Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹23.4 L+₹96,546.25 (4.30%)Rejected-Finance QTR NO 7 REHARI COLONY JAMMU TAWI J K PIN 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
22 Jan 2021, 6:00 pmClosed
GE NAGROTA
GE NAGROTA C/O 56 APO
SPECIAL REPAIR TO BLDG NO. TS-45 AND 115 (MAIN OFFICE BLDG) OF 651 EPU, PROVN OF FOL STORES AT CHIRWA ENCLAVE AND CERTAIN REV AND MINOR WORKS UNDER AREA OF AGE B/R-I UNDER GE NAGROTA.
2020_MES_406313_1
GEN-64/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
NAGROTA
Class D and above and category a (I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹54,000
Yes
2 Feb 2021
23 Dec 2020
28 Jan 2021
23 Dec 2020
22 Jan 2021
7 Jan 2021
Amount
Taking down chowkat with shutter (without taking off shutter from the frame) not exceeding 1.5 sqm each and removing from site (wood or steel), complete all as specified and as directed at site.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm n. exc. 4.00 sqm each and removing from site complete all as specified and directed.
Dismantling plain or corrugated sheets of any description or thickness and gauge as in roof covering, complete all as specified and directed.
Demolition of brick work / stone masonry built in cement mortar or cement lime mortar including all quoins ,arches , pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed.
Dismantling wrought iron or mild steel works of any description not otherwise provided complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
S & F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coveing/cladding to wall fixed with self tapping screws/L-type or J-type or cranked hook bolts in lieu of screw as per manufacturer instruction, complete all as specified and directed.
S & F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coveing/cladding to wall fixed with self tapping screws/L-type or J-type or cranked hook bolts in lieu of screw as per manufacturer instruction, complete all as specified and directed.
S&F aluminium anodised door shutter side hung tupe with style rails (top botom & lock rails) top rail meeting style , lock rail size 48 x 44 mm bottom rail size 108 x 44 mm frame (for chowkat & fixed galzing )size 38x 63 mm all are made from anodised aluminium section including necessary jointing cleats glazing clips rubber packing, anodised aluminium snap beading, screws of suitable size including 5 mm thick frosted sheet glass at top and 6 mm thick particle board at botom etc complete all as specified and directed.
S & F Anodised aluminium window grill 8mm dia ornamental type (design/pattern as approved by Engr-in-Charge), complete all as specified and directed.
S&F in repair brass mortice lock vertical type with 4 levers 100mm size with decorative brass handle complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stailess steel cover governing pivot madeof brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4, complete all as specified and directed.
M&L for mild steel rolled work as in roof trusses ( framed) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing( Beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc. , conforming to grade Fe 410-S, complete all as specified and directed.
S&F MS work as in wind ties for roof including securing bolts etc confirmingto Fe-410 or Fe-310 complete all as specified and directed.
Prepration of old steel surfaces any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint , complete all as specified and directed.
Prepration of new or previously steel surfaces any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for preparation of steel and iron surfaces not exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified.
M&L for 50 mm thick cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection , complete all as specified and as directed.
M & L for chequered cement concrete tiles 25 mm thick set, joined and pointed in neat cement slurry in floors with grey cement and no pigment over and including 20 mm thick screed bed or bedding layer in CM 1:4, and 75 mm thick PCC 1:2:4 type B2 (using 40 mm graded crushed stone aggregate), complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as a sub base to receive topping layer finished even and rough, complete all as specified and directed.
Screed bed or bedding layer 15 mm thick in CM 1:4 for laying floor finishes all as specified.
M&L for 10 mm thick rendering in cement mortar 1:4 as in backing coat for skirting/dado etc complete all as specified and directed.
Light shade vitrified ceramic tiles 10mm thick (square/rectangular) polished ara of each tile not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and painted in white or coloured cement to match tiles complete all as specified.
All as per ser item No.26 here in above but as in skiriting
M&L for 60mm thick factory made machine pressed precast concrete interlocking coloured paver block, with grey cement and pigment any shape and size confirming to IS 15658-2006 of M-35 grade laid over and including 50 mm thick sand coushion, complete all as specified and directed. NOTE:- (Sand cushioning measured and paid separetely)
M&L for sand for 50 mm thick filling under interlocking pavor block including watering and consolidation, complete all as specified and directed.
GI T Grid system in 600 x 600 mm module which includes providing and fixing wall angle along the perimeter of the room with nylon sleeves and wooden screws at 300 mm centre to center. Suspendeding the main tee of size from the soffit, soffit cleat, rawl plugs and wire rod & leveling spring clip at 1200mm center to center cross tee, interlockined into the pre-cut slots in the main tees at 600 mm centre to center in direction perpendicular to the main tee to make a grid of 600x 1200mm. Finally 1200 mm cross tees are interlocked in the pre cut slots in the 1200mm tees at 1200 mm center to center in direction parallel to the main tee. Cross Tees having length more than 600 mm are to be supported independently. 6 mm thick aquesostic tile square edge of size 595x595 mm shall be placed into the grid size of 600x600mm. (a) Main T-24x32 thickness 0.3 mm and length 3600. (b) Cross T-24x25 thickness 0.3 mm and length 1200. (c) Cross T-24x25 thickness 0.3 mm and length 1600. (d) Wall angle - 24x24 thickness 0.4 mm and length 3000.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surface in CM 1:6, finished even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surface in CM 1:4, finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats cement base paint , complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over and including 2 to 3mm thick wall putty, complete all as specified and directed.
S&F in repairs 5 mm thick PVC sheet fillet of width 35 mm for wall pannelling inclusing of fixing on wall to make PVC frame complete all as specified and directed.
S&F in repairs solid PVC wall lining consisting of 5 mm thick plain single side prelam PVC sheet complete all as specified and directed
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc and getting out in any type of soil complete all as specified and directed
PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation ,filling and mass concrete complete all as specified and directed
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete in any type of soil,complete all as specified and directed by Engineer-in-Charge
Removing surplus soil to a distance exceeding 250 m but n. exc 500 m and deposited where directed , complete all as specified and directed.
M&L for reinforcement cement concrete M- 25 using 20mm graded crushed stone aggregates as in foundations beams, plinth beams bases for columns etc basement slabs and mass concrete complete all as specified.
M&L for reinforcement cement concrete M-25 using 20mm graded crushed stone aggregates as in columns, pillar,piers, posts and struts complete all as specified.
Reinforced cement concrete M-25 ( using 20 mm graded aggregate) as in beams, cantilevers, lintel over 1.5m clear span complete , all as specified.
M&L for RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates for slabs suspended on walls, beams and columns, in floors ,roors, landing and in shelves complete all as specified and directed.
Fair finished formwork to edges of concrete floor and roofs and similar work exceeding 10 cm but not exceeding 20 cm wide complete all as specified and directed
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs landing and similar work not exc 200 mm thick fair finished surfaces of concrete complete all as specified and directed
Use and waste of formwork for sides of columns complete all as specified and directed
Use and waste of formwork for foundation beams etc for rough finished surface complete complete all as specified and directed
Use and waste of formwork to sides and soffits of floor or roof beams, beam hauchings, firder, bressummers, lintels, cantilvers, shelves incl supports, overhangs etc also splay between floor and beam etc for rough finishes complete all as specified and directed
Mild Steel TMT bars 6 to 8 mm dia , cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Mild Steel TMT bars 10 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips qfuality conforing to Gd I, IS 432(part I) or Fe-410 S or Fe- 410-o complete all as specified.
M&L for Hardcore of guage not exceeding 63mm, broken stone/boulders deposited, spread and levelled in layers not exceeding 15 cm thick watered and well rammed to a ture surface broken stone/boulder complete all as specified and directed.
M & L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring/hard standing, complete all as specified and directed.
M & L for 100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in flooring/hard standing, complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection etc finished cement concrete surface even and smooth without using extra cement, complete all as specified and directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M & L for rendering 5 mm thick surfaces of ceiling in CM 1:3 complete all as specified and directed.
Preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
S&F steel ventilators fixed type with glazing bars complete all as specified and directed
M&L 40 mm thick cement concrete 1:2:4 type B-0 as in DPC to horizontal or vertical surface including necessary form work complete all as specified and directed
S&F steel rolling shutters 1.25 mm thickness of leths with out ball bearing including top cover etc. complete all as specified and directed
Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares n exc 0.5 sqm in any size in each pane complete all as specified and directed.
M&L machine pressed precast concrete interlocking pver(with grey cement and pigment) any shgape andsize confirming to IS-15658-2006 of 80 mm thick M-40 grade complete all specified and directed
M&L for pre cast PCC 1:3:6 type C-2 kerb Stone jointed and pointed in CM 1:4 including necessary excavation and removal complete all as specified and directed
Applying two coat of synthetic enamel paint over a coat of primer on new concrete surface of any description not otherwise complete all as specified and directed.
M&L 25 mm thick cement concrete 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in sub base of floor surface finished even and fair to receive top layer complete all as specified and directed
M&L 20-25 mm thick machine cut kota stone flooring vover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for Glazed ceramic coloured tiles in vertical surface 450x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer over a coat of 3 mm thick wall care purtty over 10 cm width or girth complete all as specified and directed
Mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified .
S&F MS flat iron as in hold fast and similar small articles cut to length , bent to shape , drilled hole and fixed with screw etc conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed
Cutting holes in brick walls exc half brick but not exc one brick in CM for inserting holdfasts and making good in cement mortar 1: 3 or cement concrete 1:2:4 type B-1 as required in brick walls built in cement mortar or cement lime mortar and stone walls buil in lime mortar or walls of lime concrete and making good to the original surfaces of any description disturbed exc. 400 Sqcm but n. exc 1.10 sqm complete all as specified and directed by Engr-in-Charge.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft soil, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed.
M & L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concrete for post holes, complete all as specified and directed.
S&F MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction but welded tubes conforming to IS 1161-1979 grade St- 240 complete all as specified and directed.
M&L 50 mm thick cement concrete 1:2:4 type B-2, (using 20 mm graded crushed stone aggregate) as in sub base of floor surface finished even and fair to receive top layer complete all as specified and directed.
M&L 20-25 mm thick machine cut kota stone slab in riser of steps, skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing (mirror finish) complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep in any type of soil, complete all as specified and directed.
Screed bed or bedding layer in CM 1:4, 20 mm thick for laying for tiles complete all as specified and directed
M&L for chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick set jointed and poined in neat cement slurry in floors etc complete all as specified and directed
S&F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staple complete all as specified .
M&L for 2nd class hardwood plain fillets, square, rectangular or triangular insection, clean sawn, exc 6 and n exc 13 sqcm secured with nails or brads complete all as specified and directed
S&F for fancy type CP long body bib tp cast copper alloy with crutch or butterfly handle 15 mm bore screwed down screwed for iron pipe (ISI maked) complte all as specified and directed
S & F PVC connection 15mm size with PTMT nuts with length 450mm long, complete all as specified and directed.
S & F 15 mm bore Pillar taps , fancy type with capston head chromium plated, screwed down high pressure, with screwed shanks and fly nuts, complete all as specified and directed.
S&F 15 mm bore stop valve/cock fancy type , cromimum plated with long shank and cup (concealed type) complete all as specified and directed
S&F for 15 mm bore stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle and screwed both ends or iron pipe or for union complete all as specified and directed
S&F 32 mm bore for waste coupling brass, chromium plated for wash hand basin with long screwed shanks and fly nuts complte all as specified and directed
S&F 40 mm bore for waste coupling brass, chromium plated for wash hand basin with long screwed shanks and fly nuts complte all as specified and directed
S&F for wash basins vitreous china white (falt back or angle back type) of size 550 x 400 mm excluding taps, waste chain and pug and procelain stopper but including brackets and 32 mm dia waste fitting brass chromium plated with long screwed shank and fly nuts, 32mm x 600mm long PVC waste pipe complte flange end bedded in red lead cement and other end fixed in repair complete all as specified and directed
S&F stainless steel sink with drainage board madeout of 1 mm thick sheet for kitchen or laboratory with plug , washer, waste pipe etc including cast iron brackets, connecting union over all size 915 mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed
M&L for 15 mm bore GI pipe medium grade with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed
M&L for 20 mm bore GI pipe medium grade with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed
M&L for cutting chases, pinning in making good to facing where rerquired and pointing in cement mortar 1:3 to ends or edges of landing, steps cills chases for concealed water tubing exc. 10 cm but not exc. 20 cm girth complte all as specified and directed.
Preparation of old surfaces of wall and applying two coats cement base paint , complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified and directed.
M&L for precast cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as a coping, complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20 mm graded stone agregate as insurface channle and drain complete all as specified and directed
M&L for extra for forming fair finished drain or channel 45 cm inner girth in cment concrete using extra cement including form moulds mitred/stopped ends etc complete all as specified and directed
Taking down carefully aluminium conductor point wiring (light fan, socket and power) complete with fittings such as switches, sockets, lamps holder, utility light fitting, fan regulator etc and making good disturbed surface of walls and floors etc. and keeping in safe custody for taking credit, complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fan any sweep, removing blades, cleaning the fan completly for dust and dirt and hanging the same back to its original position including connecting the 3 core flexible copper wire to ceiing rose etc after the completion the point wiring including replacement old unservicable fan hook, rubber pad, nut bolts and washers etc, complete all as specified and directed by Engineer in charge.
M&L for point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly, complete all as specified and directed for the following:-
(a) One light point controlled by one switch 5 Amp.
(b) One ceiling fan/exhaust fan point controlled by one switch 5Amp
(c) One socket outlet 5Amp controlled by one switch on same board.
(d) One socket outlet 5 Amp controlled by one switch on independent board.
All as per item No.107 here in before but point wiring with 2.5 sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board.
S&F switch piano flush type 5 Amps single pole one way, complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and directed.
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type, complete all as specified and directed.
S&F of ceiling rose 3 terminal PVC/Polycarbonate isolated body, complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required, complete all as specified and directed.
S & F white powder coated CRCA housing with LEDs 36 W, 230 V, 50 Hz recess mounting LED 2 feet x 2 feet luminaries, swamless front frame with flat white hight transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S & F Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed.
S & F LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 10 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, complete all as specified and directed.
S&F in repair sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz single door with neutral and din rail, complete all as specified and directed.
S & F MCB SPN 40 Amps, 10 KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCB single pole 6 to 40 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply and laying or fixing including removing of existing cable 1100 volts grade cable PVC insulated aluminium conductor un-armoured of 16 Sqmm 2 core flat or circular, served with inner sheathing of pace tape and overall PVC sheathed in service connection suspended by insulated hangers not more than one Mtr apart including 4 mm dia suspension GI wire, complete all as specified and as directed by Engr-in-Charge.
S&F switch flame proof rotary type with termination box in LM6, 16A single pole 250V complete all as specified and directed
S&F fluorescent tube light fitting 1 x 36 w flame proof tupe FLP-WP made of aluminium alloy LM6, with elcetornic ballast bipin holders, connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
Sheet metal enclosure distribution board SPN 02 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete all specified and directed
S & F MCB DP 40 Amps, 10 KA, 230 volts 'C' series, complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 29878.50 during AOC Note:- Tenderers shall not quote for this Schedule
Hare krishna engineering const.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .