| 1 | 1₹10.5 LAccepted-AOC MAGADH COLONY ROAD NO 6 SHERGHATI ROAD GAYA BIHAR 823001 | GAYA | GAYA | BIHAR | 823001 | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹11.5 L+₹44,000 (3.98%)Rejected-Finance HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹14.4 L+₹3.4 L (30.6%)Rejected-Finance EAST DIGHI TANK OLD LIC COMPOUND GAYA BIHAR 823001 | GAYA | BIHAR | 823001 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹15.7 L+₹4.6 L (41.8%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹17.1 L+₹6.1 L (55.1%)Rejected-Finance WZ 484 M S BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Dec 2022, 6:00 pmClosed
GE GAYA
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar, PIN-823005
Repair/maint of security/street light, perimeter lights, timer panel and connected items at Zone A at Mil Stn Gaya
2022_MES_554125_2
8049/GE/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GAYA
₹40,000
Yes
31 Jan 2023
28 Nov 2022
12 Dec 2022
28 Nov 2022
10 Dec 2022
1 Dec 2022
Amount
Checking and maintenance of street light, perimeter light and high mast light including accessories, LED lights fitting on wall or pole or high mast and of any other locations to find out defects including dismantling of defective parts or taking down the fitting if, necessary, cleaning the bowl/ perflex cover and making the fitting in 100% serviceable condition including rectification of fault of over head lines and under ground cables if, any complete all as specified and directed by Engineer-in-Charge. Note: (i) The Contractor shall deploy minimum 01 Elect and 01 Helper except sunday & holidays for the purpose from 0900 hrs to 1700 Hrs daily. (ii) All T&P/Safety items shall be provided by the contractor at his own cost. (iii) The Contractor shall rectify the complaint within 24 Hours otherwise penal charge will be imposed at the rate of A 200/ per complaint/ per hour. (iv) Quoted rates shall include arrangement of bucket crane of high height or any other means required to rectify the compliants at the height of 11/18 metre or above. Safety of the tradesmen employed shall be the resposibility of the contractor. (v) Defective parts such as LED driver, service wire, cable joints shall be measured and paid under relevent item separately. However cost of replacement of minor parts such as nut, bolt, washer etc shall be inclusive in quoted rates.
Dismantling and setting aside for reuse existing old steel tubular poles with insulators, embeded in PCC foundation / coping / plinth including demolition of foundation cement concrete of any description, below or above ground level, complete all as specified and as directed by Engineer-in-Charge.
Taking down existing old unserviceable underground LT cable upto size 35 Sqmm, 3.5 / 2 core keeping aside for reuse/removal from trenches/wall/pole complete all as specified and directed by Engineer-in-Charge.
M & L for demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
Refixing of old serviceable steel tubular swaged poles any type/size/length obtained from item Sr. No: 2 here-in- before after dismantling and erecting in new location as directed by Engineer-in-Charge including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and painting of 30 cm wide black and white strips upto 1.5 mtr from bottom of the erected pole including marking of pole number complete all as specified and directed. Note: (A) Rate quoted shall be deemed to be inclusive of the following : (i) Any repair / welding / fabrication work on the old poles. (ii) Any rusted surface on the old pole shall be treated with red oxide primer prior to application of aluminium paint. (B) Necessary excavation, earth work and PCC shall be measured and paid for separately.
Relaying of cable upto 35 Sqmm 3.5/2 Core after rectification of defects in the same in trench/wall/pole or at any other location complete all as specified and directed.
M & L for heat shrinkable straight through joint outdoor type for XLPE insulated armoured cable of size 10 Sqmm to 35 Sqmm 3.5 core and testing after jointing complete all as specified and directed. Make: Raychem/Denson/M-Seal
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core. Make: Havells/ Finolex / KEI / Polycab
All as per item Srl No. 8 above but of size 10 Sqmm x 4 Core.
All as per item Srl No. 8 above but of size 25 Sqmm x 4 Core.
Cuttings of tree branches along the LT electric over head lines / security light at least upto 2.5 mtr from electric lights and disposal of unserviceable material to a distance n exc. 50 m and clearing site complete all as directed.
S & F in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including necessary electrical connections from junction box to fitting terminal with 3 core 2.5 sq mm cable complete all as specified and directed. Make: Cat Part No. LSTP-70-CDL-M of crompton / SLE UL 72W IP66 (LXN) of Surya of its equivalent in Philips
S & F in replacement LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including necessary electrical connections from junction box to fitting terminal with 3 core 2.5 sq mm cable complete all as specified and directed. Make: Cat Part No. LSTP-100-CDL-M of crompton / SLE UL 100W IP66 (LXN) of Surya of its equivalent in Philips
S & F in replacement LED street light fitting 150 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including necessary electrical connections from junction box to fitting terminal with 3 core 2.5 sq mm cable complete all as specified and directed. Make: Cat Part No. LSTP-150-CDL-M of crompton / SLE UL 150W IP66 (LXN) of Surya of its equivalent in Philips
S & F in replacement LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete including necessary electrical connections from junction box to fitting terminal with 3 core 2.5 sq mm cable for fixing on high mast poles complete all as specified and directed. Make: Cat Part No. LFLN-200-CDL/60-M of crompton / SLE FL 200W IP66 LUMOS II of Surya or its equivalent in Philips
M & L for steel tubing galvanised iron, light grade 50 mm bore for cable protection along the pole, under road/depth or under drains complete including 30x5mm FI clamps made to shape incl nuts, bolts & washers complete and taking down old unserviceable pipe all as specified.all as specified and directed by Engr-in-charge.
S & F PVC Junction box of size 340mm x 285mmm x 120mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and outgoing cable/wire complete comprising of aluminium bus bar for 3 phases & neutral, insulated with insulators, including colour coding and 01 Nos MCB 06 Amps complete all as specified and directed. Make: Sintex Model : GSMB-3428/ National Model No: NJB3020 / Mahindra Composits
Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified.
Returning filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified.
Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified
M & L for laying of HDPE double wall corrugated pipes in trench for UG cable protection conforming to IS-14930 Part-II with IP-67 having outer dia 40 mm and inner dia of 32 mm including necessary fittings such as couplers, bends etc complete all as specified and directed.
Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.
Supply and laying for brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cales abutting each other complete all as specified and directed.
M & L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth without using extra cement complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed.
M & L for passing through poles from junction box to street light connection,1100 volts grade heavy duty cable with weather proof, PVC insulated copper conductor served with an inner sheathing PVC tape and overall PVC sheathed 1.5 sq mm 3 core complete all as specified & directed. Make: Polycab/Havells/Finolex
S & F street light bracket fabricated from 40 mm dia light grade GI pipe 1.2 m long, bent to shape fixed on pole / building including 40x6mm flat iron MS clamps with nuts and bolts etc, duly painted with two coats of silver paint over a coat of red oxide primer including taking down old brackets from existing position complete all as specified and directed..
M & L for making two Nos of holes of required dia at bottom and top of existing steel tubular pole by necessary drilling/welding for passing of service cable including passing/reconnecting of existing street light fitting to junction box complete all as specified and directed.
S & F in replacement contactor 65 Amps 3 Pole with AC coil type CN 565 T11 cat part No IHPHA065300M of Make : Havells or its equivalent
S & Fin replacement street light timer switch 1-16A, 230 Volts all etc complete as specified and directed by Engr-in-charge. Make : Selec/Havells or its equivalent
S & F in replacement LED driver suitable for LED street light/flood light fitting as per site requirement of capacity upto 120 watt, complete all as specified and directed. Make : Bajaj/Havells/Crompton/ C&S/HPL
S & F in replacement LED driver suitable for LED street light/flood light fitting as per site requirement of capacity 150 to 200 watt watt, complete all as specified and directed. Make : Bajaj/Havells/Crompton/ C&S/HPL
S & F in replacement broken door hinges with new MS hinges of length 2” screwed/welded with door and made the door operational condition of street light timer panel any type and capacity all as directed by Engineer-in-Charge.
M & L for rubbing rusted surface of street light timer panel, cleaning the inner and outer surface of panel box and applying two coats of synthetic enamel spray paint over a coat of red oxide zinc chrome primer including painting of MS angle frame complete all as specified and directed.
M/S CHAUHAN CONSTRUCTION
M/s Vinay Kumar
M/S PANCHAM RAI SONS
MS HARI MOHAN GUPTA
BHARADWAJ BROTHERS
M/S K D TURAIHA
M/S ABHAY KUMAR AND BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .