Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LRejected-Finance | L1 | Rejected-Finance Higher rates | |
| 2 | L2₹1.8 L+₹12,105.20 (7.04%)Rejected-Finance | L2 | Rejected-Finance Higher rates |
Tender Value
₹1.2 L
EMD Value
₹2,400
Closing Date
30 Mar 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Estate Office, CCS HAU, Hisar
Establishment of Mushroom Unit at KVK, Mahindergarh
2021_HRY_162791_1
3191
Open Tender
Civil Works
Works
60 days
CCS HAU HISAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
₹2,400
Yes
2 Jun 2021
8 Mar 2021
31 Mar 2021
8 Mar 2021
30 Mar 2021
8 Mar 2021
120 days
Amount
Earth work in excavation in foundations, trenches, etc .in all kinds of soils, not exceeding 2 metres depth including dressing of bottom and sides of trenches ,stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 metres (HSR 6.6)
Cement concrete 1:8:16 with stone aggregate 40 mm nominal size in foundation and plinth.(HSR 10.28)
Cement concrete 1:2:4 with stone aggregate 20 mm nominal size for reinforced concrete work for walls exceeding 20 cm thickness (straight and curved) beams, girders, stairs, columns,(square or rectangular) battens and lintels etc., excluding steel reinforcement but including centring and shuttering, laid in position, complete in all respects.(HSR 10.86)
Extra over item Nos. 10.79 to 10.94 , if 1:1.5:3 mix is used, instead of 1:2:4 {HSR 10.95(a)}
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with 2 coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded {HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth (HSR 11.2)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR 11.7)
12 mm thick cement plaster 1:6 on walls (HSR 15.7)
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR 15.12)
Striking joints in lime or cement on brick and tile walls {HSR 15.69(a)}
20 mm thick cement plaster damp proof course 1:3 with 2 coats of bitumen at 1.65 kg per sqm laid hot and sanded:-{HSR 15.77 (a)} (a) vertical
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade (HSR 16.3)
Applying priming coat with metal primer on new steel or iron work including preparation of surface (HSR 16.9)
White washing three coats (HSR 16.48)
Wrought iron and mild steel (using angles, flats square bars. tees and channels) ladders, grills, gratting frames, window guards, iron door openable or fixed stair case or parapet or any other type of railing , gates and tree guards etc., including cost of screws and welding rods or bolts and nuts complete fixed in position (HSR 18.12)
Steel reinforcement TMT bars FE-500 EQR/FE-500 D grade or more for RCC work, where no included in the complete rate of RCC incluidng straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position, complete in all respect for all heights/depths/storeys/basements etc. Note: Reinforcement shall be measured in length including hooks, if any, separtely for different diameters as actually used in work excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 18.22)
Providing and fixing hard drawn steel wire fabric 75 mm x 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled section with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. (HSR 18.33)
Providing and fixing M.S. angle and T-iron frames for door, window and ventilator including iron hold fast, butt hinges of I.S.I. mark fixed in position with machine screws and duly welded including all other suitable locking arrangements provided and welded with the frame and making holes and fixing glazing clips in the frame, filing the welds and finished with a coat of red lead non setting primer complete in all respects (HSR 18.35)
Providing steel pipe I.S.I. mark in columns with 2 Nos. M.S. plates welded on both ends of the pipe including cutting etc. complete fixed in position. (HSR 18.41)
providing and fixing 0.60 mm thick high strength galvanized colour coated steel sheets having trapezoidal profiles of approved make (I.S.I. mark) in roofing, at all height, fixed in position with self drilling screws of approved shape and make, complete in all respects as per drawing & manufacture’s specifications and instruction of Engineer-in-Charge (NS).
Providing and fixing IRC fabric of size 25 X 25 mm, made of 2.90 mm to 3.25 mm diameter wire, in MS frame including 3 mm thick MS flat iron cover moulding of 12.5 mm width fixed with machine screws, welded, complete in all respects as per architectural drawing & design (excluding cost of MS frame that will be paid under HSR 18.35) (NS)
Rishabh Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .