| 1 | L1₹4.0 CrAdmitted-Finance | ₹4.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.0 CrAdmitted-Finance 102 R RESIDENCY PLOT 39 SEC 19 BEHIND HOTEL MALWAN ULWE NODE NAVI MUMBAI | NAVI MUMBAI | MAHARASHTRA | ₹4.0 Cr | L2 | Admitted-Finance |
| 3 | L3₹4.3 CrAdmitted-Finance | ₹4.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹4.8 CrAdmitted-Finance 233 PLATINUM PLAZA OPP IOCL PUMP NR JUDGES BUNGLOW CROSS ROAD BODAKDEV AHMEDABAD GUJARAT 380054 | AHMADABAD | GUJARAT | 380054 | ₹4.8 Cr | L4 | Admitted-Finance |
| 5 | L5₹5.8 CrAdmitted-Finance OFFICE NO 208 B WING 2ND FLOOR GROMA HOUSE PLOT 14C SECTOR 19 VASHI NAVI MUMBAI VASHI NAVI MUMBAI MAHARASHTRA 400705 UDYAM MH 19 0041442 | THANE | MAHARASHTRA | 400705 | ₹5.8 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | aselectric corporation L1 | Yogiraj Powertech Pvt Ltd. L5 | GEETU ENGINEERING AND CONSTRUCTIONS PVT. LTD. L3 | EVERCREST PROJECTS PVT LTD. L4 | OM POWER SYSTEMS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Design, manufacture, supply, installation, testing and commissioning of 11kV/433V, 1250 kVA hermetically sealed ONAN transformer for outdoor application, complying IS-2026 and IS-1180 (latest) and as per technical specifications | 2 | SET | 42,35,000 ₹84.7 L | 43,92,000 ₹87.8 L | 42,50,000 ₹85 L | 35,64,000 ₹71.3 L | 46,18,750 ₹92.4 L |
| 2.00 | Design, manufacture, supply, installation, testing and commissioning of 11kV/433V, 1000 kVA dry type cast resin transformer for indoor application, complying with IS-2026 (latest) and IS-11171 (latest) and as per technical specifications | 2 | SET | 34,26,500 ₹68.5 L | 45,25,000 ₹90.5 L | 37,50,000 ₹75 L | 33,83,000 ₹67.7 L | 38,31,250 ₹76.6 L |
| 3.00 | HT Switchgear panels: Design, manufacture, supply, installation, testing and commissioning of 11kV VCB based compartmentalized HT panel as per technical specifications | 1 | SET | 33,56,100 ₹33.6 L | 1,10,94,000 ₹1.1 Cr | 52,50,000 ₹52.5 L | 80,36,374 ₹80.4 L | 62,71,250 ₹62.7 L |
| 4.00LT switchgear panels. Design, manufacture, supply, installation, testing and commissioning of LT switchgear panel as per technical specifications and the following schedule. | ||||||||
| 4.10 | LT panel as per technical specifications | 1 | SET | 72,65,500 ₹72.7 L | 96,49,000 ₹96.5 L | 77,50,000 ₹77.5 L | 1,07,52,272 ₹1.1 Cr | 59,54,000 ₹59.5 L |
| 5.00 | 11kV, XLPE cable. Supply, installation, testing and commissioning of 11 kV-6.35 kV(UE), 3C x 400 sq.mm Aluminium conductor XLPE insulated, armored, sheathed cable as per technical specification | 350 | M | 5,055 ₹17.7 L | 5,097 ₹17.8 L | 2,800 ₹9.8 L | 4,262 ₹14.9 L | 1,500 ₹5.3 L |
| 6.00LT cable Copper conductor. Supply, installation, testing and commissioning of 1.1 kV grade multistrand copper conductor XLPE insulated FRLS cable as per IS-7098-1 and corresponding to technical specifications and following schedule | ||||||||
| 6.10 | 4 C x 2.5 sq.mm control cable on surface | 500 | M | 338 ₹1.7 L | 404 ₹2.0 L | 285 ₹1.4 L | 286 ₹1.4 L | 200 ₹1 L |
| 6.20 | 4 C x 2.5 sq.mm control cable in ground | 100 | M | 338 ₹33,800 | 404 ₹40,400 | 400 ₹40,000 | 346 ₹34,600 | 200 ₹20,000 |
| 6.30 | 10 C x 2.5 sq. mm control cable on surface | 300 | M | 738.1 ₹2.2 L | 759 ₹2.3 L | 570 ₹1.7 L | 608 ₹1.8 L | 450 ₹1.4 L |
Tender Value
₹4.0 Cr
EMD Value
₹9.4 L
Closing Date
5 Feb 2026, 6:00 pmClosed
Chief Engineer and Head, CSD, ESG, BARC
Office of Chief Engineer and Head CSD, PG Hostel, Anushaktinagar, Mumbai-400094
Upgradation of substation at old BARC hospital building, Anushaktinagar, Mumbai.
2026_BARC_895226_1
BARC/CSD/ET/38/2025-2026
Open Tender
Electrical Works
548 days
BARC Hospital, Anushaktinagar
As per NIT
3 documents required · 3 mandatory
₹0
₹9.4 L
CSD office, PG hostel, Anushaktinagar
10 Apr 2026
22 Jan 2026
9 Feb 2026
22 Jan 2026
5 Feb 2026
22 Jan 2026
22 Jan 2026 - 29 Jan 2026
30 Jan 2026
Design, manufacture, supply, installation, testing and commissioning of 11kV/433V, 1250 kVA hermetically sealed ONAN transformer for outdoor application, complying IS-2026 and IS-1180 (latest) and as per technical specifications
Design, manufacture, supply, installation, testing and commissioning of 11kV/433V, 1000 kVA dry type cast resin transformer for indoor application, complying with IS-2026 (latest) and IS-11171 (latest) and as per technical specifications
HT Switchgear panels: Design, manufacture, supply, installation, testing and commissioning of 11kV VCB based compartmentalized HT panel as per technical specifications
LT switchgear panels. Design, manufacture, supply, installation, testing and commissioning of LT switchgear panel as per technical specifications and the following schedule.
LT panel as per technical specifications
11kV, XLPE cable. Supply, installation, testing and commissioning of 11 kV-6.35 kV(UE), 3C x 400 sq.mm Aluminium conductor XLPE insulated, armored, sheathed cable as per technical specification
LT cable Copper conductor. Supply, installation, testing and commissioning of 1.1 kV grade multistrand copper conductor XLPE insulated FRLS cable as per IS-7098-1 and corresponding to technical specifications and following schedule
4 C x 2.5 sq.mm control cable on surface
4 C x 2.5 sq.mm control cable in ground
10 C x 2.5 sq. mm control cable on surface
10 C x 2.5 sq. mm control cable under ground
4 C x 4 sq. mm. cable on surface
LT cable Aluminium conductor: Supply, installation, testing and commissioning of following 1.1 kV multistrand Aluminium conductor XLPE insulated FRLS cable as per IS-7098-1 and corresponding to technical specifications and following schedule
3.5C X 70 sq.mm cable on surface
3.5C X 120 sq.mm cable on surface
3.5C X 185 sq.mm cable on surface
3.5C X 185 sq.mm cable in ground
3.5C X 300 sq.mm cable on surface
3.5C X 300 sq.mm cable in ground
Straight through joint/ end termination of HT Cable: Straight through jointing/End termination (Indoor) of 3C x 400 sq.mm Aluminium conductor XLPE cable using heat shrinkable termination kit as per technical specification.
11kV, 3C x 400/300 sq.mm straight through joint
11kV, 3C x 400 sq.mm end termination
11kV, 3C x 120 sq.mm straight through transition joint from existing PILC to XLPE cable
LT Cable Straight joint for aluminium conductor cable as per specification corresponding to the following schedule.
4C X 25 sq.mm cable
3.5C X 70 sq.mm cable
3.5C X 185 sq.mm cable
3.5C X 300 sq.mm cable
3.5C X 400 sq.mm cable
LT Cable End termination: End termination for aluminium conductor/Copper conductor 1.1 kV grade power/control cable as per technical specification and corresponding to the following schedule.
4C X 25 sq.mm Al power cable
3.5C X 70 sq.mm Al power cable
3.5C X 185 sq.mm Al power cable
3.5C X 300 sq.mm Al power cable
3.5C X 400 sq.mm Al power cable
4C X 2.5 sq. mm copper control cable
10C x2.5 sq. mm copper control cable
Removal of cable end termination from various PCC panels as per technical specifications and the following schedule
3.5C X 70 sq.mm power cable
3.5C X 95 sq.mm power cable
3.5C X 185 sq.mm power cable
3.5C X 300 sq.mm power cable
3.5C X 400 sq.mm power cable
4 Cx 4 sq. mm cable for dc bus voltage
Earth Conductor: Supply and installation of copper earth strip/wire of following sizes to be installed in trenches, wall, RCC, slab, above false ceiling etc. as per specification corresponding to specification schedule.
50 x 6 mm tinned copper strip
25 x 3 mm tinned copper strip
Earth stations: Supply, installation, testing and commissioning of 600 x 600 x 3.15 mm thick tinned copper earth plate as per IS: 3043 complete with all required materials as per specification corresponding to Specification Schedule.
Battery charger with battery: Supply and installation of battery charger with battery bank as per technical specifications.
Removal of cables of following sizes as per specifications
Up to 6 sq.mm
Above 6 sq.mm and up to 25 sq.mm
Above 25 sq.mm and up to 240 sq.mm
Above 240 sq.mm and up to 400 sq.mm
Dismantling, transportation, packing and safe disposal of the following items as per technical specifications and the following schedule
11 kV 400 A MOCB based HT panel along with removal of all cable terminations, earthing strips, switchgears, bus bars, relays, metering and instrumentation items, base channels etc.
415 V 1250A LT PCC panel along with removal of all cable terminations, earthing strips, switchgears, bus bars, relays, metering and instrumentation items, base channels etc.
11 kV/433 V 800 kVA ONAN type outdoor distribution transformer along with removal of end terminations of all cables from cable boxes, removal of neutral earthing, plinth foundational grouting etc.
11 kV/433 V 750 kVA ONAN type indoor distribution transformer along with removal of end termination of all cables from cable boxes, removal of neutral earthing, plinth foundational grouting etc.
Existing 400A 3 way RMTs inside the transformer room along with removal of end terminations of all incoming and outgoing cables, foundations, earthing strips etc.
Supply, fabrication and installation of various items made from MS as per technical specifications and following schedule
MS Box: Supply & installation of MS boxes fabricated out of powder coated MS sheets as per tender specification
M S Items- Supply & installation of MS items fabricated from channel/angles/Plate/pipe etc as per tender specification.
Only installation of 300 mm wide cable tray as per attached specifications.
Supply, installation, testing and commissioning of electrical insulation mats as per specification (IS-15652) and corresponding to following Schedule.
Class B insulation mats rated for voltage up to 22 kV
Excavation as per technical specifications and the following schedule
Excavation in soft soil
Excavation in murram/ hard soil
Excavation through asphalt road/ RCC floor
Core cutting in RCC walls/trenches as per technical specifications and the following schedule
Core size: 250 mm diameter
Core size: 300 mm diameter
Casting of Plain concrete cement (Cement:Sand:Graded stone-1:2:4) as per technical specifications
Fabrication, filling and casting of reinforced concrete cement as per technical specifications
Supply and installation of heat shrinkable sleeves for earthing conductors used for neutral grounding of all the transformers as per technical specifications
Only installation of 1.1 kV 3.5C x 400 Sq. mm Aluminium conductor, XLPE insulated, armoured, FRLS cable from cables tray, trenches, wall etc as per attached specifications.
Supply, installation, testing and commissioning of MCCBs placed inside powder coated MS enclosures as per technical specifications and following schedule
4 pole 400 A microprocessor based MCCB with O/L, S/C and E/F protection inside box
Supply, installation of 250 mm dia RCC Hume Pipe as per specifications
Supply and installation of various types of cable trays as per following schedule and technical specifications
450x75 mm perforated type cable trays with all accessories required for installation
450x75 mm ladder type cable trays with all accessories required for installation
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_940972.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 11.09 MB
Tender_document_CSD_ET_38.pdf
Tender Documents • 1.12 MB
TECHNICAL_BID_BARC_CSD_ET_38_2025_2026.xls
Additional Documents • 0.27 MB
Schedule_A_38.pdf
Additional Documents • 0.67 MB
BOQ_940972.xls
BOQ • 0.34 MB
Proforma_of_schedules.pdf
Additional Documents • 0.38 MB
Schedule_of_specifications_and_payment.pdf
Additional Documents • 0.22 MB
Specifications_csd_et_38.pdf
Additional Documents • 1.15 MB
Annexures.pdf
Tender Documents • 0.46 MB
Download all tender documents and submit your bid