| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | ₹31.9 L Quoted ₹32.8 L | L1 | Accepted-AOC Accepted as L1 |
| 2 | L2₹34.0 LRejected-AOC | ₹34.0 L | L2 | Rejected-AOC other than L1 |
| 3 | L3₹34.3 LRejected-AOC | ₹34.3 L | L3 | Rejected-AOC other than L1 |
| 4 | L4₹35.8 LRejected-AOC | ₹35.8 L | L4 | Rejected-AOC other than L1 |
| 5 | L5₹35.9 LRejected-AOC R O BHARDA KALAN P O TEH AKHNOOR PIN 181201 DISTT JAMMU J K | JAMMU | JAMMU AND KASHMIR | 181201 | ₹35.9 L | L5 | Rejected-AOC other than L1 |
| Sl No | Description | Qty | Unit | M/s Rajesh Kumar Contractor L3 | M/s Vishwakarma Enterprises L1 | ASIA ENTERPRISES L8 | Ankush Gupta L4 | M/S JEEVAN LAL SHARMA L5 | M/s Chopra Constructions L7 | M/S KARAN SINGH CONTRACTOR L2 | bushan kumar L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition / taking down of existing old tarfelt , water proofing membrane, water proofing plaster of any description any type over RCC roof including any roof tiles, cement mortar screed, concrete screed of any thickness, to receive plaster and disposing off the debris out side MoD land complete all as specified and as directed. | 695 | Sqm | 50 ₹34,750 | 10 ₹6,950 | 30 ₹20,850 | 5 ₹3,475 | 15 ₹10,425 | 4 ₹2,780 | 50 ₹34,750 | 5 ₹3,475 |
| 2.00 | Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound on fair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra cement ) all as specified and directed.( Water proof compound shall be paid separately) | 695 | Sqm | 140 ₹97,300 | 60 ₹41,700 | 100 ₹69,500 | 100 ₹69,500 | 95 ₹66,025 | 80 ₹55,600 | 100 ₹69,500 | 150 ₹1.0 L |
| 3.00 | Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement) all as specified and as directed. | 33 | Per ltr | 40 ₹1,320 | 10 ₹330 | 100 ₹3,300 | 30 ₹990 | 50 ₹1,650 | 15 ₹495 | 60 ₹1,980 | 100 ₹3,300 |
| 4.00 | Roof treatment :- (a) Apply a coat of bituminous primer conforming to IS - 3384 @ 0.40 Kg/Sqm on prepared surfaces. (b) After drying of primer apply a coat of hot blown 85/25 penetration grade blown bitumen conforming to (IS-702 @ 1.20 Kg/Sqm of surfaces. (c) Provide APP modified polymeric five layed membrane with central core of 100 micron high molecular high density film. Minimum weight of APP modified water proofing membrane shall be 3 Kg per Sqm. Product Name Multi p[lus manufactured by M/S STP texa Ltd Gurgoan/Hyper Plus Standard Manufactured by IWL India ltd Chennai, Bengal Acquaflux manufactured by Bengal bitumen New Delhi/Superior plus 310 by STP Lfd and any other product as appproved by E-in-C Br will be used. APP membranne will be laid across the slop from lowest line of slopping roof toward ridge with minimum end lap of 150mm and side lap of 75mm bonded with hot blown. (d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as perIS 1203 will not be more than 40/Confiming to IS 702 @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bvitumen coat. (e) Coved fillet in PCC (1:2:4) type BO radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall around opening and treatment mentioned above (except fine sand) shall be applied followed by a cement plaster 20mm thick in CM 1:6. (f) If Non accessible roof:-After providing (a) to (d) provide aluminium paint as per manufacturer instruction. | 695 | Sqm | 390 ₹2.7 L | 400 ₹2.8 L | 300 ₹2.1 L | 310 ₹2.2 L | 505 ₹3.5 L | 415 ₹2.9 L | 450 ₹3.1 L | 500 ₹3.5 L |
| 5.00 | Sunken Floor treatment :- Providing and laying of water proofing treatment to sunken portion by applying cement slurry mixed with acralic based polymer modified cementitious composite compound of make as approved including demolition and filling of sunken floor by PCC 1:5:10 (Using aggregate).
(a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours.
(b) Second layer of slurry of cement Q 0.242 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/ Sqm his layer allowed to air cure for 4 Hours.
Note :- 1. Concrete for sunken slabs shall be mixed with WP compounds as manufacturdrs instructions before carrying out water proofing treatment the sunken slab slab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested ( Water proof compound rate is superatly.
2. 50mm thick PCC at the bottom of slab and slope shall be 1:20 toward the corner of outer wall and GI pipe of 50mm dia (Med grade) be inserted at corner projecting outside 20 cm .
3. 15 mm plaster mised with WP Compound shall be provided while concrete is green
4. Only floor area shall be measured for payment purpose. | 32 | Sqm | 800 ₹25,600 | 1,600 ₹51,200 | 1,000 ₹32,000 | 1,500 ₹48,000 | 570 ₹18,240 | 850 ₹27,200 | 550 ₹17,600 | 1,200 ₹38,400 |
| 6.00 | Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with water proofing liquid as per manufacturer's instructions as in copings, roof kerb etc including weathering, slighlty rounded or chamfered angles and throating etc complete all as specified and directed. (water proofing liquid to be measured and paid separately under relevant item of BOQ). | 2 | Cum | 4,500 ₹9,000 | 3,500 ₹7,000 | 5,000 ₹10,000 | 3,500 ₹7,000 | 3,500 ₹7,000 | 4,000 ₹8,000 | 3,500 ₹7,000 | 4,500 ₹9,000 |
| 7.00 | Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed. | 1.75 | Qtl | 500 ₹875 | 10 ₹17.50 | 200 ₹350 | 100 ₹175 | 100 ₹175 | 30 ₹52.50 | 50 ₹87.50 | 500 ₹875 |
| 8.00 | Steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed. | 175 | kg | 90 ₹15,750 | 85 ₹14,875 | 100 ₹17,500 | 90 ₹15,750 | 95 ₹16,625 | 100 ₹17,500 | 90 ₹15,750 | 90 ₹15,750 |
| 9.00 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed. | 11.7 | Cum | 50 ₹585 | 10 ₹117 | 1,000 ₹11,700 | 100 ₹1,170 | 100 ₹1,170 | 30 ₹351 | 10 ₹117 | 90 ₹1,053 |
| 10.00 | Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4, complete all as specified and as directed. | 3 | Cum | 3,500 ₹10,500 | 2,500 ₹7,500 | 7,000 ₹21,000 | 3,500 ₹10,500 | 4,200 ₹12,600 | 3,800 ₹11,400 | 4,000 ₹12,000 | 4,500 ₹13,500 |
Updated dates
Tender Value
₹48.8 L
EMD Value
₹98,000
Closing Date
23 Oct 2025, 6:00 pmClosed
GE (N) Akhnoor
GE (N) Akhnoor C/O 56 APO Pin-181201
SPECIAL REPAIR TO BLDG NO P 06 AT FD HOSP T 20 COOK HOUSE AT EME BN AND PROVN OF MES BDY PILLARS AT VARIOUS LOC UNDER GE N AKHNOOR
2025_MES_732635_1
GE(N)/AKH-49/2025-26
Open Tender
Civil Works
180 days
Akhnoor
CLASS D Cat a i
8 documents required · 8 mandatory
₹500
GE (N) Akhnoor
₹98,000
Yes
19 Dec 2025
25 Sept 2025
30 Oct 2025
25 Sept 2025
23 Oct 2025
9 Oct 2025
Amount
Demolition / taking down of existing old tarfelt , water proofing membrane, water proofing plaster of any description any type over RCC roof including any roof tiles, cement mortar screed, concrete screed of any thickness, to receive plaster and disposing off the debris out side MoD land complete all as specified and as directed.
Rendering 15mm thick cement plaster with cement mortar(1:3) with water proofing compound on fair finishes of brick work or concrete surface of roof slab, to be finished even and smooth(without using extra cement ) all as specified and directed.( Water proof compound shall be paid separately)
Supply only liquid water proofing compound conforming to IS 2645-1975 of approved make complete all as specified and directed.(Dosage- @ 200ml per 50Kgs of Bags of cement) all as specified and as directed.
Roof treatment :- (a) Apply a coat of bituminous primer conforming to IS - 3384 @ 0.40 Kg/Sqm on prepared surfaces. (b) After drying of primer apply a coat of hot blown 85/25 penetration grade blown bitumen conforming to (IS-702 @ 1.20 Kg/Sqm of surfaces. (c) Provide APP modified polymeric five layed membrane with central core of 100 micron high molecular high density film. Minimum weight of APP modified water proofing membrane shall be 3 Kg per Sqm. Product Name Multi p[lus manufactured by M/S STP texa Ltd Gurgoan/Hyper Plus Standard Manufactured by IWL India ltd Chennai, Bengal Acquaflux manufactured by Bengal bitumen New Delhi/Superior plus 310 by STP Lfd and any other product as appproved by E-in-C Br will be used. APP membranne will be laid across the slop from lowest line of slopping roof toward ridge with minimum end lap of 150mm and side lap of 75mm bonded with hot blown. (d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as perIS 1203 will not be more than 40/Confiming to IS 702 @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bvitumen coat. (e) Coved fillet in PCC (1:2:4) type BO radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall around opening and treatment mentioned above (except fine sand) shall be applied followed by a cement plaster 20mm thick in CM 1:6. (f) If Non accessible roof:-After providing (a) to (d) provide aluminium paint as per manufacturer instruction.
Sunken Floor treatment :- Providing and laying of water proofing treatment to sunken portion by applying cement slurry mixed with acralic based polymer modified cementitious composite compound of make as approved including demolition and filling of sunken floor by PCC 1:5:10 (Using aggregate). (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer allowed to air cure for 4 Hours. (b) Second layer of slurry of cement Q 0.242 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.125 Kg/ Sqm his layer allowed to air cure for 4 Hours. Note :- 1. Concrete for sunken slabs shall be mixed with WP compounds as manufacturdrs instructions before carrying out water proofing treatment the sunken slab slab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested ( Water proof compound rate is superatly. 2. 50mm thick PCC at the bottom of slab and slope shall be 1:20 toward the corner of outer wall and GI pipe of 50mm dia (Med grade) be inserted at corner projecting outside 20 cm . 3. 15 mm plaster mised with WP Compound shall be provided while concrete is green 4. Only floor area shall be measured for payment purpose.
Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with water proofing liquid as per manufacturer's instructions as in copings, roof kerb etc including weathering, slighlty rounded or chamfered angles and throating etc complete all as specified and directed. (water proofing liquid to be measured and paid separately under relevant item of BOQ).
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and as directed.
Steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and as directed.
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4, complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 in half brick thick, completeall as specified and as directed.
Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and as directed.
Rendering 5 mm thick in CM (1:3) as in ceiling finished even & smooth w/o using extra cement all as specified and as directed.
15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces of walls & finishing the surface even and smooth without using extra cement, complete all as specified and as directed.
Rendering 15 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces preparatory to distemper complete all as specified and as directed.
Preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and as directed.
Preparation on old plastered surfaces of walls and applying two coat of oil bound distemper complete all as specified and as directed.
Preparation on old plastered surfaces of ceiling and applying two coat of white wash complete all as specified and as directed.
Preparation of old or un plastered surfaces & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed. Note :- (i) The work shall be carried out in different shade and the same shall be got approved from Engineer-in-charge/GE/ (ii) The work shall be carried out upto 4th storey of bldgs and no extra payment shall be admissible for necessary form work & scaffolding required for the same all as specified and as directed.
Preparation of newly plastered surfaces & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced) in chajjas shelves, roof slab and cover slab etc not exceeding 15 cm thickness (below or above ground level) reinforcement cut as required to facilitate demolition complete all as specified and directed.
20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 15mm thick screed bed in cement and sand mortar 1:4 complete all as specified and as directed. Note:-(Size of Kota Stone slab shall be not less than 53 cm x 53 cm).
Description all as per item No 25 above but in skirting/dado incl 10mm thick rendering CM 1:4 complete all as specified and directed.
Non-skid ceramic coloured tiles 400x400x 7 to 8 mm thick (square/ rectangular) in floors etc all of each tiles exceeding 0.11 Sqm but not exc 0.18Sqm. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
Glazed ceramic coloured tiles 450x300mmx7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick plaster in cement mortar 1:4, complete all as specified and directed.
Granite flooring (of any type) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, moulding & polishing laid over & including 15mm thick screed bed in CM 1:4, complete all as specified and as directed.
Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified and as directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base floor finishing surface even and fair, complete all as specified and as directed.
Repair to balcony/facia and soffit of chajjas etc by taking down old plastered surfaces and rendering 15 mm thick where required to match with the existing thickness in CM 1:4 and hacking clearly the edges and corners smooth and rounded for new plastered area exceeding 30sqm in width or girth including formwork/scaffolding work upto height 7.0mtr above ground level of bldg and preparation of plastered surfaces by applying two coats exterior emulsion weather proof paint (Apex)over a coat of primer complete all as specified and as directed.
Reinforced cement concrete type B0 1:2:4 using (12.5mm graded crushed stone aggregatge) for Chajjas/Balcony/Landing work all as specified and as directed.
Formwork to sides and soffits/faccia of floor or roof beams, beam haunchings, girders, bressummers, lintels, chajja, cantilevers, shelves including supports, overhangs, etc. complete all as specified and directed.
TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and as directed.
Reinforced cement concrete (Nominal mix), type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including use and waste of necessary form work complete all as specified and as directed.
Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size not exc 1.5 Sqm each complete all as specified and as directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and not exc 4.00 Sqm each complete all as specified and as directed.
Taking down shutter of any description not exc 1.0 sqm each complete all as specified and directed.
Mild steel framed work as in door or gate of angle or other section with gusset plate, rail braces complete drilled for fixing of steel sheeting or other covering . door etc to be prepared for hanging of sliding with grills, grating etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, conforming to Fe-410-W(Gde-E-250) quality-A, including one shop coat of primer complete all as specified and directed .
Pressed steel frames for doors with one or more rebates of size 105x60mm including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed.
Pressed steel frames for doors with one or more rebates of size 125x60mm including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia thresh hold bar complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in parapet coping all as specified and directed.
Plain cement concrete 1:3:6 type C-1 (using 12.5mm graded stone aggregate) as in back filling of pressed steel frame and all as specified and as directed.
Solid PVC (Door/almirah/cupboard) frames of size 50 x 47mm made out of 5mm dia plain colour PVC Sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing all as specified and as directed.
Factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed.
35mm thick flush shutters, solid core with particle board exterior grade as per IS 2202 of 199 (Part-I) flush door shall be internally lipped as per clause .8.55.2 of SSR Part-I 2009 complete all as specified and as directed.
35mm thick 2nd class soft wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc devided into square with sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
12mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as in kitchen cupboard and bottom shelf of cooking platform complete all as specified and directed.
Prelaminated particle board 18/19mm thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed in repairs with screws to timber frame work, complete all as specified and directed.
External teak wood lipping 6 mm thick fixed with nails for 18/19 mm thick board, complete all as specified and as directed.
Sheet glass ordinary quality, 3mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane, complete all as specified and as directed.
Figured glass pin headed type, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50Sqm in each pane, complete all as specified and as directed.
Galvanized mild steel wire-cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
100mm butt hinges medium weight cold rolled mild steel, complete all as specified and as directed.
75 mm butt hinges, medium weight cold rolled mild steel, complete all as specified and as directed.
Aluminium anodised barrel tower bolt 150 mm, extruded section ISI marked complete all as specified and as directed.
Aluminium alloy handles, cast type, anodised of size 100mm and fixed, complete all as specified and directed.
300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and as directed.
300mm Mild steel ordinary rat tail helical door springs including roller and roller plate fixed, completeall as specified and as directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length of cover plate 100mm , all as specified and directed.
Curtain rail ,20 mm dia Stainless steel ,chromium plated fixed with CP bracket, incl taking down of old curtain rods, complete all as specified.
Steel windows box type factory made with shutter with or without dovetailed bar ( glass & gauged shutter) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts in each shutter 100mm long with & including 8mm square bar grills, complete all as specified & as shown on drg No. CEUZ/TD/1517/15 Sh No 1/3 to 3/3. Note:-(a) Fixed type glass panes shutter if any provided in above same window shall be measured and paid separately & area of these fixed shutter shall be deducted from total area of box type window for payment purpose. (b) Sheet glass/ wire cloth shall be measured & paid separately under respective item
Factory made box type steel ventilators top hung shutter shutters glass/glazed including guard bars ,hinges,steel handle,tower bolt and steel peg stay,complete with or without glazing bars ,devotiled or welded,including one coat of red oxide primer complete shown as drawing No (CEUZ/TD/1517/15 Sh No 1/3 to 3/3)
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of Ist quality over a coat of pink primer, complete, all as specified and as directed.
Preparation of old steel surfaces of any description exc 10 cm width or girth, and applying one coat of synthetic enamel paint complete all as specified and directed.
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'S' trap fixed in repairs complete of make all as specified and directed. specified in list of make as approved by GE.
PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections fixed in repairs, complete all as specified and as directed.
Vitreous china WHB (White) of size 550X400mm including waste fittings chromium plated brass ,CP steel chain and rubber plug,procelain stopper ,and pair of CI brackets, waste pipe fixed as in repair complete all as specified and as directed.
CP Sink mixer central hole basin mixer with popup waste system with 450mm long braided hoses (15mm cartridge size) fixed in repairs all as specified and approved.
PVC connection 15mm size with PTMT nuts of length 600mm size complete all as spd and directed.
Angle valve/concealed stop cock (weight not less than 0.40Kg as mentioned in SSR part- 1 clause No. 18.14.2) of cast copper alloy (ISI Marked) chromium plated fancy type scrwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore fixed in repairs complete all as specified and directed.
Bib tap 15 mm bore with flange, Brass CP, fancy type(long body). with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repairs, complete all as specified and as directed.
CP Brass wall mixture with Telephonic shower arrangement for mixing hot and cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type as in repairs complete all as specified and directed.
Corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf with chromium plated bracket guard complete all as specified and directed.
Chromium plated brass towel rail 20 mm dia D-type 60 cm long including bracket fancy type heavyweight complete all as specified and as directed.
Brass chromium plated shower rose 125mm size with or without swivel joints, with arm any size, including fixing to steel pipe or union complete all as specified and directed
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal from site, complete all as specified and directed.
Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal from site, complete all as specified and directed.
Supply and fixing 20 mm nominal dia CPVC pipes SDR 11, having thermal stability for hot & cold water supply, including plain CPVC SDR11 fittings & brass threaded fittings on walls/ceiling or laying in floors, including fixing with the pipe with clamps. Including jointing of pipes & fittings with one step CPVC solvent cement all as specified and directed.
Supply and fixing brass elbow 3/4x12 for 20mm outer dia of CPVC pipes, complete all as specified and as directed.
CPVC Brass Elbow 20mm dia all as specified and directed.
GI tubing 15mm dia 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for GI tubing including cutting chassis wherever required with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc all as specified and directed.
GI tubing 20mm dia 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including cutting chassis wherever required for GI tubing with all necessary GI fittings like bends, elbow, unions, tees, sockets, short pieces, plugs, hooks/clamps etc all as specified and directed.
Dismantling water tanks and removing to store of cap exc 500 but n.exc 1000 ltr all as specified.
Rotational moulded polyethylene water storage tanks of 1000 litres capacity,three layered and white in colour(cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and directed.
20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) fixed in repairs, complete all as specified
20mm bore gun metal glove or gate valve with iron wheel head screwed both end for iron pipe and fixed in repairs, complete all as specified and as directed.
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern), includding all fittings, heads , shoes bends , swan-necks etc . complete all as specified and as directed.
110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints fixed to wall with PVC/MS holder clamp etc complete all as specified and as directed.
110mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc., complete all as specified and directed.
75mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints fixed to wall with PVC/MS holder clamp etc complete all as specified and as directed.
75mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc., complete all as specified and directed.
PVC (SWR) branch bends any radius 110mm bore incl access door complete all as specified.
PVC (SWR)110 mm junction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door all as specified and as directed.
PVC (SWR) branch bends any radius 75mm bore, complete all as specified.
PVC (SWR) 75 mm junction single, (Single T) equal or unequal ordinary or inverted with spigot or socket branch with oval access door all as specified and as directed.
PVC junction, single (single Y), equal or unequal, ordinary or inverted with spigot or socket branch of 75mm bore with access door, complete all as specified and directed.
PVC SWR vent cowl 75 mm complete all as specified and as directed.
PVC (SWR) 75 mm dia floor trap plain with grating including jointing with solvent cement fixed in repairs, all as specified and directed
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 100 mm bore of pipe all as specified and as directed.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 75 mm bore of pipe all as specified and as directed.
Hard core of broken stone/boulders of gauge n exc 63mm deposited spreed and leveled in layers n exc 15cm thick watered and rammed to a true surface, complete as specified and as directed.
100mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor/hardstanding etc, finishing surface even and rought to receive topping layer, complete as specified and as directed.
Sand cushioning in flooring below interlocking tiles laid in layers 25mm thick complete all as specified and directed.
Machine pressed concrete interlocking paver block any shape, size and colour confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment over sand cushion complete all as specified and directed. Note:- Sand cushioning shall be measured & paid seperately.
Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof kerb, padding , finished surface even and fair, complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150 mm diameter incl fittings, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying under ground cable, erection of poles etc. n exc 10 sq m on and getting out etc in any type of soil, complete all as specified and directed.
Brick work with sub class 'B' bricks , straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
Plain cement concrete 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
Concrete bed to drain pipes in PCC 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed.
RCC class NP3 150mm dia drain pipes laid in trenches and jointed with & including collar ISI marked complete all as specified and directed.
Pre cast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs including use and waste of necessary formwork complete all as specified and directed.
TMT Bar 8mm dia bar and over cut to length, bent to shape required including cranking, bending, hooking ends, binding, with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cementt concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, internal dia of pipe in 150mm, complete all as specified and directed.
Dismantling timber scantlings (Framed work) 40 Sqcm and over in section, in any position complete all as specified.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed.
Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets GI framework complete all as specified and directed.
Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified and directed
Pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter, ridge & similar works fixed with self tapping screws complete all as specified.
4mm thick prelaminated designer ceiling board including GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size 25x25x3mm fixed along wall perimeter, main runner 'T' of size 25x40x3mm , secondary runner 'T' of size 25x30x3mm suspended with 3mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels, complete all as specified.
Dismantling of stone slab and tiles of any description or thickness in floor apron etc laid or bedded in any mortar complete all as specified and directed.
Non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) in floors etc area of each tiles exceeding 0.11 Sqm but not exc 0.18 Sqm. Set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and as directed.
15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces including mixing of WPC as per manufacturer's instruction & finishing the surface even and smooth without using extra cement, complete all as specified. (Note:- WPC shall be measured and paid separately)
Rendering 10mm thick in cement mortar 1:6 on fair faces of bricks work or stone surfaces and finished the surface even and smooth without using extra cement, complete all as specified and as directed.
Preparation of new decorated surfaces of walls applying two coats of cement base paint over a coat of alkali resistance primer all as specified and directed.
Preparation of existing treatment of old surface of wall and applying two coats of white wash complete all as specified and directed
Removal of existing treatment and applying two coat of cement base paint to walls complete as specified and directed
Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc as approved complete all as specified and directed.
Powder coated aluminium anodised door shutters(minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
Door closer of aluminium (Die cast body), hydraulically regulated, designation No 3, universal type, suitable for door shutters of size 851mm to 1000mm of width and of weight between 61 to 80 kg, ISI marked fixed in repairs, complete all as specified and as directed.
Sheet glass ordinary quality, 4mm thick, glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane, complete all as specified and as directed.
Powder coating Anodised aluminium window and ventilator shutters, side hung type without sash bars aluminium sections weighing 0.55 kg/m (glass & wire mess shall be measured and paid separetely) including necessary joining cleats, glazing rubber packing, anodised aluminium clips, snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 Nos.) suitable handle (1 N.) and 100 mm long aluminium tower bolt (02Nos) per shutters complete as specified and as directed.
Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed.
35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, complete as specified and as directed.
Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified.
Kitchen utensil rack in steel made of premium grade stainless steel and highly durable and rust proof of size not less than 90cmx80cmx20cm fixed in repairs complete all as specified and directed.
Stainless Steel sinks with drainage board made of stainless steel (1mm thick) kitchen or laboratory with plugs,washers and wastes pipes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets fixed as in repairs and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed. Make as in list of of the makes to P.S. as approved by GE.
PVC SWR bends any radius 110 mm bore, complete all as specified and as directed.
Chromium plated brass towel rail 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls complete all as specified and as directed.
Pre cast Reinforced cement concrete 1:2:4, B-1 (Using 20mm graded crushed stone aggregate) as in manhole covers slab/shelves etc in cement mortar 1:6 including necessary form work for fair finished surfaces complete all as specified and directed.
TMT Bar 8mm dia bar and over cut to length, bent to shape required including cranking, bending, hooking ends, binding, with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips, complete all as specified and directed.
Chequered cement concrete tiles 300x300x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment to match shed of tiles, laid over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified.
Plain cement concrete 1:2:4 type B0 using (12.5mm graded crushed stone aggregate) as in pcc coping, kerb stone, kneelers, apex stones, bed plates etc including weathering, slightly rounded complete all as specified and directed
Plain cement concrete 1:3:6 type C-2 (40mm graded aggregate) as in foundations, filling and mass concrete for filling post holes, complete all as specified.
Formwork to sides of pillars, post, struts coloumn etc square rectangular, polygonal section for rough finished surfaces all as complete all as specified.
Reinforced cement concrete Design Mix (M-25) using (20mm graded crushed stone aggregate) as in beams cantilevers, bressumers etc complete all as specified and as directed.
TMT bars 5mm dia and over upto and including 10mm dia in stirrups, specers, and binders etc, cut to length, bent to shape required, including cranking, bending spirally for hooping coloumns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
Preparing surfaces of plastering or unplastered surfaces on walls applying two coats of cement base paint over a coat of alkali resistance primer all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed.
One light point controlled by one switch
One 3 pin 5 amps socket point controlled by one 5 amps switch on independent board .
One 3 pin 5 amps socket point controlled by one 5 amps switch on same board .
All as per item No-160 here-in-before but point wiring with 2.5sqmm and earth conductor of size 2.5sqmm complete all as specified and directed for the following:-
One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.
Supply only Modular type switch 10 Amps, single pole,1way,1/2 module,240V, ISI Marked complete all as specified and directed.
Supply only Modular type switch 16 Amps, single pole, 1way, 1/2 module, 240V, ISI Marked Complete all as specified and directed.
Supply only Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed.
Supply only Modular type socket 16 Amps, 2/3 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed .
Supply only angle lamp holder, insulated body with back plate for bulb complete all as specified and directed.
Supply only Ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
LED light fitting General purpose surface and wall mounted LED batten with Aluminium housing integrated electronic driver, 20W, 4 feet and connecting up with twin core twisted copper wire from LED fitting to ceiling rose and removing old unserviceable fitting complete all as and approved.
LED light fitting General purpose surface and wall mounted LED batten with Aluminium housing integrated electronic driver, 10W 2 feet and connecting up with twin core twisted copper wire from LED fitting to ceiling rose and removing old unserviceable fitting complete all as specified and approved.
20 Watt LED inverter batten capacity and polycarbonate channel, lithium ion battery with charging time 8 to 10 hours and backup time upto 4 hours with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and approved.
LED bulb 12 watts, 240Volts,50Hz pin type and including removing old unserviceable item complete all as specified and approved.
LED secruity light fitting of capacity 25 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with suitable inbuilt surge protector and cable connection from ceiling rose to light fitting and testing and including removing of old unserviceable item complete all as specified and approved.
Supply & fixing and in repair sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 8 way for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat all as specified and as directed.
Supply & fixing and in repair MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed.
MCB single pole & neutral 40 to 63 amps 240 volts 10 KA 'C' series fixed in repair, complete all as specified.
Taking down old /unsv earthing and Earthing complete with galvanized steel earth plate electrode 600mm x600mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 65mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape Gl medium grade 40mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm Fl with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion.
Exhaust fan single phase metal body, AC 230 Volt, 50 Hz, 900 RPM of size 300mm sweep IP-55 with louvers shutter complete with all accessories including connecting up from ceiling rose complete all as specified and directed. (Old unserviceable exhaust fan shall be deposited to MES store yard).
Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour code and applying putty including cutting and chiselling and complete all as specified and directed. Note :- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as RM.
Ceiling fans complete with blades, down rods, and accessories, 230 volt, 1400mm sweep, min air delivery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) including taking down old unsv fan, complete all as specified and directed. (Old unserviceable exhaust fan shall be deposited to MES store yard).
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Galvanized iron medium class pipe of 25mm bore including fittings and jointing inserting necessary fittings of suitable size for connecting to existing pipeline complete all as specified and directed.
25mm bore gun metal glove or gate valve with iron wheel head screwed both end for iron pipe and fixed in repairs, complete all as specified and as directed.
Single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB of capacity 20 amp 240 volts and connecting electrically including taking down unserviceable MCB complete all as specified and directed.
Supply and fixing in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece incl making holes on walls for proper fixing with nuts and bolts complete making the surface good as per existing all as specified and directed.
Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 25 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
DWC HDPE tubing 50mm dia for open and underground cable cut to size and making the tubing for cable protection incl cutting of road surface & making good after laying of tubing, complete all as specified and directed. Make:--Supreme, Prince, SFMC as approved.
M/S KARAN SINGH CONTRACTOR (BID ID -3457837)
M/s Rajesh Kumar Contractor (BID ID -3452306)
Ankush Gupta (BID ID -3457154)
M/S JEEVAN LAL SHARMA (BID ID -3457348)
bushan kumar (BID ID -3457553)
M/s Chopra Constructions (BID ID -3456693)
ASIA ENTERPRISES (BID ID -3452801)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender49.pdf
Tender Documents • 1.04 MB
BOQ_820298.xls
BOQ • 3.81 MB
Download all tender documents and submit your bid