| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-Finance LANE NO 05 HNO 56 SHIV VIHAR TALAB TILLO JAMMU | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹2.1 L+₹4,999.30 (2.41%)Rejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹2.2 L+₹14,997.90 (7.23%)Rejected-Finance LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L3 | Rejected-Finance Being L3 |
Tender Value
₹2.5 L
EMD Value
₹4,999
Closing Date
27 Feb 2026, 2:00 pmClosed
Executive Engineer
Executive Engineer PWD R and B Gandhi Nagar I/c UWD
Special electrical repair and renovation to be carried out in the Centre for IT Enabled Services at New University Campus
2026_UDJK_303735_1
enit144 dated 11-02-2026
Open Tender
Electrical Works
Percentage
90 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹708
Yes
Executive Engineer PWD R and B Gandhi Nagar I/c UW
₹4,999
5 Mar 2026
18 Feb 2026
2 Mar 2026
18 Feb 2026
27 Feb 2026
18 Feb 2026
Part-A (Sanctioned Schedule items) Based on CPWD Schedule 2022 Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG/) Equivalent make of required specification to be approved by the Engineer In charge 25 mm dia
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/HPL/KEI/polycab/) Equivalent make of required specification to be approved by the Engineer In charge) i.2x1.5 Sq mm +1x1.5 Sq mm
ii.2x2.5 Sq mm + 1x2.5 Sq mm
iii.2x6 Sq mm + 1x6 Sq mm
iv.4x6 Sq mm + 2x6 Sq mm
Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing of following ratings and poles 240/415 volts Isolators in the existing MCB DB complete with connections, testing and commissioning etc. as required (Make Havells /Legrand /Anchor/ C&S/L&T/ Siemen/IA/HPL/Standard Equivalent make of required specification to be approved by the Engineer In charge) a.40 Amp 240 volt Double Pole.
b..63 Amp 415 volt Four Pole Isolator.
Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100mm x 100mm x 60mm deep
200mm x 125mm x 60mm deep
Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /HPL/Great White/ Equivalent make of required specification to be approved by the Engineer In charge)
Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL/ Anchor/Great White/ Equivalent make of required specification to be approved by the Engineer In charge)
Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL / Anchor /SSK/ C&S/Great White/ Equivalent make of required specification to be approved by the Engineer In charge)
Supplying and fixing following ways and single pole and neutral,sheet steel,MCB distribution board,240V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators) ( Havells/Anchor /I.A /HPL) i. 16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral,sheet steel,MCB distribution board,415 V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators) ( Havells/Anchor /I.A /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 6 way(4+18), Double door
Re-wiring for light point/fan point/call bell point exhaust fan point with 1.5 Sqm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Wire Make ISI Marked Havells/Anchor/KEI/Polycab ) (Conduit Make - ISI Marked Anchor/High Power /AKG) Group ‘B’
ii.2x6 sqmm
Part-B (Non Schedule items) Supplying and fixing following ways horizontal type MCB Distribution Board 415V on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. i.4 way, For A.C Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge
Providing/fixing 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissioning complete Job. (Havells/Anchor/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 1 to 3 star rated energy efficient .(Make: Havells /Anchor/USHA /Crompton) Equivalent make of required specification to be approved by the Engineer In charge)
Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) 4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete .
Supply, installation, testing, commissioning of heavy duty 300 mm sweep BEE 3 to 5 star rated energy efficient exhaust fan.Make: ( Anchor/Havells/Bajaj/Crompton/ Equivalent make of required specification to be approved by the Engineer In charge)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_986427.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .