Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NIL NEAR BPCL PETROL PUMP MAKARPURA MANEJA VADODARA GUJARAT 390014 | VADODARA | GUJARAT | 390014 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Techno-commercially Not Acceptable. |
| 4 | Rejected-Technical | Rejected-Technical Techno-commercially Not Acceptable. |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
4 Apr 2022, 3:00 pmClosed
SUSHANT DESHPANDE
thyssenkrupp Industrial Solutions India Pvt Ltd Vikhroli Mumbai India
Supply of POWER TRANSFORMER as per Technical Specifications for Numaligarh Refinery Limited
2022_NRL_666603_2
TK-1P22A-MP-RFQ-0017
Open Tender
Electrical Goods/Equipment
365 days
Numaligarh Refinery Limited Assam
As Per Tender Documents
8 documents required · 8 mandatory
₹0
₹15 L
Yes
18 Aug 2022
10 Feb 2022
5 Apr 2022
10 Feb 2022
4 Apr 2022
18 Feb 2022
10 Feb 2022 - 16 Feb 2022
SUPPLY OF POWER TRANSFORMERS FOR NREP PROJECT
Design, detail engineering, procurement, manufacturing, inspection, factory acceptance testing (FAT), packing, forwarding, supply, site acceptance testing (SAT) and commissioning of Power Transformers including Testing & Inspecition as per ITP (Part-IV), transportation, route survey (if required) and supply till site including Special Tools & Tackles, Commissioning spares & Consumables & Mandatory spares (Charges to be quoted sepately at BOQ Column No. 26) along with items items indicated below for POWER TRANSFORMERS Tag No. - 1U64-SS-14-TR-210A/B (2 Nos.) to be installed at Numaligarh Refinery Limited(NRL), Assam as specified in Material Requisition. A) rating - 25/31.5 MVA, 33/ 6.9 kV, ONAN/ONAF, Dyn11, Z=10% (with no negative tol.) at 25 MVA, OCTC range ±5% in steps of 2.5% B) Online Partial Discharge (PD) monitoring system C) Online Condition Monitoring System D) Online moisture removal System
Design, detail engineering, procurement, manufacturing, inspection, factory acceptance testing (FAT), packing, forwarding, supply, site acceptance testing (SAT) and commissioning of Power Transformers including Testing & Inspecition as per ITP (Part-IV), transportation, route survey (if required) and supply till site including Special Tools & Tackles, Commissioning spares & Consumables & Mandatory spares (Charges to be quoted sepately at BOQ Column No. 26) along with items items indicated below for POWER TRANSFORMERS Tag No. - 1U64-SS-14-TR-210A/B (2 Nos.) to be installed at Numaligarh Refinery Limited(NRL), Assam as specified in Material Requisition. A) Rating - 31.5/40 MVA, 33/ 6.9 kV, ONAN/ONAF, Dyn11, Z=10% (with no negative tol.) at 31.5 MVA, OCTC range ±5% in steps of 2.5% B) Online Partial Discharge (PD) monitoring system C) Online Condition Monitoring System D) Online moisture removal System
Charges for SITE Supervision of Erection / Installation and Testing for SUPPLY OF POWER TRANSFORMERS FOR NREP PROJECT
Per diem charges for upto 8 hours work on normal working days.
Overtime rate / hour beyond normal 8 hours work on normal working days.
Overtime rate / hour for work on weekly off days / holidays (as applicable to Refinery site).
Description of Work / Item(s)
Amount
BREAK-UP OF TOTAL MANDATORY SPARES PRICES For POWER TRANSFORMERS Tag No. - 1U64-SS-14-TR-210A/B (2 Nos.) Rating - 25/31.5 MVA, 33/ 6.9 kV, ONAN/ONAF, Dyn11, Z=10% (with no negative tol.) at 25 MVA, OCTC range ±5% in steps of 2.5%
BREAK-UP OF TOTAL MANDATORY SPARES PRICES For POWER TRANSFORMERS Tag No. - 1U64-SS-14-TR-210A/B (2 Nos.) Rating - 31.5/40 MVA, 33/ 6.9 kV, ONAN/ONAF, Dyn11, Z=10% (with no negative tol.) at 31.5 MVA, OCTC range ±5% in steps of 2.5%
Description of Work / Item(s)
Amount
BREAK-UP OF TOTAL 2 YEARS OPERATIONAL SPARES PRICES For POWER TRANSFORMERS Tag No. - 1U64-SS-14-TR-210A/B (2 Nos.) Rating - 25/31.5 MVA, 33/ 6.9 kV, ONAN/ONAF, Dyn11, Z=10% (with no negative tol.) at 25 MVA, OCTC range ±5% in steps of 2.5%
BREAK-UP OF TOTAL 2 YEARS OPERATIONAL SPARES PRICES For POWER TRANSFORMERS Tag No. - 1U64-SS-14-TR-210A/B (2 Nos.) Rating - 31.5/40 MVA, 33/ 6.9 kV, ONAN/ONAF, Dyn11, Z=10% (with no negative tol.) at 31.5 MVA, OCTC range ±5% in steps of 2.5%
VOLTAMP TRANSFORMERS LIMITED
VOLTAMP TRANSFORMERS LIMITED
VOLTAMP TRANSFORMERS LIMITED
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid