STECT POWER INDUSTRIES, BIT, Mesra, Arnav PowerTech, Ranchi TTS Systematix Private Ltd, Tatisiway, Meditron, Meshra, Ranchi or any approved Panel Builders of above make Switch Gears. Set
Location : Panel Room.
Make of MCCB - L&T D-Sine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL.
Make of MCB - (10kA-C-Series.) L&T U Version/ Legrand-Dx³/ Schneider-Acti / Siemens.-Bita Guard
Location :- Location in Basement Floor Electric Room.
The Name Plate for each feeder must be in Anodized Aluminium Sheet.
Panel Size - As per approved Drawing.
Bill of Material in A.P.F.C.R. Panel :-
2 Nos. 63A TP / MCB / 10kA (D tripping characteristic) for 25 KVAR Capacitor. Each
2 Nos. 40A TP / MCB / 10kA (D tripping characteristic) for 20 KVAR Capacitor. Each
2 Nos. 16A TP / MCB / 10kA (D tripping characteristic) for 7.5 KVAR Capacitor. Each
2 Nos. 10A TP / MCB / 10kA (D tripping characteristic) for 5 KVAR Capacitor. Each
Incomer
1 No. 160 A FP MCCB (25KA) with thermomagnetic release type with S/C & O/L protection with front rotary handle type with spreader links. ( For APFC Panel) Cable Size 3.5 C 95 Sq.mm Al,Azr, Cable) Each
Indication:-
16 Nos. LED Indicators sets (220V) (R – 8/ G – 8 = 16 Nos.) self illuminated Red-Green (ON-OFF) push buttons, each backed up with Push Button (Red- Yellow) shall be provided for each capacitor unit to indicate the status of the unit. Make-L& T./ AE/ Rishabh. Set
3 Nos. LED indicatore (R Y-& B) of 220V. with 2A SP MCB protection. Make- Legrand / L&T / Rishabh ) Each
3 Set CT 200/5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa / Matrix / L&T. Set
3 Nos. 16A – 2 pole / 2 way Rotary Switch. Make:- Reputed. Each
8 Nos. 10A Toggle Switch SP – HT Make:- Reputed. Each
1 Set Power factor correction Intelligent controller Relay with 8 steps and multi -functional display, APFCR with 8 steps. The relay shall be sensitive to pick up 1% of rated current and correct the P.F accordingly. Also the relay shall display the harmonic level of system. Make- L&T, Seimens. Each
1 Set VAF + Power Factor, 3Ph, Class 1, 5A, Meter Make- L&T / Seimens / Scheneider. Each
The capacitors for Auto Mannual Type (APFC) Panel – 115 KVAR 8 Stage Capacitor Bank Details with following parameters:- (BOX SERIES OF 440V)
1. MPPXL ,440V/50Hz,TP Shunt mixed dielectric heavy duty Capacitor.
2 Lower operating losses - 0.35W/KVAr).
3. Over current withstand capability - 1.8 times rated current.
4. Inrush current withstand capability - 300 times rated current.
5. Operating Life- 130000 hours.
6. Numbering of switching- 8000 operations per year.
7. Insulation Class H.
Mixed dielectric Ultra Heavy Duty Power Resin filled Capacitor Make:- Legrand/ L&T / Schneider -Meher
2 Nos. 25 KVAR (Power Capacitor) Ultra Heavy Duty. p/kvar
2 Nos. 20 KVAR (Power Capacitor) Ultra Heavy Duty. p/kvar
2 Nos. 7.5 KVAR (Power Capacitor) Ultra Heavy Duty. p/kvar
2 Nos. 5 KVAR (Power Capacitor) Ultra Heavy Duty. p/kvar
Total - 115 KVAR.
Capacitor Duty Contactors :- (NO/NC) Make:-Seimens / L&T.
2 Nos. For 25 KVAR – MOC 25 1NO & 1 NC (63A) (Suitable for 25 KVAR capacitor bank). Each
2 Nos. For 20 KVAR – MOC 20 1NO & 1 NC (40A) (Suitable for 20 KVAR capacitor bank). Each
2 Nos. For 7.5 KVAR – MOC 15 1NO & 1 NC (16A) (Suitable for 7.5 KVAR capacitor bank). Each
2 Nos. For 5 KVAR – MOC 15 1NO & 1 NC (10A) (Suitable for 5 KVAR capacitor bank). Each
2 Sets (7.5 x 2) = 15 KVAR fixed Capacitor Bank with all required accessories like capacitor duty contactor (For each 7.5 KVAR –MOC 8.5 1NO & 1 NC (16A),) each capacitor shall with 16A TP / MCB / 10kA (D tripping characteristic) R & Y indicators, toggle switch etc. shall be fixed capacitor to take care of the no load losses of the transformer. (1 Set) Set
Total Cost of 115 KVAR APFCR Panel with 15 KVAR (7.5 x 2) as Fixed Capacitor Bank.
Out Door External Lighting Panel (Feeder Pillar):-
Supply, manufacturing and effecting proper connection of all incomer and outgoing, unloading at site, shifting tolocation, fitting, fixing and testing of the of out door canopy type double door Feeder Pillar fabricated out 2 mm (14 SWG) CRCA Sheet steel dust, damp, vermin and water proof (IP-55) free floor standing factory built sheet steel enclosed modular construction extendable panel, suitable for operatrion on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted (powder coated) complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required.
The sheet steel under go minimum 7 tanks treatment followed by finishing of powder coating of minimum 60 micron thickness, duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 Nos. earth studs.
The LT Panel shall be totally enclosed, completely dust and vermin proof. Synthetic rubber gaskets (neoprene/DPDM) between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be fully gasketed and shall be lockable. Doors shall have concealed hinges. All the doors shall be suitably reinforced by channel to provide rigidity. Panel shall have suitable cable entry from bottom and suitable arrangement for aluminum cable termination.
The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 6/16A socket with sitch as service outlet (single phase) and 1 no. 10W LED LAMP with holder shall be provided in one of the compartments as service outlet in the panel. The complete panel shall be fuse less type, for control circuits 2A SP MCB's to be used.
The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 6/16A socket with sitch as service outlet (single phase) and 1 no. 10W LED LAMP with holder shall be provided in one of the compartments as service outlet in the panel. The complete panel shall be fuse less type, for control circuits 2A SP MCB's to be used.
Panel Builder will provide shop drawing SLD & GA drawing along with BOM with CAT. No. of each and every components and switch gears of LT Panel for approval of Consultant. Panel Builder shall visit the site before manufacturing the Panel. Inspection of the Panel shall be carried out at Panel Builder's factory by the Consultant before final delivery for that all arrangements shall be made by the contractor.
Location :- Location in Basement Floor Electric Room.
The Name Plate for each feeder must be in Anodized Aluminium Sheet.
Make of MCCB - L&T D-Sine/ Legrand DPX³ / Schneider-NSX / Siemens - 3VL.
Make of MCB - (10kA-C-Series.) L&T U Version/ Legrand-Dx³/ Schneider-Acti / Siemens.-Bita Guard
Make of Modular Change Over :- L&T , Schneider, Legrand.
Panel Size - As per approved Drawing.
All 4 pole MCCB with thermomagnetic based release must have follwing characterstics:-
1. Icu=100% Ics.
2. With positive Isolation Marked.
3. With adjustable short circuit and over load.
4. As per IEC 60947-2.
AL. BUS BAR
The panel includes 415V, 100A, 3Ph, 36KA, 50Hz, TPN Electrolytic Aluminium Bus Bar (E91E) GI Earth Bus with removable glands plates, cable glands at sending and receiving ends, including connection with outgoing feeders complete in all respects. The electrolytic Aluminium bus bar as per I:S 5082 of suitable length and insulated by heat shrinkable sleeves Red, yellow, Blue and Black as R Y B & N. The current density of bus bar shall be minimum 0.8 A / sq mm. Minimum clearance between live parts / neutral to earth shall be 19mm. However clearances between terminals at components shall be as per applicable individual standard for components. Interconnections between the main bus bars and individual units shall be made using vertical / horizontal Bus Bar to individual MCB shall be made with 1.5, 2.5 Sq mm FRLS PVC Cu. wire with 63A 4 studs (Brass) treminal block, aluminium bus bars of adequate rating. AL. Bus Bar will be supported on insulators made of non-hygroscopic, non-inflammable material with tracking index equal to or more than that defined in BIS.
Bill of Material of Main LT PANEL:-
1 Set Of Fabrication part of LT Panel & busbar system, in CRCA Sheet Steel enclosure (IP-42) without any components & its busbar system, in CRCA Sheet Steel enclosure without any components. Name of Panel Builder :- JMD ELECTROTECH, KOKAR, STECT POWER INDUSTRIES, BIT, Mesra, Arnav Power Tech, Ranchi, TTS Systematix Private Ltd, Tatisiway, Meditron, Meshra, Ranchi or any approved Panel Builders of above make Switch Gears. Set
INDICATING
1 Set Multifunction Meter having (5010 Series) LED mete display accuracy Class 1 as per IEC 62053-21, should have an active RS-485 port, in built RTC, Aux Supply: 44-277Vac/dc. Parameters: Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs, Onhrs Interrupts, THD for V&I per phase, individual harmonics for V&I upto 15th level complying with IEC61557-12. Min/Max for eight parameters. Sampling rate: 64 samples per cycle. Each
3 Sets Phase indicating light shall be protected by 2 Amps SP MCB's for incomer & outgoing. Set
3 nos. CT of appropriate power as per incomer /5VA -5 class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:-Kappa / Matrix/Rishabh. Set
INCOMER:-
1 No.63A F/P MCCB (25kA) with adjustable thermomagnetc release type with S/C & O/L protection, and front extended rotary Handle and spreader links in both end. Set
OUT GOING
OUT- GOING
3 nos. 25A/FP/25KA/ MCCB thermomagnetic release type, on of trip and S/C , O/L protection, with Rotary Handle & Spreader links. Each
2 nos. Power Contactor 40A NO NC of three phase of suitable rating. Each
2 nos. Astronomical Alpha Rex³ single channel Timer 24 hrs. Each
2 nos. Four pole two way Lexic changeover with centre off 440V AC 40A to be used in case of timer failure to by pass the timer. Each
2 nos. 63A DP MCB C Series of 10 kA Each
2 nos. 32A DP MCB C Series of 10 kA Each
Total Cost of External Feeder Pillar Panel
SITC oif 63 A TP MCB 'C' Series 10 kA to use as out going for Power VTPN DB (Make:-LEGRAND- DX³/SCHNEIDER- ACTI-9/ABB-S200MSIEMENS- BETA GUARD/ L&T- AU VERSION).
SAFETY ITEMS
Supplying & Laying 12mm thick chequered rubber matting of 1.1.kv 1x1 m) (L&W) of tested quality to with stand 15KV dielectric strenght of approved make as per IS-5424-1969.
Supplying of fire buckets of 10 liters Capacity of approved quality, painted white from inside and red outside and having inscription "FIRE" in white conforming to I.S. 2546/1974 duly amended upto date complete as required & approved by Engineer Incharge.
Supplying and fixing of MS pedestal stand heavy duty with rain protection cover as required suitable for supporting three fire buckets as required for fire fighting system & approved by Engineer Incharge.
Supplying and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15683 with cylinder duly charged of capacity 4.5kgs. including fixing clamps, brackets, bolts and nuts etc. as required & approved by the Engineer Incharge.
Supply and fixing of shock treatment/ restoration charts written in Hindi/ local language and English duly framed and covered with 3.0 mm glass as required.
Supply of First Aid Box made of 16 SWG MS Sheet duly painted within inside and outside surfaces with one coat of primer and two coats of synthetic paint of required shade comprising the following minimum but not limited, minimum 1 No. band aid bandage 150mm, 1 No. Savlon Soap 30 ml, 1 No bottle Betadine 30 ml, 1 No Packet dressing material etc. as required, approved by Indian Red Cross / St. John's conforming to IS:2217.
Supply of 440V grade Rubber Hands Gloves. As per IS:4770- 1991.
Supply and fixing position the approved single line diagram framed in 1000 x 800 mm size glass frame and installed in main switch room.
Providing, fitting, fixing, fabricating, erecting of MS angle of section 50 mm x 50 mm x 6 mm size for Brick wall trench to make support for MS iron plate to be fixed on every after 300 mm in RCC trench.
Providing, fitting, fixing, fabricating, erecting of MS Plate of 2'X2 (12 mm) thick' for covering Brick wall cable trench in panel room on the support of iron angle each piece of MS plate shall be 450 mm (D) x 450 mm (W). (To cover the Brick wall cable trench in panel room.)
SOLAR ALL-IN-ONE SOLAR STREET LIGHTING with Hybrid Switch
Providing, Fitting fixing and testing of 12 V DC 30 W with hybrid Switch Smart integrated Solar All in one Street light with built in Mono Crystalline Panel, Battery- Lithium Ferro Phosphate, in built BMS, LiFePo4, with Integrated MPPT Solar Charger Controller, dimming profile and PIR Sensor with Colour temp. 6000-6500K System efficiency 125lm/W Warranty 3 Yrs against manufacturing defect with Front Cover UV stabilized Polycarbonate LED . @ L70 Battery Capacity>150 to 170Wh, Three days back up recommended pole height 4 to 5 Mtrs. pole (cost of solar street light inclusive of copper cable, UPVC pipe, burried trench etc.) As per approved make list. (Cost of Solar Street Light is exclusive of 6 mtr. poles.) . All Hybrid Solar Street Lights shall be also conncected through grid by laying 4 core 16 sq mm Al. Ar. cable.
Other Protectiion:- a. Over-Charge protection b. deep-discharge protection c. Over current protection d. Short circuit protection e. Over voltage protection
Supply and erection of 5 metre height Hot-dip galvanized octagonal solar street light pole with single arm (1000mm) with following arm with top dia 70 mm and bottom dia A/F 155 mm, made of 3 mm thick sheet along with base plate of size 260 X 260 X 16 mm , small door opening for junction box mounting with MCB & connector, cement concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete job as required. (but without pole collar)
Total Cost of 12 V DC 30 W with 5 mtr hot Dip Galvanized Octagonal pole.(a+b)
Supply, Installation, Testing and Commissioning of electric driven, centrifugal type, single/multistage, end suction type, centrifugal pump of cast iron body, C.I impallers with carbon steel shaft & mechanical seal directely coupled with TEFC SQ cage foot mounted type induction motors suiitable for operation on 3 phase, 415 volts 50 Hz AC with IP 55 Protection for enclosure, horizontall foot mounted with class F insulation , complete in all respect as required or as directed by engineer incharge.
Main Fire Pump
Jockey Pump
Terrace Booster Pump
Fabrication, Supplying, Installation, Testing & Commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 V, 3 phase 50 HZ AC supply with enclosure protection class IP 42.
For Pump Room
For Terrace Pump
Supply and fixing of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes including making end termination with compression gland & bimetalic lugs, and support etc.complete as required
3 × 50 sq.mm.(aluminium)
3 × 6 sq.mm.(aluminium)
2 × 1.5 sq.mm. in Conduit
Providing and fixing IS marked Gate Valve / Foot Valve (incase of -ve suction) complete with companion flanges, bolts, nuts, rubber insetions etc.
150 mm diameter
Providing and fixing IS marked butterfly valve (PN 1.6) complete with companion flanges, bolts, nuts, rubber insetions etc.
65 mm diameter
80 mm diameter
100 mm diameter
150 mm diameter
Providing and fixing check valve (NRV) complete with companion flanges, bolts, nuts, rubber insetions etc.
80 mm diameter
100 mm diameter
150 mm diameter
Providing and fixing Strainer (Y-Type) complete with companion flanges, bolts, nuts, rubber insetions etc.
100 mm diameter
Pressure Gauge Assemble with Gate/Ball Valve
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Air release Valve / Drain Valve
MS Structure support for piping
Providing, laying, testing & commissioning of IS 1239 marked black M.S pipe including all fittings i.e bend, elbows, tees, flanges, reducing socket, nuts and bolts, gaskets etc fixed with welded / screwed joints. including necessary excavation, backfilling, removal of surplus soil etc. min. 1 mtr deep excavation and wrapping with anticorrosive treatement with 4 mm thick asphalt tape as per IS:10221, refilling the trench etc. OR fixed with screwed or welded joints, hanged with clamps, hanger supports, dash fasteners, bolts, nuts, rubber insertions etc including threading, cutting, welding, edge preparation, painting of approved colour over two coat of primer, cutting & making good the wall/ floor wherever required, complete as required or as directed by engineer incharge.
150 mm diameter
100 mm diameter
80 mm diameter
25 mm diameter
Providing and fixing S.S Fire Hydrant Valve of approved quality with 63 mm female, instant, ovlique, single outlet, 80 mm flanged inlet, brass spindle, cast iron wheel m A.B.S. blank cap and chain. conforming to IS: 5290 complete with companion flange, bolts, nuts, rubber insertion / compressed asbestos gasket etc. and painted in fire red colour.
Providing and fixing swinging, wall mounting type First Aid Hose Reel of approved quality and made from compresed steel sheet with dust cover, cast iron brackets including 30 m long, 19 mm nominal bore, high presure braided rubber hose as per IS:444 Type hose guide, PVC shut off nozzle with 6 mm outlet and 25 mm nominal bore gun metal inlet valve, bolts, nuts rubber insetion etc. painted in Fire red colour including cutting and making good the walls wherver required.
Providing and fixing 25 / 15 mm nominal gun metal gate valve class I with CI wheel of approved quality with union (Screwed end)
Providing and fixing in position 63 mm nominal bore and 15 m long synthetic fibre, CP fire hose pipe of approved make bearing IS: 636 -1988 type A mark and having TAC and MMD approved with a pair of 63 x 63 mm gun metal instantaneous type, heavy duty delivery hose coupling (conforming to IS: 903) bound and riveted to the hose pipe with copper rivets and copper wire complete.
Providing and fixing in position short SS brach pipe of approved quality with 63 mm male instatneous type inlet and 15 mm outlet nozzle complete conforming to IS : 903
Supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick M.S. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect.
Supplying, fixing, testing & commissioning of 1 set of 63mm two way instantaneous fire brigade connection (FBC) with inbuilt NRV comprising of SS and four SS instantaneous male inlet coupling confirming to IS:604 with plug and cap with chain as required with nut & bolts, washers, high pressure gasket as required.
Providing , fixing Dry Chemical Powder (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 20oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (4 Kg Capacity)
Carbon Di-oxide Type , Gas Confirming to IS ‘15222’ , Cylinder Confirming to ‘IS 7285’ & PESO approved ,Controllable Discharge Mechanism, Discharge Hose & Horn As per ‘IS 15683’ & ‘IS 2878’ ISI mark Fire Extinguishers (Wheel Type or Squeeze Grip Type). Operating Temperature :- (-)20oC to (+)55oC Suitable for ‘B’ ‘C’ Class of FIRE (4.5 Kg Capacity)
Providing , fixing Modular type Fire Extinguishers for electrical rooms (Stored Pressure Type) Mono Ammonium Phosphate 50% powder confirming to ‘IS 14609’ , Nitrogen Pressurized, Controllable Discharge Mechanism, Pressure Gauge, Discharge Hose & Nozzle Epoxy Polyester Powder Coated As per ‘IS 15683’ ISI mark Fire Extinguishers. Operating Temperature: - (-) 10oC to (+) 55oC Suitable for ‘A’ ‘B’ ‘C’ Class of FIRE complete in all respects (5 Kg Capacity)
Supplying, installation, testing and commissioning of optical type Smoke detector and mounting base with LED light complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed having two LED with cover complete with all connections etc as required
Supplying, installation, testing and commissioning of duel tone electronic hooter / Flasher / Strobe suitable for wall mounted complete as required.
Supplying, installation, testing and commissioning of manual call box in suitable enclosure with arrangement to raise the alarm when the glass is manually broken complete as required.
Supplying, installation, testing and commissioning of microprocess base main fire alarm control panel with LCD Display lights. The panels shall have 240 volts AC power supply automatic Battery charger 24 Volts sealed lead acid maintenance free battries as complete with batteries, battery charger illuminated numeric digram complete as required.
Providing and laying Cables for Fire alarm and PA System , 2 core x 1.5 sq mm armoured cables in surface , or flexible cables in PVC conduit (for conduits placed in ceiling).
Supplying, installation, testing and commissioning of PA Controller of atleast 6 Zones with USB and music player, complete as required.
Supplying, installation, testing & commissioning of celing / wall mount speakers of atelast 2 Watts with cover complete with all connections etc as required
Supplying, installation, testing & commissioning of PA amplifier of atelast 75 Watts with all accessories and required cables complete with all connections etc as required
Supplying, installation, testing & commissioning of PA announcement console (microphone) with all accessories and required cables complete with all connections etc as required
Add 18% GST
Add 1% Labour cess 1%
M/s N. K. Enterprises
ARUN KUMAR
Rhea Enterprises
Madan Lal Bajaj Construction Pvt. Ltd.
M/S Ram Pravesh Singh
BATHWAL TRADECOM PVT. LTD.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .