Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹3.9 L
Closing Date
29 Oct 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tata Power Delhi Distribution Limited
HVAC Works at CENNET, TPDDL
200001727
TPDDL/ENGG/ENQ/200001727/24-25
Delhi
1. Bidder must have completed three work orders for similar works**(related to schedule of quantities)for a total of at least Rs 32.00 Lakhs each or two orders for similar works for a total value of at least Rs 40 Lakhs each, or a single order for Rs 64.00 Lakhs in last 3(three)years, ending on 31st March of the previous financial year(order copies to be provided) 2. The bidder must have average annual turnover of Rs 80.00 lakhs for last 3(three) years, ending on 31st March of the previous financial year(financial statements to be provided) 3. Bidder must have performance certificates of completed jobs from companies/ departments for point no 2 **Similar works signify related to schedule of quantities and as per SCC/SLA
₹5,000
₹3.9 L
8 Oct 2024
8 Oct 2024
29 Oct 2024
COPPER REFRIGERANT PIPING- Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications. Piping shall be of following sizes -- Pipe Size (OD) - 41.30 mm & Thickness of CSE Insulation - 19 mm.
COPPER REFRIGERANT PIPING- Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications. Piping shall be of following sizes -- Pipe Size (OD) - 28.60 mm & Thickness of CSE Insulation - 19 mm.
COPPER REFRIGERANT PIPING- Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications. Piping shall be of following sizes -- Pipe Size (OD) - 22.20 mm & Thickness of CSE Insulation - 19 mm.
COPPER REFRIGERANT PIPING- Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications. Piping shall be of following sizes -- Pipe Size (OD) - 19.10 mm & Thickness of CSE Insulation - 16 mm.
COPPER REFRIGERANT PIPING- Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications. Piping shall be of following sizes -- Pipe Size (OD) - 15.90 mm & Thickness of CSE Insulation - 16 mm.
COPPER REFRIGERANT PIPING- Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications. Piping shall be of following sizes -- Pipe Size (OD) - 12.70 mm & Thickness of CSE Insulation - 16 mm.
COPPER REFRIGERANT PIPING- Supply, Installation, Testing & Commissioning of high pressure copper refrigerant piping including R410a refrigerant of suitable size as required and duly insulated with19mm/13mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form. External Refrigerant piping shall be laid on GI covered cable trays. Piping inside occupied spaces shall be supported using MS hangers duly painted with black enamel paint. Entire refrigerant piping work shall be carried out in accordance with the specifications. Piping shall be of following sizes -- Pipe Size (OD) - 9.50 mm & Thickness of CSE Insulation - 16 mm.
CONDENSATE DRAIN PIPING -UPVC -Supply, Installation, Testing and Commissioning of UPVC pipes cut to required lengths and installed for condensate drain. Quoted price shall be inclusive of supply and fixing in position the necessary fittings like elbows, tees reducers etc. and supporting arrangement in accordance with the approved shop drawings and specifications. Pipes shall be insulated with 9mm thick closed cell elastomeric insulation with class 'O' fire retardant properties in tubing form . Pipes shall be of following sizes : 25 mm dia.
SITE FABRICATED DUCTING work -- Supply, Fabrication, Installation and Testing of sheet metal ducts complete with vanes, splitter dampers, hanging arrangement including check nuts in accordance with the approved shop drawings and specifications.- b. 0.8 mm (22 gauge) GSS
INSULATION & ACOUSTIC LINING OF DUCTS -Supply and Application of internal acoustic lining of supply air ducting using open cell nitrile rubber insulation with density within 140-180 Kg/m3 as per the approved shop drawings and specifications. Insulation material shall be bonded with the ducts using metal screw and washers to facilitate grip to the GI sheet. 10 mm thick lining
THERMAL INSULATION OF DUCTS-- Supply and Installation of external thermal insulation of supply /return air ducting using closed cell elastomeric nitrile rubber insulation with class 'O' fire retardant properties as per the specifications and drawing- 13 mm thick insulation
CONTROL & communication cables - Supply, laying, affecting connections and Testing of the following sizes of control cum transmission wiring to be laid in MS conduits between indoor units and outdoor units 2C x1.5 Sqmm copper wiring.
CONTROL & communication cables - Supply, laying, affecting connections and Testing of the following sizes of control cum transmission wiring to be laid in MS conduits between indoor units and their wired remotes 2C x1.5 Sqmm copper wiring.
L T CABILING work --Supply, laying, affecting connections and Testing of the following sizes of 1.1 KV armoured PVC insulated copper conductor cables. Cables shall be inclusive of all clamps, saddles, screws, cable identification tags, cable terminal joints including terminal lugs, insulating tapes, affecting terminal connections to the equipment as per the specifications and as required. a) 4 C x 10 Sqmm cable (Copper)
L T CABILING work --Supply, laying, affecting connections and Testing of the following sizes of 1.1 KV armoured PVC insulated ALUMINIUM ARMOURED conductor cables. Cables shall be inclusive of all clamps, saddles, screws, cable identification tags, cable terminal joints including terminal lugs, insulating tapes, affecting terminal connections to the equipment as per the specifications and as required. a) 4 C x 240 Sqmm cable (Aluminium )
EARTHING- Providing & fixing in position the following bare GI tape/ Cu wire including providing all fixing accessories & effecting proper connections. of size 8 SWG GI wire .
Cable Trays - Supply and fixing necessary GI perforated 2mm thick cable tray for laying of ODU Copper piping /cables:at terrace floor of size 65 x 300 x 65 mm
DUCT CLEANING-- Robotic air conditioning Duct Celaning system for galvanised sheet metal ducts including elbows ,turning vanes ,neoprene /PVC fire retardant gaskets and etc. Charge in floor area
Dismantling of and removal existing CHW based double skin air handling units (AHUs) with valves each comprising of following as per the specifications : The scrap shall be handed over to the TPDDL in the same premises. 1500cfm to 3000cfm ceiling mounted type
Dismantling of and removal existing CHW based double skin air handling units (AHUs) with valves each comprising of following as per the specifications : The scrap shall be handed over to the TPDDL in the same premises. 4500 CFM to 9000 cfm Floor mounted type
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth. Lead upto 50 m and lift upto 1.5 m;disposed earth to be leveled and neatly dressed for all kinds of soil.
Filling available excavated earth (excluding rock) trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming watering, lead up to 50 m and lift upto 1.5 m
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level: 1:4:8 (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size )
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centring and shuttering including struttting ,propping etc.and removal of form for : Foundations , footings , bases of columns etc for mass concrete
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Cold twisted bars / Thermo-Mechanically Treated bars.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to C & D Waste Recycling Plant for all leads including all lifts involved. (BA has to deposite the recycling processing charges at prevailing rates of Rs. 205.00 per MT at C<(>&<)>D plant and submit the receipt to concerned EIC)
COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT ( CAMC ) Charges on annual basis ( AS PER ATTACHED SLA ) for 5 years Comprehensive AMC for VRF based HVAC ---------- Make at TPDDL CENNET building PITAMURA , post successful commissioning. CAMC shall be at the option of Tata Power DDL (TPDDL) and shall only be applicable after Defect Liability Period (i.e. one year after commissioning and taking over by TPDDL) .
For Ist Year
For 2nd Year
For 3rd Year
For 4th Year
For 5th Year
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tender 200001727_Annexure I Schedule of Item.pdf
Tender Document • 0.55 MB
Tender 200001727_Annexure I Schedule of Item.xlsx
Tender Document • 0.04 MB
Tender 200001727_Annexure- SSI Questionnaire -.pdf
Tender Document • 0.21 MB
Tender 200001727_Approved makes.pdf
Tender Document • 0.19 MB
Tender 200001727_CENNET ref 2ND FLOOR.pdf
Tender Document • 1.76 MB
Tender 200001727_CENNET ref FIRST FLOOR (2).pdf
Tender Document • 1.35 MB
Tender 200001727_CENNET ref GROUND FLOOR (1).pdf
Tender Document • 1.36 MB
Tender 200001727_Safety Bid.pdf
Tender Document • 0.31 MB
Tender 200001727_TPDDL-ENGG-ENQ-200001727-FY 24-25.pdf
Tender Document • 0.75 MB
Pre Bid Response_1727I.pdf
Corrigendum • 0.08 MB
Pre Bid Response_1727I.pdf
Corrigendum • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .