| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LQualified 1 97 VINAY KHAND GOMTI NAGAR GOMTI NAGAR GORAKHPUR UTTAR PRADESH 273001 UDYAM UP 50 0014123 | GORAKHPUR | UTTAR PRADESH | 273001 | ₹4.8 L | L1 | Qualified MII |
| 2 | L2₹5.0 LQualified S 5 38 23 PLOT NO 23 VINDHYAVASINI NAGAR ORDERLY BAZAR VARANASI 221002 VINDHYAVASINI NAGAR ORDERLY BAZAR MAHAVEER MANDIR ROAD ORDERLY BAZAR VARANASI UTTAR PRADESH 221002 UDYAM UP 75 0015982 | VARANASI | UTTAR PRADESH | 221002 | ₹5.0 L | L2 | Qualified MII |
| 3 | L3₹5.2 LQualified S 75 GOLE MARKET MAHANAGAR S 75 MAHANAGAR EXTENTION LUCKNOW UTTAR PRADESH 226006 | LUCKNOW | UTTAR PRADESH | 226006 | ₹5.2 L | L3 | Qualified MII |
| 4 | Disqualified SHOP NO 5 MM PLAZA B 1 MINI MARKET JANAK PURI NEW DELHI DELHI 110058 UDYAM DL 11 0005707 07AEFPG8829N1ZY B B R M MSME STATUS AS NOT VERIFIED | WEST DELHI | DELHI | 110058 | - | - | Disqualified MSE, MII, Category: OBC |
| 5 | Disqualified 4TH FLOOR 9A NEW JANPATH ASHOK MARG LUCKNOW 226001 NEW JANPATH HAZRATGANJ HAZRATGANJ LUCKNOW UTTAR PRADESH 226001 UDYAM UP 50 0001018 09AACCV7050J2Z1 B R MII STATUS AS VERIFIED | LUCKNOW | UTTAR PRADESH | 226001 | - | - | Disqualified MII |
Tender Value
₹5.9 L
EMD Value
₹5,800
Closing Date
17 Nov 2025, 8:00 pmClosed
Supply of Cassette AC
3.0 TR SINGLE PHASE ONLY BEE 5- Star Inverter AC
Supply of Hi-Wall Split AC
1.5 TR BEE 5- Star Inverter AC
Supply of Hi-Wall Split AC
1.0 TR BEE 5- Star Inverter AC
Installation of 3.0 TR Cassette AC
Installation of 2.0 or 1.5 or 1.0 TR Hi-Wall Split AC
Supply and Installation of copper refrigerent pipes with min thickness 0.7 mm or higher for 3.0 TR CACs
Supply and Installation of copper refrigerent pipes with min thickness 0.7 mm or higher for 1.5 or 1.0 TR SACs
Supply and Installation of interconnecting wires for 3.0 TR Cassette Acs
Supply and Installation of interconnecting wires for 1.5 or 1.0 TR Hi-wall Split Acs
Supply and Installation of 25 mm PVC drain Pipes with insulation
Supply and Installation of MS Angle for Outdoor units
Supply and Installation of 4.0 KVA Stabliser having copper winding with voltage range of 130 - 280V
Supply and Installation of 5.0 KVA Stabliser having copper winding with voltage range of 130 - 280V
Dismantle shifting and reinstallation of old existing 2.0 or 1.5 or 1.0 TR Hi-wall
Dismantle and placement at designated place of old existing 2.0 or 1.5 or 1.0 TR Hi-wall split Acs
8561772
GEM/2025/B/6867678
Two Packet Bid
Supply of Cassette AC, 3.0 TR SINGLE PHASE ONLY BEE 5-
30 days
231216, STATE BANK OF INDIA, REGIONAL BUSINESS OFFICE - VII, ROBERTSGANJ -
Total value wise evaluation
BOQ
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Supply of Cassette AC, 3.0 TR SINGLE PHASE ONLY BEE 5-Star | LG / 3.0 TR SINGLE PHASE ONLY BEE 5-Star Inverter AC | 8415 | 3 pieces | 91,055 | 273,165 |
| Supply of Hi-Wall Split AC, 1.5 TR BEE 5-Star Inverter AC | CARRIER / Split AC, 1.5 TR BEE 5-Star Inverter AC | 8415 | 1 pieces | 38,055 | 38,055 |
| Supply of Hi-Wall Split AC, 1.0 TR BEE 5-Star Inverter AC | CARRIER / Split AC, 1.0 TR BEE 5-Star Inverter AC | 8415 | 1 pieces | 32,995 | 32,995 |
| Installation of 3.0 TR Cassette AC | - | HSN not specified by seller | 3 pieces | 2,275 | 6,825 |
| Installation of 2.0 or 1.5 or 1.0 TR Hi-Wall Split AC | - | HSN not specified by seller | 2 pieces | 1,155 | 2,310 |
| Supply and Installation of copper refrigerent pipes with min | - | HSN not specified by seller | 40 meters | 925 | 37,000 |
| Supply and Installation of copper refrigerent pipes with min | - | HSN not specified by seller | 45 meters | 795 | 35,775 |
| Supply and Installation of interconnecting wires for 3.0 TR Cassette | - | HSN not specified by seller | 46 meters | 115 | 5,290 |
| Supply and Installation of interconnecting wires for 1.5 or 1.0 TR Hi- | - | HSN not specified by seller | 52 meters | 105 | 5,460 |
| Supply and Installation of 25 mm PVC drain Pipes with insulation | - | HSN not specified by seller | 60 meters | 105 | 6,300 |
| Supply and Installation of MS Angle for Outdoor units | - | HSN not specified by seller | 6 pieces | 795 | 4,770 |
| Supply and Installation of 4.0 KVA Stabliser having copper winding | - | HSN not specified by seller | 2 pieces | 4,555 | 9,110 |
| Supply and Installation of 5.0 KVA Stabliser having copper winding | - | HSN not specified by seller | 3 pieces | 4,665 | 13,995 |
| Dismantle shifting and reinstallation of old existing 2.0 or 1.5 or 1.0 | - | HSN not specified by seller | 2 pieces | 1,795 | 3,590 |
| Dismantle and placement at designated place of old existing 2.0 or | - | HSN not specified by seller | 2 pieces | 1,795 | 3,590 |
6 documents required · 6 mandatory
3 yrs
₹2 L
80%
₹5,800
18 Jan 2026
7 Nov 2025
17 Nov 2025
Supply of Cassette AC, 3.0 TR SINGLE PHASE ONLY BEE 5-Star | Brand:LG | Model:3.0 TR SINGLE PHASE ONLY BEE 5-Star Inverter AC | HSN:8415 | Qty:3 pieces | UnitPrice:91,055 | Amount:273,165
Supply of Hi-Wall Split AC, 1.5 TR BEE 5-Star Inverter AC | Brand:CARRIER | Model:Split AC, 1.5 TR BEE 5-Star Inverter AC | HSN:8415 | Qty:1 pieces | UnitPrice:38,055 | Amount:38,055
Supply of Hi-Wall Split AC, 1.0 TR BEE 5-Star Inverter AC | Brand:CARRIER | Model:Split AC, 1.0 TR BEE 5-Star Inverter AC | HSN:8415 | Qty:1 pieces | UnitPrice:32,995 | Amount:32,995
Installation of 3.0 TR Cassette AC | HSN:HSN not specified by seller | Qty:3 pieces | UnitPrice:2,275 | Amount:6,825
Installation of 2.0 or 1.5 or 1.0 TR Hi-Wall Split AC | HSN:HSN not specified by seller | Qty:2 pieces | UnitPrice:1,155 | Amount:2,310
Supply and Installation of copper refrigerent pipes with min | HSN:HSN not specified by seller | Qty:40 meters | UnitPrice:925 | Amount:37,000
Supply and Installation of copper refrigerent pipes with min | HSN:HSN not specified by seller | Qty:45 meters | UnitPrice:795 | Amount:35,775
Supply and Installation of interconnecting wires for 3.0 TR Cassette | HSN:HSN not specified by seller | Qty:46 meters | UnitPrice:115 | Amount:5,290
Supply and Installation of interconnecting wires for 1.5 or 1.0 TR Hi- | HSN:HSN not specified by seller | Qty:52 meters | UnitPrice:105 | Amount:5,460
Supply and Installation of 25 mm PVC drain Pipes with insulation | HSN:HSN not specified by seller | Qty:60 meters | UnitPrice:105 | Amount:6,300
Supply and Installation of MS Angle for Outdoor units | HSN:HSN not specified by seller | Qty:6 pieces | UnitPrice:795 | Amount:4,770
Supply and Installation of 4.0 KVA Stabliser having copper winding | HSN:HSN not specified by seller | Qty:2 pieces | UnitPrice:4,555 | Amount:9,110
Supply and Installation of 5.0 KVA Stabliser having copper winding | HSN:HSN not specified by seller | Qty:3 pieces | UnitPrice:4,665 | Amount:13,995
Dismantle shifting and reinstallation of old existing 2.0 or 1.5 or 1.0 | HSN:HSN not specified by seller | Qty:2 pieces | UnitPrice:1,795 | Amount:3,590
Dismantle and placement at designated place of old existing 2.0 or | HSN:HSN not specified by seller | Qty:2 pieces | UnitPrice:1,795 | Amount:3,590
contract_GEMC-511687775984248.pdf
GEM_CONTRACT • 0.13 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8561772.pdf
GEM_BID
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
boq_-_ac_work_at_malda_branch_2025-11-07-18-58-07_e54e15b9a1d70fb60787c8b547d7d873.pdf
BOQ
boq_item_file_malada_2025-11-07-18-58-07_24b19a9f9969b59603f823459c546c07.csv.pdf
BOQ
Download all tender documents and submit your bid