| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.6 LAccepted-AOC | 1 | Accepted-AOC lowest amount | |
| 2 | 2₹6.7 L+₹7,575.25 (1.14%)Rejected-AOC | 2 | Rejected-AOC highest amount |
Tender Value
₹8 L
EMD Value
₹8,000
Closing Date
22 Jan 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE OFFICER
PALAYAM TOWN PANCHAYAT
MP FUND 2023-2024 CONSTRUCTION OF NEW BUS SHELTER AT 11TH WARD DINDIGUL KARUR ROAD (MANAPARAI JUNCTION) IN PALAYAM TOWN PANCHAYAT
2024_DTP_407654_1
410/2023/A1
Open Tender
Civil Works
Works
90 days
PALAYAM
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹8,000
24 Jul 2024
9 Jan 2024
23 Jan 2024
9 Jan 2024
22 Jan 2024
9 Jan 2024
Amount
BUSSHELTER
Providing Levelling of existing ground as per the direction of Engineer-in-Charge. Light Jungle
Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc.,as per SS 20 A. TNDSS NO: 23 & 24 VI (S2) VI,VII 9,10 with standard specifications.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.complete as per the direction of Engineer-in- Charge.
Supplying and filling in plinth with Msand under floors, including watering, ramming consolidating and dressing complete as per the direction of Engineer-in-Charge.
Plain Cement Concrete 1:4:8 Mix (one Part of cement, four Part of M- Sand and Eight Part of aggrigate) using 40 mm size ISS HBG metal from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing. Laying and curing etc., complete as per TNDSS NO : 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge.
Reinforced Cement Concrete 1:1½:3 Mix (One Part of cement, one and half Part of M- Sand and three Part of aggregate)using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing but excluding cost of reinforcement etc. Complete with std. Specifications.(Using Vibrator) TNDSS NO: 30 V, VI (S3), VII-3.
Providing Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete) complete as per the direction of Engineer-in-Charge.
Supplying and fabrication of steel and placing in position of TMT steel rods for RCC works as per design given including cost of steel and GI binding wire in all floors etc., complete complying with standard specification in TNDSS NO:97 V,VI (S6) VII (S6), VII-3.
Brick Work in Cement Mortor 1:5 Mix (one cement, five M- Sand) using new best II Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specification
Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 ( 1 cement : 4 coarse sand) and top layer 20 mm thick mixed with 10% finely grounded hydrated lime by volume of cement . Ordinary cement finish using ordinary cement
Providing and laying of 20mm thick Polished Granite stone flooring in required design and patterns all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Smoke Gry or Silver Grey, Cat Eye or equivalent.
Spl Work: Providing supplying and fixing of 12.5mm thick MS Plate for Bus shelter's columns support. Size: 300mm x 300mm x 12.5mm thick. Each coloumns should have 2nos of MS plate with necessary holes for fixing of 1" dia Bolts.as directed by the Engineer-in- Charge. 98kgs/ sqm for 12.5mm plate
Spl Work: Providing supplying and fixing of L bend 1" dia GI threaded rod from foundation to column base plate. complete as per the direction of Engineer-in-Charge. Weight of 24mm GI Rod is 3Kg / Mtre
Spl Work: Providing supplying and installation of SS Bus Shelter with 304Grade Matt finish SS Pipe arrangements for SS Bus shelter. 168mm dia ss pipe to be used 2nos of columns & 1no of horizontal member, 114mm dia ss pipe 1no as horizontal, 60mm dia ss pipe for chair/bench outer members, 40x40 square tube to be used chairs inners, advertisement board outer frame and purlin members, 4mm thick ss sheet to be used for side end caps, roof rafters, purlin support, 8mm thick ss sheet to be used flange and cleats wherever required details as per the dwg, complete as per the direction of Engineer- in-Charge.
Spl Work: Providing supplying and fixing of 6mm thick polycorbonate roof top. Made of 6mm thick Polycorbonate sheet to be fixed on Purlin frame with necessry non leakage srews arrngements complete as per the direction of Engineer-In-Charge.
Spl Work: Providing supplying and fixing of SS Signage at Roof top. Made of 1mm thick SS sheet with necessary etching work of images complete as per the direction of Engineer-In- Charge.
Spl Work: Providing supplying and fixing of Signage for advertisement at SS Bus shelter above chair / bench area. Made of 3mm thick 2 layers of acrelic / polycorbonate sheet with graphic printed vinyl sheet to be fixed between the acrelic sheet and fixing to frame available at bus shelter with ss studs complete as per the direction of Engineer-In-Charge.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 6 sq. mm + 1 X 4 sq. mm earth wire
Wiring for light point/ fan point with 2 runs x 1.5 sq.mm FRLS PVC insulated copper conductor wiring with pvc conduit and earthing the point with 1.5 sq.mm. The rate is inclusive of cost of Wire, conduit, clamps, screws, labour and transport charges
Supplying and fixing of piano type switch / socket on the pvc switch box/ cover including connections etc. as required.5/6 amps switch and socket.
Supply of 4' LED tube light fitting. The supply of accessories like clamps, supporting brackets and hardwares with all accessories required as per site conditions. Rate is inclusive of Light fitting and installation charges
MVR INFRASTRUCTURE (BID ID -941665)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .