| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.8 LAccepted-AOC | ₹2.8 L | 1 | Accepted-AOC L1 |
| 2 | 2₹2.9 L+₹10,537 (3.80%)Rejected-AOC | ₹2.9 L+₹10,537 (3.80%) | 2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | RUMANA BUILDERS L1 | G M DEVELOPERS GROUP L2 |
|---|---|---|---|---|---|
| 1.00 | Stripping and stacking slate or tiles of a roof. | 24.86 | sqm | 47 ₹1,168.42 Lowest | 50 ₹1,243 |
| 2.00 | Add for planks and battens in case of items nos 8.10 and 8.11 | 24.86 | sqm | 26 ₹646.36 Lowest | 30 ₹745.8 |
| 3.00 | Scraping Cement plaster | 82.5 | sqm | 40 ₹3,300 Lowest | 45 ₹3,712.5 |
| 4.00 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. | 3.22 | cum | 6,600 ₹21,252 Lowest | 7,000 ₹22,540 |
| 5.00 | 12.5 mm thick cement plaster 1:4 | 164.76 | sqm | 220 ₹36,247.2 Lowest | 250 ₹41,190 |
| 6.00 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. | 32.05 | sqm | 580 ₹18,589 Lowest | 580 ₹18,589 Lowest |
| 7.00 | Cold Twisted Deformed Bars Fe500 Grade as per ( IS 1786-2008 ) for RCC works | 2.5 | qtl | 8,200 ₹20,500 Lowest | 8,200 ₹20,500 Lowest |
| 8.00 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. | 3.67 | cum | 6,200 ₹22,754 Lowest | 6,200 ₹22,754 Lowest |
| 9.00 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying Acrylic wall putty on new plastered surface.Complete as per specifications | 164.76 | sqm | 130 ₹21,418.8 Lowest | 130 ₹21,418.8 Lowest |
| 10.00 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade | 164.76 | sqm | 80 ₹13,180.8 Lowest | 80 ₹13,180.8 Lowest |
Tender Value
₹2.7 L
EMD Value
₹5,338
Closing Date
23 Oct 2025, 10:00 amClosed
Xen Fazilka Canal And Ground Water Division CC FZR
Xen Fazilka Canal And Ground Water Division CC FZR
Estimate For Regulator and Renovation of Gauge Hut at Bikaner Canal.
2025_WR_148164_2
007/FazilkaCanal/2025-26 dated 22/08/2025
Open Tender
Civil Works - Canal
Item Wise
Xen Fazilka Canal And Ground Water Division CC FZR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹5,338
13 Apr 2026
25 Aug 2025
23 Oct 2025
25 Aug 2025
23 Oct 2025
25 Aug 2025
Amount
Stripping and stacking slate or tiles of a roof.
Add for planks and battens in case of items nos 8.10 and 8.11
Scraping Cement plaster
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level.
12.5 mm thick cement plaster 1:4
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Cold Twisted Deformed Bars Fe500 Grade as per ( IS 1786-2008 ) for RCC works
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying Acrylic wall putty on new plastered surface.Complete as per specifications
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Factory manufactured solid flush door fixed in position ironhinges,etc(excluding the cost of any fittings other than specifiedabovebut including labour for fixing thesame in position (Code : IS 2202-1 (1999): ( 35 mm Thick )
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and with stone aggregate 40mm and 100mm fine sand filling using mechanical mixer for mixing of material
Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
Providing and laying vitrified floor tiles indifferent sizes in light colour shades made using Soluble Salt Technology (thickness tobe specifiedby the manufacturer) with water absorption’s less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement:4 fine sand), complete. ( Soluble salt Print Penetration should be up to 1 to2 mm after the tiles are fired & polished ). (a) 600 x 600mm
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
Providing and fixing 110 mm dia. U.P.V.C Rain water pipe of 4.0 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. Welding by gas or by electric plant,
Providing & fixing 16 gauge stainless steel pipe gate of grade 304 duly fixed at site with the help of M.S pivot & hinges grouted in cement concrete complete in all respect as per any kind of drawing & design
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, She plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (with fan box)
wiring light point
wiring 6 amp wall socket point
wiring 16/20 amp power plug control point
Supply and erection of Miniature Circuit Breaker MCB‘s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB‘s/ RCBO‘s/ RCCB‘s: Supplyanderectionof sheet metal Double Door Distribution Boards IP 43 IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wireset, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO‘s/ RCCB‘s in the distribution board (For SP&Ndistributionboardwith provisionDPMCB‘s/ RCCB‘s/ RCBO‘s as incomer and SP MCB‘s as outgoings and for TP&N horizontal distribution boardwithprovisionTPN/FP MCB‘s/ RCCB‘s/ RCBO‘s as incomer and SP MCB‘s as outgoings) as per PW General specifications including connections with suitable size of thimbles and bondingtoexistingearthetc: SP&N Double Door Distribution Board 8 way each
OVER HEAD DISTRIBUTION ALUMINIUM CABLES, ACSR CONDUCTORS, CLAMPS, JUMPERS & JOINT KITS: Wiring over-head line in PVC insulated & PVC sheathed two single core aluminium conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia. (14 SWG) with brass/ aluminium link clips complete in all respect as approved and desired by the Engineer In-Charge at site. PVC insulated & PVC sheathed aluminium conductor cable Overall Size 10mm² (1/1.40mm) Twin Core
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 2Core
Overall size 4.0sq.mm (56/0.3mm), 2Core
Any Other Item
G M DEVELOPERS GROUP (BID ID -691451)
stage.html
html • 0.04 MB
techsummary_299773.pdf
BOQ Comparative Chart
xlsx
finsummary_299773.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
ilovepdf_merged.pdf
Tender Documents • 15.96 MB
BOQ_299773.xls
BOQ • 0.28 MB
Corrigendum_007_10.pdf
PDF • 0.08 MB
Corrigendum_007_09.pdf
PDF • 0.08 MB
Corrigendum_007_08.pdf
PDF • 0.08 MB
Corrigendum_007_07.pdf
PDF • 0.08 MB
Corrigendum_007_06.pdf
PDF • 0.16 MB
Corrigendum_007_05.pdf
PDF • 0.16 MB
Corrigendum_007_04.pdf
PDF • 0.18 MB
Corrigendum_007_03.pdf
PDF • 0.17 MB
Corrigendum_007_02.pdf
PDF • 0.17 MB
Corrigendum_007_01.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .