Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹98.8 LAccepted-AOC AT BRAHMAN SASAN PO TALCHER DIST ANGUL ODISHA 759102 | TALCHER | ANGUL | ODISHA | 759102 | L-1 | Accepted-AOC Awarded due to becoming techno-commercially eligible L-1 bidder. | |
| 2 | Rejected-Technical AT PO SURYA NAGAR HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | - | Rejected-Technical Rejected due to non-submission of Valid Electrical Contractors License even after recycle |
Tender Value
₹94.6 L
EMD Value
₹1.2 L
Closing Date
1 Jan 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Day to Day maintenance, dismantling and erection of power line of 11KV/3.3KV/440V grade of different feeders along with maintenance of lighting circuit under Balanda Colony of Jagannath OCP for a period of Two years on as and when required basis
2023_MCL_295563_1
GM(JA)/EnM/ e-Tender/23-24/E-605/31 dtd 08/12/23
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
Talcher
AS PER NIT
6 documents required · 6 mandatory
₹1.2 L
4 Mar 2024
11 Dec 2023
3 Jan 2024
12 Dec 2023
1 Jan 2024
12 Dec 2023
12 Dec 2023 - 20 Dec 2023
Amount
Scope of Work: (1) The job includes Day to day Maintenace, Dismantling and Erection of of Power line 11KV/3.3KV/440V/230V grade of different feeders of Balanda Colony with dismantling and erection of lighting line & light fittings along with Day to Day checking, repair, maintenance and fault rectification in the power supply system of various residential/ Non-residential quarters including maintenance of overhead lines feeding power supply to colony, day to day maintenance and rectification of different feeders, running breakdown maintenance of feeder switches, etc. and maintenance of power supply at Balanda Substation, Light Vehicle Substation, Filter Bed, Rescue Station, Bus stand, Balanda Dispensary, Market, Club, JACL Lab and other miscellaneous places under administrative Control of Balanda Colony of Jagannath OCP. (2) The manpower engaged should be VT trained (3) Supervisor of shift will engage the manpower in job. (4) The manpower will bring their own safety gears, i.e. shoes, helmet, safety belts, etc.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required .
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required
Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required .
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mmX 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire overhead line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required
Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required .
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required.
Providing clamps with MS Nuts and Bolts and washers etc. as required.
Dismantling of 70W/250W/400W LED/HPSV street Light fitting with control gear
Erection of 70W/250W/400W LED/HPSV street light fitting with control gear.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV/LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Erection of AB Cable upto 120sqmm (1 KM)
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Erection of G.I. Wire No. 8 SWG including binding etc. as required
Erection of cradle guard as required.
Supply of 8 SWG G.I. wire
Supplying of chemical earthing rod of 14-15mm dia, 3 metres length Copper bonded Carbon steel core electrode, with earth enhancing compound of 15 kgs, for making connection with. Cable/flat complete set as required.
Labour charges for excavation for erection of earthing set including supplying of inspection chamber complete with connection, testing and commissioning, etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)(12 mtr/each earthpit)
Trimming of trees
Painting of pole with synthetic enamel paint of approved brand and manufacture to give an even shade with two or more coats. (6 sqm/pole approx)
Day to Day checking, repair, maintenance and fault rectification in the power supply system of various residential/ Non-residential quarters including maintenance of overhead lines feeding power supply to colony, rectification of running breakdown maintenance of feeder switches, etc. and maintenance of power supply at Balanda Substation, Light Vehicle Substation, Filter Bed, Rescue Station, Bus stand, Balanda Dispensary, Market, Club, JACL Lab and other miscellaneous places under administrative Control of Balanda Colony of Jagannath OCP for period of 2 years with engagement of below manpower: (1) Skilled Manpower: 04nos./day (Lineman) (2) Semi-skilled Manpower: 06nos./day (Electrical Helper)
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .