| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.9 L+₹26,834.60 (4.07%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
19 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bhisiana
Military Engineer Services, Garrison Engineer (AF), Bhisiana, Bathinda-151201
Provn of certain B/R and E/M Minor Works at AF Stn Bhisiana
2022_MES_501507_1
GE/BHI-66/2021-22
Open Tender
Miscellaneous Works
Item Rate
30 days
GE (AF) Bhisiana
Please Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Bhisiana
₹14,000
Yes
26 Feb 2022
13 Jan 2022
21 Feb 2022
13 Jan 2022
19 Feb 2022
5 Feb 2022
14 Jan 2022 - 21 Jan 2022
60 days
Amount
SCHEDULE 'A', PART-I
M&L cutting holes in brick walls, exc. half brick thick but not exc. one brick thick, built in cement mortar for inserting of cooler stand, Lugs etc and making good to dismantled portion with Cement Concrete 1:2:4 (20mm graded stone aggregate) or Cement Mortar 1:3 (as required) and adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed.
Taking down damaged/unserviceable Steel/PVC Chowkat or Frame not exc. 1.50 Square Metre Each with shutter (without taking off shutter from the frame), complete all as specified and as directed.
Demolition Brick work built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Rendering (Internal) 15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, Plastered Surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.
S&F anodised Powder Coated (minimum thickness of Powder Coating is 50 micron) Aluminium Frame for Doors, Windows, Ventilators with one or more Rebates including Jointing Cleat for fixing, incl taking down existing frame etc., complete all as specified and as directed. Note: (a) The rates include for provision of PVC protected sheeting and its removal after fixing the frame work. (b) Hinges, shutters and lugs shall be measured and paid for separately.
S&F aluminium anodized Powder Coated (minimum thickness of Powder Coating 50 micron) Door Shutter weighing 0.55 kg per meter including necessary Jointing Cleats, Glazing Clips, Rubber Packing, Aluminium Snap Beading and Fixing Accessories including Locking Arrangements, fixed with Aluminium Hinges to the Frame or Slidding type or Pull & Push type Shutter including Aluminium anodized Fittings such as Handle of size 150mm (2 Nos), Mild Steel Mortice Lock of size 100mm, 4 Lever (1 No.) including necessary Fittings and Fixtures, complete all as specified and as directed. Note : Cost of Jointing & Packing Materials, Aluminium anodized fittings, etc will deem to be included in the Quoted Unit Rate.
S&F Aluminium anodised Powder coated security/window grill (as approved) mesh of size 50mmx50mm thickness 3.8mm thick made out of anodised aluminium section with aluminium frame including necessary accessories for fixing etc, complete all as specified and as directed.
M&L for 12 mm thick pre-laminated particle boards exterior grade both sides laminated, Medium density including fixed to frame work in partitions, frame, shelves etc complete all as specified and as directed.
S&F 5.5 mm thick black Tinted glass with rubber gasket in square not exceeding 0.5 Sqm in each pane, complete all as specified and as directed.
S&F Double Action Floor Spring Hydraulically Regulated made up of minimum 1.25mm thick Aluminium alloy Sheet Foundation Box, Main Body with Stainless Steel Cover, Governing Pivot made of Brass, Other Parts made of Mild Steel heavy duty, complete all as specified and as directed.
S&F in repair Door Closer Aluminium (Die cast) body, hydraulically regulated, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in width and of weight between 61.00 to 80.00 Kilogram, complete all as specified and as directed.
Excavating in Post Holes (or similar holes) in Hard/Dense Soil, Each not exc. 0.50 Cum, getting out, returning, filling in and ramming Earth or Broken Rubble mixed with Earth around in layers not exc. 25 CM, watering and removing surplus Soil to a distance not exc. 50.00 Metre and making good surface, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 type C-1 (20mm graded stone aggregate) in Post Holes, etc. including use and waste necessary formwork (as ordered/required at Site), complete all as specified and as directed.
S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410 (Gde E-250), complete all as specified and directed.
S&F pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Pitch 190mm, depth 29mm and Tensile strength of 550 Mpa as in Roof Covering, the sheet shall have a hot dip metallic zinc aluminium alloy coationg of zinc 43.5%, aluminium 55% and silicon 1.5% with total mass coating of 150 gm/sqm on both sides having covered width 1020mm and return leg for proper side lap and fixed with self drilling/ capping screws with EDPM seal as in Ridges/ Hips/ Valley's complete all as specified and directed.
Preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L for preparation of new plastered/ Previously untreated surfaces and applying two coats of cement base paint on walls, pillars cornices over a coat of alkali resistant primer of same make complete all as specified and as directed.
M&L Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes including Bolts, Hooks (Stay) for large Gates; Hook and Pintle Hinges: large Hasps and Staples; Hand Made Sliding Bolts; Clamps; Holdfasts; Wall Ties; Hooks for hangings fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; Two way and Three way straps, plate washers and similar small Articles conforming to Fe-290 Gde-E-165, complete all as specified and as as directed.
M&L Framed Work as in Doors or Gates of Angle or Other Section with Gusset Plates, Rails, Braces, etc., drilled for fixing of Steel Sheeting or Other Covering. Doors, etc. to be prepared for hanging or sliding with and including either Hooks and Hinges or Steel Hanging Door Fittings (exclusive of Steel Sheeting or Other Covering, Running Rails and Guides) and hanging; also fastening and fixing, conforming to Fe-410-W (Gde E-250), Quality A, complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth in soft/loose soil for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc, complete all as specified.
Returning filling in trenches including spreading, leveling, watering and well ramming complete.
Removal of surplus excavated soil not exc 50m distance and deposited where directed.
Plain cement concrete (1:4:8) type D2, using 40 mm graded stone aggregate in foundation, filling and mass concrete complete all as specified and directed.
M & L for Damp proof Course in Cement concrete1:2:4 type B0 ,25mm thick with using of water proofing compound 3% weight of cement.
M&L hard core of guage n.exc 63mm deposited spread and level laid in layers n.exc 15cm thick, watered and rammed to a true surface of broken stone boulders.
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cemetn mortar 1:4
M & for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 159, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
Material and labour for 15mm thick cement plaster in CM (1:4) on fair/other then fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified and as directed.
M & L rendeing 15mm thick cement plaster on fair faces of brick or concrete surface in CM 1:6 and and finishing the surface even and fair complete all as specified and directed.
Rendering cement plaster 5mm thick in cement mortar 1:4 on ceiling of concrete surface finished even and smooth with out using extra cement.
M&L for form work to soffits and sides of suspended slabs such as roof slab n.exc 200 mm thick (Horizantal or sloping).
M&L for RCC 1:2:4 type B-1 (20 mm graded agg) (Nominal mix) as in roof slab etc.
Supply only integral water proofing compound.
TMT steel bars 10 mm dia and over cut to length bent to shape required including cranking, bending spirally,for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or squaring with clips.
TMT Bars 6 to 8 mm dia cut to length bend to shape required, including cranking bending spirally for hooping for columns, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified.
M&L for 10mm thick cement plaster in cement mortar 1:3, including finishing even and smooth with out using extra cement mixed with water proofing compound when concrete is green, as per manufacturere instructions complete all as specified. (Note - Water proofing compound shall be measured and paid separately).
M & L preperation of new plastered surfaces and applyingTwo coats of cement base paint over a coat of chalkwhitening complete all as specified and as directed.
M & L for two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surface incl necessary preparation.
M&L for two coats of white washing on ceilings of of newly plastered surface incl necessary preparation.
M&L PCC (1:4:8) type D-2 using 40mm graded agg as in sub base of floor 75mm thick.
M&L 40mm th PCC (1:2:4) type B-1 using 20mm graded agg as in base of floor Finishes.
Material and labour for Screed bed or bedding layer of mortar (1:6) ,15 mm thick for laying floor finishes complete all as specified and as directed.
Material and labour Rendering 10 mm thick cement plaster 1:3 on fair faces of brick work or concrete surfaces, including finishing the surfaces even and fair to receive the wall tiles etc all as specified and as directed.
Material and labour Coloured joint free Non Skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles of size 350mmx250mmx7 mm / 450/350/7mm thick thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles compete all as specified and as directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long complete all as specified and as directed by Engineer-in-charge.
S&F 75mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) but as in repairs.
S&F 75mm bore( Sand Cast )Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints , laid in trenches or in floors but as in repairs.
Material and labour 15 mm dia tubes medium grade galvanised with all fitting and fixed to walls and ceilings or laid in floors complete all as specified.
Material and labour 20 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings complete all as specified.
S&F Vitreous China ware wash down water closet (Pedestal), white (EWC) including seat cover with brass screws and excluding flush pipe and flushing cystren including concrete complete including making good to floor.
Material and labour Flush pipe of Polyethylene of low or high density or PVC 32 mm dia, for low level cistern.
S&F plastic water closet seat cover white close pattern with flat bottom and cover complete all as specified as direected.
S&F 10 Liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or PVC 32 mm dia connections pipe complete. Make : CERA/PRAYAG/HINDUSTAN.
S&F Vitreous China WHB white flat back size 550 x 400 mm including brackets, 32 mm dia waste fittings brass CP for WHB & CP pillar tap, sink etc with long shank screwed and fly nuts , flags and bedded in red lead cement and outer end fixed complete all as specified and as directed by Engineer-in-Charge.
S&F 15mm dia Pillar taps fancy type cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and flu-nuts screwed for iron pipe.
S&F 15 mm bore Stop Valve fancy type chromium plated with long shank and cup (concealed type) ,cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed in repairs.
S&F 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F PVC connections 15 mm size with PTMT nuts of length 450mm.
S&F Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges.
S&F steel ventilator glazed & gauged factory made with top hung type shutters including hinges and steel handle and steel peg stay, including supply and fixing stainless steel wire cloth 1.14mm dia and 3mm thick glass fixing with putty and glazed pins and necessary grills and guard bars complete and making good the disturbed portion with PCC or Plaster and painting the surface to match with the existing surface complete all as specified and as directed.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawing.
Factory made solid panel PVC door shutter 30mm thick (stile), consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification and drg.
100mm size PVC butt hinges all as specified. (Make : Prayag/ Raj Shree/Sintex).
100mm size PVC handles all as specified and directed (Make : Prayag/ Raj Shree/Sintex).
150mm long PVC tower bolt all as specified and directed. (Make : Prayag / Raj Shree/Sintex).
SCHEDULE 'A', PART-II
M&L for concealed Point Wiring using approved Colour Code as per IS with Zero hologen Flame Retardent (HFFR) Smoke Free, Non-toxic, Non-corrosive with Copper Conductor Cable 1.5 Sqmm (nominal area) confirming to IS : 694 nominal area single core insulated and unsheated stranded cable 1100 volt grade with Earth Continuity Cable drawn in new ERW concealed conduit heavy duty of any description suitable for LIGHT/FAN Point and Making Good the disturbed surfaces of Walls, Celings, etc. (as per Site requirement), complete all as specified and as directed.
S&F Switch Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Single Pole, 250 Volt complete all as specified and as directed.
S&F Falme Proof cum Water Proof LED Bulk Head fitting of 60 W IP 66 protecting of casr aluminium alloy material and heat impact resistance toughen "A" clear glass having anti corrosive epoxy powder coated finish with all accessories uncluding connecting up with three core flexible copper conductor cable of suitable size, complete all as directed by Engineer-in-Charge.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body, complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of Servo Controlled Voltage stabilizer for automatic operation, Three phase, 50Hz copper wound naturally Oil cooled indoor type,Unabalanced, metallic body duly powder coated with lifting hooks two nos of capacity 50KVA having following specifications:- (a) Input Voltage 340V-460V. (b) Output Voltage Stablized at any designed/desired Voltage 415V ± 1.0% (c) Rated frequency 50HZ. (d) No distortion in wave form.
Supply & Fixing/Laying XLPE insulated screened PVC bedded, armoured heavy duty Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross sectional area 50 Sqmm 3½ Core including necessary Aluminium Thimbles, jointing and Testing, complete all as specified as and directed.
Supply, Installation, Testing and Commissioning of Servo Controlled Voltage stabilizer for automatic operation, Three phase, 50Hz copper wound naturally Oil cooled indoor type, Unbalanced, metallic body duly powder coated with lifting hooks two nos of capacity 25KVA having following Specifications:- (a) Input Voltage 340V- 460V. (b) Output Voltage Stablized at any designed/desired Voltage 415V ± 1.0% (c) Rated frequency 50HZ. (d) No distortion in wave form.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No. 3 of MES SSR Part-I and testing on completion including necessary excavation and earth work in any type of soil, PCC (1:3:6) type C-1 chamber, pre-cast RCC slab 50mm thick in cement concrete (1:2:4), type B1, reinforced with welded steel wire fabric or XPM, (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, GI protection pipe,15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
M&L submain wiring with 2 runs of copper conductor PVC FR insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site. Note : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one unit (Running meter).
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 CM in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 CM Spread thickness (8 CM in depth before laying the Cable and 15 CM in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for PCC cable protection cover in replacement, Class LV, Type 1, Flat of size 230 mm x 115mm x 75mm for LT UG cable and gap between adjacent cover not exc 10mm complete all as specified and directed.
Supply, installing, testing and commissioning factory made LT feder pillar box outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators, The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200 Amps including 1 No MCB SPN 06 Amps on suitable foundation.
Note:- (a) If same items repeated erouneously at two serial number. The lowest rate quoted is considered for Acceptance (b) Bidder shall quote rate according to the Make mentioned in BOQ/Appendix 'A' of Particular Specification.
Aman Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .