Superintending Engineer,Western El.Circle,PWD
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
SITC of 250 KVA Silent D.G.Set for emergency power supply with allied E.I. work at Cold Chain and WIC in the Campus of CMOH Office Building Burdwan SITC of AC machines
2017_WBPWD_97319_1
WBPWD/SEWEC/BED /NIQ-67/2016-17
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
BURDWAN
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,148
Yes
6 Dec 2024
9 Jan 2017
17 Jan 2017
9 Jan 2017
16 Jan 2017
9 Jan 2017
Amount
Supply & Delivery of 2.0 Ton SPLIT type room air conditioner having the following specification:- (a) Cooling capacity nominal (k cal/hr):5800.Cooling capacity (min) guaranteed(k cal/hr) 5500 or as per the model mention below (b) Star rating-4 star. (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary. (e) Mini. Room Discharge air flow rate—800cu.m/hr.as per the model mention below (f) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others. g) Refrigerant must be R410A/R22(Make—Mitsubishi Heavy-SRK24Cs-S6/Similar model of O-General ,Machine should have R410A refrigerant and PCB board of Indoor unit should be Placed within the metal Box.
Supply & Delivery of 1.5Ton SPLIT type room air conditioner having the following specification:- (a) Cooling capacity nominal (k cal/hr):4400-4500(k cal/hr).as per the model mention below (b) Star rating-3 star. (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary. (e) Mini. Room Discharge air flow rate—700cu.m/hr.as per the model mention below (f) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others. g) Refrigerant must be R410A/ (Mak--Mitsubishi Heavy-SRK18CS-S6/ Similar model of O-General ,Machine should have R410A refrigerant and PCB board of Indoor unit should be Placed within the metal Box..
Installation of following rated Split type air -conditioner machine indoor & outdoor unit after cutting hole in wall as required and supply & installation of MS angle iron frame made by 40x40x5 mm thick & intermediate support by 25x6 mm MS flat for providing condensing unit after cutting hole in wall as required & mending good damages and finishing by sand, cement, ¼ size stone chips as per direction of EIC.
a) 1.5 Tr capacity
b) 2 Tr capacity
S/F extra5/8”copper pipe with insulation and Necessary taping
S/F extra1/4”copperpipe with insulation Necessary taping
S/F 3/4” Original water pipe for water outlet
S &F 3 core 2.5 sq mm pvc cu cable for connection between indoor & outdoor units(make polyca/Finolex)
Scaffolding charges for fittings of out door unit at the two storied building.
ARATI ENTERPRISE
FREEZING POINT
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .