Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹14.6 L
EMD Value
₹29,255
Closing Date
26 Sept 2023, 2:00 pmClosed
SE,MMC,HTPS
SE,MMC,HTPS,KASIMPUR,ALIGARH-202127
Procurement of electrical items ,coupling and rubber items for HTPS
2023_RVUNL_822487_1
ET-58/MMC/EPD/CTPS/HTPS/2023
Open Tender
Electrical Work/ Equipment
Fixed-rate
45 days
HTPS, KASIMPUR
AS PER TENDER DOCUMENT
2 documents required · 2 mandatory
₹1,652
SAO,EPAD,UPRVUNL,KASIMPUR
₹29,255
17 Nov 2023
21 Jul 2023
27 Sept 2023
21 Jul 2023
26 Sept 2023
21 Jul 2023
21 Jul 2023 - 26 Sept 2023
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 40A, CSSD40D3 (Load Break Switch) (Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 32A, CSSDF32D3 TP SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 63A, CSSDF63D3 TP SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 63A, CSSDF63D3N TPN SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 125A, CSSDF125D3 TP SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 250A, CSSDF250D3 TP SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 315A, CSSDF315D3 TP SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 400A, CSSDF400D3 TP SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 630A, CSSDF630D3N TPN SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 63A, FN63 TPN SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 100A, FN100 TPN SFU(Conforming: IS/IEC 60947-3 IS 13947-4-1 / IEC 60947-4-1)
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 63A, 3KL8151-3HA00, TP SFU
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 125A, 3KL8221-3HA00, TP SFU
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 250A, 3KL8321-3UA00, TP SFU
Complete Switch Disconnector Fuse Unit , Isolators , Electric Switch Disconnector (Load Break Switch LBS) , without Fuse Links, Open Execution, (415 V AC, 50Hz) Suitable for DIN HRC Fuse Links, with Door interlock, Door Defeat Interlock and Padlocking in ON Position, with 1NO+1NC Auxilliary Contact of Rating 315A, 3KL8331-3UA00, TP SFU
Complete Power Contactor 9.1 A, CE15B TP CV 110AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 16 A, LC1-D17 TP CV 110 V AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 32A, LC1-D323 TP CV 110 V AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 50A, CE15H TP CV 110AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 63A, LC1-D503-A60 TP CV 220AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 63A, 3TF47 TP CV(CV) 220AC, 50Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 115A, LC1FDP115A TP CV 110 V AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 250A, 3TF54 02-0AF0 CV 110 V AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 265A, LC1FDP265A TP CV 110 V AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 400A, LC1FDP3302A TP CV 110 V AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete Power Contactor 630A, LC1FDP630A TP CV 110 V AC, 50 Hz Rated Voltage-415VAC, 50 Hz, Ui:1kV, U air break type, Class III category AC3, with 2NO+2NC auxiliary contacts rated 10 A at operating voltage ( Conforming to IS: 2959 and BS: 775)
Complete 630A, 415VAC, 50Hz, FGC630 Manual On Load Changeover Switch, with Door interlock, Door Defeat Interlock and Padlocking, Ui:1kVAC, 50Hz, IEC:60947-3, IS:13947-3 with 2NO+2NC auxiliary contacts.
Bimetallic Thermal Over Load Relay TR2D09305 Range 0.63-1A with Base and necessary assembly accessories
Auxiliary Contact TCA3DN22 (2NO+2NC) 10A, 110 VAC
Auxiliary Contact TCA3DN40 (4NO) 10A, 110VAC
Auxiliary Contact 3TF30 10-0AF0(1NO)
Auxiliary Contact 3TH30 40-0AF0(4NO)
Auxiliary Contact 3TH30 22-0AF0(2NO+2NC)
Auxiliary Contact 3TH30 31-0AF0(3NO+1NC)
Auxiliary Contact 3TX4 010-2A(1NO CONTACT)
ADD-ON Block LA1-D22 (2NO+2NC)
Control Transformer of rating 500VA, 415/230 (±10%)V AC, Insu Class-B, Type-AN, 1 Ph,
Control Transformer of rating 250VA, 415/230 (±10%)V AC, Insu Class-B, Type-AN, 1 Ph,
Control Transformer of rating 100VA, 415/18/24 (±10%)V AC, Insu Class-B, Type-AN, 1 Ph,
Pin Insulator 105KVA for HVR T/F
SILICA GEL for HVR T/F
SUPPORT INSULATOR for HVR T/F
EPOXY RESIN BASED INSULATOR
ESP CONNECTOR 35MM2 (feed through terminals)
ESP CONNECTOR 16MM2 (feed through terminals)
ESP HVR OTI oil temp indicator
Bushing Insulator 105KVA for HVR TF
Breather for HVR TF (silica gel pot)
Spider coupling rubber for Rathi make coupling of motor and pump for DC SOP RRS 150/100
Spider coupling for motor & pump for DC SOP RRS150/100, Make-Rathi
Spider coupling for motor & pump for AC SOP RRS110/100, Make-Rathi
spider coupling rubber for Rathi make coupling of motor and pump for DC SOP RRS 110/100
Non-Sparking(Sparkless) Mechanical Adjustable Torque Click Wrench Torque Range: 20-200Nm.
Bihar Ceramics
BE LIGHTNING SYSTEM PVT LTD
Bihar Ceramics
BE LIGHTNING SYSTEM PVT LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .