Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹37.3 L+₹2.5 L (7.22%)Rejected-Finance KHATA NO 254 529 KHASRA NO 364 2 MIN PREET NAGAR A GALI NO 2 HARERI ROAD OPP STAR STUDIO HERARI SANGRUR | SANGRUR | SANGRUR | PUNJAB | L2 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
14 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
ADDN/ALTN TO CERTAIN TECHNICAL BLDGS IN OP COMPLEX AND CERTAIN MINOR WORKS AT AF STATION BARNALA UNDER GE AF HALWARA
2021_MES_460340_1
GE/HAL-33/2021-22
Open Tender
Civil Works
Item Rate
183 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY a i and b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹70,000
Yes
27 Aug 2021
16 Jul 2021
16 Aug 2021
16 Jul 2021
14 Aug 2021
30 Jul 2021
60 days
Amount
Surface dressing not exceeding 15cm deep as in soft/loose soil complete all as specified and directed.
Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide for foundations etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and getting out complete all as specified and directed. Notes : (i) Payment for excavation shall be made for one time in case the newcable is laid in the same trenches. (ii) Excavation upto top of brick protection shall be measured for payment purposes.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed.
M&L for hardcore of broken stone or boulders guages not exc 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to true surface complete all as specified and directed.
M&L for PCC 1:4:8 Type D-2 using 40mm crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L brick work with sub class B bricks, straight or curved on plan exc 6M mean radius built in cement mortar 1:6 all as specified.
M&L brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for 40mm thick damp proof course in PCC 1:2:4 Type B-0 (using 12.5mm graded stone aggregates) mixed with water proofing compound @ 3% by weight of cement to horizontal or vertical surfaces including use of necessary formwork complete all as specified and directed. Note : Water proofing compound shall be measured and paid separately as supply only.
Supply only integral water proofing compound
M&L for 10 mm thick plastering on fair faces of concrete/brick surfaces in CM 1:6 finished fair and even without using extra cement complete all as specified.
M&L for 15 mm thick plastering on fair faces of concrete/brick surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified.
M&L for 5mm thick plaster in cement mortar 1:3 as in ceilling,finishing the surfaces even and smooth w/o using extra cement.
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregates) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed
M&L for preparing new plastered surfaces of walls & applying two coats of oil bound distember over a coat of primer and a layer of wall puttty complete all as specified.
M&L for preparing new plastered surfaces of celling and applying three coats of white wash all as specified.
M&L for preparing new plastered surfaces of walls and applying three coats of white wash all as specified.
M&L for sand filling under floors including watering , consolidation and well ramming in layers complete all as specified and directed.
M&L for sand cushioning in trenches and well ramming in layers below and above the cable with fine dry sand for cable protection and complete all as specified and directed.
M&L for brick protection with sub class "B" bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable complete all as specified and directed specified .
M&L for cement concrete M-25 Grade (using 20mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, rooft, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Mild steel bars 10mm dia and over TMT bars cut to length bent to shape required including cranking ,bending spirally for hooping for columns hooking bends and binding with including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
Formwork to soffits of suppended slabs such as roof slab, floor slabs, landing and similar work not exc 200mm thick for rough finished surfaces of concrete flat complete all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 10cm wide but not exc 20 cm wide complete alll as specified and directed.
S&F Solid PVC door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube , suppling and fixing in opening asper specification and drawing .
S&F 30 mm factory made solid panel PVC door shutter consisting of frame made out of MS tube for top and bottom rail,MS frame shall be covered with heat moulded plain colour PVC “C” channel having stip of 20 mm width stuck inside with solvent cement rail on either side and as gap inset for top rail and bottom rail, welded/sealed to the stiles and railes with suitable PVC sheet beading and joined together with solvent cement supply and fixing in the frame and site as specification all as specified.
S&F factory made pressed steel frames made out from 1.25mm thick steel sheet for doors of size 105x60mm with one or more rebates including necessary fixing lugs,hinges, lock strike plate, one coat of red oxide primer etc, and including treated with tar or coal tar black paint on steel surfaces in contact/embeded in concrete or masonary work including filling hollow portion of frames with PCC 1:2:4 type B-0 (using 12.5mm gradced stone aggregates) complete all as specified and directed
S&F 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commerical ply or 12mm veneered particle board with commerical veneering on both faces. The size of rail and stiles as per IS : 1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F powder coated Anodised aluminium frame for doors, windows, ventilators or in partitions with one or more rebates including jointing cleats for fixing etc complete all as specified and directed
S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, handle 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
S&F cold rolled mild steel medium weight butt hinges 100mm size complete all as specified and directed.
S&F aluminimum anodised, barrel tower bolts of extruded section with length of bolt 200mm and fixed complete all as specified & directed.
S&F aluminimum anodised cast type handle of 150mm dia
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F aluminum (Extruded section body) door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width and fixed complete all as specified and directed.
S&F 9mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations, fixed in aluminum partitions with screws complete all as specified and directed.
Preparation of new wood surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F steel ventilators with top hund shutter including MS peg stay complete all as specified and directed.
S&F 15mm bore galvanized iron tubes medium grade with all fitting and fixed complete to walls, ceiling or laid in floor complete all as specified and directed.
S&F 20mm bore galvanized iron tubes medium grade with all fitting and fixed complete to walls, ceiling or laid in floor complete all as specified and directed.
S&F 500 ltr rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) triple layer wall construction hoisted and fixed in position complete all as specified and directed
S&F vitreous china wash basin, white flat back size 550x400mm , waste chain and plug and proclain stopper but including brackets and 01 Nos 15mm dia Fancy type CP Pillar cock, brass waste coupling 32mm dia, CP graiting 100mm dia and 01 No PVC connection 15mm dia 600mm long complete all as specified and directed..
S&F PVC connection 450 mm long, 15mm size with PTMT nuts complete all as specified.
S&F china ware urinal bowl flat back of size 465x355x265mm fixed with plug and waste pipe of suitable length complete all as specified and directed.
S&F10 ltr capacity PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as specified and directed.
S&F Orrisa pattern WC in ground floor vitreous china white of size 580mmx440mm including provision of lime concrete bedding iand connecting flush pipe etc complete all as specified and directed.
S&F 15mm bore stop valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F 20mm bore stop valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F 15mm bore bib tap cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F Grating CP 125mm dia fixed complete all as specfied and directed.
S&F brass chromium plated tubular towel rail 20mm dia(D) type 60cm long between flanges complete.
M&L for Glazed ceramic coloured tiles (300x200mm) x6-7mm thick on vertical surfaces as in skirting/dado, set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. .
M&L for Non skid jointless cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in neat cement slurry and pointed in white or coloured cement with pigment to match over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed. .
S&F for 110 mm PVC (SWR) Rain water pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F PVC (SWR) bends 110 mm dia
S & F PVC (SWR) vent cowl for 110mm dia PVC pipe complete all as specified and directed.
Excavation over areas not exceeding 1.50m depth for foundations etc and getting out in soft/loose soil complete all as specfied and directed.
Excavation over areas exceeding 1.50m but not exceeding 3.00m depth for foundations etc and getting out in soft/loose soil complete all as specfied and directed.
M&L for hand packing (any thickness) using broken bricks at back of walls over arches etc and raising (or lowering) to the required level complete all as specifed and directed.
M&L for 150mm bore cast iron pipes with spigot and socket ends centrifugally cast, class LA, in any length laid in trenches complete all as specified and directed.
S&F anodised aluminium snap grid work of size 605x605mm for false ceiling including hangers 6mm dia, GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
S&F 8mm thick calcium silicate board of silicous and calcerous material reinforced with cellulose fibre for fixing in snap grid work as per manufacturers instructions complete all as specified and directed.
M&L for 12mm thick perforated particle board/tiles for insulation and accoustic purpose, 600x600 mm in size, fixed with screws to timber frame work or with staples on snap grid complete all as specified and directed.
M&L for 2nd class hardwood plain fillets square, rectangular or triangular in section having cross sectional area exc 13 sqcm but not exc 25 sqcm, clean sawn, secured with nails or brads complete all as specified and directed.
Roughening surface of old concrete roof surfaces by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified and as directed
M&L for 50mm thick (Average thickness) PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding to RCC roofs to maintain slope finished fair and even complete all as specified and directed.
Material and labour for APP polymeric water proofing treatement to roof, at any height using membrane minimum 3 mm thick and weighting not less than 3.6 kg per sqm , black finish reinforced with non-woven polyster matt weighting not less than 150 gms per sqm with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 Ltr per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per sqm below APP with and including applying two coats of aluminium paint over surfaces complete all as specified and as directed . Notes:- (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee (on account of any defect raised/noticed during a period of ten years) and shall be released after 10 years of completion of work. However contractor may deposit the FDR of same amount in favour of GE. If contractor fails to rectify the defect pointed out during this period , the defect shall be got rectified at contractor's risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
Demolition of brick work built in cement mortar including all quoins,arches, pillers etc all as specified.
Demolition of cement concrete (unreinforced) as in ground floors and pavings not exc. 15cm thickness (below or above ground level) complete all as specified.
Taking down cement plaster or cement lime plaster on brick walls etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified.
Dismantling wall and PVC ceiling board of any description or thickness includiing cover fillets complete all as specified and directed.
Taking down chowkhats/frames with shutters (without taking off shutter from the frame) of any description, area not exc. 1.5 Sqm each (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same).
All as per Sl item No 77 above but exceeding 1.5 Sqm but not exceeding 4 Sqm each.
S & F steel window 1.25 mm thick box type (primer coated) ERW hollow P section of size 60mmx25mm single rebated comprises glazed shutter ERW sec 50mmx20mm and 1mm thick with two openable leaf consisting two Nos sash bars of T-section 20mmx3mm complete welded to frame with one verticle mulion of ERW box type T-section of size 60mmx25mm and 1.25mm thick including cutting holes and making good dismantled portion PCC (1:2:4) type B-1 (four Nos for each window) including following fittings welded to frame shutter: - (a) Hold fast, 150mm long of 12mmx3mm made to shape-04 Nos per window. (b) Handle of z section 20mmx25mm, 100mm long 01 Nos per leaf (c) MS tower bolt 150mm long-2 Nos per leaf (d) z section 20mmx25mm, 100mm long stopper - 01 No per leaf (f) MS pintal hinges of size 75mmx12mm- 2 Nos per leaf (g) Fabrication & fixing arrangement as per Drg No CEJZ/TD-06/07. Note: wire mesh and painting shall be measured & paid separately under respective items of BOQ.
Mild steel 20mm dia curtain rod powder coated with fixing side brackets, end cups, rings @ 10 Nos per running metre and fixed with PVC rawl plugs & steel screws complete all as specified.
M&L for prepartion of new primed steel surfaces and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for prepartion of new plastered surfaces of walls and applying two coats of exterior acrylic emulsion over a coat of primer in camouflage pattern using minimum 3 different approved colours/tint as approved by GE complete all as specified and directed.
S & F in repairs 2mm thick lead single shutter GI door with powder coating for X ray room (door size 1200x2100mm) as per existing pattren complete all as specified and directed by Engr-in-Incharge. The specifications are as under :- (i) Shutter thickness 45mm thick with 0.8mm thick GI finish powder coated. (ii) Frame profile 100x50mm with 1.2mm thick GI finish powder coated. (iii) Lead 2mm thick lead sheet embedded in the door leaf & door frame. (iv) Accessories - 1 No standard arm door closer, 2 Nos SS handle, 4 Nos SS ball bearing hinges, 1 No Mortise dead bolt with cylinder and 1 No drop seal. (v) Door shall be procured from the authorised dealers / manufacturers of X-ray room Door manufacturers or as approved by the GE in consultation with medical authorities.
M&L for 20-25 machine cut kota stone slab flooring over and including 20mm thick cement screed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
All as per Sl item No 84 above but kota stone as in skirting over and including 10mmrendering in CM 1:4 complete all as specified and directed.
M&L for 25mm thick cement concrete type B-0 using 12.5mm graded crushed stone aggregate as in sub base finished even and fair surfaces without using extra cement complete all a specified and directed..
S&F joist, channel, angle or tee sections Fe-410-W (Gde E-250 quality-B, fixed independently without connecting plates etc (cut to ordinary lengths ie within 20mm of the length indicated) complete all as specified and directed
S&F 8mm thick plate (plain or chequerred) Fe-410-W (Gde E-250 quality-A, square cut or notched (ordinary and counter sunk) forming holes without any attachement
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down carefully copper/aluminum point wiring of any type such as concealed/surface / batten/ casing and capping (light, fan, socket or power) complete including fitting such as switches, bell push, ceiling roses, pendants, lamp/ bracket holders, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc.
M&L for Point wiring conduit type in PVC conduit complete with 1.5 sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable (Phase and Neutral) PVC Conduit 20 mm bore having 2mm wall thickness with all conduit accessories for one light/fan point controlled by one switch including continuous 1.5 sq mm copper conductor, stranded FRLS (green colour, earh), PVC insulated unsheathed earth wire to common earth and connected to earth dolly to be terminated in and including suitable size Pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover make : Hylem /Anchor /Formica including machine screws and washers etc complete all as specified and directed.
All as per item No.91 here-in before butone ceilling / exhaust fan point controlled by one 5 Amps one way switch and regulator
All as per item No.91 here-in before butone 5 pin 6 Amps switch socket outlet point on independent board.
All as per item No.91 here-in before but One 5 pin 6 Amp switch socket outlet point on same board.
All as per item No.91 here-in before but 4.00 Sqmm copper wiring with 4.00Sqmm copper conductor as earth continuity for 15/16 Amps socket out let on independent board
S&F switch modular type single pole one way 6 Amps 1 module with box including suitable size of cover with frame etc.
S&F switch modular type single pole one way 16 Amps including suitable size of module cover with frame etc.
S&F Lamp Holder PVC polycorbnate type with back plate suitable for batten fittings all as specified and directed.
S&F Socket outlet 5 Pin 6 Amp modular type 2 module with box including suitable size of cover with frame.
S&F socket outlet 6/16 Amp 5 pin combined 2 module with box suitable size of cover with frame.
S&F of Ceiling rose, 3 phase/PVC/polycarbonate,isolated body.
S&F 10 watt retrofit pin type LED bulb all as specified and directed.
S&F in reparis IP-20 linear Retro LED T-8 tubular lamp with aluminium housing and PC diffuser complete with inbuilt driver 1x20 watt including new decorative box type prewired LED tubelight 4 feet long complete all as specified and directed.
S&F in repairs 10 watt LED mirror light 2 feet length, voltage range 100-300 v ac total light output 900-1200 lumens, color temperature pure white : 5500k-7000k general specifications, operating temperature 0-50 deg, dimensions 600mmx25mm
S&F in repairs LED luminaire 600x600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repairs Sheet metal enclosures factory made, (Double door) for DBs,single pole and neutral,240 volts, 8 way with 200Amps rated busbar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping,lagging testing and commissioning, complete all as specified.
S&F Sheet metal enclosures factory made, (Single door) for DBs,single pole and neutral, 240 volts, 2 way with 200Amps rated busbar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping,lagging testing and commissioning, complete all as specified.
S&F in repairs MCB single pole & Netural 40 Amps 230 Volts "C" series, 25KA, complete all as specified and directed.
S&Fin repairs MCB single pole 6 to 32 Amps 230 Volts "C" series, 10KA, complete all as specified and directed.
M&L in repairs for Earthing with galvanised steel earth plate electrode of size 60cmX60cmX6.3mm thick buried directly in ground (earth pit not less than 2.25m deep bellow the ground level) with top edge of the plate no less than 1.5m bellow normal ground level, connected to the galvanised earth lead by means of bolts, nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on complete including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm grade stone aggregate pit , funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI light grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:2:4) type B1 duly reinforced with 8mm dia TMT bar @ 150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh charcoal and common salt in alternate layer of 15cm thick complete as in replacement all as specified.
M&L Wiring for circuit/submain wiring in replacement and including PVC conduit along with earth wire with 2x6.00Sqmm+1x6.00Sqmm as earth wire of FRLS PVC insulated copper conductor single core cable including taking down old wiring, complete all as specified. Note :- 2 Run of sub main, one Run of Earth wire and PVC conduit shall be termed as ONE Unit.
Taking down XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area in any type and size complete all as specified and directed. Note : Earthwork will be measured and paid seperately.
M&L for cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 185 sqmm 3.5 core. complete all as specified and directed.
S&F 40mm bore GI tubing light grade as in cable protection pipe/earthing strip protection including all fittings complete all as directed
S&F 80mm bore GI tubing light grade as in cable protection pipe/earthing strip protection including all fittings complete all as directed
S&F copper strip 32 x 6 mm complete with porcealian saddles and base insulators (made out of porcelain / rubber) and fixing with screws for roof conductors and down conductors above ground complete as repairs all as specfied and directed..
M&L for Test point terminal block made of gun metal or phosphorus bronze of size 75 x 75 x25mm drilled and screwed with & including 3 Nos, 8mm dia 25mm long hexagonal head screw complete all as directed.
Supply, installation, testing and commissioning maintenance free tripod chemical earthing system consisting of 3 Nos of solid copper bonded earth rod of 10 feet length 17.2mm dia and 3 mtr long on outer surface having 250microns (minimum thickness) with exothermically welded joint of copper bus bar 150x50x5mm for long lasting and connecting each copper rod and the exothermically welded joint bus bar, both CPRI tested on at least 25KA fault current ensuring high current capacity of the system and earth rod should be certified by the Laboratories confirming to comply with UL 467- International standards grounding and bonding equipment and earth rod should be used with minimum 50 Kg earth enhancing compound that should be ROHS tested and have passed leaching sulphur, corrison, restivity test shall be less than 0.05 LHM mtr and international standard for earth enhancement compound by NABL accredited laboratory and each rod should be interconnected with 8mm dia copper clad steel conductor at the distance of 3 mtr to make a shape of triangle with 32x6mm copper strip, top of the bore finished with 40mm thick PCC in 1:2:4 type B-1, 75mm thick PCC 1:4:8, type D-2 and backfill/JAM compound shall be covered with advance polymer pit cover of 30x30cm size complete all as specified and directed. Note : 1. Cost of the items includes the scope of earth work, charcoal, salt, PCC, RCC, checmical compound and Pit cover of required size. 2. Testing of earth value shall be arranged by the contractor without any extra cost. 3. Valuie obtained of earh shall be below 1.00 ohm.
M & L for concealed Point wiring for light points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit not less than 19/20 mm dia with all fittings shunk in MS Pressed steel terminal boxessuitable depth and 1.6mm thick (duly painted with two coat of anticorrosive paint outsite and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified. Note:- Cost of cutting of chases wherever required in walls/ floors is deemed to be included in the unit rate of point wiring.
S&F LED light fitting, 20 W, 4 ft long 230V, Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired.and including connecting up with twin core twisted flexible copper conductor cable with suitable size as specified as in replacement complete all as specified.
Supply and fixing LED flat Bulkhead fitting 10 watt complete and fixing to wall / celing including fixing arrangement with clamps/ scrue/nuts/ bots /washers etc including LED light driver holder connecting up with 3 core flexible copper conductor of suitable size and connecting complete.
S&F Sheet metal enclosures factory made, (Doube door) for DBs, single pole and neutral, 240 volts, 4 way with 200Amps rated busbar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping,lagging testing and commissioning, complete all as specified.
M&L Wiring for circuit/submain wiring and including 25mm dia PVC conduit along with earth wire with 2x2.5Sqmm+1x2.5Sqmm as earth wire of FRLS PVC insulated copper conductor single core cable drawn through conduit fixed on walls/floors etc complete all as specified. Note :- 2 Run of sub main, one Run of Earth wire and PVC conduit shall be termed as ONE Unit.
Fixing only exhaust fans any sweep and size and connections complete all as specified and directed. Note : Exhaust fans will be issued free for fixing under Sch "B" .
S&F MCB isolator Single Pole 6 Amp 240 volts and connection complete all as specified and directed.
S&F MCB isolator Double Pole 20 Amp 240 volts and connection complete all as specified and directed.
Supply and fixing for Switch piano flush type single pole one way 6 amps 240 volts complete.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input voltage variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and as directed.
Supplying, installation and testing of Hi wall mounted split AC of capacity 2.0 TR of 5 Star rating with inverter technology, non CFC refrigerent with indoor and outdoor unit complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality including copper condenser and evaporator coil including making electrical connection to make it functional as per existing copper tube with insulation with and including MS readymade stand of suitable size for placing/fixing outdoor unit with necessary nuts, bolts and washers with and including making hole in wall/ roof for inserting insulation and pipe if required making good the disturbed surfaces complete all as specified and directed.
Supply and fixing of single pole and neutral, earth enlclosure with socket, MCB 20 A single phase and neutral , 230 V all as specified and directed.
Supply and fixing of triple pole and neutral, earth enlclosure with socket, MCB 63 A three single phase and neutral , 415 V all as specified and directed.
Supply and fixing of isolator 100 A four pole with fitting enclosure all as directed.
M&L for Point wiring conduit type with 4X 6 Sq mm sqmm PVC insulated unsheathed and multi stranded copper conductor PVC conduit 25 mm bore having 2 mm wall thickness with all conduit accessories for one AC point controlled by one switch including continuous 2X6 sqmm copper conductor, stranded (three phase and neutral and green as earth contunuity ) PVC insulated unsheathed earth wire to common earth and connected to earth dolly to be terminated in and including suitable size of metal enclosure etc as directed.
Supplying, installing, testing,connecting and commissioning air conditioner , electric driven, three phase of capacity 5.5 TR with accessories, ductable ceiling suspended type with R 410, BEE 5 star rated complete all as specified and directed. Note:- Duct with its connected items shall be measured and paid seperately.
Supplying, installation, testing and commissioning refrigerant liquid line (copper pipe) and insulated suction line piping with 19/13 mm thick closed cell elastomeric nitrile foam insulation suitable for ductable ceiling suspended type AC 5.5 TR, after taking down old material as existing at site complete all as specified and directed.
Supply and laying 2.5 Sq mm 6 core , PVC insulated copper conductor unsheathed flexible cables, 1100 volts conforming to IS: 694 in electrical cabling for ductable suspended type AC alongwith fixing arrangements all as existing at site complete all as specified and directed.
Supplying and laying 6 Sqmm single core FR-LSH, PVC Insulated copper conductor unsheathed flexible cables, 1100 Volts conforming to IS: 694 in electrical cabling for ductable suspended type AC alongwith fixing arrangements after taking down old material as existing at site complete all as specified and directed.
Supplying, installation, testing and commissioning of factory fabricated galvanized steel sheet (G.S.S.) square/rectangular ducting for supply/return air,fabricated from galvanized steel sheet, having zinc coating of 160 gm per sqm total on both sides with neoprene rubber gaskets, elbows, splitters, vanes, upports to installed /hanging the duct with suitable size of stainless steel hole fastner etc as per IS: 655/1963 with required scaffolding work to install the ducts at site of sheet thickness 24 SWG as per drawing as reqd at site complete all as specified and directed. NOTES:- (i) Duct/Fan coil unit to rest on angle bracket/channel supported on nearest wall/ mounted from ceiling and shall be measured and paid separetely.(ii). Position of diffusers, grill may change as per site requirement and shall be measured and paid separetely. (iii) False ceiling Grid will be adjusted a per Grill size. (iv) Return Air Grill will be fixed 15" height above the floor level on the wall. (iv) The drg for layout and size of duct shall be submitted by contractor and shall be approved by GE before fabrication.
Supplying and fixing duct thermal insulation with 9mm wall thickness black nitrile rubber, class 1 complete all as specified and directed.
Supplying and fixing acoustic lining for duct 25mm thick fiberglass wool with density not less than 30 Kg/Cum complete all as specified and directed.
Supplying and fixing aluminium extruded powder coated return air grill / diffuser, superior finish excellent strength, rust proof complete all as specified and directed.
Supplying and fixing canvas connection/notch lock of size 75mmx 75mmx 75mm made of double folded fabric/metal connector, notched for easy fabrication with metal edges dimpled for permanent grip to eliminates vibration noise in the air system complete all as specified and directed.
Material and labour for stand made of Mild steel flat/angle/ channel or any other section conforming to Fe-290 Gde E-165 epoxy coated including all necessary welding, drilling, bolting or riverting for fixing outdoor unit of ductable type AC complete all as specified and directed.
Supplying and fixing PVC drain pipe 32mm dia alongwith fittings such as T socket bend etc for draining out waste water with fixing arrangements complete all as specified and directed. Note For Sl No 136 to 144:- (i) The payment of AC with duct shall be allowed only after site inspection by the rep of Accepting officer. (ii) Installation/fabrication of ACs and accessories shall be carried out all as per manufacturer instruction.
Supply and fixing of Electric motor siren horizontal mounted , double fittment, aluminium casted, copper wound, ideal audible range 5.0 KM (Diametrical), 2880 RPM, 3 HP motor , 3 phase, 415 V, 50 Hz with all connected accessories all as specified and directed. Note:(i) Grouting of siren and dismantling and making PCC for grouting shall be included in quoted rate. (ii) Testing should be made by contractor. (iii) Providing of protection cover with angle iron and MS jallit at site of Electric siren and fix it on top for protection from rain water and direct sun light complete all as directed by Engr-in-Charge. Rate for the same shall be included in unit quoted rate.
Supply and fixing of isolator TPN 40 A , 415 V with suitable box type fitting enclosure all as specified and as directed.
M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 V grade cross sectional area 10 sq mm 4 core all as specified and directed.
JINDAL AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .