| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹7.8 Cr Quoted ₹7.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹9.2 Cr+₹1.3 Cr (17.1%)Rejected-Finance | ₹9.2 Cr+₹1.3 Cr (17.1%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹9.4 Cr+₹1.5 Cr (19.4%)Rejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹9.4 Cr+₹1.5 Cr (19.4%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹10.4 Cr+₹2.6 Cr (32.5%)Rejected-Finance | ₹10.4 Cr+₹2.6 Cr (32.5%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹11.5 Cr+₹3.6 Cr (45.8%)Rejected-Finance NOT SPECIFIED | ₹11.5 Cr+₹3.6 Cr (45.8%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹9.2 Cr
EMD Value
₹7.8 L
Closing Date
18 Feb 2021, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
ADDN ADDN ALTN AND SPECIAL REPAIRS OF MD ACCN GRADE III and IV BLDGS UNDER GE NORTH SANTACRUZ MUMBAI PH I of II
2020_MES_370649_3
84482E8
Open Tender
Civil Works
Item Rate
455 days
GE( North) Mumbai
class S and category a(i)
6 documents required · 6 mandatory
₹3,000
GE( North) Santacruz
₹7.8 L
Yes
20 Mar 2021
28 Jan 2021
19 Feb 2021
28 Jan 2021
18 Feb 2021
4 Feb 2021
Amount
Note: This is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Disconnecting of existing PVC water storage tanks of capacity exceeding 500 Ltrs but not exceeding 1000 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Note- Cleaning repairing, etc. shall be measured separately)
Demolition of cement concrete of any description and in any positon not other specifically provided for complete all as specified and directed
M&L for roughening surfaces of old concrete roof /floor horizontal or vertical by hacking, picking, sweeping clean and washing down with water to remove dust complete all as specified and directed.
M& L for brushing neat cement slurry with 3.0kg of cement per square metre complete all as specified and as directed.
M& L for 40mm thick (average thickness) PCC 1:2:4, (type B-1), using 20mm graded coarse stone aggregates as in levelling course, laid to slope as required, finished fair and even without using extra cement complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar 1:3 on RCC roof slabs mixed with water proofing compound @ 3% (by weight) mixed with cement or as per manufacturers instruction and finishing the surfaces even and smooth to receive water proofing treatment complete all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured and paid separately.
M&L for preparation of surfaces by removing bitumen based water proofing treatment completely removed by mechanical scarification or by any other effective mechanical means and prepare the normal surface throughly be cleaning, washing and removing dust, dirt oil, grease , any loose particles etc. and applying one coat of Dr FIXIT prime seal diluted with water in the ratio 2:1 and dry minimum 2-3 hours and apply Dr FIXIT new coat in three coats at the rate 0.5Lit per Sqm in coat and dry 6 to 8 hours after each coat with and including put woven glass fibre mesh 2.5mm x 2.5mm between first coat and second coat complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of surfaces by cutting V groove all along the cracks, 5mm and above, removing all loose plaster/concrete , filling cracks with cracks filling compound of Dr FIXIT pidilite URP/Sika/Fosroc compound as approved by GE through their authorised applicator only.
M&L for applying two coats of flexible polymer acrylic water proofing coating, 1mm thick (Dry film in two coats) using Dr FIXIT pidifin 2K of M/s Pidilite Industries or equivalent as approved including necessary pond testing in sunken portion complete all as specified and as ditrected.
S&F 32mm GI pipes medium grade as in spout , not exceeding 1m each complete all as specified and as ditrected.
M&L PCC 1:5:10 type E-2 using 40mm graded coarse stone aggrgates as in filling in sunken portion complete all as specified and as ditrected.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing out of the MD land complete all as specified and directed.
M&L for brick (old size) work with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 etc complete all as specified and directed.
Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exceeding 6m mean radius in half brick walls, in cement mortar 1:4 complete all as specified and directed .
M&L for preparation of surfaces of existing concrete components including grinding /rubbing carefully by grinder without damaging the existing concrete including cleaning the surfaces by blower, removal of external plaster wherever exist including removal of debris form site.
M&L for TMT CRS bar (Fe-500D) 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed .
M&L for TMT CRS bar (Fe-500D), 8mm dia and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition).
S&F MS/TS dowel pins/staple/shear pins including drilling holes in concrete (Minimum 50mm & Maximum 150mm depth) and grouting the pins in concrete (without grouting material) complete all as specified and as directed by Engr-in-Charge.
Providing, casting and repairing of excessively damaged members with microconcrete at all levels with all leads and lift as directed including mixing, laying, levelling, finishing including curing complete. Grade of Micro-concrete to be M 40 at 28 days and shall be sourced from manufacturer's such as Renderoc RG of Fosroc or equivalent in SIKA / STP Ltd.
M & L for formwork required to pour the microconcrete/concrete using steel shutters or 12mm marine ply to have the form finish including de-shuttering etc complete all as specified and as directed by Engr-in-Charge.
M & L for providing and applying rust cleaner (Re-backler solution) to exposed corroded reinforcement @ 0.20 Litre/Sqm of make as approved by GE over prepared reinforcement, including removing concrete all around reinforcement including from behind the reinforcing bars by manual methods such as hammering the rebar, using wire brushes, chiseling, etc. and applying rust removing solution of approved make with cotton waste swab to reinforcements etc. complete all as directed by Engineer-In-Charge.
Providing and applying two coats of anticorrosive epoxy phenolic rebar protective system IPNet RB or equivalent make as approved by GE and quality comprises of resin and hardner mixed in equal proportion by volume with minimum 9-10 hours between the coats, sprinkling dry sand when 2nd coat is tacky so as to provide rough finish and ensuring air curing of minimum 10 hours after the top coat before any subsequent treatment etc. including scaffolding etc. complete all as specified and as directed by Engr-in-Charge. NOTE:- (a) New Reinforcement shall be measured and paid separately under respective item. (b) Cost of welding deemed to be included in quoted rates.
Providing and applying a priming cum bonding coat of two component Epoxy Resin confirming to ASTM-C-882-91 of make as approved by GE and quality to clean and sound concrete area by brush or any other established method by mixing base and curing agent in 2:1 proportion by weight for joining old and new concrete as per technical specifications of manufacturer. Work shall be carried out as per the manufacturers specifications & certificate on this account shall be taken from consultant and as approved by Engineer-in-charge etc.complete, Make: Nitobond EP of Fosroc or equivalent in SIKA / STP Ltd.
M&L for drilling and fixing teflon nozzles in RCC members, including drilling holes (drilling 12 mm dia, 40mm deep holes) in structural members at the intervals of 600mm c/c in staggered manner or as directed by Engr-in Charge in RCC structure elements and cleaning the holes (to clean the holes by air blower prior to fixing nozzles) and fixing of nozzles (to insert 12mm dia teflon nozzles in cleaned holes external end of nozzles (to insert 12mm dia teflon nozzles in cleaned holes external end of nozzles to be machined to receive outlet of grouting gun and fixing it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and curing the system for minimum 12 hrs) and cutting of nozzles (to cut the nozzle by chisel after completion of grouting without damaging structural elements) etc complete.
M & L for injecting low viscosity (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories, till nozzles refuses to accept the grout, including, mixing of materials (Mixing material components (Part a & b) in required quantities as per manufacturer’s instruction by weigh batching) and Grouting (Filling the grouting gun with monomer. Maintain desired pressure in the gun by air compressor; maintain the pressure at exit (4 to 5 Kg/ Sqcm) by monitoring pressure gauge at exit. Grouting the material through prefixed nozzles in the structural elements till its refusal. Sealing the nozzle with epoxy putty after the refusal. Monitoring leakages through other nozzles while grouting and seal them as per the requirement. Repeat the process for all the nozzles (the operation to be within pot life of the material) and cleaning of gun and accessories (the gun and accessories like valves, pipes and other fixtures to be cleaned with thinner after the operation to avoid jamming of the gun) etc. complete all as specified and as directed by the Engineer -in-charge.
Providing and laying 20 mm thick POLYMER MODIFIED MORTAR over identified R.C.C. members in One layer in proportion of 1:5:15 by weight of polymer of approved make, cement and filler material of approved make, blended to a required consistency and applying and finishing by floating, curing after initial setting time, including providing and inserting 10 mm mild steel shear key bars (minimum 3 nos per sqm), wherever required, bonding slurry, etc. complete as directed by Engineer-In-Charge. Make:- Renderoc SP40 of Fosroc or equivalent in SIKA / STP Ltd.
M & L for strengthening structural elements with non metallic composite fiber wrapping system comprise of uni-directional carbon fiber sheet (430 GSM) and compatible saturant Profiling: Applying compatible primer on prepared substrate, Filling the holes and uneven surface with thixotropic putty etc. complete Mechanized wetting of fiber sheet: Cutting the fabric to required size. Mixing of saturant and filling in tub area of the saturation machine. Placing the fiber on metallic rods and pass through the rollers of machine and saturant tub ensuring complete wetting (65% fiber volume fraction) of fibers. Remove the fiber on rod and place the new fiber sheet. Wrapping: Wrapping the fiber sheet to structural element at desired orientation using tamping roller to avoid any air voids etc. repeat the same procedure for multiple layer with the interval of 8 hrs. Second Coat: Applying second coat of saturant after min. 12 hrs, rectify air voids if any . (Mode of measurement: Per sq.mt of only surface area of carbon fiber sheet without lapping). Make:-Sika carbon fibre or equivalent in Fosroc / STP Ltd.
Providing and fixing carbon fiber anchor including drilling hole in the base concrete, fixing the anchor using epoxy 50X55 system spreading the anchor fibers in star pattern including appication of saturant etc. complete all as specified and as directed. Notes for Item Nos 16 to 30: (i) Refer PS clause 22 on srl page No. 106 to 108 for Structural Strengthening Methodology, Non Destructive testing after post repair, Guarantee for Structural repair and Defect Liability period. (ii)The quoted rates for item Nos 16 to 30 shall be deemed to include the provisions contained in PS clause No. 22 here-in-after and nothing extra shall be admissible to the contractor.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L for rendering 10mm thick using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound buildcare Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:6 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over masonry and concrete surfaces and finishing with sagol finish not less than 1mm thick, including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge
M&L for rendering 5 mm thick on ceiling using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Soundp last PMC-1 of M/s Sound build care Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:3 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering in ceiling, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over concrete surfaces and finishing with sagol finish not less than 1mm thick, including cleaning the surfaces, curing etc. complete all as specified & directed by Engineer-in-Charge .
M & L for rendering 15 mm thick cement plaster in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd/ or other approved equivalent make, having minimum composition of C:S : 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 10 mm thick and finishing coat of 5 mm thick final rendering with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions, including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing including provide of 150mm chicken wire mesh fixed with nails at the junction of RCC columns/walls/ beams/ lintels and brick masonry at external faces before plastering including scaffolding at any height and all safety materials required for execute work etc. complete all as per specifications & as directed by the Engineer-in-Charge.
Supply only integral water proofing compound ISI marked all as specified.
M&L for opening out cracks in wall surfaces in 'V' shape by mechanical grinder and removing the loose material. filling with crack filler of Dr. Fixit crack-X, shrinkfree or equivalent as approved by GE all as per manufacturer's instructions and finishing the surfaces to match with existing finish complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of Distemper oil emulsion over a coat of primer on plastered and other surfaces with alkali resistant priming paint over two coats of Wall care putty (total thickness not less than 1.50mm in two coats ) complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying three coat of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces of ceilings and applying three coat of white wash on ceilings complete all as specified and directed
M&L for preparation of new plastered surfaces and applying two coats of weather proof acrylic paint, plain pattern, over a coat of weather coat primer over two coats of exterior grade Wall care putty (total thickness not less than 1.50mm in two coats ) complete all as specified and directed
M&L for complete removal of existing treatment of paint on wall and applying two coats of Distemper oil emulsion over a coat of primer on plastered and other surfaces with alkali resistant primer over two coats of Wall care putty (total thickness not less than 1.50mm in two coats ) complete all as specified and directed
M&L for preparation of old painted surfaces of wall and applying two coat of plastic emulsion paint over a coat of priming paints over two coats of Wall care putty (total thickness not less than 1.50mm in two coats )l complete all as specified and directed
M&L complete removal of existing treatment on wall and applying two coats of weather proof acrylic paint, plain pattern, over a coat of weather coat primer over over two coats of exterior grade Wall care putty (total thickness not less than 1.50mm in two coats ) including preparation of surfaces complete all as specified and directed
M&L for preparation of old wooden surfaces of any description over 10cm width of girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm width of girth and applying two coat of synthetic enamel paint over one coat of pink primer paint complete all as specified and directed.
M &L for preparation of old painted surfaces of steel of any description and in any position over 10 CM width or girth, not otherwise described and applying one coat of synthetic enamel paint complete including necessary scaffolding arrangement as required at site all as specified and directed
Taking down of chowkats or frames with shutters (with out taking off shutters from the frames) not exceeding 1.5sqm each all as specified and as directed complete.
Taking down of chowkats or frames with shutters (with out taking off shutters from the frames) exceeding 1.5sqm but not exceeding 4sqm each all as specified and as directed complete.
S & F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain coloured PVC sheets and 5mm thick x 15mm wide PVC sheet beading for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of PLAIN COLOURED PVC sheet joined together with solvent cement supplying & fixing in the frame at site all as specified and as directed.
S & F IInd class HW plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
M & L for preparing surfaces of wood and wood based materials and treating back of chowkats etc. area tarred exceeding 0.1 sqm but not exceeding 0.5 sqm each with tar or coal tar black paint all as specified and and as directed.
S & F mild steel hold fast and similar small articles conforming to Fe 290-0 or E 165, all as specified and as directed.
M&L for cement concrete type C-1 1:3:6 (using 20mm graded stone aggregates) as in fixing of hold fasts including necessary form work complete all as specified.
S&F 35mm thick second class hard wood factory made plain framed panelled door shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board medium density with commercial veneering both face. The size of rail shall be as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated all as specified and directed.
S & F 30mm thick "RAJSHRI" brand or equivalent as approved by GE, factory made wire mesh solid pvc door shutter consisting of frame made out M.S. tubes of 19 gauge thickess and size of 19mm x 19mm for stiles and 15mm x 15mm for top, lock & bottom rails, M.S. frame shall have a coat of metal primer of approved make and as per manufacturers instruction. 19mm x 19mm M.S. square tubes shall be covered with heat moulded plain sheet ' C' channel made from 5mm plus minus 0.25 mm thick PC sheet of Density 600 Kg/ cbm Manufactured by an ISO -9001-2015 certified company, of size 30mm thickness, 90mm width out of which 75mm shall be flat and 15mm shall be bent in 90 degree angle on either side forming stiles, one of the 90 degree bend edge is cut from stiles as well as rails to nail from inner side of door to hide wiremesh fixing steel screws, 5mm plus minus 0.25 thick 115 mm wide PVC sheet out of which 100 mm shall be flat and 15mm shall be bent in 90 degreee on the inner side to form top and bottom rail and 130 mm wide PVC sheet out of which 100 mm shall be flat and 15mm shall be bent in 90 degree on both side to form lock rail. An additional 5mm plus minus0.25 mm thick PVC strip of 20mm width is to be stuck on the interior side of the C channel using PVC solvent cement adhesive. Panel will be of aluminium wiremesh of 24 gauge to be fitted inside area of stiles & rails. The wire mesh in top, bottom & lock rail is sealed with 15mm x 15mm tube with steel screw of size 13/6 mm 10mm (5mm x 2nos) thick PVC strip of 25mm width is to be stuck & nails on both side of G.I. wire mesh interior at the top , bottom & lock rail. 10mm thcik (5mm x 2 nos ) thick , 20mm wide cross PVC sheet as gap insert for top rail & bottom rail door to be fixed to frame with 3 nos M.S powder coated butt hinges size 100mm x 25mmx 2mm and 32mm long steeel screws drilled suitable to pass through boththe walls of the M.S. tube other hardwares should be fixed with 19x6mm size steel screws etc complete as per direction of Engineer-in-Charge, manufacturer's & drawings.
Supply and fixing 30mm thick " RAJSHRI or equivalent as approved by GE, factory made PVC cup board shutter - WOOD FREE consisting of frame made out of MS tubes of 19 guage thickness and size of 20mm x20mm for stiles as well as top, bottom and lock rail. The inside panel shall consist of 20mm thick multi chamber hollow PVC section of 1 mm wall thickness bonded using solvent cement adhesive with 5mm (plus or Minus 0.25mm) thick, one side Prelam and other side plain colour PVC sheet of Desnity 600 kg/Cbm manufactured by an ISO - 9000 certified company on both side of the inside panel. The four edges of the panel to be sealed with lapping of 10mm thick & 20 mm wide PVC sheet batten (made by sticking 2 Nos rigid foam PVC sheets of 5mm plus or Minus 0.25mm) thickness PVC solvent cement adhesive 20mm thick (5mm x 4 Nos). Thick PVC sheet to be given for lock provision at lock height. complete as per direction of Engineer-in- Charge and as per manufacturer's specification and drawing. Including Frame size of 60x50 mm, excluding handle 150mm size, Hinges stainless steel (Heavy) 100mm size, cupboard lock godrej or equivalent and screw and wall plug all as specified and as directed.
S&F 18mm thick Plain PVC Ply of any approved colour, fixed with screw/bonded with PVC adhesive solvent to PVC ply works all as directed.
S&F brass handle, fabricated & fancy type polished of size 150mm all as specified and as directed.
S&F door stopper stainless steel 150mm all as specified and as directed.
S & F heavy duty godrej lock code No. 7030 or equivalent as approved by GE, all as specified and as directed.
S&F stainless steel butt hinges, medium weight, size 100mm with ISI marked all as specified and as directed.
S&F 150mm extruded aluminium alloy handles, fabricated type, anodised all as specified and as directed.
S&F 150 mm aluminium anodised, barrel tower bolts of extruded section all as specified and as directed.
S & F 250mm aluminium anodised sliding door bolt with hasp staple (Bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding door bolts of extruded sections or cast aluminium alloy and fixed all as specified and as directed.
S & F 140mm floor door stopper of aluminum alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor all as specified and as directed.
S & F coloured aluminium powder coated sections for slidings, windows, ventilators, doors, partitions including fabrication of frame & shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc including all accessories such as glazings clips and rubber beadings for fixing glass panes / wire mesh in frame complete all as specified and directed. Note : (i) Glass panes & wiremesh will be measured & paid separately .
Supply only 4 mm thick black tinted glass ordinary quality in square exceeding 0.5 Sqm each complete all as specified and directed.
S & F aluminium anodised wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staple, complete all as specified and directed.
S&F 15 micron coloured aluminium powder coated grill design no. DG-202 of Decogrill, 10mm thk cut to required size/shape and fixed with position with aluminium beading & frame make : M/S Decogrill or equivalent with & including F sections, all as specified and directed.
S&F in repairs, aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium wire staples all as specifed and as directed.
Taking down aluminium window shutter carefully from aluminium sliding frame not exceeding 2 sqm and refixing in same position after replacing the window glass pane, wirmesh and nylon roller, rubber beading etc complete all as specified and directed. Note: Glass pane and wiremesh will be measured and paid separetely under respective item.
Taking down aluminium door shutter carfully and refixing in same position after repair/replacement of handle, floor door stoper, glass, rubber etc. adject area exceeding 1.sqm but not exceeding 2sqm each complete all as directed. Note :- Glass will be measured and paid for separately.
Supply only 5.5mm thick black tinted glass ordinary quality in square exceeding 0.5 Sqm each complete all as specified and directed.
Taking down of chowkats or frames and refixing in same opening not exceeding 1.5sqm with shutters (with out taking off shutters from the frames). All as specified and as directed.
Taking down of chowkats or frames and refixing exceeding 1.5sqm but not exceeding 4 sqm with shutters (with out taking off shutters from the frames). All as specified and as directed.
S & F Stainless steel curtain rod of 25mm dia heavy duty complete all as specified and as directed.
S & F Brass chromium plated brackets for curtain rod of 25mm dia fixed to wall complete all as specified and as directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and directed.
Demolition cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including chequred tiles complete all as specified and directed.
M&L for 75mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing/ path and finishing the surface even and fair without using extra cement all as specified and directed.
M&L for 75mm thick cement concrete (1:3:6) type C-1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
S&F non skid ceramic coloured tiles, 7 to 8mm thick, (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, laid over and including 15 thick screed bed in cement mortar 1:6 and set and jointed in neat cement slurry and pointed in coloured cement all as specified and as directed.
S&F non skid ceramic coloured tiles, 7 to 8mm thick, (square/rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in vertical surfaces fixed over and including 10 mm thick backing coat of cement mortar 1:4 and set and jointed in neat cement slurry and pointed in coloured cement all as specified and as directed.
S&F Non skid ceramic coloured tiles, 7 to 8mm thick, (square/rectangular), area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc, laid over and including 15 thick screed bed in cement mortar 1:6 and set and jointed in neat cement slurry and pointed in coloured cement all as specified and as directed.
S&F glazed ceramic coloured tiles over vertical surface of wall, 350x 250x 7mm/ 450x 350x 7mm thick (or nearest size), set and jointed in neat cement slurry and pointed in coloured cement to match with and including backing coat of 10mm thick in cement mortar (1:4) complete all as specified and directed.
M&L 20mm thick Granite (of any type) pre-polished as in cooking platforms and like fixed with neat cement slury over and including 15mm thick screed bed in cement mortar (1:4) including pointing using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L 20mm thick Granite (of any type) pre-polished as in dado, risers, skirting and like fixed with neat cement slury over and including 10mm thick rendering in cement mortar (1:4) including pointing using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for machine cut Kota stone (greenish colour, pre polished) slab in one piece as in cill /staircase treads flooring 18 to 20 mm thick, over and including cement screed base 20mm thick in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut Kota stone ( greenish colour, pre polished) slab in one piece as in risers, 18 to 20 mm thick over and including backing coat 10mm thick in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut Kota stone ( greenish colour, pre polished) slab as in skirting, 18 to 20 mm thick over and including backing coat 10mm thick in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking plateform and other similar situations, thickness of slab not exceeding 20mm, all as specified and as directed.
M& L for providing two Nos anti skid grooves over stair case treads, all as specified and as directed. . . (Note: Two nos grooves shall be measured as one length for payment)
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry or laid dry and pointed, all as specified.
M&L in repair, for machine pressed precast concrete lacquer finish interlocking paver block with grey cement and pigment, any shape and size conforming to IS 15658- 2006 of 60mm thickness, M-35 grade including 25mm thick crushed stone sand cushion below paver blocks and filling the joints with crushed stone sand complete all as specified and directed.
M&L for factory made, pre-cast, cement concrete (1:2:4) type B-1, using 20mm graded stone aggregate in kerb stone of size 300mm x 400mm x 100mm in required shape finished smooth, set in cement mortar 1:4 including excavation earth work in any type of soil complete all as specified and directed.
M&L for anti-termite treatment of soil under existing floors and junctions of wall & floor, using chemical emulsion @ one ltr per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 including white cementing and surface finishes to match the existing floors / walls all as complete.
M&L for post construction ATT of voids in masonry using chemical emulsion one ltr per hole at 300mm internals including drilling holes at 45 degree and replugging them with cement mortar 1:2 including white cementing and surface finishes to match the existing floors / walls all as complete.
M&L for post construction ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 ltr per hole by drilling 6mm dia holes at a down ward angle of 45 degree at 150mm centre to centre and sealing the same with white cement including surface finishes to match the existing surface complete all as specified.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed.
S&F 3 layer PP-R polypropylene random copolymer concealed pipes SDR- 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors complete all as specified for 40mm outer dia of pipe, all as specified and as directed.
S&F 3 layer PP-R polypropylene random copolymer concealed pipes SDR- 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors complete all as specified for 32mm outer dia of pipe, all as specified and as directed.
S&F 3 layer PP-R polypropylene random copolymer concealed pipes SDR- 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors complete all as specified for 25mm outer dia of pipe, all as specified and as directed.
S&F 3 layer PP-R polypropylene random copolymer concealed pipes SDR- 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors complete all as specified for 20mm outer dia of pipe, all as specified and as directed.
S&F 3 layer PP-R polypropylene random copolymer concealed pipes SDR- 7.4 (PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors complete all as specified for 15mm outer dia of pipe, all as specified and as directed.
S&F in repairs, bib taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
S&F in repairs, concealed stop valve, fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 15mm bore complete all as specified and directed.
Supply only pillar taps, fancy type, cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and directed.
S&F in repair, corner glass shelf 300mm Cat No- BEA-44 (Make-Prayag or equivalent as per Appx 'C' and as approved by GE)
S&F in repair, glass shelf 300mm (with ABS Brackets) Cat No- BEA-49(Make-Prayag or equivalent as per Appx 'C' and as approved by GE)
S&F in repair Peg set 6 Cat No- BEA-30(Make-Prayag or equivalent as per Appx 'C' and as approved by GE)
S&F in repair, CP brass towel Rack Cat No- BA-52 (Make-Prayag or equivalent as per Appx 'C' and as approved by GE)
S&F in repair, CP brass soap Dish Cat No- BA-15 (Make-Prayag or equivalent as per Appx 'C' and as approved by GE)
S&F in repair, CP brass towel Ring Cat No- BA-21 (Make-Prayag or equivalent as per Appx 'C' and as approved by GE)
S&F stainless steel sink with drainage board 1mm thick for kitchen with plugs, washer and waste in repairs including bedding in cement mortar on to dwarf wall or including fixing cantilever brakets and connection union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as spcified and as directed.
S&F stainless steel sink 1mm thick for kitchen or laboratory with plugs, washer and waste in repairs including bedding in cement mortar on to dwarf wall or including fixing cantilever brakets and connection union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all as speicified and as directed.
S&F aluminium anodised tubular towel rail, 20mm dia, D type 60 CM long between flanges.
S&F Swivel shower of PTMT any colour for fixing with 15mm pipe minimum weight 40gms.
S&F in repair, vitreous china wash down water closet pan (Pedestal pattern), white with 'p' or 's' trap (excluding flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. complete all as specified and directed.
Supply only plastic water closet seat black/white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F, in repair, vitreous china squatting pan, 'Orissa’ pattern, white of size 580mm x 440mm with integral foot rest, P or S trap (excluding flushing cistern and flush pipe) including provision of cement concrete (1:5:10), type E2, using 40mm graded stone aggregete complete all as specified and directed.
S&F, in repair, 10 litres capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and connection to pipe or lever etc. complete all as specified and directed.
S&F in repair, vitreous china wash basin, white, flat back of size 550mm x 400mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and directed. Note:- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately.
Supply only 32mm, waste fittings, brass chromium plated for glazed ware sink, basins, etc. with long screw shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
Supply only PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
Supply only PVC waste pipe 32mm bore of size 450mm to 600mm long complete all as specified and directed.
Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required for 110mm and 75mm bore of pipe complete all as specified and directed.
S & F 110 mm dia bore PVC (SWR) pipe (Type 'B') single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F PVC (SWR) bend any radius for 110 mm bore pipe incl jointing material complete all as specified and directed.
S & F PVC (SWR) branch piece, single (single Y) equal or unequal for 110mm dia bore incl jointing material complete all as specified and directed.
S & F PVC (SWR) branch piece, double (double Y) equal or unequal for 110mm dia bore incl jointing material complete all as specified and directed.
S & F PVC (SWR) junction single, (Single T) equal or unequal for 110mm dia bore as specified and directed.
S&F PVC 75mm dia (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls.
S & F PVC (SWR) bend any radius for 75 mm bore pipe incl jointing material complete all as specified and directed.
S & F PVC (SWR) branch piece, single (single Y) equal or unequal for 75mm dia bore incl jointing material complete all as specified and directed.
S & F PVC (SWR) branch piece, double (double Y) equal or unequal for 75mm dia bore incl jointing material complete all as specified and directed.
S & F PVC (SWR) junction single, (Single T) equal or unequal for 75mm dia bore as specified and directed.
M&L for 63 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement.
S & F PVC (SWR) vent cowl equal or unequal for 110mm dia bore as specified and directed.
S&F in repair PTMT grating doom over Nahani trap and floor trap of 100mm Dia
S&F rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates etc. FE410W(GdeE-250 quality B), all as specified and as directed.
S & F pre-painted galvalume aluminium zinc coated GI based colour corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instruction/recommendations complete all as specified and directed.
Preparing new steel surfaces of any description exceeding 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified.
M & L for Rotational moulded polyethylene water storage tanks of capacity 1000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
M & L for Rotational moulded polyethylene water storage tanks of capacity 500 Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m deep and getting out in soft / loose soil complete all as specified and as directed.
M & L for 150 mm dia RCC pipes of class NP-2 laid and jointed with collars etc complete all as specified and as directed.
M & L for cement concrete of Type B-2 (1:2:4) using 40 mm graded stone aggregate as in foundations, fillings and mass concrete as the foundation of manholes complete all as specified and as directed by Engnr-in-Charge
M & L for providing cement concrete of type B-1 (1:2:4), using 20 mm graded stone aggregates, as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in benching of manhole, surface channels and drains including necessary form work complete all as specified and as directed.
M&L concrete bed to 150 mm sewage pipes in cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M & L for extra for forming fair finished drain or channel, 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and as directed.
M&L for providing precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) for manhole / drain covers etc. set in cement morter 1:6, finishing the exposed faces even and smooth without using extra cement including demolition of existing unserviceable RCC covers and removing debris out side MD land complete all as specified and as directed. Note :- Reinforcement shall be measured and paid separately).
M & L for cutting/Joining in to existing manholes for connecting new drains making good to pipe of internal dia 150/200 mm and rendering cutting out existing benching for and forming branch channel (1/2 Round or 3/4 Section) in cement concrete 1:2:4, type B-1 smooth finished and reforming benching as required complete all as specified and as directed.
M & L for PCC in roof Kerbs, coping, rounded or chamfered on edges type B1 (1:2:4) using 20 mm graded aggregate all as specified and directed by Engineer in Charge
Returning, filling in including spreading, levelling, watering and well ramming in layer n. exc 25cm in soft / loose soil complete all as specified and as directed by Engr-in-Charge.
Removing excavated soil to a distance exceeding 1.5 Km but not exceeding 5 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engr-in-Charge.
S & F 20 to 25mm thick machine cut, machine polished kota stone as in flooring laid over and including 20mm thick cement screed bed in CM 1:6 etc. complete all as specified and directed.
S & F framed work such as grills, grating etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings and similar work conforming to Fe-290 Gd E-165 as per direction of Engr-in-Charge
M&L solid PVC Chajja with 10mm thick plain sheet 600mm projection and 100mm drop at end, fixed angle iron frame to walls with 12mm dia dash thrufastners at distaance not exceeding 30 cm c/c all as specified and directed by Egnr-in- charge.
Removing of Loose disturbed & disintegrated concrete surface of RCC beams, columns, Chajjas, lintels, ceiling etc. and cleaning exposed rusted reinforcement, removing rusted scales by chipping and cleaning by wire brushes and applying anti corrosive epoxy coating as per manufactures instructions on prepared surface to receive gunninting including necessary scaffolding and preparing to support damaged structural members, supply and tying welded wire mesh 75 mm × 75 mm × 3 mm, binding with GI wire 22 gauge to reinforcement, applying cement slurry uniformly to exposed surfaces and guniting using CM 1:3 average guniting not less than 25 mm and finishing the surface in 10 mm thick plaster of CM 1:3, trowled even and smooth finish, without using extra cement and removing debris outside MD land to distance any where outside as directed by Enginner-in-Charge
S&F Gun metal gate valves 25mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F Gun metal gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F 20mm dia of ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed complete all as specified and as directed.
Material and labour for 20-25mm thick machine cut polished cudappa stone for steps, jambs, pillers, window cills, cooking platform and counter platform for wash basin laid over and including screed bed 15mm thick in cement mortar 1:6 including cutting as per wash basin shape, and moulding provided as directed by Engr-in-Charge.
S&F PCC type B-1, 1:2:4 using 20mm graded stone aggregate in drain cover, chulla hood, chajja, shelves and similar article complete all as specified and directed by Engineer-in-charge.
M & L for PCC type B-1 (1:2:4) using 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps, plinth course, parapet and coping etc all as directed.
Use and waste to existing any RCC structure by using steel plate and steel props at any description & position and all as specified & directed by Engineer in charge
Taking down carefully existing unserviceable aluminium point wiring (light, fan, sockets or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials from site and making good disturbed surfaces of walls, floors, ceilings all as specified and as directed.
M & L for point wiring with single core FRLSH PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including PVC casing and capping ( not less than 20mm wide) complete with all fittings and accessories including, ISI marked with GI sunken boxes 1.6mm thick, 60mm deep with earth dolly duly, covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one light point/fan point/exhaust fan point, controlled by one, one way switch of 5 Amps.
M & L for point wiring with single core FRLSH PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including PVC casing and capping ( not less than 20mm wide) complete with all fittings and accessories including, ISI marked with GI sunken boxes 1.6mm thick, 60mm deep with earth dolly duly, covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one 3/5 pin socket out let 5Amps on the same board with other switches .
M & L for point wiring with single core FRLSH PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including PVC casing and capping ( not less than 20mm wide) complete with all fittings and accessories including, ISI marked with GI sunken boxes 1.6mm thick, 60mm deep with earth dolly duly, covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one 3/5 pin socket out let 5Amps on independent board .
M & L for point wiring with single core FRLSH PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including PVC casing and capping ( not less than 20mm wide) complete with all fittings and accessories including, ISI marked with GI sunken boxes 1.6mm thick, 60mm deep with earth dolly duly, covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one light point controlled by two, two way switches 5 Amps.
M & L for point wiring with single core FRLSH PVC insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including PVC casing and capping ( not less than 20mm wide) complete with all fittings and accessories including, ISI marked with GI sunken boxes 1.6mm thick, 60mm deep with earth dolly duly, covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets, fan regulators etc including 1.5 Sqmm (22/0.30 mm) 1100 V grade FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one bell point controlled by one bell switch 5 Amps.
M & L for point wiring (concealed type) complete with and including single core FRLSH PVC insulated flexible bright annealed multi stranded copper conductor cables 2.5 Sqmm (36x0.30mm), 1100 volts grade drawn through and including PVC casing and capping (not less than 20 mm) including fittings and accessories including, ISI marked with GI sunken boxes 1.6mm thick, 60mm deep with earth dolly duly covered with 3mm thick industrial laminated sheet top cover suitable for mounting switches, sockets etc including 2.5 Sqmm (36/0.30 mm) 1100 V grade FRLSH PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified, directed for one 3pin, 15Amp socket outlet on independent board.
S&F ceiling rose surface backalite three terminal, 50 mm dia PVC/polycorbonate insulated body including PVC mounting block white/ ivory /urea finish complete all as specified and directed.
S&F switch piano flush type polycorbonate 5 Amps single pole one way, 230 volts all as specified and as direcrted
S&F socket outlet polycorbonate 5 Amps, 2 in 1 , 3 pin 5Amps flush type all as specified and as direcrted
S&F socket outlet, 2 in 1, 5 and 15 Amps multipurpose flush type complete all as specified and as direcrted
S&F switch piano flush type polycorbonate 15/16 Amps single pole one way, 230 volts all as specified and as direcrted
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc 120 W, step type, suitable for operation on 230Volts 50Hz AC supply complete all as specified and directed.
S & F LED tube along with CRCA LED Batten complete LED light fitting fixture including LED Tube and Batten , LED Tube fitting consist of Polycarbonate housing with extruded aluminium heatsink for mounting LED chip , LED tube system wattge consist of 18W / 20 W , 140V -260V AC, System Lumen Output min 1800 Lumen in 18W and 2000 lumen in 20W with 5700 - 6500 K CCT with PF > 0.95 CRI > = 80 and with < = 10 % THD , with Min 2.5 KV Surge protection in Built and LED Tube with BIS R Registraion no / mark mandatory . LED Batten consist of Powder coated CRCA box type batten with decorative end caps should be supplied for installing above LED tubes.
Supply, fixing and connecting from ceiling rose with 3 core flexible copper wire of required length, LED (1x1) 15W, ultre modern designed architechural recess mounting LED luminaire which provides sift light and glare free symmetrical illumination suitable for armstrong /grid ceiling with high brightness PF > 0.95 CRI > = 80 and with < = 10 % THD , with Min 2.5 KV Surge protection in Built and LED including fixing material all as directed.
Supply & fixing 2x6W double head mirror light LED batten fixture with IP20 moisture protection, premium opaque glass housing and chrome mounts, LED fixture system wattage of 06W each, 140V-260V AC system Lumen output min 600 Lumen in 06W with 5700-6000KCCT, all as directed.
S & F sheet metal enclosure with two pin and earth plug socket and including MCB SP 20A complete all as directed.
S & F 20 Watt LED building security light pressure die cast alluminium alloy for housing (heat sink) for effective thermal management with LED PC lens LED street light system wattage cinsist of 20Watt, 140-260V AC, system lumen output min 2250 Lumen in 20 W with 5700-6500K CCT with PF > 0.95CRI >=70 and with < = 10 % THD , with Min 2.5 KV Surge protection, IP65 grade of protection and LED street light with BIS R Registration number all as directed.
S & F street light brackets fabricated out of GI tubing light grade 25mm bore bend to the shape as directed and of length 0.75m complete with mounting MS clamp of flat iron size 40x5mm of suitable length 02 pairs including nut and bolts etc of suitable size, including taking down old unserviceable one all as specified.
S & F bulk head light fittings including LED lamp 10 W all as specified and as directed.
S & F lamp holder, PVC Polycorbonate type with back plate suitable for batten/angular fittings all as specified and as directed.
S & F LED bulb, 9W, retrofit type for lamp holder/bulk head light fittings all as specified and as directed.
S & F sub main wiring with approved colour coding as per IS with two single core 10Sqmm FRLSH PVC insulated, copper conductor cable 1100 Volts grade multistranded, unsheathed conductor drawn through and including and one single core 10 sqmm FRLSH PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694 / 1990 drawn through & including non metalic rigid PVC casing and capping including accessories all as specified and as directed. Note: Two runs of 10Sqmm, one run of 10Sqmm cable and one run of casing and capping will be measured as one unit.
S & F sub main wiring with approved colour coding as per IS with two single core 2.5Sqmm FRLSH PVC insulated, copper conductor cable 1100 Volts grade multistranded, unsheathed conductor drawn through and including and one single core 2.5 sqmm FRLSH PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694 / 1990 drawn through & including non metalic rigid PVC casing and capping including accessories all as specified and as directed. Note: Two runs of 2.5Sqmm, one run of 2.5Sqmm cable and one run of casing and capping will be measured as one unit.
S&F Bell, ding dong type suitable for AC 230 volts,50 Hz, single pole complete all as specified and directed.
S&F switch bell push 5 Amps flush type, one way, 230 volts all as specified and as direcrted
Taking down carefully existing unserviceable MCB DB/TPN/ main switch of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed.
S&F Distribution board sheet metal enclosure double door, factory made with IP43 grade protection fixed flush with wall inside the nitches for mounting MCBs, 230 Volts with bus bars with front openable cover Single pole and neutral 12 way with tinned copper bus bar of suitable size 100A consumer unit & prewired complete all as specified and as directed.
S&F Distribution board sheet metal enclosure double door, factory made with IP43 grade protection fixed flush with wall inside the nitches for mounting MCBs, 230 Volts with bus bars with front openable cover Single pole and neutral 8 way with tinned copper bus bar of suitable size 100A consumer unit & prewired complete all as specified and as directed.
S&F Distribution board sheet metal enclosure double door, factory made with IP43 grade protection fixed flush with wall inside the nitches for mounting MCBs, 230 Volts with bus bars with front openable cover Single pole and neutral 4 way with Copper bus bar of suitable size 100A consumer unit & prewired complete all as specified and as directed.
S&F MCB Single pole and neutral 240 volts 32 Amps 10 KA, 'C' curve complete all as specified and directed. Make as given in Appendix 'C'.
S&F MCB Single pole 240 volts 6-32 Amps 10 KA, 'C' curve complete all as specified and directed. Make as given in Appendix 'C'.
S&F MCB TPN 240 volts 63 Amps 10 KA, 'C' curve complete all as specified and directed. Make as given in Appendix 'C'.
S&F MCB blanking plate complete all as specified and directed. Make as given in Appendix 'C'.
S&F Distribution board VTPN, 4 way double door IP 43 grade protection, 415 Volts with provision for DPX 125MCCB as incommer and SP/TP MCB as outgoing and electrically connecting up complete all as specified and directed by Engineer-in-charge . Make as given in Appendix 'C'.
S&F MCCB, 125Amps, 35KA, 4 pole with thermal adjustable & magnatic settings complete all as specified and directed. Make as given in Appendix 'C'.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised steel earthing wire 4mm dia by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to earth test point, GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including concrete pit in PCC (1:3:6) type C-1 , RCC 1: 2 : 4 type B-1 earth pit with cover slab of size 450x450x50mm reinforced with 8mm TMT @ 100 centre to centre both ways including one handle for lifting made of 8mm dia MS bar, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
Taking down ceiling fan of any sweep and Make by disconnecting electric connection , dismantling blades, down rod and removing ceiling fan to MES strore yard of AGE E/M (N) for checking, complete all as specified and as directed.
M & L for preparation of surfaces of ceiling fan of any sweep and Make, complete body , blade, down rod, cleaning dust, dirts etc, filling cavities with filler and applying one coat DUCCO paint with spray machine including writting MES No. in Black paint complete all as specified and as directed.
Hanging only ceiling fan of any sweep and make and connecting up with electric connection, from ceiling rose / connector to fan , complete all as specified and as directed.
M & L for replacement of flexible multistranded copper conductor of 3 core 0.5Sqmm for electric connection of fan complete all as specified and as directed.
M & L for replacement of flexible multistranded copper conductor of 3 core 1.5Sqmm for electric connection of fan complete all as specified and as directed.
Dismantling and taking down old unserviceable meter cabinet of any description after necessary disconnection of all incoming and outgoing connections complete and supply , install, testing and commissioning of indoor type (MS angle fitted with bolts and nuts) meter cabinet of suitable size made out of 2mm thick CRCA MS sheet with front door having glass window for viewing KWH meter and other doors shall be opeque. All doors should have gasket and locking arrangement. The cabinet shall be painted both internally and externally with two coats of synthetic enamel paint ( Shade smoke grey) over a coat of red oxide metal primer duly spreyed with the compressor . The cabinet shall be dust and vermin proof with degree of protection IP 43. The cabinet shall be comprising with the following accessories:-
(a) MCCB 63 Amps, FP, 415V, 50Hz ICU 25 KA thermally adjustable between 70-100% and fixed magnatic release.
(b) Aluminium bus bar of cross section 40x5mm duly mounted on FRP/DMC insulators and necessary drilling ( 1 incomming & minimum 4 outgoing) for connections and duly covered with heat shrinkable PVC sleeves of stranded colour code -04 Nos
(c) Single phase KWh meter of rating 10-60Amps, base mounting, electronic temper proof type with optical port suitable for AC 230 Volts, 50Hz supply. - 10 Nos
(d) MCB SPN 32 Amps, 230 Volts , 50 Hz, 10 KA, 'C' curve -09 No.
(e) MCB SPN 16 Amps, 230 Volts , 50 Hz, 10 KA , 'C' curve-01 No.
(f) Internal wiring of meter/MCB/Cable connector, shall be carried out with 10 Sqmm multiflexible copper wire with FR grade PVC insulation of 1100 Volts rating including necessary lugs/nuts/bolts/washers etc.
Dismantling and taking down old unserviceable meter cabinet of any description after necessary disconnection of all incoming and outgoing connections complete and supply, install, testing and commissioning of indoor type (MS angle fitted with bolts and nuts) meter cabinet of suitable size made out of 2mm thick CRCA MS sheet with front door having glass window for viewing KWH meter and other doors shall be opeque. All doors should have gasket and locking arrangement. The cabinet shall be painted both internally and externally with two coats of synthetic enamel paint (Shade smoke grey) over a coat of red oxide metal primer duly spreyed with the compressor . The cabinet shall be dust and vermin proof with degree of protection IP 43. The cabinet shall be comprising with the following accessories:-
(a) MCCB 63 Amps, FP, 415V, 50Hz ICU 25 KA thermally adjustable between 70-100% and fixed magnatic release.
(b) Aluminium bus bar of cross section 40x5mm duly mounted on FRP/DMC insulators and necessary drilling (1 incomming & minimum 4 outgoing) for connections and duly covered with heat shrinkable PVC sleeves of stranded colour code -04 Nos
(c) Single phase KWh meter of rating 10-60Amps, base mounting, electronic temper proof type with optical port suitable for AC 230 Volts, 50Hz supply. - 9 Nos
(d) MCB SPN 32 Amps, 230 Volts , 50 Hz, 10 KA, 'C' curve -08 No.
(e) MCB SPN 16 Amps, 230 Volts , 50 Hz, 10 KA, 'C' curve -01 No.
(f) Internal wiring of meter/MCB/Cable connector, shall be carried out with 10 Sqmm multiflexible copper wire with FR grade PVC insulation of 1100 Volts rating including necessary lugs/nuts/bolts/washers etc.
Dismantling and taking down old unserviceable meter cabinet of any description after necessary disconnection of all incoming and outgoing connections complete and supply, install, testing and commissioning of indoor type (MS angle fitted with bolts and nuts) meter cabinet of suitable size made out of 2mm thick CRCA MS sheet with front door having glass window for viewing KWH meter and other doors shall be opeque. All doors should have gasket and locking arrangement. The cabinet shall be painted both internally and externally with two coats of synthetic enamel paint (Shade smoke grey) over a coat of red oxide metal primer duly spreyed with the compressor . The cabinet shall be dust and vermin proof with degree of protection IP 43. The cabinet shall be comprising with the following accessories:-
(a) MCCB 63 Amps, FP, 415V, 50Hz ICU 25 KA thermally adjustable between 70-100% and fixed magnatic release.
(b) Aluminium bus bar of cross section 40x5mm duly mounted on FRP/DMC insulators and necessary drilling (1 incomming & minimum 4 outgoing) for connections and duly covered with heat shrinkable PVC sleeves of stranded colour code -04 Nos
(c) Single phase KWh meter of rating 10-60Amps, base mounting, electronic temper proof type with optical port suitable for AC 230 Volts, 50Hz supply. - 5 Nos
(d) MCB SPN 32 Amps, 230 Volts , 50 Hz, 10 KA, 'C' curve -04 No.
(e) MCB SPN 16 Amps, 230 Volts , 50 Hz, 10 KA, 'C' curve -01 No.
(f) Internal wiring of meter/MCB/Cable connector, shall be carried out with 10 Sqmm multiflexible copper wire with FR grade PVC insulation of 1100 Volts rating including necessary lugs/nuts/bolts/washers etc.
Taking down carefully old unserviceable lightning protection (AL strip, Air temination rod, pipe, etc) complete and making good disturbed surfaces of wall/roof etc all as specified.
S & F single pointed air termination aluminium rod, 12mm dia, 300mm long and fixed all as specified.
S & F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, all as specified and as directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised steel earthing strip 32x6mm by means of bolts, nuts & checknuts and washers etc; GI pipe 40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to earth test point, GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including concrete pit in PCC (1:3:6) type C-1 , RCC 1: 2 : 4 type B-1 earth pit with cover slab of size 450x450x50mm reinforced with 8mm TMT @ 100 centre to centre both ways including one handle for lifting made of 8mm dia MS bar, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
S & F Galvanised iron strip 32 x 6mm buried in ground complete all as specified and as directed.
M & L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw, complete all as specified and as directed.
S&F GI pipes medium grade 25mm dia bore , ISI marked, duly grouted on the roof for fixing air terminal complete all as specified and as ditrected.
M & L for Precast cement concrete solid block masonry with solid blocks, Type B1 (1:2:4) using 20mm graded coarse stone aggregates, exceeding 10cm width and setting in cement mortar 1:4 complete all as specified and as directed.
Nexus Infratech
SOOD ASSOCIATES PVT LTD
Mukund Enterprises Private Limited
United Sales Corporation
MAHENDRA REALTORS AND INFRSTRUCTURE PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .