Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹21.5 L+₹1.1 L (5.57%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹24.5 L+₹4.1 L (20.3%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹25.0 L+₹4.6 L (22.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹29.0 L+₹8.6 L (42.3%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) B/R Chakeri Kanpur
GE (AF) B/R Chakeri Kanpur
PERIODICAL SERVICES AND MISC B/R REPAIR WORK TO CERTAIN BLDGS UNDER AOR OF AGE B/R-II AT AFS CHAKERI KANPUR
2021_MES_418547_1
GE(AF)/CHK/T-55 OF 2020-21
Open Tender
Civil Works
Item Rate
272 days
GE (AF) B/R Chakeri Kanpur
Class D and cat a(i)
8 documents required · 8 mandatory
₹500
GE (AF) B/R Chakeri Kanpur
₹60,000
31 Mar 2021
3 Feb 2021
6 Mar 2021
3 Feb 2021
3 Mar 2021
19 Feb 2021
4 Feb 2021 - 12 Feb 2021
60 days
Amount
M & L for preparation of old decorated surfaces of wall and applying one coat of white wash complete all as specified and directed.
Ditto all as per item No.1.00 above but applying two coat of white wash on walls complete all as specified and directed.
Ditto all as per item No.1.00 above but one coat of white wash on ceiling surfaces complete all as specified and directed.
Ditto all as per item No.1.00 above but two coats of white wash on ceiling complete all as specified and directed.
M & L for preparation of old painted steel and iron surfaces of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted surfaces of wood and wooden based materials of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old painted steel and iron surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of Aluminium paint complete all as specified and directed.
M & L for preparation of old surfaces of walls including cornices, pillars etc and applying one coat of Oil Bound Distemper including filling of small holes complete all as specified and directed.
Ditto all as per item No.8.00 here-in-before but on ceilings surfaces.
M & L for applying 1 mm thick wall care putty on wall or ceiling surface including sanding and rubbing for smooth surface complete all as specified and as directed.
M & L for applying two coats of oil bound distemper over a coat of primer on wall/ceiling surface complete all as specified and directed.
M & L for preparation of old decorated surfaces of walls and applying one coat of cement based paint complete all as specified and directed.
Ditto all as per item No.12.00 above but applying two coat of cement based paint complete all as specified and directed.
M & L for writing letters or figures (Block, Roman, Italic or Indian) with synthetic enamel paint not exceeding 30 cm high complete all as specified and as directed .
Taking down cement plaster on bricks or stone walls or ceilling etc. including raking out joints, hacking for key scrubing down with water etc complete all as specified and directed.
M & L for 15 mm thick rendering in CM (1:6) on other fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M & L for 10 mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M & L for 5 mm thick rendering in CM (1:3) on ceiling fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement and applying three coat of white wash on ceiling after preparation of surfaces complete all as specified and directed.
M & L for preparation of new undecorated surfaces of walls and applying two coat of cement based paint over a coat of primer complete all as specified and directed.
Complete removal of existing treatment on plastered or unplastered surface of wall or ceiling including cleaning the surface with the help of hand held /long hand scraper / sander and preparing the surface smooth including necessary repair to scratches/cracks etc by filling cracks upto 3 mm with crack fill paste by filling compound complete all as specified and directed. (Note : Where it is not possible to use scraper/grinder for removing existing treatment, manually operated hand tools is to be used as directed by Engr-in-Charge).
M & L for preparation of surface and applying one coat exterior water based primer with airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 m. The spray should be of reputed make as approved by GE as recommended by Manufacturer/Applicator complete all as specified and directed.
M & L for applying two coats of exterior weather proof anti algae 100% acrylic, smooth, emulsion with five years of performance warranty applied by using air-less techonlogy with maximum working pressure of 3300 PSI and capable of operational single spray gun with a maximum material hose length 30 m. The spray should be of reputed make as specified by paint supplier and accessories for appling the exterior emulsion, it should be able to spray in hard to reach areas and acheive the good bounding and penetration of paint on the surface to achive excellent appliction using limited manpower complete all as specified and directed.
M and L for providing and applying high quality acrylic modified resin based texture of Dholpur /red sand stone pattern with anti algae and UV resistante properties to be applied as intermediate finish in desired pattern @ 43.04 Kg /10 Sqm to form film of 1-1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plastered surface, followed by top coating with premium acrylic smooth paint with silicon additive of reuqired shade by two or more coats @ 1.43 ltrs /10 sqm complete all as specified and directed.
Cleaning and removing of all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. exceeding 250 ltrs but not exceeding 500 ltrs of capacity complete all as specified and directed. (Note : Date of cleaning shall be written on tanks after cleaning by synthetic enamel paint).
Cleaning and removing of all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. exceeding 500 ltrs but not exceeding 1000 ltrs of capacity complete all as specified and directed. (Note : Date of cleaning shall be written on tanks after cleaning by synthetic enamel paint).
M & L for applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floor, any thickness, description and in any position not otherwise described complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in flooring / paving / plinth protection including finishing the surfaces even & smooth without using extra cement, complete all as specified and directed.
S & F in repair 2 mm thick linoleum, plain coloured sheet, laid and sealed down with an approved adhesive including stretching, cutting and fitting complete all as specified and directed.
Rooting out trees, flora, fauna and foliage as grown on RCC roof surfaces and brick walls by cutting hole into slabs/walls for digging out roots and using chemical to burn deep rooted tree roots etc and making good to dirturbed portion of wall/roof with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
S & F in repair factory made UPVC white colour fully glazed door for an opening size 2.30 m x 2.60 m made of UPVC profile section. Out of 2.30 m x 2.60 m opening size, the fully glazed double shutter openable (side hung type) door of size 1.20 m x 2.10 m should be provided at centre of opening and remaining portion shall be fully glazed fixed type window made of frame work of UPVC profile section fitted with 6 mm thick toughened glass. The UPVC profile section for door frame (outer frame) and fixed portion should not be less than 60 mm x 60 mm size and UPVC profile section for door shutter frame shall not be less than 110 mm x 60 mm size. GI Channel for reinforcement of UPVC profile section shall not be less than 1.20 mm thick for 60 mm x 60 mm UPVC profile section, it should not be less than 1.50 mm thick for UPVC profile section 110mm x 60mm. Toughened glass 6 mm thick with appropriate glazing beads as per profile shall be provided for door shutter and fixed portion. Gasket shall be EPDM best quality rubber. Each door shutter must fitted with 4 Nos 3D hinges having load carrying capacity 125 kg of make Rotomac / DNV / Geviss of doctor window. Hardwares like door handle, tower bolt and chute bolt made of zinc metal as approved by GE in writing. Aluminium (extruded section body) door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and shall be provided in each shutter. Note :- (i) The unit rate quoted by the contractor shall deemed to be included of all the items mentioned above. (ii) All contacts of UPVC frame with wall /floor / ceiling shall be properly sealed with silicon.
S & F solid PVC wall lining consisting of 5 mm thick single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S & F 5 mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Supply and laying 8 mm thick HDF based laminated decorative wooden flooring with tounge and groove interlocking joints system laid over and including 3 mm thick foam as a moisture barrier complete all as per manufacturer instruction. The shade of flooring as approved by GE.
Taking down Shutters of any description exceeding 1.0 sqm but not exceeding 2.0 Sqm each and refixing the same in same openning after easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc. complete all as specified and directed.
M/S SDS Construction Co.
GOPI CONSTRUSTION CO.
M/S ASM ENTERPRISES
KALI CHARAN PANDEY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .