Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹14.5 L+₹1.1 L (8.22%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹16.8 L+₹3.4 L (25.3%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹17.7 L+₹4.3 L (32.1%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1,850
EMD Value
₹37,000
Closing Date
11 Jan 2020, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
REPAIRS/REPLACEMENT OF SUMMER APPLIANCES ,DOMESTIC AC, REFRIGERATOR, WATER COOLER ETC AND CONNECTED WORKS AT TELEPARA ,BINNAGURI AND COOCH BEHAR UNDER GE (S) BINNAGURI
2019_MES_290965_2
8323/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (S) Binnaguri
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹37,000
Yes
7 Feb 2020
16 Nov 2019
13 Jan 2020
16 Nov 2019
11 Jan 2020
24 Nov 2019
Amount
Dismantling of defective refrigerator of any make and capacity including transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/replacement of defective accessories/components and testing complete all as directed by Engr-in-charge . NOTE :- New accessories / components required shall be measured and paid separately, labour charges for fixing shall be included in the unit rate of item No. 1 here-in-above. Repair of body overhauling / repair sealeds unit (compressor ) gas charging painting etc shall be measured and paid separately. Old serviceable accessories / components obtained from item No.1 here-in-above shall be refixed as directed by the Engr-in-charge,and labour charge for refixing to be deemed to be included in unit rate of item No.1 here-in-above. sung/LG).
Supply only the following suitable accessories components of refrigerator (Make - Kelvinator/Allwyn /Godrej/Whirlpool/Usha/Samsung/LG)
Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 165/180 ltrs.
All as per item No. 2.01 here-in-above for refrigerator of capacity 250/286/310 ltrs.
Thermostat defrost type switch suitable for refrigerator of capacity 165/220/310 ltrs.
PTC Relay with overload suitable for refrigerator of capacity 165/190/200 ltrs.
PTC relay with overload suitable for refrigerator of capacity 250/286/310 Ltr
Cooling coil of suitable for size of refrigeration capacity of 250/280/310 ltrs .
Megnetic door gasket including fixing accessories for refrigerator of 165/180 Ltrs capacity.
Megnetic door gasket including fixing accessories for refrigerator of 250/286/310 Ltrs capacity.
Capillary tube of size 0.36 for any type/size refrigerator
Thermostate suitable for 250/286/310 ltr
Door switch for refrigerator of any capacity.
Lamp holder, screwed/pin type including 15 watt, lamp 240 volts.
LED lamp suitable for refrigerator of capacity 165/250/310 ltrs
Copper pencil strainers of size 4" long double mouth .
Inner shelf for refrigerator of capacity 165/180 ltrs.
All as per item No. 2.15 here-in-above but for refrigerator of 286 to 310 ltrs capacity.
PVC chillar tray for refrigerator of capacity 165 ltrs.
All as per item No.2.17 here-in-above but 286 to 310 ltrs.
Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types.
Vegetable tray for 165 ltrs refrigerator.
Vegetable tray for 286 to 310 ltrs refrigerator.
Freezer door for 165 ltrs refrigerator.
Freezer door for 286 to 310 ltrs refrigerator.
Bimetal 2 wire / 3 wire / 4 wire
Running capacitor 6 / 10 mfd
Forst free fan motor SP 230 volts
Sensor for cooling coil
PCB timmer of make Samsung/LG
Condenser coil for 165 to 200 Ltrs
Condenser coil for 250 to 310 Ltrs
M&L for repair to PCB of refrigerator of any capacity and make all as specified and directed
Supply and charging of Gas R-134 A or equivalent including necessary arrangement for charging gas & pressure testing complete all as specified and directed.
S&F of heating coil including fixing accessories suitable for 250/286/310 ltrs
S&F of T-Fuse for refrigerator of cap 250/286/310
Taking out burnt compressor after disconnecting suction and discharge line and supply and fixing new compressor as per existing including testing complete all as specified and directed for Regrigerator of Capaicty 165/180 Ltrs (Re- Charging of gas will be measured and paid separetely)
All as per item No.07 here-in-above but for compressor of capacity of refrigerator 250/286/310 ltrs .
Re-charging of refrigerator gas (R-134) for refrigerator of capacity 165 to 185 ltrs after vaccuming dehydration leak testing of the system as per system standard practice for proper cooling effect and satisfactory performance complete all as specified and as directed.(Re Charging of gas will be measured and paid separetely)
All as per item No. 09 here-in- above but for refrigerator of capacity 286 to 310 ltrs.
Supply and charging Gas R-600 including necessary arrangement for charging gas & pressure testing complete all as specified and directed by Engr-in-Charge.
WATER COOLER
Dismantling of defective water cooler storage type of 40 ltrs capacity including transportation to workshop and back for thorough checking/including all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed. NOTE : (a) New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate. (b) Repair of body overhauling/repair, sealed compressor unit gas charging, painting etc shall be measured and paid separately.
All as per item No. 13 here-in-above for water cooler storage type 80 ltrs capacity.
All as per item No. 13 here-in-above but for water cooler storage type 120 ltrs capacity.
Supply only the following suitable accessories of water cooler. (Make -Shreeram/ BLUE STAR /Usha/Voltas)
Condensor coil for water cooler 40 ltrs capacity of similar specification as of old one.
All as per item No. 16.01 here-in-above but water cooler of 80 ltrs capacity
All as per item No. 16.01 here-in-above but water cooler of capacity 120 ltrs.
Aluminium fan blade for blower motor for water cooler of capacity 40/80/120 ltrs.
Wiring set complete consisting of PVC insulated cable wiring stranded copper conductor connecting clips etc suitable for water cooler 40/80/120 ltrs.
Thermostat including plastic regulating knob as per existing for water cooler of cooling capacity 40/80/120 ltrs.
Relay for water cooler type suitable for water cooler storage cooling capacity 40/80 ltrs/hrs.
Relay for water cooler type suitable for water cooler storage cooling capacity 60/120 ltrs/hrs.
Over load protector type 1022 suitable for water cooler.
All as per item No. 16.09 here-in-above but type 522 AC suitable for water cooler of capacity 40/80/120 ltrs/hrs.
Self closing bib tap/push tap 15mm dia chromium plated steel suitable for water cooler 40/80/150/120 ltr/hrs capacity.
PVC connection pipe high density 15mm dia 300mm long including jublee clamps for inner connection from tank outlet to tap.
15 mm dia PVC connection pipe 450 mm long complete with PVC union at both end. (Make - Prayag/ Prince/ kisan)
15 mm bore Stop cock brass both end screwed.
15 mm dia Float valve PVC complete with all accessories . (Make - Prayag )
Running Capacitor 10/15 mfd 230 volts AC, 50 Hz suitable for water cooler (Make - Sarada or equivalent)
Starting Capacitor 40/60 mfd, 230 volts.(Make - Sarada or equivalent)
Capillary tube copper size 0.36
Copper pipe 3/8"
Copper pipe 1/4"
Copper pipe 3/16"
Supply only new compressor suitable for 40/80 ltr/hrs storage capacity including testing all as specified and directed by Engineer-in-Charge. (Recharging of gas will be measured and paid separately).
All as per item No. 16.22 here-in-above but compressor of water cooler of storage capacity 40/40 ltrs/hrs,
All as per item No. 16.22 here-in-above but compressor of water cooler of storage capacity 60/120 ltrs/hrs,
Taking out old burnt Condenser fan motor and supply and fixing of new blower motor and testing suitable for water cooler any make or type.
DEEP FREEZER
Dismantling of defective deep freezer including transportation to workshop and back of any capacity, size and type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all as specified and directed by the Engr-in-Charge NOTE : (a) New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate. (b)Sealed compressor unit, gas charging, painting etc shall be measured and paid separately.
Supply only new deep freedge compressor for storage capacity of 400 ltrs deep freezer including testing all as specified and directed . (Recharging of gas will be measured and paid separately).
Supply only new deep freedge compressor for storage capacity of 500 ltrs deep freezer including testing all as specified and directed . (Recharging of gas will be measured and paid separately).
Supply only the following suitable accessories of deep freedge of any make and capacity :-.
Relay for deep freezer of any size/capacity
Overload for deep freezer of any size/capacity
Thermostate for deep freezer
4" condenser fan motor 240 volt
Supply and charging Gas R-134 A or equivalent including pressure testing complete all as specified and directed .
WINDOW TYPE AC
Scrapping out old surface of window type AC of capacity 1.5 TR/2 TR for spray painting and applying one coat of synthetic enamel spray painting with 1st grade quality of existing colour all as specified and as directed.
Dismantling all electrical connection from the unserviceable compressor unit and disconnecting gas line and taking out burned compressor of capacity 2 TR and supply and install new compessor 2 TR, 230 V, 50 Hz suitable for window AC as per existing specification , mounting pad , nut and bolt and reassembling all the connection including testing complete. .(Recharing of gas will be measured and paid separately) (Make - Carrier/ Kirloskar/ Emerson).
All as per item No. 24 here-in-above for compressor of capacity 1.5 TR.
Charging of refrigerant gas (R-22/R-410) for Split/window type AC of capacity 1.5 TR only after vaccuming dehydration, leak testing of the system as per standard testing pratice for proper cooling effects and satisfactory performance complete all as specified and as directed by Engr-in-charge.(Note- refrigerant gas M-22 will be measured and paid separately).
All as per item No. 26 here-in-above but for window type AC of capacity 2.0 TR.
Supply only the following suitable accessories of window type AC of any make and capacity :-.
(a) Starting capacitor 60/40 Mfd
(b) Starting capacitor 80/100 Mfd
(c) Running capacitor 50+2 Mfd
(c) Running capacitor 50+6 Mfd
(e) Thermostate switch
(f) cooling coil sensor
M&L for repair of PCB of window AC of any capacity and make all as specified and directed
Supply and fix swing motor for indoor unit all as specified and directed
Supply and charging of Gas R-22 or equivalent to Split/Window type AC machine including necessary arrangement for charging gas including pressure testing complete all as specified by Engr-in-Charge.
Taking out old burnt blower motor double shaft and supply and fixing of blower motor and testing suitable for window type AC of any make/any type
M&L for cutting through brick wall built in cement mortar forof window type AC of any size /capacity and making good with cement mortar 1:4 including three coat of white washing on new plastered surface including preparation of surface complete to match with existing all as specified and as directed.
Voltage Stabiliser
Dismantling and opening voltage stabiliser 5 KVA capacity single phase, 240 volts and replacement of old unserviceable worn out/defective parts and reassembling the same after necessary repair, fixing spares ,cleaning servicing including testing on completion all as specified and directed . NOTE : (a) New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate.
All as per item No. 35 here-in-above but 4 KVA capacity
All as per item No.35 here-in-above but 3 KVA capacity
All as per item No. 35 here-in-above but 2 KVA capacity.
All as per item No. 35 here-in-above but 1 KVA capacity.
All as per item No. 35 here-in-above but 0.5 KVA capacity.
Supply only main transformer suitable for automatic line voltage corrector 5 KVA, 230 volts, 50 Hz complete all as specified and directed.
All as per item No. 41 here-in-above but 4 KVA capacity.
All as per item No.41 here-in-above but 3 KVA.
All as per item No. 41 here-in-above but 2 KVA capacity.
All as per item No. 41 here-in-above but 1 KVA capacity.
Supply only relay (time limit) suitable for automatic line voltage corrector of capacity 0.5 to 7.5 KVA all as specified and directed.
Supply only Volt meter of range 0-300 volts AC .(Make - AE/ L&T/ Havells/ HPL).
Supply only Indicator lamp suitable for operating voltage 200 to 230 volts AC.
Supply only cable connector 3 way suitable for connection of stabilizer with brass screw of different size.
Supply only voltage regulating circuit board (PCB) of suitable size/type including all necessary electrical components for operating the main transformer for out put voltage 200 volts to 230 volts (2% tolerance) including all electrical connection complete all as specifed and directed.
Supply only voltage regulating transformer of voltage rating 220/12 volts to 6 volts bridge type or central type transformer of current carrying capacity 600 MA per second complete.
Supply only over load relay for stabilizer of any type.
Supply only main transformer suitable for automatic line voltage corrector of capacity 0.5 KVA.
Supply and fix voltage Stabilizer 5 KVA output voltage 230 - 240 volts, 50 Hz input voltage 170 to 220 volts including necessary nuts, bolts, wires etc complete all as specified and directed .( Make - Miracle / V- Guard )
Split AC
Dismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burned compressor of capacity 2 TR including transportation to workshop and back and supply & install new compessor 2 TR 230 V, 50 Hz suitable for split AC, mounting pad nut and bolt and reassembling all the connection including testing complete (Recharing of gas will be measured and paid separately).
All as per item no 55 here - in - before but 1.5 TR capacity.
Dismantling all electrical connection from the blower motor and taking out unserviceable burnt blower motor and supply and install blower motor suitable for 2/1.5 TR split AC and reassembling all the connection in its original location and testing complete.
Supply and fixing remote control assembly with control circuit or connected wire suitable for 2 TR/1.5 TR split type AC.
S&F swing motor(Synchronous motor) AC 220 Volt, 50/60 Hz for split type AC including necessary connection wire after taking out old one.
Supply and charging Gas R-22 or equivalent to Split/Window type AC machine including necessary arrangement for charging gas & pressure testing complete all as specified & directed by Engr-in-Charge.
Dismantling all electrical connection and taking out indoor/outdoor unit of split AC after disconnect suction & liquid line and repair, cleaning, servicing and overhauling of the same including Air filter, blower motor (indoor/outdoor) and adjusting of remote control and checking all electrical devices including fixing cable socket/gland etc and reassembling and fixing in position and leakage check the unit , charging refrigerant gas as required in the system complete (Spares required for repair and gas shall be paid separately) ( Note :- Contractor shall attend any type of complaint as and when required and no extra payment on this account shall be allowed.)
Supply only the following spares for split type AC machine as per existing specification including removing unserviceable old spares complete.
AC contactor relay for split AC of any make.
Starting relay for 1.5/2.00 TR split AC (Make - Arvind or Equivalent).
Capilary tube of size 0.45
Capilary tube of size 0.55
Copper pipe 1/2" for liquid line including fittings
Copper pipe 5/8" for suction line including fittings
Copper pipe 1/4" for suction line including fittings
Copper pipe 3/8" for suction line including fittings
PVC Fan blade suitable for outdoor condenser unit including necessary brass nut bolt etc.
Running capacitor 50/2 mfd series 8 pole
Running capacitor 50/6 mfd series 9 pole
Fan motor for indoor unit
Reversible valve
S&F PVC insulated three core copper flexible wire of size 2.50 sqmm 1100 volts grade including taking out old one complete all as directed.
S&F PVC flexible pipe 25 mm dia for cable protection including necessary clamps, screw etc .
S&F PVC drain pipe 25 mm dia suitable for spilt AC with necessary saddle screws complete.
S&F outdoor unit condencer coil for Split AC 1.5 TR capacity.
S&F outdoor unit condencer coil for Split AC 2.0 TR capacity.
S&F air filter for Split AC of any size and make
S&F liquid sensor for Split AC 1.5/2.0 TR capacity
S&F Air sensor for Split AC 1.5/2.0 TR capacity
S&F Compressor leg bush of any size for 1.5/2.0 TR capacity.
S&F insulation foam for copper pipe .
Taking down old u/s remote control assembly and dismantling the unit and replaced the unserviceable item such as PCB, transformer and magnetic coil suitable for out door split AC and reassembling the same including testing complete.
S&F factory made AC stand made out of angle ,flat etc. including fixing in wall with , nuts and bolts complete all as directed.
S&F outdoor unit of Split AC 2.0 TR with all accesorries (compressor,wiring,copper pipes ) incl fixing toWall or floor complete all as directed.
S&F outdoor unit of Split AC 1.5 TR with all accesorries (compressor,wiring,copper pipes ) incl fixing toWall or floor complete all as directed.
S&F indoor unit of Split AC 2.0 TR with all accesorries (cabinet,wiring,copper pipes,remote control ) incl fixing to wall or floor complete all as directed.
S&F indoor unit of Split AC 1.5 TR with all accesorries (cabinet,wiring,copper pipes,remote control ) incl fixing to wall or floor complete all as directed.
Supply and filling refrigeration Gas R-410 complete all as specified.
Cassette type AC
Dismantling all electrical connection from the unserviceable compressor unit and disconnect gas line and taking out burned compressor of capacity 4 TR and supply and install new compessor 4 TR 230 V, 50 Hz suitable for cassette type AC, mounting pad nut and bolt and reassembling all the connection in its original location and testing complete (Recharing of gas will be measured and paid separately)( Note : New accessories/ components required shall be measured and paid separately, labour charges for fixing are deemed to be included in the unit rate).
Supply only water drain motor .
Supply only blower motor for outdoor unit.
Supply only blower motor for indoor unit .
Supply only cooling coil sensor .
M & L for repair of PCB board for indoor/outdoor unit of cassette type AC.
S&F MNX 25 , 3 phase contactor for out door unit complete .
SCHEDULE OF CREDIT Rate quoted by the Tenderer for this schedule should not be less than rate assessed by the department shown on estimated rate column for the respective items.
Old unserviceable condenser coil of any capacity and type
Old unserviceable Aluminium blade/Fan blade
Old unserviceable thermostate any type
Old unserviceable relay of any type
Old bibcock/stopcock
Old unserviceablePVC connection any type.
Old unserviceable Float valve.
Old capacitor any type.
Old Capillary tube any size
Old unserviceable compressor for water cooler,/Refrigerator/ Deep Freezer of any capacity or type
Old unserviceable AC motor any type.
Old compressor AC any type
Old U/S cooling chamber.
Old U/S pvc cable tray/inner shelf.
Old U/S remote control assembly.
Old unserviceable PVC cable.
Old PCB of any type and capacity.
Old Indoor unit cabinet.
Old Outdoor unit cabinet.
Old brass
Old unserviceable Iron
Old swing motor/frost free fan motor
Old unserviceable copper
M/S East India Traders
BEEPEE AND COMPANY
Shree Ram Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .