Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-Finance 388 SRI BENAKA 1ST PHASE 4TH STAGE VIJAYANAGAR MYSORE KARNATAKA 570017 | MYSURU | KARNATAKA | 570017 | L1 | Accepted-Finance Complied as per NIT | |
| 2 | L2₹16.6 L+₹11,867 (0.72%)Accepted-Finance | L2 | Accepted-Finance Complied as per NIT | |
| 3 | Rejected-Technical | - | Rejected-Technical Not complied as per NIT |
Tender Value
₹16.2 L
EMD Value
₹32,500
Closing Date
27 Dec 2024, 5:00 pmClosed
The Director, CSIR-CFTRI
Cheluvamba Mansion, KRS Road, DR Mohalla, Mysuru - 570020
Replacing all existing Electrical Wirings, Switch Gears, Obsolete Panels, Providing BLDC Fans, LED Lights, Copper Plate Earthings etc., at Health Centre of CSIR-CFTRI, Mysuru.
2024_CSIR_220676_1
E/EW/007/1082/2024-25
Open Tender
Electrical Works
Item Rate
45 days
at CSIR-CFTRI HQ
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹32,500
3 Jan 2025
20 Dec 2024
30 Dec 2024
20 Dec 2024
27 Dec 2024
20 Dec 2024
20 Dec 2024 - 26 Dec 2024
Amount
Supplying, Installation, Testing & Successful Commissioning of 5 Watts LED Batten Light (light colour as per choice of Engineer Incharge) complete with internal wiring, 1 metre length of any standard make rated 3 core copper wire etc., ready to use suitable to fix on wall / ceiling and to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting shall be terminated to the existing ceiling rose. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying, Installation, Testing & Successful Commissioning of 36 Watts 4 Feet LED Batten Light (light colour as per choice of Engineer Incharge) complete with internal wiring, 1 metre length of any standard make rated 3 core copper wire etc.,, ready to use suitable to fix on wall / ceiling and to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting shall be terminated to the existing ceiling rose. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying, Installation, Testing & Successful Commissioning of IP65 50 Watts LED Focus Light (light colour as per choice of Engineer Incharge) complete with internal wiring, 1 metre length of any standard make rated 3 core copper wire etc., ready to use suitable to fix on wall / ceiling and to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting shall be terminated to the existing ceiling rose. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying, Testing, Successful Laying inside 40mm dia PVC Pipe / Bend / Collar and Commissioning of 4 x 4.0 sq.mm PVC insulated and PVC sheathed / XLPE aluminium armoured conductor cable of 1.1 KV grade on wall / surface / floor as required using suitable size saddles of 1mm thick. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying and making end termination with brass compression gland and aluminium lugs (bullet / flat) for 4 x 4.0 sq.mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Note: Each means all lugs for one end of the UG Cable. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying, Installation, Testing & Successful Commissioning of 16 PVC Modular Box along with Modular Base, Cover Plate etc., in recess / wall using suitable hardwares etc., as per directions of Engineer In-Charge and consisting of following Modular items a) 5/6 Amp Switch - 2 Nos; b) 6 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 15/16 Amp Switch - 2 Nos; d) 6 pin 15/16 Amp Socket Outlet - 2 Nos and e) 20 Amps, 2 Pole, "C" Curve, 10kA, 230V Mini MCB - 1 No. Internal wiring for 5 Amps Switch & Socket with 2.5 sq.mm FRLS Multistrand, Single Core Copper Wire; for 15 Amps Switch & Socket with 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire, Green Colour for Earthing Loop and terminate all the wires using suitable size Copper Lugs etc., as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supply, Installation, Testing and Successful Commissioning of 9 Inch Dia, 225mm / 230mm sweep, industrial type ready to use Exhaust Fan having Bird Cage with 1.5 FRLS PVC insulated, copper conductor, single core cable and to fix with required size of MS frame duly painted with one coat of primer and 2 coats of paint, suitable hardwares etc., and provide one no. of 3 Pin 5/6 Amps ISI make Socket along with Gangbox and 3 Pin 5/6A Amps ISI make Plugtop as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supply, Installation, Testing and Successful Commissioning of MCB Distribution Box of size 8" (W) x 8" (H) x 8" (D) made out 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of primer & 2 coats of Siemens Gray colour paint, suitable for 230V / 440V, AC to fix on surface / recess. The DB shall consist of Din Rail to fix 1 x 40Amps 2 Pole RCCB having a sensitivity current 30mA, 1 x 32 Amps 2 Pole MCB, "C" Curve, 10kA Breaking Capacity, 2 nos of blank plates and respective colour LED Indicator for the output tapped from R / Y / B Phase. The output from the RCCB to be connected to the MCB as Input with 6.0 sq.mm single core copper wires (Red & Black), duly terminated with copper lugs. The incoming earth wire from the mains should be terminated to the earth bolt / bar in the box with lugs. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File. Note: Labelling to be done for Input & Output Controls in Paint / Acrylic Sticker.
Single Door IP55 Indoor MCCB Box of size 12" (W) x 24" (H) x 12" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with two coats of red oxide & two coats of enamel paint siemens gray colour and consisting of 1 No of 250A, 36KA Range 4P MCCB and 4 x 250A capacity Copper Bus-Bars for R,Y,B & N. The Bus-Bars should have minimum 4 sets of holes to connect Copper Cables / Wires of size from 10.0 sq.mm to 25.0 sq.mm. The Box should have provision for mounting on the wall with required hardware arrangements, locking arrangements for door, RYB LED Indicating Lamps, 2 nos of earth bolts on either side of the box, 3 numbers of removable plate at the top of the box for Cable/Wire entry, any fire proof sheet to cover the bus-bars, water proof vents on both the sides covered with wire mesh from inside to avoid entry of any insects entering inside the box. To connect the existing Aluminium / Copper Cable as input to the MCCB. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File. Note: Labelling to be done for Input & Output Controls in Paint / Acrylic Sticker.
Single Door IP55 Indoor MCCB Box of size 12" (W) x 24" (H) x 12" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with two coats of red oxide & two coats of enamel paint siemens gray colour and consisting of 1 No of 100A, 30KA Range 4P MCCB and 4 x 200A capacity Copper Bus-Bars for R,Y,B & N. The Bus-Bars should have minimum 4 sets of holes to connect Copper Cables / Wires of size from 10.0 sq.mm to 25.0 sq.mm. The Box should have provision for mounting on the wall with required hardware arrangements, locking arrangements for door, RYB LED Indicating Lamps, 2 nos of earth bolts on either side of the box, 3 numbers of removable plate at the top of the box for Cable/Wire entry, any fire proof sheet to cover the bus-bars, water proof vents on both the sides covered with wire mesh from inside to avoid entry of any insects entering inside the box. To connect the existing Aluminium / Copper Cable as input to the MCCB. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker.
Supply, Installation, Successful Commissioning and Testing of LT Double Door IP55 Indoor Panel Box of size 30" (W) x 36" (H) x 20" (D) made out of 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of red oxide & 2 coats of Siemens Gray colour paint and consisting of items as mentioned in a) to k). The newly laid 4 x 50 sq.mm Copper Cable shall be terminated as Incoming to 200A MCCB with suitable type copper lugs. The Output from the 200A MCCB shall be connected to 4 x 250A range using Individual Copper Cable / Copper Bus-Bars. From the Bus-Bar, inputs shall be tapped individually for all using 10.0 sq.mm FRLS multistrand copper wire along with suitable type of copper lugs and standard colour code of wiring, neatly dressed to 1 x 125A 4 Pole, 36KA MCCB, 2 x 63 Amps 4 Pole RCCB, 2 x 63 Amps 4 Pole MCB, 2 x 32 Amps 2 Pole MCB and 5 Pin 63 Amps Industrial Type Metal Clad Socket through one of the 63Amps 4 Pole RCCB. All new / existing out-going Cables / Circuits to be connected to this LT Panel. A Separate Aluminium Bus-Bar for connecting the Sub-Circuits Earth Wires in the Panel and extended for 2 Inches outside the Panel on both sides, for connecting Bare Copper Wires from the Earthpit should be provided. 4 Nos of plate cutting for fixing glands, entry and exit of Copper / UG Cable(s), Cable Alley are to be made available. The panel shall be have individual hinges with locking arrangement doors for each MCB / RCCB / MCCB distribution chamber within the compartment. The LT Box shall be mounted on the floor with total stand height of 0.75-1.5 Feet grouted to the floor, doors on front with locking arrangements. The stand portion from the floor on all 4 sides shall be suitable covered with removable type painted metal sheet (screwed to the stand). All visible Bus-Bars inside the Panel shall be suitably covered with the 6mm Hylem sheets from. 6" x 6" water proof vents shall be provided on both the sides of the Panel, covered with wire mesh from inside. The LT Panel is also included for Supply, Installation, Successfull Commissioning and Testing of 1 number Of suitable range Multifunctional 3 Phase, 4 Wire Electronic Trivector Energy Meter with Class 0.1 accuracy, required range of CTs, to read and record upto 250 Amps. Important: All incoming / outgoing armoured cables / Sub-Main Circuits shall be terminated with suitable size copper / aluminium lugs (for copper cables / wires, coppler lugs and for aluminium cables / wires, aluminium lugs). During connections, if any Incoming / Outgoing cables is / are need to be extended, part of the work (Cable / Wires for extension of connection will be provided by CSIR-CFTRI). Item List for the above Panel: a) 250 Amps capacity Copper Bus Bar of size 50mm x 5 mm insulated with fire proof tape, mounted on Bus Bar Insulators. - 04 Nos; b) 200A, 36KA, 4 Pole MCCB - 01 No.; c) 125A, 36KA, 4 Pole MCCB - 01 No.; d) 63A, 4 Pole RCCB 440V AC with 30mA sensitivity - 02 Nos.; e) 32 A, 2 Pole MCB - 02 Nos.; f) 63 A, 4 Pole MCB - 02 Nos.; g) RYB LED Phase Indication Lamps with Fuse Unit for Input and Output - 2 Sets; h) Multifunctional 3 Phase, 4 Wire Electronic Trivector Energy Meter with Class 0.1 Accuracy - 01 No.; i) 5 Pin 63 Amps Industrial Type Metal Clad Plug & Socket - 01 No.; j) HT Rubber Mat of 6' x 3' - 01 No.; k) Aluminium Earth Bus-Bar 50mm x 5mm - 01 No. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File. Note: Labelling to be done for Input & Output Controls in Paint / Acrylic Sticker. Panel Design: As per Engineer In-Charge.
Labour charges for digging 8 feet of depth below ground level, including hard soil, rocks, cement surface etc.,if any encountered, fixing the Item No:27, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:27 as required, already estimated under S.No.27).
Dismantling & taking down all Old Aluminium Electrical Wirings / Fans / Lights / Switch Boards / Telephone / Old Internet Wirings and respective related wirings, hardwares etc., after carefully disconnecting the incoming electrical input and insulating the same, depositing all the old materials in an organised manner to the Auction / Electrical Section Store Yard or as per the advise of the Electrical Officer In-Charge of the Project without any damage. Note: While dismantling proper care should be taken, not to disturb the New Internet Network lines in all the rooms, however system engineer shall guide accordingly while dismantling as stated above.
Group A Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Group B Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make for all: Same as Item No: 14
Group C Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make for all: Same as Item No: 14
Wiring for circuit / submain wiring alongwith earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 14. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 14. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 14. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earth wire with 2 X 6 sq. mm + 1 X 6 sq. mm earth wire earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 14. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earth wire with 4 X 6 sq. mm + 2 X 6 sq. mm earth wire earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 14. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earth wire with 4 X 16 sq. mm + 2 X 6 sq. mm earth wire earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 14. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make: Same as Item No: 6
Supplying & Fixing DP sheet steel enclosure on surface / recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. MCB Rating will be chosen as per site condition. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying & Fixing TP sheet steel enclosure on surface / recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required. MCB Rating will be chosen as per site condition. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying and fixing 20A, 240V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. Note: Masonry enclosure size is 1.5 Feet x 1.5 Feet x 1.5 Feet. As per IS 3043, charcoal/ coke and salt should be refilled with 50 Kg each per earthpit. The copper plate has to be tinned, connected copper flats have to be brazed and only SS nut, bolts and washers to be used.
Providing and laying earth connection from earth electrode with 4.00mm dia copper wire in 15mm G.I. pipefrom earth electrode including connection with copper thimble excavation and refilling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerence as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying and fixing of 25 mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying and drawing 4 pair of 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying and fixing modular Telephone socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc., as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
Supplying and fixing 1 or 2 Module (75mm x 75mm) GI box alongwith modular base & cover plate for modular switches in recess etc., as required. Make: Please refer Page No 36 & 37 for Special Conditions of Electrical under Tender Document File.
AKEY ELECTRO TECHNIQUES (BID ID -794745)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .