Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹48.7 L+₹4.8 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹49.4 L+₹5.5 L (12.6%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹50.5 L+₹6.6 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹50.7 L+₹6.8 L (15.6%)Rejected-Finance AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | L5 | Rejected-Finance Being higher bid value |
| Sl No | Description | Qty | Unit | KRISHNA ENTERPRISES L3 | ELECTRO COMMERCIAL CO L6 | Rounaq Enterprise L1 | M/SNeelachal Enterprises L7 | chauhan syndicate L4 | ALLIANCE L2 | DS ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Labour only for Pressure testing / leak arresting with dry nitrogen gas / oil charging vaccumising, incl replacing the unserviceable strainers all as required and testing complete for the Central type AC plant of capacity 24 to 30 TR Plants.
Note :- Refregerant Gas, strainers will be measured and paid seperately under supply only items | 2 | Each Job | 8,000 ₹16,000 Lowest | 8,600 ₹17,200 | 8,250 ₹16,500 | 8,700 ₹17,400 | 8,100 ₹16,200 | 8,220 ₹16,440 | 8,000 ₹16,000 Lowest |
| 2.00 | All as per as above item no 1 here -in-before but for Central type AC plant of capacity 75 to 90 TR ITR tech area. | 2 | Each Job | 11,200 ₹22,400 | 13,700 ₹27,400 | 11,000 ₹22,000 | 14,555 ₹29,110 | 13,300 ₹26,600 | 10,690 ₹21,380 Lowest | 11,000 ₹22,000 |
| 3.00 | All as per as above item no 1 here -in-before but for Package type AC plant of capacity 5.5 TR to 16.5 TR at any location/building of ITR tech area | 9 | Each Job | 6,200 ₹55,800 | 6,600 ₹59,400 | 6,000 ₹54,000 | 6,450 ₹58,050 | 5,885 ₹52,965 Lowest | 6,320 ₹56,880 | 7,000 ₹63,000 |
| 4.00 | Supply only for Recharge/Top up refrigerant R- 22 in Central/Package type AC Plants of various capacities complete all as directed . | 165 | Kg | 1,750 ₹2,88,750 | 1,820 ₹3,00,300 | 1,500 ₹2,47,500 Lowest | 1,688 ₹2,78,520 | 1,725 ₹2,84,625 | 1,900 ₹3,13,500 | 2,000 ₹3,30,000 |
| 5.00 | Supply only for Recharge/Top up refrigerant R- 410/413/407C/R134a or equivalent in various type of Package/Central type AC Plants of various capacities complete all as directed . | 240 | Kg | 1,735 ₹4,16,400 | 1,685 ₹4,04,400 | 1,450 ₹3,48,000 Lowest | 1,650 ₹3,96,000 | 1,629 ₹3,90,960 | 1,850 ₹4,44,000 | 2,000 ₹4,80,000 |
| 6.00 | Supply and charging/top up of compressor oil in reciprocating type central AC plants, Type : HPL-68 or equivalent as per existing sample
(Make : SERVO/INDIAN OIL or equivalent as approved) | 90 | Ltr | 700 ₹63,000 | 730 ₹65,700 | 600 ₹54,000 Lowest | 733 ₹65,970 | 730 ₹65,700 | 720 ₹64,800 | 700 ₹63,000 |
| 7.00 | Supply and charging/top up of compressor oil in Screw type central AC plants, HBR-B08 as per existing sample | 40 | Ltr | 2,800 ₹1,12,000 | 3,225 ₹1,29,000 | 2,700 ₹1,08,000 Lowest | 3,000 ₹1,20,000 | 3,300 ₹1,32,000 | 2,900 ₹1,16,000 | 3,000 ₹1,20,000 |
| 8.00 | Supply and charging/top up of compressor oil in scroll type central AC plants, 160P or equivalent as per existing sample | 20 | Ltr | 2,160 ₹43,200 | 2,475 ₹49,500 | 2,100 ₹42,000 Lowest | 2,500 ₹50,000 | 2,300 ₹46,000 | 2,550 ₹51,000 | 2,500 ₹50,000 |
| 9.00 | Supply, Fabricate and fixing of MS angle/MS plate/flat/rod for cooling tower frame, CT fan base, cooling tower ladders, and all supports made out of suitable size along with welding/MS nuts, bolts and washers, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted one, complete all as specified and directed by Engineer-in-Charge | 140 | KG | 257 ₹35,980 | 275 ₹38,500 | 225 ₹31,500 Lowest | 280 ₹39,200 | 285 ₹39,900 | 270 ₹37,800 | 300 ₹42,000 |
| 10.00 | M&L for repair to damage fiber of cooling tower by necessery cutting and patch work by casting to match the existing complete all as specified and directed. | 8 | Sqft | 2,700 ₹21,600 | 3,010 ₹24,080 | 2,500 ₹20,000 Lowest | 3,999 ₹31,992 | 2,870 ₹22,960 | 2,790 ₹22,320 | 3,000 ₹24,000 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
17 Sept 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
GE (I) R and D Chandipur, Post-Chandipur, PIN-756025
REPAIR / REPLACEMENT TO CENTRAL AND PACKAGE TYPE AIR CONDITIONING PLANTS DUCT LINE AND ALLIED WORK AT ITR TECH AREA AT CHANDIPUR
2026_MES_785410_1
8318/A
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandipur
As per NIT
9 documents required · 9 mandatory
₹500
GE (I) R and D Chandipur
₹90,000
Yes
4 Nov 2026
20 Aug 2026
24 Sept 2026
20 Aug 2026
17 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour only for Pressure testing / leak arresting with dry nitrogen gas / oil charging vaccumising, incl replacing the unserviceable strainers all as required and testing complete for the Central type AC plant of capacity 24 to 30 TR Plants.
Note :- Refregerant Gas, strainers will be measured and paid seperately under supply only items | 2 | Each Job | - | - |
| 2 | All as per as above item no 1 here -in-before but for Central type AC plant of capacity 75 to 90 TR ITR tech area. | 2 | Each Job | - | - |
| 3 | All as per as above item no 1 here -in-before but for Package type AC plant of capacity 5.5 TR to 16.5 TR at any location/building of ITR tech area | 9 | Each Job | - | - |
| 4 | Supply only for Recharge/Top up refrigerant R- 22 in Central/Package type AC Plants of various capacities complete all as directed . | 165 | Kg | - | - |
| 5 | Supply only for Recharge/Top up refrigerant R- 410/413/407C/R134a or equivalent in various type of Package/Central type AC Plants of various capacities complete all as directed . | 240 | Kg | - | - |
| 6 | Supply and charging/top up of compressor oil in reciprocating type central AC plants, Type : HPL-68 or equivalent as per existing sample
(Make : SERVO/INDIAN OIL or equivalent as approved) | 90 | Ltr | - | - |
| 7 | Supply and charging/top up of compressor oil in Screw type central AC plants, HBR-B08 as per existing sample | 40 | Ltr | - | - |
| 8 | Supply and charging/top up of compressor oil in scroll type central AC plants, 160P or equivalent as per existing sample | 20 | Ltr | - | - |
| 9 | Supply, Fabricate and fixing of MS angle/MS plate/flat/rod for cooling tower frame, CT fan base, cooling tower ladders, and all supports made out of suitable size along with welding/MS nuts, bolts and washers, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted one, complete all as specified and directed by Engineer-in-Charge | 140 | KG | - | - |
| 10 | M&L for repair to damage fiber of cooling tower by necessery cutting and patch work by casting to match the existing complete all as specified and directed. | 8 | Sqft | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.31 MB
SchofCredit_8318A.pdf
Additional Documents • 0.21 MB
Tender_Doc_8318A.pdf
Tender Documents • 0.78 MB
BOQ_880082.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .