Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹29.9 L+₹71,800.20 (2.46%)Rejected-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to non-fulfillment of NIT criteria being un-enlisted contractor | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to nor enlisted in requisite category b(ii) and not related documents uploaded |
Tender Value
₹29.1 L
EMD Value
₹58,200
Closing Date
7 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineers
Commander Works Engineers (Sub) Military Engineer Services PO- Barrackpore Dist- 24 Pgns (N) Kolkata- 700120 (W.B)
REPAIR, MAINT OF HT, LT ELECTRIC SUPPLY LINES, PLANTS AND EQPTS INCLUDING PANELS, ETC AT KANKINARA AREA UNDER GE (N) KOLKATA
2022_MES_567833_2
CWE/(N) KOL/26 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (North) Kolkata
As per NIT
6 documents required · 6 mandatory
₹500
GE (North) Kolkata
₹58,200
Yes
16 Feb 2023
23 Dec 2022
9 Jan 2023
23 Dec 2022
7 Jan 2023
24 Dec 2022
Amount
Repair/maintenance and servicing of step down transformer 3.3 KV/433 Volt of capacity 200 KVA (Make - Bharat), comprising following work services :- (a) Disconnection carefully of cable end termination of HT & LT side. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks. (c) Draining out transformer oil and keeping aside in barrel for re-use and then again pouring back after necessary filteration and dehydration including top up with new transformer oil to make up the reduced quantity if required (New Transformer oil for topping up will be measured and paid separately). (d) Replacement of top and buttom Gaskets. (e) Servicing of tap changing gears by cleaning and polishing tapping contact points. (f) Cleaning of bush and stud both HT/LT side and refixing the same with new cock sheet as required (g) Replacing unserviceable stud and bush if required as directed by Engr-in-Charge. (h) Reconnection of all cable terminals HV & LV sides and refixing the top cover after replacement of gaskets, conservator tank in position. (j) Cleaning and heating of silica gel in breather and replacing with new silica gel to make up the reduced quantity. (k) Connecting HT & LT side with existing incoming and outgoing cables including reconnection of earth strip/lead. Note: (i) Filteration and dehydration of transformer oil, New transformer oil, New bushes and stud and New silica gel required for replacement shall be measured and paid for separately. (ii) Spares like bushes and studs,New silica gel,New buchholz relay and M seal monoplast, etc required for replacement shall be measured and paid for as supply only separately. The labour element involved in replacing the spares shall be deemed to include in the unit rate quoted. (iii) The unit rate quoted shall include the cost of all other minor spares as required not mentioned hereinafter.
All as per item No. 1 above but for transformer of capacity 250 KVA. (Make - Voltamp)
All as per item No. 1 above but for transformer of capacity 400 KVA. (Make - Hindustan)
All as per item No. 1 above but for transformer of capacity 500 KVA. (Make - Voltamp/ Alstom)
Supply only bushing and stud complete with porcelain insulators for LT side (as per existing size/Model) for transformer of capacity 500 KVA. (Make- Alstom/ Voltamp)
All as per item No. 5 above but transformer capacity 400 KVA. (Make - Hindustan)
All as per item No. 5 above but transformer capacity 250 KVA (Make - Voltamp)
All as per item No. 5 above but transformer capacity 200 KVA (Make - Bharat)
Supply and fixing bushing and stud complete with porcelain insulator for HT side (as per existng size/Model) for transformer of capacity 500 KVA .(Make:Alstom/Voltamp)
All as per item No.9 above but Transformer capacity 400 KVA (Make: Hindustan)
All as per item No. 9 above but Transformer capacity 250 KVA (Make: Voltamp)
All as per item No. 9 above but Transformer capacity 200 KVA (Make:Bharat)
Supply and fixing transformer oil temperature gauge dial type range 0 to 100 deg C as per existing type and model all as directed.(Make:PRECIMEASURE/GURU)
Supply and fixing Silica gel in existing breather assembly all as directed.
Filteration and dehydration of old transformer oil and removing of sludge by continuous circulation through transformer oil filtration plant with heater strips to achieve dielectric strength of not less than 50 KV at 2.5 mm gap of electrode as per IS-1866(1985) and improvement of acidity by minimizing percentage of acidity using chemical reagents all as spedified and as directed by the Engn-in-Charge.
Supply and top up transformer oil having di-electric strength not less than 60 KV at 2.5 mm gap after initial dehydration/ filteration conforming to IS 335 and ISI marked to be brought at site in sealed container all as directed by the Engr-in-Charge. (Make:- Castrol / Veedol / IOC / HPL/ Savita)
Supply and fixing of HT CT of ratio 300/5/5 Amps all as spedified and as directed.
Repair/servicing of HT PT epoxy type including replacing of primary and secondary winding, replacement of PT bush-03 Nos and housing bush-03 Nos all as spedified and as directed by Engr-in-charge.
Supply and fixing of tripping coil 110/30 V DC all as spedified and as directed by Engr-in-charge.
Supply and Fix Panel heater for VCB HT panel including necessary fixing arrangement including taking out unserviceable one all as spedified and as directed Engr-in-charge.
Material and Labour for reparing / replacement of locking arrangement of HT Panel including necessary fixing arrangement including taking out unserviceable one all as spedified and as directed by Engr-in-charge.
Maintenance and servicing of 3.3 KV VCB of 400 Amp, 250 MVA (Make-Crompton Greaves/ Kirloskar) by opening out HT cable termination joints, checking and cleaning all the spares of VCB to avoid any chances of flashing / burning due to loose connection, replacement of all bolts, nuts & washers (if found damaged due to flashing) with new one (anodised) of existing size, testing and calibration of earth fault and over load relays complete after re-connection of all dismantled cables and again testing after re-charging the VCB complete all as specified and as directed by Engr-in-charge.
Maintenance and servicing of 3.3 KV OCB of 400 Amp, 250 MVA (Make-Alstom) by opening out HT cable termination joints, checking and cleaning all the spares of VCB to avoid any chances of flashing / burning due to loose connection, replacement of all bolts, nuts & washers (if found damaged due to flashing) with new one (anodised) of existing size, testing and calibration of earth fault and over load relays complete after re-connection of all dismantled cables and again testing after re-charging the VCB complete all as specified and as directed by Engr-in-charge.
Servicing of HT panel including replacement of burnt out lugs, scraping the bus bar chamber, cleaning the bus bar panel with CTC, remove the burnt out electrical wiring and replacement of bolt, nuts, washer and new wiring for metering eqpt, phase sequence RYB with bus bar insulation tapes, heating with blower, reconnecting, testing and commissioning complete all as specified and directed by Engr-in-charge. Note:- Cost of Nuts, bolts, washers, insulation tapes, wiring & other connecting items shall be included in unit rate.
supply and fix electronic relay for VCB 3.3 KV of capacity 400 Amps of ratio 80-40/5A complete including taking down old u\s relay all as specified and as directed (Make: CG\Kirloskar)
Supply, install, fixing commisioning and testing ACB (Air circuit breaker) 800 Amp, 4 pole, 415 Volt, 50 kA, Drawout type with microprocessor release including suitable size of thimble/ lugs for connection of cable and testing after completion to be fixed in existing LT Panel with all fixing material such as bus bar, thimble, lugs, nut bolts and washer of suitable size required at site for fixing ACB complete including taking out old unserviceable ACB any type after disconnection electrical connection complete all as specified and directed by Engr-in-charge. (Make - C&S/Legrand/Siemens/Schneider/ABB/Havells)
All as per item No. 26 above but ACB of capacity 630 Amp all as directed. (Make - C&S/Legrand/Siemens/Schneider/ABB/Havells)
Servicing / Repairing of control panel of automatic power factor correction panel 150 KVAR to 250 KVAR capacities by replacement of unserviceable / defective / burnt out wiring with appropriate and existing size copper flexible cable with all fixing arrangement, minor parts and connections for making panel serviceable including taking out old wiring complete all as specified and directed. Note : Cost of cable alongwith dressing of cables, minor parts, fixing arrangement, etc including provision of necessary cable lugs as required for wiring and make panel serviceable are deemed to be inclusive in the quoted rates.
Supply and fix 3 phase power capacitor 1 KVAR heavy duty 440 Volt metalised Polypropline Dielectric, type MPPH as per existing type in the existing APFC Panel including taking down old unserviceable capacitor any type complete all as specified and directed. (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 2 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 3 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 5 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 10 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 12.5 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 15 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 20 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 25 KVAR, (Make : Neptune/L&T/Havells/Legrand)
All as per item No. 29 above but of capacity 50 KVAR, (Make : Neptune/L&T/Havells/Legrand)
Supply and fixing automatic power factor control relay 12 stage APFC relay with single CT input suitable for existing APFC panel including taking down old unserviceable control relay any type complete all as specified and as directed. (Make : C&S /NEPTUNE/L&T/SIEMENS)
Supply and fixing contactor relay type MO0AC 22E (2NO+2NC) contactor for AC control standard coil voltage 240 V, 50/60 Hz, AC-15, 4 A including taking down old unserviceable contactor any type complete all as specified and as directed. (Make : L&T Cat No - CS91625/C&S/SIEMENS)
Supply and fixing front mounting add-on aux. contact block suitable for MO0AC 22E (2NO+2NC) contactor for AC control standard coil voltage 240 V, 50/60 Hz, AC-15, 4 A including taking down old unserviceable contactor any type complete all as specified and as directed. (Make : L&T Cat No - CS94596/ C&S/SIEMENS)
Supply and fixing capacitor duty contactors - Type MO C25 suitable for capacitor 25 kVAr Rating, 440V, 3Ph, 50Hz for AC control standard coil voltage including taking down old unserviceable contactor any type complete all as specified and as directed. (Make : L&T Cat No - CS96322/ C&S/SIEMENS)
Supply and fixing capacitor duty contactors - Type MO C12.5 suitable for capacitor 12.5 kVAr Rating, 440V, 3Ph, 50Hz for AC control standard coil voltage including taking down old unserviceable contactor any type complete all as specified and as directed. (Make : L&T Cat No - CS96321/ C&S/SIEMENS)
Supply and fixing capacitor duty contactors - Type MO C5 suitable for capacitor 5 kVAr Rating, 440V, 3Ph, 50Hz for AC control standard coil voltage including taking down old unserviceable contactor any type complete all as specified and as directed. (Make : L&T Cat No - CS96127/ C&S/SIEMENS)
Supply and fix MCB TP 32 Amps, 240 volts, 'C' series with all incoming / outgoing connections with proper size of lugs including taking down the old unserviceable MCB complete all as specified as directed. (Make - Havells/C&S/L&T/ Indoasian)
Supply and fixing in repair to digital voltmeter square type, 0-500 volt complete all as specified and directed. (Make - AE/L&T/C&S/Legrand)
Excavation in trenches not exceeding 1.5 m width or n exc 10 sqm on plan and n.exe 1.5 m in depth for taking out/laying of cable,foundation etc and getting out in soft/loose soil complete all as specified and as directed.
All as per Item No-1 above, but depth exceeding 1.5 m and not exceeding 3.0 m
Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtrs and depositing where directed including spreading, leveling at a level not exceeding 1.5 mtr from the starting point complete all as specified and as directed
Cutting hard standing/ road for laying of cable and filling with PCC (1:3:6), type C2, of size not less than 30 cm X 30 cm complete all as specified and directed.
Taking up or down worn out/ damaged/partly serviceable / unserviceable PVC insulated cable, armoured, heavy duty with aluminium conductors of any size, 11/1.1 KV volt grade from pole / wall / pipes / roof tops etc,testing,segregating and kepping in safe castody the serviceable portion for reuse and depositing remaining to the stores complete all as specified and directed.
Taking up or down worn out/ damaged/partly serviceable / unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors any size, 11/1.1 KV grade from trench ,testing,segregating and kepping in safe castody the serviceable portion for reuse incl bricks, stacking serviceale bricks for reuse complete all as specified and directed. (NOTE :-Excavation wherever required will be measured and paid separately)
Laying, commissioning and testing HT XLPE insulated PVC sheathed armoured heavy duty electric cable with 95 sqmm 3 core aluminium conductor for working voltage upto and including 11000 volts, in duct, fixed to pole, wall/ roof and make good to disturbed surface including cable glands and aluminium thimble/ lugs of suitable size for making connection including taking down old cable complete all as specified and directed. Note : (a) Only Cable will be provided by the dept under Sch "B" free for fixing and all other tools and item are required for laying of cable and making connection included in quoted rates.
Supply and fixing, commissioning, testing XLPE insulated PVC sheathed armoured heavy duty electric cable with aluminium conductor for working voltage upto and including 1100 volts, in duct / trenches, fixed to pole, wall/roof and make good including cable glands required size of aluminium thimble for making connection complete of size 400 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
All as per item No. 56 but of size 300 sq mm, 3.5 core.
Laying ,commissioning and testing XLPE insulated PVC sheathed armoured heavy duty electric cable with aluminium conductor for working voltage upto and including 1100 volts, in duct / trenches, fixed to pole, wall/roof and make good including cable glands required size of aluminium thimble for making connection complete of size 240 sqmm 3.5 core complete all as specified and directed by Engr-in-charge. Note : (a) Only Cable will be provided by the dept under Sch "B" free for fixing and all other tools and item are required for laying of cable and making connection included in quoted rates.
All as per item No. 58 but of size 120 sq mm, 3.5 core.
All as per Item No. 58 above, but 95 sq mm, 3.5 core.
All as per Item No. 58 above, but 70 sq mm, 3.5 core.
Material and labour for sand cushioning with clean dry sand laid in trenches for cable protection complete all as specified and directed.
Supply and lay sub class 'B' bricks, laid dry in trenches for cable protection laid with its longitudinal axis perpendicular to the cable axis complete all as specified and directed
All as Item No. 63 above but laying only (serviceable Bricks, obtained from above item no 54 shall be reused)
Supply and fix galvanised iron pipe in 80 mm bore, light grade for protection of UG cable laid in trenches / fixed to pole with MS clamp,nut, bolt etc complete with all fitting such as socket or any other item required for fixing of pipe including taking down old unserviceable one complete all as directed. (Note :- MS clamp, nut,bolt etc required for fixing the pipe with pole shall be deemed to be included in the quoted rate).
Material and labour for PCC (1:4:8) type D-2, (using 40 mm graded stone aggregate) as in foundation , filling and mass concrete for pole , etc including necessary form work complete all as specified and directed
Material and labour for PCC (1:3:6) type C-1, (using 20 mm graded stone aggregate) as in coping of poles, repair of platform for Panels / Feeder Pillar Boxes, foundations etc including necessary form work complete all as specified and directed.
Material and labour for cable jointing kit 11 kV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm. (Make - Raychem/ Mseal/ Denson/3M)
Material and labour for cable jointing kit 11 kV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm. (Make - Raychem/ Mseal/ Denson/3M)
Materials & labour for painting to Panel any size (inside/out side) with angle iron support from the ground level with two coat blue synthetic enamel paint (including preparation of old surface) in complete all as specified and as directed
Supply and laying Rubber mat of 1 meter x 2 meter x 19 mm for electrical Insulation complete all as specifed and directed.
M&L for preparation surface of old painted pole and painting with Two coat of aluminium paint on MS swaged pole of height upto 9 to 11 metres including pole numbering to be written with white paint on 5" dia black back ground complete all as specified and directed by Engr in Charge
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of size 32x6 mm length upto 7.5 mtr by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth strip protected by and including 40mm dia GI pipe (light grade), alternate layers of charcoal and salt, including 40 mm bore GI tubing length upto 7.5 mtr for watering to earth electrode, earth lead connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre-cast RCC(1:1.5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 3 of SSR part-1 and testing on completion including taking out old earthing complete all as specified and directed.
S&F Earth continuity conductor galvanised iron strip 32 x 6mm main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking out old wire complete all as specified and directed.
supply and fix , straight through heat shrink cable joint kit for LT UG cable of size 95/120/150 sqmm 3.5 core including excavatin of earth at undergruond cable fault position and making good surface at the fault position complete all as specified and as directed by Engr-in-charge. (Make- Raychem/ Mseal/ Denson/3M).
supply and fix straight through heat shrink cable joint kit for LT UG cable of size 50/70 sqmm 3.5 core including excavatin of earth at undergruond cable fault position and making good surface at the fault position complete all as specified and as directed by Engr-in-charge. (Make- Raychem/ Mseal/ Denson/ 3M)
Supply and fix in replacement of MCCB 4 Pole, 800 Amps,AC, 415Volt , rapturing capacity 50 kA with adjustable thermal setting and adjustable magnetic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. (Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Supply and fix in replacement MCCB 4 Pole, 400 Amps,AC, 415Volt , rapturing capacity 36 kA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. (Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Supply and fix in replacement MCCB 4 Pole, 315/320/350 Amps,AC, 415Volt , rapturing capacity 36 kA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. (Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Supply and fix in replacement MCCB 4 Pole, 250 Amps,AC, 415Volt , rapturing capacity 36 KA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. (Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Supply and fix in replacement of MCCB 4 Pole, 200 Amps,AC, 415Volt , rapturing capacity 36 KA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed.(Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Supply and fix in replacement of MCCB 4 Pole, 160 Amps,AC, 415Volt , rapturing capacity 36 KA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed.(Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Supply and fix in replacement of MCCB 3 pole, 125 Amps, 415 volts,16 KA as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. (Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Supply and fix in replacement of MCCB 3 pole, 100/63 Amps, 415 volts,16 KA as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. (Make : C&S/Legrand/ Siemens/ABB/ L&T/Havells/Hager)
Ultimate Solution Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .