| 1 | 1₹56.2 LAccepted-AOC C 89 CECC VILL POST PATHOLI AGRA UP | AGRA | AGRA | UTTAR PRADESH | 283105 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹57.9 L+₹580.50 (0.01%)Rejected-Finance D 89 SHASTRI NAGAR MEERUT 250004 | MEERUT | UTTAR PRADESH | 250004 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹58.0 L+₹6,232 (0.11%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹65.0 L+₹7.1 L (12.2%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹65.6 L+₹7.7 L (13.2%)Rejected-Finance 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | 5 | Rejected-Finance Not being lowest |
Tender Value
₹83 L
EMD Value
₹1.5 L
Closing Date
28 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE AGRA
112 TAJ ROAD AGRA CANTT
SPL REPAIR TO OSS BLDG NO.P-21 AT 509 ABW UNDER GE (EAST) AGRA
2023_MES_619197_2
84286/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
MES contractors enlisted in Class C category a(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE EAST AGRA
₹1.5 L
Yes
21 Dec 2023
7 Oct 2023
4 Nov 2023
7 Oct 2023
28 Oct 2023
21 Oct 2023
7 Oct 2023 - 14 Oct 2023
Amount
Dismantling asbestos cement (corrugated, semicorrugated sheet/ North light curve, Ridge etc.) sheets in roof coverings complete all as specified and directed.
S&F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet (green colour) 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of Pre- painted galvalume aluminum zinc coating GI based plain steel sheet (green colour) 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/ roof covering/cladding to wall/north light curve, fixed with self tapping screws complete all as specified and directed.
S&F Plain, galvanised, mild steel sheeting, 1.00 mm thick in, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with self tapping screws complete all as specified and directed.
Dismantling of wrought iron of mild steel work of any description not otherwise poivided complete all as specified and diredted.
S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, wind tie,channel or flat sections) including distance pieces, cleats etc Fe 410 -W (GdeE- 250) quality A complete all as specified and directed.
Preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Preparation of old steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint at any hight complete all as specified and directed.
Demolition of wall and ceiling board or insulation board /slabs/blanket any thickness including cover fillets complete all as specified and diredted.
S&F in repair 605x605mm size snap grid of powder coated galvanized iron of angle of size 23mm x 23mm of 30 gauge (Perimeter), T section of size 23mm x35mm main and 23mm x 27 mm (intermediate) of 30 gauge suitable for false ceiling including GI wire 4 mm thick @ 1200 mm centre to ceter both ways for hanging arragement complete all as specified and directed
M&L for 4mm thick non asbestos fibre cement building board designer as in ceiling of size 600 x 600mm fixed to GI snap grid frame work complete all as specified & directed.
M&L for providing, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) for embedding hold fasts/coping on roof kerb etc including necessary form work etc.complete all as specified and directed.
Taking down cement or cement lime plaster of any discription on bricks or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and diredted.
M&L for 15mm thick plastering in CM 1:6 on brick surfaces of walls & finishing the surface even & smooth complete all as specified and directed.
M&L for 15mm thick plastering in CM 1:4 on brick surfaces of walls & finishing the surface even & smooth complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillar, wall etc complete all as specified and diredted.
Preparing old plastered or unplastered surfaces of walls by brooming down or by steel wire brushing scraping down smoke soot, moulds moss and efflorescent salts and applying two coats of oil bound distamper over a coat of average 2mm thick Birla putty, complete all as specified and directed.
Material and Labour for preparation of old plastered or unplastered surfaces of wall including cornices, pilaster etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply one coat of white wash complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors / dados, etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over & including 15mm thick screed bed in CM 1:6.complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over & including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed.
M&L for Coloured Glazed ceramic tiles of size 450X 300X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over & including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick incl and over cement screed bed 20 mm thick in 1:6 cement and sand mortrar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
S&F in repair PVC (SWR) pipes single socketed 200 mm bore, incl bend, shose, Tee, Y, as required, etc in any length with rubber ring joints fixed to walls with MS clamp complete all as specified and directed.
S&F in repair MS Sheet (1.25 mm thick) angle (internal or external ) or nozzle pieces 200 mm dia(outlets) complete all as specified and directed.
Dismentling wall lining/paneling board or insulation board /slabs/blanket any thickness including cover fillets complete all as specified and diredted.
M&L for lnsulated PVC Solid PVC Wall Lining consisting of 5mm thick but wood grain printed PVC sheet used instead of plain colour sheet fixing with solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and diredted.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and diredted.
M&L Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 for side wall for inserting roof sheet,complete all as specified and diredted.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and directed.
M&L for Point wiring complete for One light /Fan /Exhaust Fan/ Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm dia in roof / floor slab and ceiling, MS sunken boxes incl modular duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
All as per item No 35 here in before but for one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches
All as per item No 35 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board
All as per item No 35 here in before but for One Bell/Buzzer point controlled by One Push button on an independent board
All as per item No 39 here in before but with cable size FRLSH cable 4 Sq mm for one 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm all as specified and directed
Supply and fixing switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fixing Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing socket 5 amps 3 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed.
Supply and fixing socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
Supply and fixing stepped type electronic fan regulator socket type ISI marked on the existing phenolic laminated sheet etc. as required, complete all as specified and directed
Supply and fix ceiling rose , PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals, complete all as specified and directed.
Supply and fixing in repair Lamp holder/angle holder insulated body with black/white plate for batten fittings incl 7 watt LED Bulb complete all as specified and directed.
Supply and fixing Call Bell, AC, 230 volts, single pole, complete all as specified and directed.
Supply and fixing in repair LED luminaire 595 mm x 595 mm, 36 watt, 220 V AC, 6500 K surface/ recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
Supply and fixing ceiling fan (copper winding), 1200mm sweep, minimum BLDC Brush Less Direct Current Energy saving ceiling fan of size 1200 mm sweep, 230 Volts, 50 Hz power consumption is less than 28 watt, 5 star rated noiseless motor operation, inverter stabilization technology, 370 RPM, 210 cum/min complete with standard accessories i.e (three blade, 02 Nos canopy, down rod of length 1.5 mtr to 2.0 mtr long, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound, including electrically connecting from ceiling rose to fan connector with 0.75 sqmm stranded copper conductor three core flexible cable with suitable size flexible PVC conduit complete all as specified and directed.
Dismantling, taking down existing ceiling fan and re-fixing & connecting up including provision of cable from ceiling rose or connector to fan including renewal of down rod, hanging clamp, PVC canopy, nut, bolts and suitable size flexible PVC conduit complete all as specified and directed.
Supply and fixing in renewal LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 40 mm dia GI light grade pipe, 1.20 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps of size 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and fixing Exhaust Fan high quality engineering plastic, resistant to colour change with anti- station properties (ventil air) 200 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, grouting of nuts, bolts, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side (outer surface of wall) and cutting with and including PVC insulated three core 0.75 sqmm copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed.
Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp complete all as specified and directed.
Supply and fixing in repair three phase and neutral enclosure with a 3 pin and earth plug and socket complete with one MCB TPN of capacity 40-63 Amp complete all as specified and directed.
Supply & fixing in repair/renewal of sheet metal enclosure Vertical TPN DB 4 Way double door As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 earthbar and Cable ties for Cable manage-ment, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for easy of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, With provision for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 12 way ISI marked, complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing in repair MCB DB single pole with neutral sheet metal enclosure double door type, 240 Volts AC, with 200 amp rat-ed bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fab-ricated, powder coated complete with out MCB and with enclo-sure blank plates for unused way suitable for 4 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing MCCB 4 pole, 160 Amps, 50 Hz, Icu=16 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in renewal of LED flood light 100W with IP 66 protection comprises of a pressure dia cast aluminium housing, heat resistance toughened glass/ polycarbonate, LED lenses, surge protector, BIS electronic driver, etc and all accessories prewired including connecting up with PVC insulated copper conductor cable 4 sqmm , single core as required for connections etc. complete all as specified and directed.
M&L for Submain wiring with two single core FRLSH 4 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth including dismantling of old unsv sub-main wiring and connection to earth dolly complete all as specified and directed. Note:- Two single core FRLSH 4 sqmm copper conductor, one run PVC conduit and one run of FRLSH 4 sqmm earth wire shall be considered & measured as one unit.
M&L for Submain wiring with two single core FRLSH 6 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth including dismantling of old unsv sub-main wiring and connection to earth dolly complete all as specified Note:- Two single core FRLSH 6 sqmm copper conductor, one run PVC conduit and one run of FRLSH 6 sqmm earth wire shall be considered & measured as one unit.
M&L for Submain wiring with two single core FRLSH 10 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 10 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and including dismantling of old unsv sub-main wiring connection to earth dolly complete all as specified Note:- Two single core FRLSH 10 sqmm copper conductor, one run PVC conduit and one run of FRLSH 10 sqmm earth wire shall be considered & measured as one unit.
M&L for Submain wiring with four single core FRLSH 10 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 10 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and including dismantling of old unsv sub-main wiring connection to earth dolly complete all as specified. Note:- Four single core FRLSH 10 sqmm copper conductor, one run PVC conduit and one run of FRLSH 10 sqmm earth wire shall be considered & measured as one unit.
M&L for earthing complete with galvanized earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground vertically (to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES :- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor complete all as specified and directed.
Supply and laying in renewal XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 Core in trench/floor/on pole/wall complete all as specified and directed.
Supply and laying in renewal XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 Core in trench/floor/on pole/wall complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm thick complete all as specified and directed.
Removing exeavated material n. exc 50 m and depositing where directed at a level n. exc 1.5 m above starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 40 mm to 90 mm bore HDPE pipe of any description below/under existing road surfaces / floors at a level not less than 0.60 metre etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt.
Supply and lay HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 50 mm including all fittings complete all as specified and directed.
Supply and fix in repair ON LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 400 Amps, including fixing on walls, complete all as specified and directed.
Supply, fixing, installation , Testing and Commissiong Outdoor type cubicle Bus Bar aluminium Chamber 400 Amps for three phases, 4 wire IP-65 protection rupturing capacity at 415 volts , factory made having powder coating including necessary angle iron and PCC foundation of size as directed and earth work, complete all as specified and directed
mohanlal gupta
M/S SUNNY ASSOCIATE
Sree Ram Enterprises
M/s J S & SONS
Gupta Automobiles
Attar Singh and Sons
M/s M S Sharma and Co.
B S ENTERPRISES
Sethi Brothers
deva engineers
CREATIVE CONSTRUCTION
M/s Shrangi Rishi Construction
M/S OMKAR SINGH YADAV
Krishna Constructions
Asha Construction
R.C. Magla and Co.
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .